• 제목/요약/키워드: 지열이용 시스템

Search Result 191, Processing Time 0.025 seconds

An Automatic Back-Light Brightness Control System of Mobile Display Using Built-In Photo Sensor (내장형 광센서를 이용한 모바일 디스플레이의 자동 광원 밝기 조정 시스템)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.713-716
    • /
    • 2008
  • This paper presents an automatic back-light brightness control system for mobile displays. One of the most important factors in mobile display is the power consumption due to the limited and movable power source. More than 80% of power of the LCD display is consumed by LED bark-light unit (BLU). The target brightness also becomes higher because of its moving picture and high resolution image, so there are some side effects for not only excessive power consumption but also ergonomic inconvenience in dark environment. To prevent this discomfort and reduce power consumption, this paper proposes automatic brightness control (ABC) technique in mobile displays. Developed system contains TFT-LCD panel with built-in photo sensor, driver IC capable of controlling photo sensor, and BLU. Since the photo sensor array built in panel detects automatically outdoor ambient light intensity, the power of BLU in dark environment is reduced. Developed ABC system showed reduced power consumption of 50% in dark environment. We believe that the proposed system is very useful to control power of mobile TFT-LCD.

  • PDF

Development and Application of the Slope Management Program in Urban Area (대도시 사면관리프로그램 개발 및 적용)

  • Kim, Kyeong-Su;Chae, Byung-Gon;Cho, Yong-Chan;Lee, Choon-Oh;Song, Young-Suk
    • The Journal of Engineering Geology
    • /
    • v.17 no.1 s.50
    • /
    • pp.15-25
    • /
    • 2007
  • In general, the life and asset casualties that occur due to landslide or slope failure in urban areas are larger than that in rural areas. In order to reduce the casualties, a slope management program is necessary to categorize slopes based on properties and to manage them systematically. The slope management system is the establishment of the data base for the geological and geotechnical factor according to slope stability, and the utilization of the data base to manage slopes. The suitable system must develop to slopes in urban area through the survey, analysis and evaluation process. Based on the above necessity, the slope management program which is applicable to slope management in an urban area has been developed at Hwangryung Mt. in Busan as a target area. The developed slope management program has various functions such as slope ID number of each slope or sub-region of a mountain, making a slope data sheet, analysis and grouping of slope stability, and establishment of a data base. The slope management program is constructed by use of GIS, and the survey, test and analysis data according to all slopes can be input and edited into the program. The program can also be utilized practically by end users due to the convenient input, edition printing, management and operation of slope data. Therefore, the slope management system has been established on the application of the developed program in Busan which is located in slope area. As the system is widely applied to other cities, the slope in urban area can be managed systematically and the slope hazards can be minimized.

Development of Automatic Fault Detection System for Chip-On-Film (칩 온 필름을 위한 자동 결함 검출 시스템 개발)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.2
    • /
    • pp.313-318
    • /
    • 2012
  • This paper presents an automatic system to detect variety of faults from fine pitch COF(chip-on-film) which is less than $30{\mu}m$. Developed system contains circuits and technique to detect fast various faults such as hard open, hard short, soft open and soft short from fine pattern. Basic principle for fault detection is to monitor fine differential voltage from pattern resistance differences between fault-free and faulty cases. The technique uses also radio frequency resonator arrays for easy detection to amplify fine differential voltage. We anticipate that proposed system is to be an alternative for conventional COF test systems since it can fast and accurately detect variety of faults from fine pattern COF test process.

Development of Image Quality Register Optimization System for Mobile TFT-LCD Driver IC (모바일 TFT-LCD 구동 집적회로를 위한 화질 레지스터 최적화시스템 개발)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.592-595
    • /
    • 2008
  • This paper presents development of automatic image quality register optimization system using mobile TFT-LCD (Thin Film Transistor-Liquid Crystal Display) driver IC and embedded software. It optimizes automatically gamma adjustment and voltage setting registers in mobile TFT-LCD driver IC to improve gamma correction error, adjusting time, flicker noise and contrast ratio. Developed algorithms and embedded software are generally applicable for most of the TFT-LCD modules. The proposed optimization system contains module-under-test (MUT, TFT-LCD module), control program, multimedia display tester for measuring luminance, flicker noise and contrast ratio, and control board for interface between PC and TFT-LCD module. The control board is designed with DSP and FPGA, and it supports various interfaces such as RGB and CPU.

