• Title/Summary/Keyword: 지진증폭

Search Result 172, Processing Time 0.023 seconds

Analytical Study on Viscoelastic Damper System with Displacement-Amplification Unit (변위증폭형 점탄성 댐퍼시스템에 관한 해석적 연구)

  • Son, Young-Seon;Choi, Ki-Sun;You, Young-Chan;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.205-206
    • /
    • 2009
  • This study deals with the viscoelastic damper system with displacement-amplification unit (DAU) which can maximize the effectiveness of a damper system in controlling seismic response of a building by amplifying story drift induced to damper. DAUs in this study were analyzed to be able to amplify the displacement 2 to 4 times greater than the original story drift. The efficiency of each DAU was expressed by $\beta$ (DAU ratio) and examined in this analytical study.

  • PDF

Earthquake Engineering Bedrock Based on the Shear Wave Velocities of Rock Strata in Korea (국내 암반지층의 전단파속도에 근거한 지진공학적 기반암 결정)

  • Sun, Chang-Guk
    • The Journal of Engineering Geology
    • /
    • v.24 no.2
    • /
    • pp.273-281
    • /
    • 2014
  • In most current seismic design codes, design earthquake ground motions are defined by a reference spectrum, based on bedrock and site amplification factors that quantify the geotechnical dynamic conditions. Earthquake engineering bedrock is the fundamental geotechnical formation where the seismic waves are attenuated without amplification. To better define bedrock in an earthquake engineering context, shear wave velocity ($V_S$ ) data obtained from in-situ seismic tests were examined for several rock strata in Korea; these data were categorized by borehole drilling investigations. The $V_S$ values for most soft rock data in Korea are > 750 m/s, which is the threshold $V_S$ value for identifying engineering bedrock from a strong motion station. Conversely, VS values are < 750 m/s for 60% of $V_S$ data in weathered rock in Korea. Thus, the soft (or harder) rock strata below the weathered rock layer in Korea can be regarded as earthquake engineering bedrock.

Estimation of Site Effects at Hongsung Based on 2-Dimensional Basin Modeling within Spatial Geotechnical Information System (공간 지반 정보 시스템을 활용한 2차원 분지 모델링 기반의 홍성 지역 부지 효과 평가)

  • Sun, Chang-Guk;Choo, Yun-Sik;Chung, Choong-Ki
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.253-256
    • /
    • 2008
  • 지하 토사 조건 및 지질 구조는 지진 시 지반 운동의 증폭에 관련된 부지 효과에 매우 큰 영향을 미친다. 본 연구에서는 국내 홍성 지역을 대상으로 시추 조사와 현장 탄성파 시험을 포함한 현장 조사 및 지표 부근지질 정보를 획득하기 위한 부지 답사를 통해 부지 효과를 확인하였다. 홍성 지역은 1978년 계기 지진이 발생한 지역으로서 기반암 상부에 최대 약 50 m 두께의 풍화대 지층이 분포한다. 연구 대상 지역의 공간 지층 구조를 효율적으로 확인하기 위하여 지리정보시스템(GIS) 기법 기반의 지반 정보 시스템(GTIS)의 구축하였으며, 홍성 지역은 분지는 얕고 넓은 형상임을 확인하였다. 홍성 지역의 부지 지진 응답을 평가하기 위하여 대표 단면에 대한 2차원 유한 요소 해석을 수행하였다. 도출된 지진 응답으로부터 지반 운동이 기반암 상부 토사층을 통해 전단파가 전파되면서 증폭되고 분지 형상에 따른 전단파의 상호 작용으로 생성된 표면파로 인해 분지 경계 부근 진동 지속 시간이 증가됨을 확인하였다. 뿐만 아니라, 분지 내의 선정된 토사 부지들에 대해서 추가적인 1차원 유한 요소 지진 응답 해석을 수행하였으며, 본 연구 대상 분지가 매우 얕고 넓음에 따라 분지 경계 부근을 제외하고는 분지 내 대부분의 위치에서 2차원 지진 응답과 유사한 결과를 보였다.

