• Title/Summary/Keyword: 지진성능평가

Search Result 734, Processing Time 0.022 seconds

Retrofit Measures Based on Seismic Retrofit Priority of Existing Bridges (교량의 내진보강 우선순위를 이용한 합리적인 보강방안 선정기법)

  • Lee, Sang-Woo;Kim, Sang-Hyo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.3
    • /
    • pp.77-86
    • /
    • 2004
  • The retrofit priority of existing and retrofitted bridges is examined and compared to determine effectively the seismic retrofit method of bridges. For the retrofit prioritization of bridges a quantitative procedure is proposed firstly based on seismic damage probabilities and total failure cost due to the damage of seismic vulnerable components. Using the proposed procedure, the retrofit priority of four typical girder-type bridges is determined. In addition, the ranking indices of bridges retrofitted by steel jackets and cable restrainers are revaluated for comparing with the results of existing bridges. Application of retrofitting method can considerably decreases damage possibilities of retrofitted components but may increases those of adjacent vulnerable components. Therefore, the seismic retrofitting effects based on the global motions of existing and retrofitted bridges should be examined to determine efficiently the retrofitting method. For evaluating the retrofitting effects the ranking indices obtained from the proposed procedure is found to be utilized effectively.

Seismic Safety Assessment of Long Period Structures Base on Elastic/Inelastic Response Characteristics (장주기구조물의 탄소성응답특성을 고려한 지진안전성 평가)

  • Bang, Myung-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.3
    • /
    • pp.52-58
    • /
    • 2011
  • The earthquake characteristic assessment of social overhead facilities would be an important examination issue for seismic capacity enhancement. This study is intended to reasonably evaluate the structural behavior of longperiod frame structures considering near-fault and far-fault earthquake characteristics. Elastic/inelastic time history analyses were performd by selecting the objective structure which can precisely reflect the effect of input ground motion. Based on the result of numerical analysis, we have investigated response aspects of shear force, moment, acceleration and displacement according to earthquake characteristics. Moreover, in order to understand the inelastic behavior of the objective structure, we have analyzed and compared collapse modes by considering the occurrence process of plastic hinges. The outcome of this research is expected to provide the basic information for the seismic safety assessment of long-period frame structures.

Testing Procedures to Examine the Characteristics of LRBs (지진격리장치(LRB)의 특성검사방법)

  • 강형택;이민구;이창근;서주원
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.401-408
    • /
    • 2002
  • 교량의 건설에 있어서 내진설계가 주요문제로 부각되면서, LRB(Lead Rubber Soaring)가 한 방법으로 사용되고 있다. 특히, 설계변경 또는 내진보수.보강과 같이 제약 조건이 있는 상황에서 유용한 면진방법으로 적용된 사례를 찾아 볼 수 있다. 이와 같이 LRB의 사용이 증가함에도 불구하고, 그 특성을 엄밀히 검증할 수 있는 시험기준이 정립되어 있지 않다. 따라서, 실무에서 LRB를 사용하는 경우 많은 혼란이 발생하고 있으며, 구조물의 면진성능에 대한 신뢰성도 떨어뜨리고 있다. 본 연구에서는 실무에서 발생하는 혼란과 LRB의 성능에 대한 불확실성을 줄이기 위하여 특성시험 기준을 정립하였다. 특성시험 기준은 미국 HITEC의 면진장치 특성시험 기준과 일본의 시험 기준을 토대로 국내 시방서와 시공 및 설계환경에 적합한 기준을 제시하고자 한다. 특성시험절차는 LRB의 연직강성, 수평유효강성, 감쇠비, 내구성 등 총 8개 항목에 대하여 정리하였다. 이 절차에 따라, 본 연구에서 실험이 수행 될 것이며, 시험 결과를 분석.평가한 후 세부사항을 재검토하여 실무에서 유용하게 사용할 수 있는 기준을 제시하고자 한다.

  • PDF

Finite Element Analysis of 2ply Bellows Expansion Joint based on Cyclic Loading Test (2ply 벨로우즈 신축관이음의 반복하중 실험 기반 유한요소 해석)

  • Son, Ho-Young;Jeon, Bub-Gyu;Lee, Sang-Woo;Ju, Bu-Seog
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2022.10a
    • /
    • pp.311-312
    • /
    • 2022
  • 최근 발생한 경주 및 포항 지진으로 인해 다수의 매립배관 손상이 보고되었다. 벨로우즈 신축관이음은 기하학적 특성으로 인해 진동 및 침하 등으로 인한 손상을 저감시킬 수 있다. 벨로우즈 신축관이음관의 내진 성능평가에 대한 실험적 혹은 해석적 연구는 미미한 상황이다. 본 연구는 벨로우즈 신축이음관의 내진성능을 분석하기 위해 반복하중 기반의 실험적 연구를 수행하였다. 또한 실험결과를 기반으로 3차원 유한요소 모델을 구축하였으며 실험과 해석에서 얻어진 하중-변위 관계를 비교하였다. 해석 모델에서 전체적인 강성이 큰 것으로 나타났으며 최대 변위가 작용할 때 에너지 소산량은 약 10% 가량 큰 것으로 나타났다.

  • PDF

Response Characters of Bridge Adopting StLRB (StLRB 지진격리장치를 적용한 교량의 거동특성과 비교분석)

  • Choi, Seung-Ho;Han, Kyoung-Bong;Park, Sun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.1
    • /
    • pp.139-146
    • /
    • 2004
  • In this paper, the seismic analysis and the modeling techniques have been introduced for seismic performances assessment, when seismic isolation bearings are applied to a real bridge. Nonlinear time-history analysis is carried out using finite element analysis program. El Centro earthquake(1940, N00W) used as earthquake ground excitations. The seismic response of seismically isolated bridge is compared with that of a bridge using conventional Pot Bearings, after obtaining the displacements of the deck, the deformations of the piers, shear forces and moments of the bottoms of the piers. The analytical analysis results show that seismic isolation bearing, especially seismic isolation bearings with sliding mechanism, could reduce earthquake forces.

