• Title/Summary/Keyword: 지하수유동모델링

Search Result 98, Processing Time 0.022 seconds

Development of Methodology for Fracture Network Analysis in the Unsaturated Zone using MINC Approach in TOUGH2 Code (TOUGH2 전산코드의 MINC 기법을 이용한 불포화 암반 내 단열 해석 방법론 개발)

  • Ha, Jaechul;Cheong, Jae-yeol;Kim, Soogin;Yoon, Jeonghyoun
    • The Journal of Engineering Geology
    • /
    • v.26 no.3
    • /
    • pp.325-330
    • /
    • 2016
  • The second phase of low- and intermediate-level waste (LILW) disposal facility is under planned on the sedimentary rock in unsaturated zone. In this study, we created two meshes which were a matrix continuum mesh and a fracture continuum mesh to carry out 2 dimensional numerical modeling for groundwater flow in the unsaturated zone containing fractures focused on the second phase of LILW disposal facility. Two continuum meshes were developed using MINC in meshmaker module of TOUGH2 code. A fracture continuum mesh was included the k-field distribution of the permeability derived from the Discrete Fractured Network (DFN) modeling. To apply the unsaturated zone for the modeling, the gridding steps to generate mesh were developed. Each step to generate a mesh consisted of definition of materials, setting the initial conditions and creating grids using MINC. The methodology development of meshes in this study will be applied for more precise modeling of groundwater flow and mass transport.

Evaluation of Groundwater Level Decline and Water Quality Due to Tunnel Excavation (터널굴착으로 인한 지하수위 저하 및 수질영향 평가)

  • Kim, Min Gyu;Kim, Minsoo;Jeong, Gyocheol;Lee, Jeongwoo;Chung, Il-Moon
    • The Journal of Engineering Geology
    • /
    • v.29 no.2
    • /
    • pp.113-122
    • /
    • 2019
  • In this study, the flow analysis to evaluate the extent of groundwater decline and the effect of the small valleys caused by the decrease of groundwater level in the construction of road tunnel, and the pollutant movement analysis to evaluate pollution of nearby water source by pollutant discharge during tunnel construction, respectively. The decrease of the groundwater during the 30 month tunnel excavation period was maximum 27 m and it was found to be the largest within 50 m from the tunnel center. The flow of groundwater is shown in the form of flowing into the tunnels and the effects of groundwater level decline were observed up to a tunnel radius of 200 m. As a result of the numerical modeling of the contaminant transport to examine the influence of the polluted water discharge from the tunnel, the range of the turbid water generated at the end of the tunnel is up to 120 m and it is estimated that the risk of contamination of the small river is not large.

A Safety Assessment for the Wolsong LILW Disposal Center: As a part of safety case for the first stage disposal (월성원자력환경관리센터의 폐쇄후 처분안전성평가: 1단계 인허가 적용사례를 중심으로)

  • Park, Joo-Wan;Yoon, Jeong-Hyun;Kim, Chang-Lak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.4
    • /
    • pp.329-346
    • /
    • 2008
  • Post-closure safety assessment for the Wolsong Low- and Intermediate-level radioactive waste Disposal Center is described. Based on assessment context, closure concept and ground water flow characteristics of the disposal site, brief descriptions are included on the assessment scenarios, models, input parameters and tools. Radionuclide transport modeling in the near-field and far-field, gas generation and transport modeling, human intrusion and biosphere transport are also described briefly. Assessment results for each scenarios are shown to meet the performance criteria of regulatory body. Further and continuous efforts to improve the safety of disposal facility will be made during the construction and operational period.

  • PDF

Analysis of a Groundwater Flow System in Fractured Rock Mass Using the Concept of Hydraulic Compartment (수리영역 개념을 적용한 단열암반의 지하수유동체계 해석)