  • PDF

Verification of the Torsional Amplification Factor for the Seismic Design of Torsionally Imbalanced Buildings (비틀림 비정형 건물의 내진설계를 위한 우발편심 비틀림 증폭계수 검증)

  • Lee, Kwang-Ho;Jeong, Seoung-Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.6
    • /
    • pp.67-74
    • /
    • 2010
  • Because of the difference between the actual and computed eccentricity of buildings, symmetrical buildings will be affected by torsion. In provisions, accidental eccentricity is intended to cover the effect of several factors, such as unfavorable distributions of dead- and live-load masses and the rotational component of ground motion about a vertical axis. The torsional amplification factor is introduced to reduce the vulnerability of torsionally imbalanced buildings. The effect of the torsional amplification factor is observed for a symmetric rectangular building with various aspect ratios, where the seismic-force-resisting elements are positioned at a variable distance from the geometrical center in each direction. For verifying the torsional amplification factor in provisions, nonlinear reinforced concrete models with various eccentricities and aspect ratios are used in rock. The difference between the maximum displacements of the flexible edge obtained between using nonlinear static and time-history analysis is very small but the difference between the maximum torsional angles is large.

Evaluation of Acceleration Amplification Factors Based on the Structural Type of Substation for the Seismic Design of Power Facilities (전력설비의 내진설계를 위한 변전소 구조형식에 따른 가속도 증폭계수의 평가)

  • Park, Seong-Jae;Chun, Nakhyun;Hwang, Kyeong-Min;Moon, Jiho;Song, Jong-Keol
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.3
    • /
    • pp.159-169
    • /
    • 2020
  • Acceleration amplification factors, which are variables used in the seismic design of power facilities installed inside substation structures, are presented in the seismic design standards of the United States (US), Japan, and Korea. Unlike the coefficients presented in the design standards of the US and Japan, those presented in domestic design standards can be obtained only by performing dynamic analysis when the substation structure has more than four floors. Because most substation structures in Korea have 4-5 stories, the existing acceleration amplification factor is insufficient to be applied to actual substation structures. To suggest an acceleration amplification factor suitable for domestic substation structure types, the acceleration amplification factor was evaluated for seven representative substation structures. The acceleration amplification factors were evaluated by constructing in-structure response spectra based on a study of far-field and near-fault earthquakes. In general, the acceleration amplification coefficients αJ and αA according to the US and Japan seismic design criteria tend to be overestimated compared with the acceleration amplification factors obtained through dynamic analysis based on the study of near-fault and far-field earthquakes.

Application of Vibration Prediction Method Using Response Spectrum with Amplification Factor (증폭계수를 이용한 진동 예측기법의 적용)

  • 심재수;황의승;김덕중;윤종오
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.4
    • /
    • pp.37-43
    • /
    • 1997
  • Damages and public complaints are increased due to construction noise and vibration from several sources. It is urgently needed to develop the easy and practical method to estimate the vibration effect. In this study, to predict the vibration effect, the method using the response spectrum with amplification factor concepts prroposed by Newmark and Hall is used. Also the applicability of the method is examined. Vibration measurement on subway structure, foundation and building structures are performed and the results show that the provided method is practical and can be used to predict the vibration effect.

  • PDF

The Site Effect of the Broadband Seismic Stations in Korea (국내 광대역 지진 관측소의 부지효과)

