• Title/Summary/Keyword: 지진레벨

Search Result 22, Processing Time 0.025 seconds

Seismic Damage Index Proposal and Damage Assessment for Cable-Stayed Bridge (사장교의 내진 손상지수의 제안 및 손상도 평가)

  • Kim, Eung-Rok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.127-135
    • /
    • 2018
  • With the nation showing increasing concern for earthquakes, there have been several methods for the analysis of earthquakes and evaluation of damage. Nevertheless, there is no clear standard to assess the seismic damage to structures quantitatively. Accordingly, this study conducted seismic analysis of several forms of seismic waves and actual seismic load, targeting the cable stayed bridge, which is supported by a cable and proposes a method for evaluating the damage based on the results. The damage index was calculated based on the tilting of the pylon of the cable-stayed bridge and the characteristics of physical seismic damage was suggested with 4 levels, such as A, B, C, and D. In addition, it is not proper to simply judge that the seismic damage index is obtained as large or small at all times depending on the seismic analysis method. Although this study focused on the proposal seismic damage index and an evaluation of the damage targeting the cable stayed bridge, the result was applied to a structure with a similar maximum displacement response.

Analytical Investigation for Improved Design Models of Chevron Braced Frames (역V형 가새 골조의 개선된 디자인 모델을 위한 해석적 연구)

  • Yoo, Jung-Han
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.73-78
    • /
    • 2009
  • Steel Braced frames are a commonly-used seismic resisting system, and chevron steel braced frames are a frequently used type of steel braced frame. Recent research has indicated that the seismic performance of braced frames can be improved by designing the braced frame gusset plate connections in a manner that direct reflects seismic deformation demands, and by permitting yielding in the gusset plate at select performance levels. A parametric study using Finite Element (FE) models was conducted to examine the influence of the gusset plate and framing elements on the seismic performance of chevron braced frames, and to calibrate and develop improved design models. The impact of the frame details, including frame sizes, clearance requirements, gusset plate thickness and tapered plate, was explored. The results suggested that proper detailing of the connection can result in a significant improvement in the frame performance. The results also show that the gusset plate thickness has a significant impact on frame performance.

Shaking Table Test of a 1/10 Scale Isolated Fifteen-story Flat Plate Apartment Building (면진층을 가지는 1/10 축소된 15층 무량판 아파트건물의 진동대 실험)

  • Chun, Young-Soo
    • Land and Housing Review
    • /
    • v.2 no.3
    • /
    • pp.287-297
    • /
    • 2011
  • This paper presents the results of performance verification tests of the isolated flat plate apartment building with the laminated rubber bearings. The shaking table test is carried out in CABR(China Academy of Building Research) with two 1/10 scale isolation and non-isolation models under 4 excitation waves. The shaking table test is proceeding from x axis, y axis and x+y axis with different amplitude of acceleration values. The results show that, to non-isolated model, the natural vibration period is remarkably decreased and entered non-linear condition after moderate earthquake. Its accelerations become lager with increasing storey number and completely collapsed under large earthquake. The inter-storey shifts largely exceed the limit values of regulated displacement angles. But to isolated model, the natural vibration period of isolated modal is almost the same in all conditions and still in its elastic condition. The earthquake loading is greatly reduced and the accelerations of superstructure are greatly reduced. The inter-storey drifts are very small and can be neglected. The isolated model is in translational state and can be seen as a rigid whole. The displacements of isolation layer are in the allowable range. This experiment demonstrates that the seismic isolation is very effective to mitigate the influence of earthquake on structures and it is possible to increase the serviceability due to decrease the floor acceleration. facilities from their good states that is superior to non-isolated structure.

