Study on 222Rn reduction rate in boiling groundwater (가열에 의한 지하수 중 222Rn 제거율 고찰)

  • Kim, MoonSu;Kim, Hyun-Koo;Park, Sun-Wha;Kim, Hyoung-Seop;Ju, Byoung-Kyu;Kim, Dong-Su;Cho, Sung-Jin;Yang, Jae-Ha;Kwon, Oh-Sang;Kim, Tae-Seung
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.353-360
    • /
    • 2015
  • Boiling is an efficient removal method to reduce radon in groundwater when ventilating indoor air. 13 groundwater samples with various radon concentrations were used to evaluate the reduction rate of radon with heating temperature and time. The groundwater samples were obtained by Bladder pump and on-situ measurements such as dissolved oxygen (DO) and hydrogen concentration (pH) and so on were carried out by a flow cell system isolated from the ambient atmosphere environment. All samples for measuring radon in groundwater were analyzed by liquid scintillation counter (LSC). The experiment result showed that increasing groundwater temperature enhanced radon removal rate but the initial radon concentration with high level lowered the removal rate. This means that radon reduction in groundwater by heating needs more heating energy and longer heating time with radon concentrations. Radon removal rate in groundwater, therefore, mainly depends on the initial radon concentration, heating temperature, and heating time.

국가 지하수 관측망의 수위 및 온도 자료를 이용한 함양량 산정

  • 박창희;구민호;이대하;김형수
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.351-356
    • /
    • 2002
  • Groundwater recharge rate was estimated by applying the groundwater level fluctuation method utilizing Theis (1937) approach with specific yield estimation technique of Shevenell (1996) and the temperature method using observed data from National Groundwater Observation Stations. Results based on analysis of water level observation data of 10 alluvium wells reveal that the recharge rates for 5 wells of Kum river area range 3.7~25.0% and those for 5 wells of Nakdong river area range 3.6~21.7%. Results obtained from the temperature method based on water temperature data indicated that the upward flow resulted from evapotranspiration is dominant for 4 wells of the Kum river area and 5 wells of the Nakdong river area. The other wells showed the downward flow which is related to groundwater recharge in these areas.

  • PDF

Heat Transfer Performance of Pond Loop type Heat Exchanger for Ground Source Heat Pump using Extruding Ground Water (유출지하수 열원 지열히트펌프용 Pond Loop 열교환기의 열전달 성능)

  • Park, Geun-Woo;Kim, Yoon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.105-107
    • /
    • 2006
  • 유출지하수나 지료수를 열원으로 하는 지열히트펌프의 기초자료로 활용하기 위하여 Pond Loop형 열교환기를 설계, 제작하여 유동이 없는 수조 내에서 수조의 온도가 변화함에 따라 일정한 열교환기 입구온도를 유지하면서 열전달량을 측정하였다. 그 결과 수조를 Heat Source로 사용하는 경우 5,500${\sim}$4,500 kcal/h의 열량이 전달되었고, 수조를 Heat Sink로 사용할 경우 5,200${\sim}$3,500 kcal/h의 열량이 전달되었다. 또한 열교환기 관내 유속이 증가함에 따라 열전달량이 증가하는 경향성을 확인할 수 있었고, 이는 동시에 열교환기 입출구의 차압을 증가시킴을 알 수 있었다. 열교환기의 설계단계애서 사용하였던 열전달관계식으로 구한 총괄열전달계수, U와 실험값을 통해 유추한 U값을 비교 한 결과 실험에 의해 유추된 U값이 24${\sim}$27% 설계치 보다 크게 나타났다. 본 연구를 통하여 유출지하수 뿐만 아니라 하수 및 하천수를 이용한 지열히트펌프의 기초자료를 확보할 수 있었다.