  • Cho Sung-Il;Kim Chun-Soo;Bae Dae-Seok;Kim Kyung-Su;Song Moo-Young
    • The Journal of Engineering Geology
    • /
    • v.16 no.1 s.47
    • /
    • pp.69-83
    • /
    • 2006
  • This study aims to evaluate a complex groundwater flow system around the underground oil storage caverns using the concept of hydraulic compartment. For the hydrogeological analysis, the hydraulic testing data, the evolution of groundwater levels in 28 surface monitoring boreholes and pressure variation of 95 horizontal and 63 vertical water curtain holes in the caverns were utilized. At the cavern level, the Hydraulic Conductor Domains(fracture zones) are characterized one local major fracture zone(NE-1)and two local fracture zones between the FZ-1 and FZ-2 fracture zones. The Hydraulic Rock Domain(rock mass) is divided into four compartments by the above local fracture zones. Two Hydraulic Rock Domains(A, B) around the FZ-2 zone have a relatively high initial groundwater pressures up to $15kg/cm^2$ and the differences between the upper and lower groundwater levels, measured from the monitoring holes equipped with double completion, are in the range of 10 and 40 m throughout the construction stage, indicating relatively good hydraulic connection between the near surface and bedrock groundwater systems. On the other hand, two Hydraulic Rock Domains(C, D) adjacent to the FZ-1, the groundwater levels in the upper and lower zones are shown a great difference in the maximum of 120 m and the high water levels in the upper groundwater system were not varied during the construction stage. This might be resulted from the very low hydraulic conductivity$(7.2X10^{-10}m/sec)$ in the zone, six times lower than that of Domain C, D. Groundwater recharge rates obtained from the numerical modeling are 2% of the annual mean precipitation(1,356mm/year) for 20 years.

Groundwater Flow Model of Igsan Area (익산 지역의 지하수 유동 모델)

  • Hamm, Se Yeong;Kim, Youn Ki
    • Economic and Environmental Geology
    • /
    • v.22 no.4
    • /
    • pp.381-393
    • /
    • 1989
  • Hydrogeological modelling was performed to evaluate groundwater flow system in Igsan Area. The study area extends over $790km^2$. The geology consists of Jurassic Daebo granite and gneissose granite and Precambrian metamorphic rocks. The capability of pumping yield is the highest in gneissose granite region among them due to comparatively thick weathered zone with thickness ranging from 10m to 25m. The Colorado State University Finite Difference Model was used for the model simulation. The model was divided into 28 rows and 31 columns with variable grid spacing. The model was calibrated under steady-state and unsteady-state conditions. In the steady-state simulation, the model results were compared with measured water table contours in September 1985 with determining hydraulic conductivities and net recharge rates during rainy season. Unsteady state simulation was done to know the aquifer response due to groundwater abstraction. The non- steady state calibration was conducted to determine the distribution and magnitudes of specific yields and discharge/recharge rates during dry season as matching water level altitudes in May 1986. The calibrated model was used to simulate water level vaiation caused by groundwater withdrawal and natural recharge from 1 October, 1985 until 30 September, 1995. The calibrated model can be used to groundwater development schemes on regional groundwater levels, but it cannot be used to simulate local groundwater level change at a specific site.

  • PDF

Defining the hydraulic excavation damaged zone considering hydraulic aperture change (수리적 간극변화를 고려한 수리적 굴착손상영역의 정의에 관한 연구)

  • Park, Jong-Sung;Ryu, Chang-Ha;Lee, Chung-In;Ryu, Dong-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.2
    • /
    • pp.133-141
    • /
    • 2007
  • The excavation damaged zone (EDZ) is an area around an excavation where in situ rock mass properties, stress condition, displacement, groundwater flow conditions have been altered due to the processes induced by the excavation. Various studies have been carried out on EDZ, but most studies have focused on the mechanical bahavior of EDZ by in situ experiment. Even though the EDZ could potentially form a high permeable pathway of groundwater flow, only a few studies were performed on the analysis of groundwater flow in EDZ. In this study, the 'hydraulic EDZ' was defined as the rock zone adjacent to the excavation where the hydraulic aperture has been changed due to the excavation by using H-M coupling analysis. Fundamental principles of distinct element method (DEM) were used in the analysis. In the same groundwater level, the behavior of hydraulic aperture near the cavern was analyzed for different stress ratios, initial apertures, fracture angles and fracture spacings by using a two-dimensional DEM program. We evaluate the excavation induced hydraulic aperture change. Using the results of the study, hydraulic EDZ was defined as an elliptical shape model perpendicular to the joint.

  • PDF

Use of a Temperature as a Tracer to Study Stream-groundwater Exchange in the Hyporheic Zone (열추적자를 이용한 지하수-하천수 혼합대 연구)

  • Kim, Kue-Young;Chon, Chul-Min;Kim, Tae-Hee;Oh, Jun-Ho;Jeoung, Jae-Hoon;Park, Seung-Ki
    • Economic and Environmental Geology
    • /
    • v.39 no.5 s.180
    • /
    • pp.525-535
    • /
    • 2006
  • A study on stream-groundwater exchange was performed using head and temperature data of stream water, streambed, and groundwater. Groundwater level and temperature were obtained from multi-depth monitoring wells in small-scale watershed. During the summer and winter season, time series of temperature data at streambed and groundwater were monitored for six months. In the winter time, we measured the temperature gradient between stream water and streambed. The observed data showed three typical types of temperature characteristics. First, the temperature of streambed was lower than that of stream water; second, the temperature of streambed and stream water was similar; and the last, the temperature of streambed was higher than that of stream water. The interconnections between the stream and the streambed were not homogeneously distributed due to weakly developed sediments and heterogeneous bedrock exposed as bed of the stream. The temperature data may be used in formal solutions of the inverse problems to estimate groundwater flow and hydraulic conductivity.