  • Wee, Soung-Hoon;Kim, Sung-Kyun
    • Economic and Environmental Geology
    • /
    • v.41 no.2
    • /
    • pp.225-242
    • /
    • 2008
  • The site effect for 23 broadband seismic stations in the southern Korean Peninsula was estimated by using the spectral ratio of coda waves. In principle, the site effect means the pure amplification below the station excluding effects of seismic source and attenuation in the wave transmission. However, the site effect determined in this study is equivalent with the relative site amplification factor to the mean amplification for all stations. A total of 500 three-component seismograms from 35 earthquakes, of which magnitude ranged from 2.5 to 5.1 occurred from January, 2001 to January, 2007 was used to obtain the site amplification factor. The site amplification factors were estimated for the frequency bands centered at 0.2, 0.5, 1, 2, 5, 10, 15, and 20 Hz. It was found that the factors for two horizontal components of transverse and radial records were concordant with each other in the all frequency bands. However, the factor for the vertical component was found to be systematically lower than those for two horizontal components. The factors obtained in the low frequency band below 2 Hz ranged from 0.5 to 1.5 in all seismic stations except for KMA and KIGAM stations in Bagryeongdo (BRD1 and BRD2) of which factor showed high value above 1.5. Some stations such as SEO, SNU, HKU, NPR, and GKPI showed high value above 1.5 in the high frequency band from 5 to 20 Hz. Especially, the factors of GKP1 station represented extremely high value ranging from 1.8 to 7.8. Also, the factors for stations of KWJ, SND, and ULJ showed low value below 0.5. The spatial distribution for the relative amplification factor represented a tendency of being approximately lower in north-eastern area than south-western area in the southern Korean Peninsula.

INELASTIC RESPONSE SPECTRA CONSIDERING THE NONLINEARITY OF THE SOFT SOIL DUE TO THE WEAK SEISMIC EXCITATIONS (약진에 의한 연약지반의 비선형성을 고려한 비탄성 응답스펙트럼)

  • Kim, Yong-Seok
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.249-258
    • /
    • 2003
  • 강진을 고려한 지진설계 규준은 약진지역에서는 불필요한 경제적 손실을 가져올 수 있고, 지반-구조물 상호작용을 고려한 성능기준 설계가 합리적인 지진설계를 위해서 중요하다는 것이 인식되었다. 이 연구에서는 연약지반 위에 놓인 단자유도계의 탄성, 비탄성 지진응답 해석을 지반의 비선형성을 고려하여 최대지진가속도를 0.07g와 0.11g로 조정한 11개 중, 약진에 대해 수행하였다. 지진 응답해석은 지반-구조물체계에 대해 유사 3차원 동적해석 프로그램으로 암반에 지진기록을 입력하여 한 단계에 일괄적으로 수행하였다. 연구 결과에 의하면 고정지반이나 선형지반을 가정한 지진응답 스펙트럼은 구조물-지반체계의 실제적인 거동을 보여주지 못하는 것으로 나타났으며, 합리적인 지진설계를 위해서는 지진규준에 정해진 일상적인 설계절차에 따라서 수행하는 것보다 다른 성질을 가진 여러 지반에 대해서 성능기준 지진설계를 수행하는 것이 필요하다. 약진을 받는 연약지반의 비선형성도 입력지진동을 증폭시켜 탄성, 비탄성 지진응답 스펙트럼에 심하게 영향을 미쳤으며, 그 현상은 특히 탄성 응답스펙트럼에서 두드러졌다.

  • PDF

Real-time Seismic Damage Estimation for Harbor Site Considering Ground Motion Amplification Characteristics (항만지역의 지반증폭 특성을 반영한 실시간 지진피해 평가방안 수립)

  • Kim, Han-Saem;Yoo, Seung-Hoon;Jang, In-Sung;Chung, Choong-Ki
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.5
    • /
    • pp.55-65
    • /
    • 2012
  • The purpose of this study is to estimate seismic damage for harbor site considering dynamic amplification characteristics. First of all, a series of ground response analysis is performed and then correlation equations between rock outcrop accelerations and peak ground accelerations (PGAs) are determined. These equations are saved into DB and when an earthquake occurs, PGAs are determined by them as soon as possible. For earthquake events, seismic damage grades of harbor structures are determined by using the correlated PGAs and fragility curves of harbor structures in real time. In this study, seismic damage was estimated and classified into several grades by applying two hypothetical earthquakes.