  • PDF

Characterization of Conductive Fractures in Fractured Rocks using Borehole Logging Data

  • 조민조;이대하;이승구;김형찬
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.109-113
    • /
    • 1998
  • 본 연구에서는 전기전도도, 온도, 유속 검층을 이용하여 시추공내의 유동성 단열구조를 확인하고 각 유동성 단열구조를 통한 시추공간의 수리적 연결관계를 해석하였다. 검층은 자연상태와 인근 시추공으로부터의 양수에 의한 부정류상태에서 각각 실시되었다. 자연상태에서는 지하수 유동이 매우 느려 유동성 단열구조가 쉽게 인지되지 않으나, 부정류 상태에서는 각 시추공간의 수리적 연결성을 보여준다. 각 시추공별 검층에서 나타나는 유동성 단열구조는 모두 일치하지 않으며, 특히 부정류 상태에서의 유속 검층에서는 타 검층에서 인지된 유동성 단열구조중 일부만이 시추공간에 서로 수리적으로 연결되어 있음을 보여준다.

  • PDF

Monitoring of Groundwater quality according to groundwater use for agriculture (농업용 지하수 사용에 따른 지하수질 모니터링 평가)

  • Ha, Kyoochul;Ko, Kyung-Seok;Lee, Eunhee;Kim, Sunghyun;Park, Changhui;Kim, Gyoo-Bum
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.30-30
    • /
    • 2020
  • 본 연구에서는 여름철에 농업용수(벼농사용)로서 집중적으로 지하수를 사용하는 지역에서 시기별 지하수 사용에 따른 지하수 수질변화를 평가하기 위해 수행되었다. 연구지역은 충남 홍성군 양곡리와 신곡리 일부를 포함하는 면적 2.83 ㎢(283.3 ha)에 해당하는 지역이다. 연구지역 지하수 수질의 공간적 분포 및 시간적 변화 특성 평가를 위하여 2019년 2회(7월, 10월)에 걸쳐 지하수 관정(21개소)에 대하여 조사 및 분석을 수행하였다. 지하수 샘플은 현장에서 온도(T), pH, 용존산소(DO) 및 전기전도도(EC), 산화환원전위(Eh) 등을 측정하였고, 실험실에서 주요 양이온 및 미량원소(Ca, Mg, Na, K, Si, Sr), 음이온(F, Cl, Br, NO2, NO3, PO4, SO4), 알칼리도, 용존 유기탄소(DOC)와 용존 유기물(DOM) 등을 분석하였다. 지하수 수질조사 결과, 전체의 14~15개소(67~71%)가 Ca-HCO3 유형으로 분류되었으며, 다음으로는 Ca-Cl 유형이 4~5개소(19~24%)가 관찰되었다. 얕은 심도의 관정에서 상대적으로 심도가 깊은 관정보다 대부분 성분(TDS, Ca, Mg, Na, K, Cl, SO4, HCO3, DOC)에서 높은 농도를 나타내었다. 지하수의 수질자료를 이용하여 다변량통계분석법인 주성분분석(PCA: Principal Components Analysis)과 계층적 군집분석(HCA: Hierachical Cluster Anlaysis)를 수행한 결과, 초기 3개 주요 고유성분(eigenvalue)는 PC1 54.0%, PC2 14.2%, PC3 12.3%로 전체 분산의 88.3%를 설명할 수 있었다. PC1은 Ca, Mg, Na, K, Cl, SO4, DOC가 주요한 영향 인자였으며 PC2는 HCO3, NO3, DO에 영향 받음을 확인하였다. 계층적 군집분석 결과, 연구지역 지하수는 Na-Cl 유형의 C-3 관정을 제외하고는 크게 두 그룹으로 구분되어 졌다. 다변량통계분석의 결과에서도 수리지화학, 동위원소, 용존유기물 등의 특성에서 나타나는 것과 유사한 연구지역의 수질특성을 확인할 수 있었다. 연구지역은 차시기 동안 수질변화는 일부 관정을 제외하고는 유의할 만한 수준으로 관찰되지는 않았고, 지하수 사용에 따른 지하수위 회복도 빠르게 진행되고 있는 것으로 나타났다.