  • PDF

A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring (온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구)

  • Kim, Jung-Yul;Song, Yoon-Ho;Kim, Yoo-Sung
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.4
    • /
    • pp.15-24
    • /
    • 2007
  • Two kinds of temperature monitoring technology have been introduced in this study, which can measure coincidently temperatures at many points along a single length of cable. One is to use a thermal sensor cable comprizing of addressable thermal sensors. The other is to use an optic fiber sensor with Distributed Temperature Sensing (DTS) system. The differences between two technologies can be summarized as follows: A thermal sensor cable has a concept of "point sensing" that can measure temperature only at a predefined position. The accuracy and resolution of temperature measurement are up to the capability of the individual thermal sensor. On the other hand, an optic fiber sensor has a concept of "distributed sensing" because temperature is measured practically at all points along the fiber optic cable by analysing the intensity of Raman back-scattering when a laser pulse travels along the fiber. Thus, the temperature resolution depends on the measuring distance, measuring time and spatial resolution. The purpose of this study is to investigate the applicability of two different temperature monitoring techniques in technical and economical sense. To this end, diverse experiments with two techniques were performed and two techniques are applied under the same condition. Considering the results, the thermal sensor cable will be well applicable to the assessment of groundwater flow, geothermal distribution and grouting efficiency within about loom distance, and the optic fiber sensor will be suitable for long distance such as pipe line inspection, tunnel fire detection and power line monitoring etc.

Development of a New Automatic Image Quality Optimization System for Mobile TFT-LCD Applications (모바일 TFT-LCD 응용을 위한 새로운 형태의 자동화질 최적화 시스템 개발)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.1
    • /
    • pp.17-28
    • /
    • 2010
  • This paper presents a new automatic TFT-LCD image quality optimization system using DSP for the first time. Since conventional manual method depends on experiences of LCD module developers, it is highly labor-intensive and requires several correction steps providing large gamma correction error. The proposed system optimizes automatically gamma adjustment and power setting registers in mobile TFT-LCD driver IC to reduce gamma correction error, adjusting time, and flicker. It contains module-under-test (MUT, TFT-LCD module), PC installed with program, multimedia display tester for measuring luminance and flicker, and control board for interface between PC and TFT-LCD module. We have developed a new algorithm using 6-point programmable matching technique with reference gamma curve and applying automatic power setting sequence. Developed algorithm and program are generally applicable for most of the TFT-LCD modules. It is realized to calibrate gamma values of 1.8, 2.0, 2.2 and 3.0, and reduce flicker level. The control board is designed with DSP and FPGA, and it supports various interfaces such as RGB and CPU. Developed automatic image quality optimization system showed significantly reduced gamma adjusting time, reduced flicker, and much less average gamma error than conventional manual method. We believe that the proposed system is very useful to provide high-quality TFT-LCD and to improve developing process using optimized gamma-curve setting and automatic power setting.

A Study on the Physical Characteristics of Grout Material for Backfilling Ground Heat Exchanger (지중 열교환기용 뒤채움재의 물리적 특성 연구)

  • Choi, Hang-Seok;Lee, Chul-Ho;Choi, Hyo-Pum;Woo, Sang-Baik
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.1
    • /
    • pp.37-49
    • /
    • 2008
  • A geothermal heat pump system is a preferable alternative energy system in Korea because it uses the heat energy of the earth, which is environmentally friendly and inexhaustible. In order to characterize the thermal conductivity and viscosity of grout materials used for backfilling ground heat exchangers, nine bentonite grouts, one marine clay from Boryung, and cement grouts adapted in the United State have been considered in this study. The bentonite grouts indicate that the thermal conductivity and viscosity increase with the content of bentonite or filler (silica sand). In addition, material segregation can be observed when the viscosity of grout is relatively low. The marine clay turns out to be unsuitable for backfilling the ground heat exchanger due to its insufficient swelling potential. The saturated cement grouts appear to possess much higher thermal conductivity than the saturated bentonite grouts, and the reduction of thermal conductivity in the cement grouts after drying specimens is less than that in the case of the bentonite grouts. Maintaining the moisture content of grouts is a crucial factor in enhancing the efficiency of ground heat exchangers.