Evaluation of Capacity Spectrum Methods for Seismic Fragility Analysis of Bridges (교량의 지진 취약도 해석 시 사용되는 성능 스펙트럼 기법의 평가)

  • Kim, Sang-Hoon;Yi, Jin-Hak;Kim, Ho-Kyung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.67-76
    • /
    • 2004
  • This study presents the evaluation of CSM(Capacity Spectrum Method, ATC-40) in developing fragility curves for a sample concrete bridge. The CSM is originally developed as one of the simplified procedures for building structures, while this study adopts the CSM to develop fragility curves of bridge structures. Four(4) different approaches are demonstrated and the fragility curves developed are compared those by the nonlinear time history analysis. Fragility curves in this study are represented by lognormal distribution functions with two parameters and developed as a function of PGA. The sixty(60) ground acceleration time histories for the Los Angeles area developed for the Federal Emergency Management Agency (FEMA) SAC(SEAOC-ATC-CUREe) steel project are used for the bridge analysis. The comparison of fragility curves by the CSM with those by the time history analysis indicates that the agreement is excellent for one of the methods investigated in this study. In this respect. it is recommended that the demand spectrum might be improved according to the guidelines suggested in this study. However, this observation might not always apply, depending on the details of specific bridge characteristic

Mechanical Characteristic Analysis of Coil Spring & Viscous Damper (Coil Spring & Viscous Damper System의 동특성분석)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.2 s.54
    • /
    • pp.19-26
    • /
    • 2007
  • This paper presents the results of experimental studies of the mechanical characteristics of the Coil Spring and Viscous Damper system. The Coil Spring and Viscous Damper systems were selected for the isolation of Emergency Diesel Generator (EDG) which is located in Nuclear Power Plant (NPP). The Coil Spring and Viscous Damper systems were developed for the operating vibration isolation and seismic isolation for scaled Model EDG System. The damping properties of the viscous damper changes as the variation of velocity. Through this research nonlinear damping characteristics and the effective stiffness of coil spring and viscous damper system were evaluated.

Seismic Performance Evaluation of Inverted V Braced Steel Frames with Considering P-Δ Effects: A Case Study (P-Δ 효과를 고려한 역 V형 철골 가새골조의 내진성능평가: 사례연구)

  • Lee, Cheol-Ho;Kim, Jeong-Jae
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.3
    • /
    • pp.97-103
    • /
    • 2004
  • Most of the columns in centrally braced steel frame buildings are usually designed as the gravity columns to reduce connection cost. For a rational seismic performance evaluation of centrally braced steel frame buildings, it is important to properly incorporate in the analysis  the P-${\Delta}$ effects arising from the gravity columns. An effective scheme for the P-${\Delta}$ effects modeling due to the gravity columns was illustrated based on the concept of fictitious leaning column. Seismic performance evaluation of inverted V braced steel frames with or without P-${\Delta}$ effects modeling was conducted by following the FEMA 273 NSP (Nonlinear Static Procedure). The problem in estimating dynamic P-${\Delta}$ modification factor (C3) in FEMA 273 was discussed. The results of this study indicated that the P-${\Delta}$ effects should be included in the seismic performance evaluation of centrally braced steel frames. This study also showed that the inverted V braced frames, retrofitted by applying the tie bars to redistribute the inelastic demand over the height of the building, exhibit significantly improved seismic performance.

Improvement of Seismic Performance Evaluation Method of Gravity Type Concrete Dam Applying Maximum Credible Earthquake (MCE) (가능최대지진(MCE)을 적용한 중력식 콘크리트 댐 내진성능평가 방안 개선)

  • Oh, Jeong-Keun;Jeong, Yeong-Seok;Kwon, Min-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.74-85
    • /
    • 2022
  • The purpose of this paper is to review the applicability of the current standards for the evaluation method of input variables and performance level in seismic performance evaluation by dynamic plastic analysis of the concrete gravity-type dam to which MCE is applied, and to suggest improvements. To this end, a domestic concrete gravity-type dam was selected as a target facility, dynamic plasticity analysis was performed under various conditions, and applicability to input variables such as concrete tensile strength and breaking energy, was reviewed. By analyzing the effect of cracks at the bottom of the gravity dam on the stability of the activity, an improvement plan for the performance level evaluation method required to secure the water storage function was derived. If the proposed improvement plan is applied, it will have the effect of deriving more reasonable evaluation results than the current seismic performance evaluation method to which MCE is applied.

Seismic Performance Evaluation of Sprinkler Facilities throughout Shaking Table Test (진동대 실험을 통한 스프링클러 설비의 내진성능 평가)

  • Nam, Min-Jun;Park, Seung-Hee;Kim, Dong-Jun;Yoon, Jong-Ku;Seo, Choon-Gyo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.54-57
    • /
    • 2012
  • 지진에 의한 2차 피해 중 화재로 인한 피해가 거의 대부분이다. 따라서, 소화설비의 내진설계는 반드시 필요하며 소화능력을 유지해야 한다. 본 연구에서는 진동대 실험을 통하여 스프링클러 설비의 내진성능을 평가하였다. 스프링클러 설비의 내진성능을 평가하기 위하여 일반 설비와 내진처리가 된 설비를 동시에 시공하여 그 성능을 평가하였다. 또한, 시설물의 거동특성을 파악하기 위하여 시설별 변위응답, 가속도 응답, 가속도 응답스펙트럼을 통하여 시설물에 대한 내진성능을 평가하였다.

  • PDF