  • PDF

Correlation between the Distribution of Discontinuities and Groundwater Flow in Fractured Rock (온도검층과 수압시험을 통한 파쇄암반의 단열분포와 지하수 흐름 상관성 고찰)

  • Park, Seunghyuk;Chung, Il-Moon
    • The Journal of Engineering Geology
    • /
    • v.26 no.4
    • /
    • pp.505-513
    • /
    • 2016
  • The qualitative distribution of a fractured aquifer was characterized by electrical resistivity surveying as a part of basic groundwater investigation in Jangseong. The results were then used to choose sites for observation wells. The locations and distributions of permeable discontinuities were studied by analyses of temperature logs, a borehole image-processing system (BIPS), and hydraulic pressure testing using a double packer. The pressure test showed that the size of the discontinuities correlated with the Lugeon value and the results of the temperature log. The results show that temperature measurement is an effective method to identify permeable discontinuities, with the temperature difference correlating with the size of the aperture of the discontinuity.

지하수 수온을 이용한 냉난방의 COP

  • 최무웅
    • Proceedings of the KGS Conference
    • /
    • 2003.05a
    • /
    • pp.104-105
    • /
    • 2003
  • 21세기는 에너지 크라이스가 일어날 것으로 예측하고 있다. 우리는 냉난방을 화석연료, 원자력에 의존도가 높은 에너지 사용 구조적 특징을 지니고 있다. 그러나 이들은 환경에 큰 충격을 주고 있어 이에 대한 대체 에너지원 개발이 절실히 요구된다. 지하수는 년 중 일정한 온도를 유지하고 있으므로 그 열을 이용하면 친환경적은 물론 대제 에너지원으로 경제적 가치가 있다. 이와 같은 자연적 조건을 이용하여 지하수 수온과 Heat Pump을 연결해 주택, 공공건물의 냉난방을 구축 할 때의 COP를 분석하는데 그 목적을 두고있다. (중략)

  • PDF

Heat Transfer Performance of Pond loop type Heat Exchanger for Ground Source Heat Pump using Extruding Ground Wafer (유출지하수 열원 지열히트펌프용 Pond Loop형 열교환기의 열전달 성능)

  • Park Geun-Woo;Kim Jin-Sang;Lee Eung-Youl
    • New & Renewable Energy
    • /
    • v.2 no.2 s.6
    • /
    • pp.86-93
    • /
    • 2006
  • 유출지하수나 지표수를 열원으로 지열히트펌프의 지초자료로 활용하기 위하여 Pond Loop형 열교환기를 설계, 제작하여 유동이 없는 수조 내에서 수조의 온도가 변화함에 따라 일정한 열교환기 입구온도를 유지하면서 열전달량을 측정하였다. 그 결과 수조를 Heat Source로 사용하는 경우 $5,500{\sim}4,500kcal/h$의 열량이 전달되었고 수조를 Heat Sink로 사용할 경우 $5,200{\sim}3,500kcal/h$의 열량이 전달되었다. 또한 열교환기 관내 유속이 증가함에 따라 열전달량이 증가하는 경향성을 확인할 수 있었고 이는 동시에 열교환기 입출구의 차압을 증가시킴을 알 수 있었다. 열교환기의 설계단계에서 사용하였던 열전달관계식으로 구한 총괄열전달계수, U와 실험값을 통해 유추한 U값을 비교한 결과 실험에 의해 유추된 U값이 $24{\sim}27%$ 설계치보다 크게 나타났다. 본 연구를 통하여 유출지하수 뿐만 아니라 하수 및 하천수를 이용한 지열히트펌프의 기초자료를 확보할 수 있었다.

