• Title/Summary/Keyword: 지진증폭

Search Result 172, Processing Time 0.023 seconds

Double Integration of Measured Acceleration Record using the Concept of Modified Wavelet Transform (수정된 웨이블릿 변환 개념을 이용한 계측 가속도 기록의 이중 적분법)

  • 이형진;박정식
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.5
    • /
    • pp.11-17
    • /
    • 2003
  • It is well known that the double integration of measured acceleration records is one of the most difficult signal processing, particularly in the measurements on civil engineering structures, The measured accelerations of civil engineering structures are usually non-stationary and contain non-gaussian low-frequency noises, which can be significant causes of numerical instabilities in double Integration, For the de-noising of this kind of signals, wavelet transform can be very effective because of its inherent processing features for non-stationary signals, In this paper, the de-noising algorithm for the double integration is proposed using the modified wavelet transform, which is extended version of ordinary wavelet transform to process non-gaussian and low-frequency noises, using the median filter concept, The example studies show that the integration can be improved by the proposed method.

Approximate Analysis for Shear Force Amplification Effect in Ordinary RC Shear Walls (철근콘크리트 보통전단벽의 전단력 증폭효과 근사해석)

  • Jeon, Seong-Ha;Park, Ji-Hun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.3
    • /
    • pp.129-139
    • /
    • 2020
  • An approximate analysis method is proposed to predict the dynamic amplification of shear forces in ordinary reinforced concrete shear walls as a preliminary study. First, a seismic design for three groups of ordinary reinforced concrete shear walls higher than 60 m was created on the basis of nonlinear dynamic analysis. Causes for the dynamic amplification effect of shear forces were investigated through a detailed evaluation of the nonlinear dynamic analysis result. A new modal combination rule was proposed on the basis of that observation, in which fundamental mode response and combined higher mode response were summed directly. The fundamental mode response was approximated by nonlinear static analysis result, while higher mode response was computed using response spectrum analysis for equivalent linear structural models with the effective stiffness based on the nonlinear dynamic analysis result. The proposed approximate analysis generally predicted vertical distribution of story shear and shear forces of individual walls from the nonlinear dynamic analysis with comparable accuracy.

Modification of Site Classification System for Amplification Factors considering Geotechnical Conditions in Korea (국내 지반 특성에 따른 합리적 증폭 계수의 결정을 위한 지반 분류 체계 개선 방안 고찰)

  • Sun, Chang-Guk;Chung, Choong-Ki;Kim, Dong-Soo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.90-101
    • /
    • 2005
  • For the site characterization at two representative inland areas, Gyeongju and Hongsung, in Korea, in-situ seismic tests containing boring investigations and resonant column tests were performed and site-specific ground response analyses were conducted using equivalent linear as well as nonlinear scheme. The soil deposits in Korea were shallower and stiffer than those in the western US, from which the site classification system and site coefficients in Korea were derived. Most sites were categorized as site classes C and D based on the mean shear wave velocity to 30 m, Vs30 ranging between 250 and 650 m/s. Based on the acceleration response spectra determined from the site-specific analyses, the site coefficients specified in the Korean seismic design guide underestimate the ground motion in the short-period band and overestimate the ground motion in mid-period band. These differences can be explained by the differences in the bedrock depth and the soil stiffness profile between Korea and western US. The site coefficients were re-evaluated and the preliminary site classification system was introduced accounting for the local geologic conditions on the Korean peninsula.

  • PDF

Analysis of H/V Ratio using Recent Earthquake (국내관측소의 부지 증폭특성 연구)

  • Yoo, Seong-Hwa;Oh, Tae-Seok;Kim, Jun-Kyoung
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.175-180
    • /
    • 2006
  • The horizontal to vertical ratio technique in spectral domain is a common useful technique to estimate empircal site transfer function. The technique, originally proposed by Nakamura, is porposed to analyse the surface waves in the micortremor records. The purpose of this paper is to estimate spectral ratio using observed data at the seismic stations in Korean Peninsula from the Fukuoka earthquake including many aftershocks. The results show that most of the stations have fairly good amplification factors. However, some of the stations show that very high amplification factors at narrow high frequency band. Those stations which have very high amplification factors seem to do some kind of mechanical consideration for quality observation.

