• Title/Summary/Keyword: 지점변위

Search Result 211, Processing Time 0.022 seconds

Cyclic Local Buckling Behavior of Steel Members with Web Opening (유공 강구조 부재의 반복 국부좌굴거동)

  • Lee, EunTaik;Ko, KaYeon;Kang, JaeHoon;Chang, KyoungHo
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.4 s.65
    • /
    • pp.423-433
    • /
    • 2003
  • Many study have been performed to describe the elastic and inelastic behavior of H-shaped beams with web openings that generally concentrated on the monotonic loading condition and concentric web opening. The findings of the studies led Darwin to propose formulas for the design of beams with web openings considering local buckling. While the formulas are simple and useful in real situation, more studies arc needed on their cyclic loading condition. In this experimental study, 12 H-shaped beams with web openings under cyclic loading condition were investigated. The dimension criteria based on the formulas proposed by Darwin were examined. The suitability of existing design formulas and the effects of plastic hinges on beams with web openings and of local buckling around web openings on the beam strength under cyclic loading were also studied. This was done by observing their behavior with various dimensional openings, eccentric per cent, and stiffeners.

Intercomparison of uncertainty to bias correction methods and GCM selection in precipitation projections (강수량예측에서 편이보정방법과 GCM 선택에 대한 불확실성 비교)

  • Song, Young Hoon;Chung, Eun-Sung
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.4
    • /
    • pp.249-258
    • /
    • 2020
  • Many climate studies have used the general circulation models (GCMs) for climate change, which can be currently available more than sixty GCMs as part of the Assessment Report (AR5). There are several types of uncertainty in climate studies using GCMs. Various studies are currently being conducted to reduce the uncertainty associated with GCMs, and the bias correction method used to reduce the difference between the simulated and the observed rainfall. Therefore, this study mainly considered climate change scenarios from nine GCMs, and then quantile mapping methods were applied to correct biases in climate change scenarios for each station during the historical period (1970-2005). Moreover, the monthly rainfall for the future period (2011-2100) is obtained from the RCP 4.5 scenario. Based on the bias-corrected rainfall, the standard deviation and the inter-quartile range (IQR) from the first to third quartiles were estimated. For 2071-2100, the uncertainty for the selection of GCMs is larger than that for the selection of bias correction methods and vice versa for 2011-2040. Therefore, this study showed that the selection of GCMs and the bias correction methods can affect the result for the future climate projection.

A Numerical Study on the Strain Based Monitoring Method for Lateral Structural Response of Buildings using FBG Sensors (FBG를 이용한 변형률 기반 건물의 횡방향 구조반응 모니터링 기법에 관한 해석적 연구)

  • Choi, Se Woon;Park, Keunhyoung;Kim, Yousok;Park, Hyo Seon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.4
    • /
    • pp.263-269
    • /
    • 2013
  • In this study, the strain based monitoring method to evaluate the lateral structural response of buildings is presented and an applicability of the proposed method is confirmed through the numerical study. It is assumed that the fiber Bragg grating(FBG) strain sensor is employed to measure the strain response of members due to the excellent properties such as multiplexing, and higher sampling frequency. These properties of FBG sensors is proper for buildings the a lot of sensors are required to monitor the reponses of those. FBG sensors measure the strain response of vertical members and are employed to calculate the curvatures of members using the measured strain responses. Then the lateral displacement, and lateral acceleration is evaluated based on the curvatures of vertical members. Additionally, these dynamic responses of buildings are used to evaluate the dynamic properties of buildings such as the natural frequencies and mode shapes using the frequency domain decomposition(FDD) method. Through the application of nine-story steel moment frame example structure, it is confirmed that the proposed method is appropriate to evaluate the lateral structural responses and dynamic properties of buildings.