Achieving Carbon Neutrality: Technology Innovations and Research Needs in the Division of Groundwater and Soil (탄소중립 달성을 위한 지하수토양분야 혁신기술 및 선도연구 소개)

  • Jongbok Choi;Younggyu Son;Young-Soo Han;Man Jae Kwon;Seunghak Lee;Kitae Baek;Yongseok Hong
    • Journal of Soil and Groundwater Environment
    • /
    • v.28 no.spc
    • /
    • pp.40-54
    • /
    • 2023
  • 산업혁명 이후 화석연료의 광범위한 사용, 삼림 벌채, 토지사용의 변화 등과 같은 인위적 활동은 대기 중 온실가스(GHGs, greenhouse gases) 농도를 지속적으로 증가시켜 지구의 기후위기를 유발하였다. 우리나라의 경우 최근 30년 사이 평균 온도가 1.4℃ 상승하였으며, 국제사회의 일원으로 책임을 다하기 위해 2016년 11월 3일 파리협정을 비준하였다. 이에 파리협정의 목표인 산업화 이전 대비 지구 평균온도 상승을 2℃ 아래, 가능한 1.5℃ 아래로 억제하기 위해 2050년까지 CO2 순배출량을 0으로 만들어야 하며, 이를 위해 다양한 정책 마련과 함께 경제 및 사회 전반에 걸쳐 많은 노력이 경주되고 있는 실정이다. 탄소중립을 달성하기 위해서는 첫 번째로 GHGs 배출을 줄이고, 두번째로 대기에서 CO2 포집을 촉진하기 위해 현재 가동되는 다양한 산업분야의 생산 시스템을 개혁하는 것이 가장 중요한 과제로 고려되고 있다. 그동안 지하수토양 관련 연구분야에서는 지속가능성(sustainability), 복원성(resilience), 녹색성장(green growth) 등과 같은 사회적 요구에 부응하여, 녹색정화(green remediation), 자연 저감(natural attenuation), 탄소포집저장(carbon capture and sequestration), 지열발전등의 기술이 초기단계로 개발이 되고 연구가 되어 왔다. 이러한 기존 연구들은 탄소중립2050의 달성을 위해 고도화되어야하며, 추가적으로 자연 및 인위기원 탄소배출 연구, 토양의 역할을 고려한 저탄소 토지이용 기술, 광물탄산화 등의 연구 및 기술개발이 필요하다고 판단된다. 본 논문에서는 탄소중립2050의 간단한 내용과 함께, 이를 달성하기 위한 지하수토양 분야의 혁신기술 및 선도연구를 소개하였다.

Hydraulic feasibility study on the open-loop geothermal system using a pairing technology (복수정 페어링 기술을 이용한 개방형 지열 시스템의 수리적 타당성 검토)

  • Bae, Sangmu;Kim, Hongkyo;Kim, Hyeon-woo;Nam, Yujin
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.119-124
    • /
    • 2017
  • Purpose: Groundwater heat pump (GWHP) system has high coefficient of performance than conventional air-source heat pump system and closed-loop type geothermal system. However, there is problem in long-term operation that groundwater raise at the diffusion well and reduced at the supply well. Therefore, it is necessary to accurately predict the groundwater flow, groundwater movement and control the groundwater level in the wells. In this research, in consideration of hydrogeological characteristic, groundwater level and groundwater movement were conducted analysis in order to develop the optimal design method of the two-well system using the pairing pipe. Method: For the optimum design of the two-well system, this research focused on the design method of the pairing pipe in the simulation model. Especially, in order to control the groundwater level in wells, pairing pipe between the supply well and diffusion well was developed and the groundwater level during the system operation was analyzed by the numerical simulation. Result: As the result of simulation, the groundwater level increased to -2.65m even in the condition of low hydraulic conductivity and high pumping flow rate. Consequently, it was found that the developed system can be operated stably.

Thermal Conductivity Measurement of Rock Cores from Ulleung Island Using PEDB System at Room Temperature (상온 환경에서 PEDB를 이용한 울릉도 시추코어의 열전도도 예비 측정)

  • Lee, Sang Kyu;Lee, Tae Jong
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.3
    • /
    • pp.121-130
    • /
    • 2016
  • Several factors are discussed that should be considered in measuring thermal conductivity of rock cores with a PEDB (potable electronic divided bar) system, which is relatively accurate and easy to operate, and can measure the thermal conductivity of rock cores for various diameters. Then the system is applied to measure thermal conductivity of 70 rock cores from Ulleung Island. Air temperature affects most on the thermal conductivity measurements, so that it is very important to minimize the temperature change during the measurement. Other factors such as the temperature of heat source, averaging time window on the thermal conductivity measurements do not affect much compared to air temperature. Slightly higher thermal conductivity is measured when using the thermal contact paste between the sample and heat source or heat sink. Especially, rock cores with irregular surface showed bigger difference. Repeatability showed less than ${\pm}0.3%$ for standard samples and less than ${\pm}4%$ for rock samples, respectively, when the room temperature changes within $1^{\circ}C$ during the measurements. Thermal conductivity of the rock cores from Ulleung Island roughly increases as depth increases but does not show any dependency on the rock types.