  • PDF

A New Detailed Assessment for Liquefaction Potential Based on the Liquefaction Driving Effect of the Real Earthquake Motion (실지진하중의 액상화 발생특성에 기초한 액상화 상세평가법)

  • 최재순;강한수;김수일
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.5
    • /
    • pp.145-159
    • /
    • 2004
  • The conventional method for assessment of liquefaction potential proposed by Seed and Idriss has been widely used in most countries because of simplicity of tests. Even though various data such as stress, strain, stress path, and excess pore water pressure can be obtained from the dynamic test, especially, two simple experimental data such as the maximum deviatoric stress and the number of cycles at liquefaction have been used in the conventional assessment. In this study, a new detailed assessment for liquefaction potential to reflect both characteristics of real earthquake motion and dynamic soil resistance is proposed and verified. In the assessment, the safety factor of the liquefaction potential at a given depth of a site can be obtained by the ratio of a resistible cumulative plastic shear strain determined through the performance of the conventional cyclic test and a driving cumulative plastic shear strain calculated from the shear strain time history through the ground response analysis. The last point to cumulate the driving plastic shear strain to initiate soil liquefaction is important for this assessment. From the result of cyclic triaxial test using real earthquake motions, it was concluded that liquefaction under the impact-type earthquake loads would initiate as soon as a peak loading signal was reached. The driving cumulative plastic shear strain, therefore, can be determined by adding all plastic shear strains obtained from the ground response analysis up to the peak point. Through the verification of the proposed assessment, it can be concluded that the proposed assessment for liquefaction potential can be a progressive method to reflect both characteristics of the unique soil resistance and earthquake parameters such as peak earthquake signal, significant duration time, earthquake loading type, and magnitude.

Effect of the Soft Soil Layer on the Vertical Response of a Structure Excited with the Vertical Component of Earthquakes (연약지반이 수직방향 지진하중을 받는 구조물의 수직방향 반응에 미치는 영향)

  • 김용석
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.1
    • /
    • pp.113-122
    • /
    • 1999
  • The importance of the vertical response of a structure was well recognized after the Hyogoken-Nanbu earthquake of Japan. However, most of the seismic design codes does not specified the site sail profiles, and the sail and foundations conditions were mostly neglected in the vertical seismic analyses of a structure. In this paper, the effects of foundation size, sail layer depth under the foundation, foundation embedment and pile foundation on the vertical seismic response spectra for both surface and embedded mat foundation were studied to investigate the effects of the soft soil layer on the vertical response of a structure excited with the vertical components of Taft and El Centro earthquakes, considering the sail profile types of $S_A,S_C,S_E$ in UBC-97, the medium and large size foundations, the soil layer depth under the foundation of 30 and 60m, the foundation embedment of 0 and 15m, and the precast reinforced concrete bearing piles installed in the soft soil deposit. According to the study results, the foundation size has a little effect on the vertical seismic response, However, the soil layer depth under the foundation of 60m has to be considered for the vertical seismic analysis of a structure as for the horizontal one. The embedded pile foundations as well as the surface ones built on the soft soil layer amplified the vertical seismic response of a structure very much.