Coupled Finite Element Analysis of Partially Saturated Soil Slope Stability (유한요소 연계해석을 이용한 불포화 토사사면 안전성 평가)

  • Kim, Jae-Hong;Lim, Jae-Seong;Park, Seong-Wan
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.4
    • /
    • pp.35-45
    • /
    • 2014
  • Limit equilibrium methods of slope stability analysis have been widely adopted mainly due to their simplicity and applicability. However, the conventional methods may not give reliable and convincing results for various geological conditions such as nonhomogeneous and anisotropic soils. Also, they do not take into account soil slope history nor the initial state of stress, for example excavation or fill placement. In contrast to the limit equilibrium analysis, the analysis of deformation and stress distribution by finite element method can deal with the complex loading sequence and the growth of inelastic zone with time. This paper proposes a technique to determine the critical slip surface as well as to calculate the factor of safety for shallow failure on partially saturated soil slope. Based on the effective stress field in finite element analysis, all stresses are estimated at each Gaussian point of elements. The search strategy for a noncircular critical slip surface along weak points is appropriate for rainfall-induced shallow slope failure. The change of unit weight by seepage force has an effect on the horizontal and vertical displacements on the soil slope. The Drucker-Prager failure criterion was adopted for stress-strain relation to calculate coupling hydraulic and mechanical behavior of the partially saturated soil slope.

A Study on Efficiency Improvement of X-Band Power Amplifier Using Harmonic Control Circuit (고조파 제어 회로를 이용한 X-대역 전력 증폭기의 효율 개선에 관한 연구)

  • Kim, Hyoung-Jong;Choi, Jin-Joo;Kim, Dong-Yoon;Na, Hyung-Gi
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.9
    • /
    • pp.987-994
    • /
    • 2010
  • In this paper, a simple and effective active load-pull method is proposed, and the method to improve the efficiency of X-band power amplifier using harmonic control circuit is presented. The proposed active load-pull system mainly consists of directional coupler, phase shifter, short circuit, and power amplifier, and allows a user to access reflection coefficients near the edge of the Smith chart($\Gamma$=1) easily. The device used in this paper is Mitsubishi's GaAs FET MGF1801, and the operating frequency of the power amplifier is 9 GHz, The amplifier had output power of 21.65 dBm and drain efficiency of 24.9 % at class-A, and had output power of 21.46 dBm and drain efficiency of 53.3 % at class-AB. Harmonic control circuit is designed only second and third harmonic components because of the bandwidth limitation of the microwave components. The drain efficiency is improved as much as 6.4 % compared with class-AB power amplifier.

Application of Image Processing Method to Evaluate Ultimate Strain of Rebar (철근의 한계상태변형률 평가를 위한 이미지 프로세싱의 적용)

  • Kim, Seong-Do;Jung, Chi-Young;Woo, Tae-Ryeon;Cheung, Jin-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.3
    • /
    • pp.111-121
    • /
    • 2016
  • In this study, measurements were conducted by image processing to do an in-depth evaluation of strain of rebar in a uniaxial tension test. The distribution of strain and the necking region were evaluated. The image processing is used to analyze the color information of a colored image, so that the parts consistent with desired targets can be distinguished from the other parts. After this process, the image was converted to a binary one. Centroids of each target region are obtained in the binary images. After repeating such process on the images from starting point to the finishing point of the test, elongation between targets is calculated based on the centroid of each target. The tensile test were conducted on grade 60 #7(D22) and #9(D29) rebars fabricated in accordance with ASTM A615 standards. Strain results from image processing were compared to the results from a conventional strain gauge, in order to see the validity of the image processing. With the image processing, the measuring was possible in not only the initial elastic region but also the necking region of more than 0.5(50%) strain. The image processing can remove the measuring limits as long as the targets can be video recorded. It also can measure strain at various spots because the targets can easily be attached and detached. Thus it is concluded that the image processing helps overcome limits in strain measuring and will be used in various ways.

A Study on Static Behavior of 60 m span Half-Decked PSC Girder (Half-Deck을 포함한 60 m 경간 PS 콘크리트거더의 정적 거동 연구)

  • Kim, Tae Min;Park, Jong Heon;Kim, Moon Kyum;Lim, Yun Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2A
    • /
    • pp.65-73
    • /
    • 2012
  • In this study, we tested structural performance of Half-Decked PSC girder which was developed for applying to long span bridge. We operated 4 point bending test with 60 m span full scale girder designed as simple bridge with hinge-roller boundary condition. Actuators were set on the both sides of girder, 5.5 m away from the center, and 4 stages of cyclic loading was applied at rate of 1 kN/sec. Through stages 1 to 4, loading and unloading 1,000 kN, 1,200 kN, 1,500 kN, and 2,000 kN were repeated and displacement, strain of concrete and steel, crack of girder were checked. From these results, the strength of girder was assessed and resilience and ductility were observed after removing the load. Since initial flexural crack occurred in the vicinity of 1,400 kN, non-linearity of load-displacement curve appeared and definite residual strain was measured at that point. The test result showed that initial cracking load was over twice the DB-24 load which means the developed girder had sufficient strength. To verify the experimental results, we numerically analyze the test and confirmed that the data were similar with results from the test above. Half-Decked PSC type of 60 m-girder developed in this study showed its adequate structural capacity through static loading test, which proved that possibility of applying the girder to actual bridges practically.