Sensitivity Analysis of a Transient Groundwater Flow Modeling for Tunnel Excavation (터널 굴착에 따른 지하수 유동계의 변화에 대한 수리상수들의 민감도 분석)

  • Jeong Bok- Seon;Koo Min-Ho;Kim Yongje;Lee Jin-Yong
    • The Journal of Engineering Geology
    • /
    • v.14 no.3 s.40
    • /
    • pp.287-300
    • /
    • 2004
  • By using a simple conceptual model, a sensitivity analysis is performed to examine the effects of changing model parameters on the model outputs, the groundwater discharge and the radius of influence, induced by tunnel construction. The results indicate that the model outputs are most sensitive to the tunnel depth and the hydraulic conductivity, and their sensitivities vary with time. It is also revealed that the sensitivity of the specific yield in- creases constantly with time, and therefore it is as important as the hydraulic conductivity for constructing a wet-system tunnel. A transient model is suggested to simulate the stepwise tunnel excavation and the watertight lining. The model is used for a tunnel construction site to predict groundwater mow into the tunnel and the transient response of the surrounding aquifer system. The predicted results are highly sensitive to the hydraulic conductivites assigned by model calibration. Thus, a postaudit should be made to reduce the uncertainty of the predictive model.

An Artificial Recharge Test and Its Numerical Simulation for the Analysis of Seepage in the Songsanri Tomb Site of Kongju (공주 송산리고분군 누수현상 원인 분석을 위한 인공함양시험 및 수치모델링)

  • 구민호;서만철
    • The Journal of Engineering Geology
    • /
    • v.9 no.1
    • /
    • pp.1-15
    • /
    • 1999
  • An artificial recharge test was performed to analyze the source of seepage observed inside the Songsanri tombs Kongju during the rainy season. In order to simulate simulate the test, a two-dimensional unsaturated groundwater flow model was developed. By the measured water level variation in the observation wells and in the artificail water tank, the model was cailbrated to estimate the model parameters such as fitting parameters in the constitutive relations(n and $\alpha$), the saturated volumetric water content, the residual volumetric water content, and the saturated hydraulic conductivity. Using the calibrated parameters, the recharge test was simulated. The results of the test and simulation show that the major source of the seepage is the downward groundwater flow through cracks in the protection layer the tombs. It was also analyzed by the steady state simulation that, with a perfect protection layer, a long-term precipitation that, with a perfect protection layer, a long-term precitation could cause only 10% increase of the effective saturation around the north side of the Muryong royal tomb by infiltration of the unsaturated groundwater from the North. Therefore, it is concluded that the most urgent protection plan for the tombs with respect to seepage is to reconstruct an effective waterproof-layer rather than a trenched drainage system.

  • PDF

Hydrogeological Stability Study on the Underground Oil Storage Caverns by Numerical Modeling (수치모델링을 이용한 지하원유비축시설의 수리지질학적 안정성 연구)

  • 김경수;정지곤
    • The Journal of Engineering Geology
    • /
    • v.12 no.1
    • /
    • pp.35-51
    • /
    • 2002
  • This study aims to establish the methodology for design of an optimum water curtain system of the unlined underground oil storage cavern satisfying the requirements of hydrodynamic performance in a volcanic terrain of the south coastal area. For the optimum water curtain system in the storage facility, the general characteristics of groundwater flow system in the site are quantitatively described, i.e. distribution of hydraulic gradients, groundwater inflow rate into the storage caverns, and hydrogeologic influence area of the cavern. In this study, numerical models such as MODFLOW, FracMan/MAFIC and CONNECTFLOW are used for calculating the hydrogeological stability parameters. The design of a horizontal water curtain system requires considering the distance between water curtain and storage cavern, spacing of the water curtain boreholes, and injection pressure. From the numerical simulations at different scales, the optimum water curtain systems satisfying the containment criteria are obtained. The inflow rates into storage caverns estimated by a continuum model ranged from about 120 m$^3$/day during the operation stage to 130~140m$^3$/day during the construction stage, whereas the inflow rates by a fracture network model are 80~175m$^3$/day. The excavation works in the site will generate the excessive decline of groundwater level in a main fracture zone adjacent to the cavern. Therefore, the vertical water curtain system is necessary for sustaining the safe groundwater level in the fracture zone.