Influence of ductility of reinforcement on the plastic hinge formation (철근의 연성이 소성힌지 생성에 미치는 영향)

  • Park, Dae-Gyun;Cho, Jae-Yeol;Park, Sung-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.97-100
    • /
    • 2008
  • Subjected to seismic action causing large deformation of bridge columns, the plastic hinge region is commonly formed in the column end zone. The deformation capacity of a concrete column can be expressed by using plastic hinge length. The mechanical properties of high-strength reinforcing steel is different from that of normal-strength steel and the mechanical properties of steel will influence the plastic hinge formation. Therefore, in other to accurately predict the deformation of concrete column using high-strength steel, the plastic hinge length can be expressed as a function of the mechanical properties of steel such as the tensile to yield strength ratio and the strain at ultimate state. However, little research has been conducted into the effect of mechanical properties of steel on the plastic hinge length. It was difficult to measure the plastic hinge length from the test results. Therefore, the plastic hinge length of concrete columns was investigated from the curvature profile. A numerical approach was used to study the effect of various parameters on plastic hinge length. Based on the results of the numerical parametric study, a new expression for plastic hinge length was proposed.

  • PDF

Vibration Control of Steel-Frame Structures by a Linear Motor Damper (선형 모터 댐퍼를 이용한 철골 구조물의 진동제어)

  • 문석준;정태영;임채욱;정정교;박진일;김두훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.49-58
    • /
    • 2003
  • The linear motor has not only no backlash and less friction, resulting in very high accuracy, but also mechanical simplicity, higher reliability, and longer lifetime. In this study, a large-capacity hybrid mass damper using linear motor principle has been developed to suppress vibration of large structures. It is designated linear motor damper in this paper. The LMD has been designed to be able to move the auxiliary damper mass of 155kg up to $\pm$250mm stroke. A series of performance tests for LMD control system with $H_{winfty}$ robust controller have been carried out on the full-scale steel frame structure. Through the performance tests, it is confirmed that vibration response levels are reduced down 10dB for the first and second modes of the test structure.

Characteristics of Stress-strain Relationship of Concrete Confined by Lateral Reinforcement (횡철근에 의해 횡구속된 콘크리트의 응력-변형률 특성)

  • Jeong, Hyeok-Chang;Kim, Ick-Hyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.67-80
    • /
    • 2009
  • The basic concept of seismic design is to attain the ductility required in a design earthquake. This ductility can be obtained by providing sufficient lateral confinements to the plastic hinge regions of columns. The most cost-effective design might be derived by determining the proper amount of lateral confinement using a stress-strain relationship for confined concrete. Korean bridge design code requires the same amount of lateral confinement regardless of target ductility, but Japanese design code provides the stress-strain relationship of the confined concrete to determine the amount of lateral confinement accordingly. While design based on material characteristics tends to make the design process more involved, it makes it possible to achieve cost-effectiveness, which is also compatible with the concept of performance-based design. In this study, specimens with different numbers of lateral confinements have been tested to investigate the characteristics of the stress-strain relationship. Test results were evaluated, using several empirical equations to quantify the effects.

Seismic Behavior and Performance Evaluation of Uckling-restrained Braced Frames (BRBFs) using Superelastic Shape Memory Alloy (SMA) Bracing Systems (초탄성 형상기억합금을 활용한 좌굴방지 가새프레임 구조물의 지진거동 및 성능평가)

  • Hu, Jong Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.875-888
    • /
    • 2013
  • The researches have recently progressed toward the use of the superelastic shape memory alloys (SMAs) to develop new smart control systems that reduce permanent deformation occurring due to severe earthquake events and that automatically recover original configuration. The superelastic SMA materials are unique metallic alloys that can return to undeformed shape without additional heat treatments only after the removal of applied loads. Once the superelastic SMA materials are thus installed at the place where large deformations are likely to intensively occur, the structural system can make the best use of recentering capabilities. Therefore, this study is intended to propose new buckling-restrained braced frames (BRBFs) with superelastic SMA bracing systems. In order to verify the performance of such bracing systems, 6-story braced frame buildings were designed in accordance with the current design specifications and then nonlinear dynamic analyses were performed at 2D frame model by using seismic hazard ground motions. Based on the analysis results, BRBFs with innovative SMA bracing systems are compared to those with conventional steel bracing systems in terms of peak and residual inter-story drifts. Finally, the analysis results show that new SMA bracing systems are very effective to reduce the residual inter-story drifts.