Ground Subsidence Estimation in a Coastal Reclaimed Land Using JERS-1 L-band SAR Interferometry (JERS-1 L-band SAR Interferometry 를 이용한 연안매립지 지반침하 관측)

  • 김상완;이창욱;원중선
    • Economic and Environmental Geology
    • /
    • v.35 no.5
    • /
    • pp.465-478
    • /
    • 2002
  • We measured subsidences occurred in a coastal reclaimed land, Noksan industrial complex, from May 2, 1996 to February 21, 1998, using 5 interferograms of JERS-1 L-band SAR. SAR with a spatial resolution of about 16 m can detect the two-dimensional distribution of subsidence that is difficult to be estimated from in situ measurements. Accuracy of the subsidences estimated by 2-pass DInSAR was evaluated using the measurements of Magnetic Probe Extensometer (accuracy of :${\pm}$1 mm) installed at 42 stations. DInSAR measurements were well correlated with the field measurements showing an average correlation coefficient of 0.77. The correlation coefficient was further improved to be 0.87 (with RMSE of 1.44 cm) when only highly coherenced (>0.5) pixels were used. The slope of regression line was 1.04, very close to the unit value. In short, DInSAR measurements have a good linear relation with field measurements so that we can effectively detect a subsidence in the coastal reclaimed area especially using pixels of high coherence (>0.5). The maximum accumulated subsidence was about 60 cm in the study area, while the subsidence in the northern and south western areas were less than 20 cm. The resuts show that DInSAR is extremely useful for geotechnical applications as well as observation of natural deformation.

Application of SP Survey and Numerical Modeling to the Leakage Problem of Irrigation facilities (수리시설물 누수탐지에 대한 자연전위법 적용 및 수치 해석)

  • Song Sung-Ho;Kwon Byung-Doo;Yang Jun-Mo;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.257-261
    • /
    • 2002
  • We have carried out integrated research including field survey and numerical modeling to appraise the applicability of SP method to the leakage problems of irrigation facilities. The leakage pattern of the dike studied here can be classified into the three categories: leakage through the abutment, leakage by piping through dike, and leakage due to the composite effects of landslide and distortion of the dike structure. for the numerical modeling to interpret quantitatively SP survey results acquired at dike, we have modified the computer code proposed by Sill (1983) to apply to the leakage problems. The numerical studies match the characteristic patterns of SP anomalies according to the leakage types and appear to be very useful to interpret the leakage zone and path. The SP monitoring results were also well coincided with tidal variations observed at every embankment so we found the SP method is quite effective not only to detect the leakage zone but also to determine the leakage trend. The numerical modeling results also reproduced the SP anomalies due to seawater leakage in the embankment.

Experimental study on the Flexural Capacity of U-shape Composite Beam (U-형 복합보의 휨 성능에 관한 실험적 연구)

  • Ha, Sang-Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.143-149
    • /
    • 2019
  • In this study, a U-shape composite beam was developed to be effectively used for a steel parking lot which is 8m or lower in height. When the U-shape composite beam was applied to a steel parking lot, essential considerations were story-height and long-span. In addition, due to the mixed structural system with reinforced concrete and steel material, the U-shape composite beam needed to have a structural integrity and reliable performance over demand capacity. The main objective of this study was to investigate the performance of the structure consisting of the reinforced concrete (RC) slab and U-shape beam. A U-shape composite beam generally used at a parking lot served as a control specimen. Four specimens were tested under four-point bending. To calculate theoretical values, strain gauges were attached to rebar, steel plate, and concrete surface in the middle of the specimens. As the results, initial yielding strength of the control specimen occurred at the bottom of the U-shaped steel. After yielding, the specimen reached the maximum strength and the RC slab concrete was finally failed by concrete crush due to compressive stress. The structural performance such as flexural strength and ductility of the specimen with the increased beam depth was significantly improved in comparison with the control specimen. Furthermore, the design of the U-shape composite beam with the consideration of flexural strength and ductility was effective since the structural performance by a negative loading was relatively decreased but the ductile behavior was evidently improved.