A Safety Assessment for the Wolsong LILW Disposal Center: As a part of safety case for the first stage disposal

월성원자력환경관리센터의 폐쇄후 처분안전성평가: 1단계 인허가 적용사례를 중심으로

  • Park, Joo-Wan (Nuclear Engineering & Technology Institute, Korea Hydro & Nuclear Power Co., Ltd.) ;
  • Yoon, Jeong-Hyun (Nuclear Engineering & Technology Institute, Korea Hydro & Nuclear Power Co., Ltd.) ;
  • Kim, Chang-Lak (Nuclear Engineering & Technology Institute, Korea Hydro & Nuclear Power Co., Ltd.)
  • 박주완 (한국수력원자력(주) 원자력발전기술원) ;
  • 윤정현 (한국수력원자력(주) 원자력발전기술원) ;
  • 김창락 (한국수력원자력(주) 원자력발전기술원)
  • Published : 2008.12.31

Abstract

Post-closure safety assessment for the Wolsong Low- and Intermediate-level radioactive waste Disposal Center is described. Based on assessment context, closure concept and ground water flow characteristics of the disposal site, brief descriptions are included on the assessment scenarios, models, input parameters and tools. Radionuclide transport modeling in the near-field and far-field, gas generation and transport modeling, human intrusion and biosphere transport are also described briefly. Assessment results for each scenarios are shown to meet the performance criteria of regulatory body. Further and continuous efforts to improve the safety of disposal facility will be made during the construction and operational period.

중저준위 방사성폐기물의 영구처분을 위하여 건설되는 월성원자력환경관리센터의 1단계 폐쇄후 안전성평가에 대하여 기술하였다. 처분시설의 건설운영허가를 위하여 작성된 안전성평가에 대하여 평가개요, 처분시설의 폐쇄개념, 처분부지에 대한 지하수 유동특성을 이용하여 평가를 위한 시나리오의 개발과정과 도출된 평가대상 시나리오에 대한 개념을 기술하였다. 폐쇄후 안전성평가 모델링을 위한 평가도구, 입력인자와 개별 시나리오에 대한 핵종누출 모델링, 기체발생 및 기체이동 모델링, 인간침입 모델링과 생태계 모델링에 대하여 기술하였다. 처분시설의 폐쇄후 안전성 평가시나리오에 대하여 국내 규제치를 만족하는 것으로 평가되었으며 향후 처분시설 안전성에 대한 불확실성 저감과 신뢰성 증진을 위한 노력을 지속적으로 수행할 예정이다.

Keywords