Base Isolation of the 1/3 Scaled RC Building with the Laminated Rubber Bearings (적층고무형 면진 장치를 갖는 철근콘크리트 건물의 면진 특성)

  • Chang Kug-Kwan;Chun Young-Soo;Kim Dong-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.975-982
    • /
    • 2005
  • Scientific community agrees about the fact that base Isolation provides interesting solutions to minimize the seismic risk. Reliability of such a technique is nowadays proofed by a large number of applications like public buildings, nuclear plants, bridges, etc. This paper reports the results of performance verification tests of the base isolated RC building with the laminated rubber bearings which is manufactured by enterprise in Korea. The shaking table tests were performed using a three story model scaled to 1/3 of the prototype RC apartment building. Several major earthquake records were scaled to different peak ground accelerations and used as input base excitations. Especially in this study, effect of earthquake characteristics on response reduction and effect of the intensity of excitations are studied. Through the verification tests, the validity of the applied base isolaion device and the response reduction effect against earthquakes are confirmed.

Examination of Seismic Performance for Structure with Seismic Members made by High Strength Steel (고강도강 내진성능 향상부재를 적용한 건물 성능 비교)

  • Kim, Moonjeong;Ha, Tae Uk;Cho, Sukhee
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.3
    • /
    • pp.281-288
    • /
    • 2015
  • Seismic members like damper do not have any treatment of preventing story stiffness reduction after elastic yielding of stories causing story collapse. This paper suggests a method able to prevent story stiffness reduction using high-strength steel. This paper suggests these also : (1) High-strength steel stud column reinforcing story stiffness reduction until story drift 0.02rad can be designed in small area without adjusting layout. (2) Suggested seismic member installing at lowest level shows effects to preventing deformation concentration under huge seismic waves.

위성광학탑재체 궤도시험을 위한 진동차단장치

  • Lee, Sang-Hun;Jo, Hyeok-Jin;Seo, Hui-Jun;Mun, Gwi-Won;Choe, Seok-Won
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.46.4-47
    • /
    • 2009
  • 인공위성은 지상에서 설계 제작된 후에 발사체에 탑재되어 궤도에 진입되어 위성에 부여된 고유임무를 수행하게 된다. 위성체가 임무를 수행하는 우주공간은 고진공 환경과 태양 복사열에 의한 고온 환경 및 극저온이 반복되는 가혹한 환경으로 특징지어진다. 때때로 위성체는 이러한 가혹한 우주환경의 영향으로 인해 주요 부품의 기능장애가 초래되기도 하며 이는 결국 임무의 실패로 이어지도 한다. 따라서 고진공과 극저온 환경으로 일컬어지는 우주환경을 지상에서 모사하여 위성체의 안정성 및 신뢰성을 시험하기 위해서 열진공 시험장비를 이용한 열진공시험을 수행한다. 한국항공우주연구원에서는 인공위성의 탑재체인 광학카메라의 국산화 개발을 위하여 우주공간의 고진공과 극저온 상태를 모사할 수 있는 $\varphi4m\timesL10m$ 규모의 광학탑재체 전용 열진공챔버를 국산화 제작하였다. 관측 위성용 광학카메라는 초고정밀 장비로서, 이를 테스트하기 위한 광학탑재체용 진공챔버는 특히 진동환경에 매우 민감한 하여 10-7 grms 이하의 진동레벨을 허용하고 있다. 그러나 진공용기는 지진 및 외부 환경으로부터의 시스템외부진동과 진공펌프 및 기타 장비들로부터의 내부 진동환경에 항상 노출되어 있으며, 가진 주파수가 구조물 자체의 고유진동수와 일치될 경우 공진이 발생하여 시스템에 큰 영향을 미칠 수 있으므로, 외부 진동 및 챔버 자체 진동이 광학계에 전달되지 않도록 진동차단장치가 필요하다. 이 논문에서는 광학탑재체 궤도환경시험용 챔버에 대한 진동차단장치의 개발 및 활용 예를 논의하고자 한다.

  • PDF