  • PDF

Amplification Characteristics of Domestic and Overseas Intraplate Earthquake Ground Motions in Korean Soil and Standard Horizontal Design Spectrum for Soil Sites (국내외 판내부 지진기록을 사용한 국내 지반의 지반운동 증폭특성 규명 및 토사지반의 표준설계응답스펙트럼의 제안)

  • Lee, Jin Ho;Kim, Jung Han;Kim, Jae Kwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.7
    • /
    • pp.391-399
    • /
    • 2018
  • The site coefficients in the common requirements for seismic design codes, which were promulgated in 2017, were reevaluated and the standard design spectrum for soil sites were newly proposed in order to ensure the consistency of the standard design spectra for rock and soil sites specified in the common requirements. Using the 55 ground motions from domestic and overseas intraplate earthquakes, which were used to derive the standard design spectrum for rock sites, as rock outcropping motions, site response analyses of Korean soil were performed and its ground-motion-amplification was characterized. Then, the site coefficients for soil sites were reevaluated. Compared with the existing site coefficients, the newly proposed short-period site coefficient $F_a$ increased and the long-period site coefficient $F_v$ decreased overall. A new standard design spectrum for soil sites was proposed using the reevaluated site coefficients. When compared with the existing design spectrum, it could be seen that the proposed site coefficients and the standard design spectrum for soil sites were reasonably derived. They reflected the short-period characteristics of earthquake and soil in Korea.

Effect of Skirt Length on Behavior of Suction Foundations for Offshore Wind Turbines Installed in Dense Sand Subjected to Earthquake Loadings (조밀한 모래지반에 설치된 해상풍력 석션기초의 스커트길이에 따른 지진하중시 거동특성)

  • Choo, Yun Wook;Olalo, Leonardo;Bae, Kyung-Tae
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.28 no.4
    • /
    • pp.202-211
    • /
    • 2016
  • This study aims to analyze seismic responses of suction foundations for offshore wind turbine. For this purpose, dynamic centrifuge model tests were carried out. The skirt length of the suction foundation is a critical element for bearing mechanism against environmental loads. Thus, dynamic centrifuge model tests were performed and analyzed for three suction foundation models with the ratios of skirt length to suction foundation diameter of 0.5, 0.75, and 1 installed in dense sand. As results, the acceleration amplification at the suction foundation, residual settlement, and residual tilting angle were compared.

Dynamic Responses of Base Isolation Devices for Telecommunication Equipment in Building Structures (건축물 내 방송통신설비를 위한 면진장치의 동적거동)

  • Jeong, Saebyeok;Choi, Hyoung-Suk;Seo, Young-Deuk;Jung, Donghyuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.39-48
    • /
    • 2022
  • In earthquake situations, broadcasting and communication services are directly linked to rapid on-site rescue and effective restoration works. Recently, a variety of base isolation devices are widely introduced on building floors to avoid critical seismic damages of telecommunication facilities. However, in buildings with long fundamental periods, those devices may have undesirable amplification of seismic responses due to resonance effect between the building floors and base isolation devices. This study performs the seismic safety evaluation of two types of base isolation devices deployed for telecommunication facilities in mid- and high-rise buildings through numerical and experimental approaches. It is found that mid- and high-rise buildings can have low-frequency dynamic responses at the top floor when being subjected to design basis earthquake loading. Furthermore, bi-directional shake table testing demonstrated that the selected base isolation devices can exhibit unstable dynamic behaviors under such low-frequency excitations of the floor.

A Study of Displacement Amplification Factors Considering Hysteretic Behavior of Structural Systems and Earthquake Characteristics (비탄성 이력응답 및 지진특성을 반영한 변위증폭계수에 관한 연구)

  • Song, Jong-Keol;Kim, Hark-Soo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.777-782
    • /
    • 2007
  • Displacement amplification factor can be used to estimate inelastic displacement demands from elastic displacement demands, The simple formula for displacement amplification factor considering hysteretic behavior of structural system and earthquake characteristics is proposed. And the effects of several parameters such as displacement ductility, strain hardening ratio, period, characteristics of earthquakes and hysteretic models for the displacement amplification factor are evaluated. Accuracy of the proposed formula is evaluated by comparing the displacement amplification factors estimated by existing and proposed formula with those calculated from inelastic time history analysis. The displacement amplification factors by proposed formulas provide a good agreement with those calculated by inelastic time history analysis.

  • PDF