  • PDF

Heat Transfer Performance of Pond Loop type Heat Exchanger for Ground Source Heat Pump using Extruding Ground Water (유출지하수 열원 지열히트펌프용 Pond Loop형 열교환기의 열전달 성능)

  • Park, Geun-Woo;Kim, Jin-Sang;Lee, Eung-Youl
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.445-450
    • /
    • 2006
  • 유출지하수나 지표수를 열원으로 하는 지열히트펌프의 기초자료로 활용하기 위하여 Pond Loop형 열교환기를 설계, 제작하여 유동이 없는 수조 내에서 수조의 온도가 변화함에 따라 일정한 열교환기 입구온도를 유지하면서 열전달량을 측정하였다. 그 결과 수조를 Heat Source로 사용하는 경우 $5,500{\sim}4,500kcal/h$의 열량이 전달되었고, 수조를 Heat Sink로 사용할 경우 $5,200{\sim}3,500 kcal/h$의 열량이 전달되었다. 또한 열교환기 관내 유속이 증가함에 따라 열전달량이 증가하는 경향성을 확인할 수 있었고, 이는 동시에 열교환기 입출구의 차압을 증가시킴을 알 수 있었다. 열교환기의 설계단계에서 사용하였던 열전달관계식으로 구한총괄열전달계수, U와 실험값을 통해 유추한U값을 비교한 결과 실험에 의해 유추된 U값이 $24{\sim}27%$ 설계치보다 크게 나타났다. 본 연구를 통하여 유출지하수 뿐만 아니라 하수 및 하천수를 이용한 지열히트펌프의 기초자료를 확보할 수 있었다.

  • PDF

The Air-stripping Process Conjugated with the Ultrasonic Treatment to Remove TOC in Groundwater around the LPG Underground Storage Cavern (탈기법과 초음파 처리법을 연계한 LPG 지하공동저장소 주변 오염지하수 내 TOC 제거)

  • Han, Yikyeong;Jun, Seongchun;Kim, Danu;Jeon, Soyoung;Lee, Minhee
    • Economic and Environmental Geology
    • /
    • v.55 no.5
    • /
    • pp.511-519
    • /
    • 2022
  • In order to develop an air-stripping based remediation process to remove the TOC (Total Organic Carbon) in groundwater around the underground LPG storage cavern, the laboratory scale experiments at various conditions (change of air injection volume and temperature, the application of ultrasonic treatment, etc.) for two types of groundwater (initial TOC concentration of 608 mg/L and 153 mg/L, respectively). From results of experiment, as the air injection rate for stripping into groundwater increased from 2 L/min to 11 L/min and as the air-stripping time increased from 1 hour to 24 hour, the TOC removal efficiency of air-stripping increased. However, the TOC concentration of treated groundwater was higher than the discharge tolerance limit (100 mg/L) even after 24 hour stripping at the maximum air injection rate of 11 L/min. The main compounds of the TOC in groundwater were identified as methanol and propane and the long stripping time (more than 24 hour) was needed to separate the methanol from groundwater because of the affinity between water and methanol. At 20℃ and 4 L/min of air injection, the TOC removal efficiency increased to 59.1% after 24 hour air-stripping. When the temperature of groundwater increased to 30℃ and 40℃, the TOC removal efficiency increased up to 80.0% and 82.8%, suggesting that more than 24 hour air-stripping at 40℃ is needed to lower the TOC concentration to below 100 mg/L and the additional TOC removal process as well as the air-stripping is necessary. When the temperature increased to 60℃ and the ultrasonic treatment was conjugated with the air-stripping, the TOC removal efficiency increased to 87.8% within 5 hour stripping and the final TOC concentration (72.4 mg/L) was satisfied with the TOC discharge tolerance limit. The TOC removal efficiency for groundwater having low TOC concentration (153 mg/L) also showed similar removal efficiency of 89.7% (the final TOC concentration: 18.9 mg/L). Results in this study supported that the air-stripping conjugated with the ultrasonic treatment could remove successfully the TOC in groundwater around the underground LPG strorage cavern.