• Title/Summary/Keyword: 지열이용 시스템

Search Result 191, Processing Time 0.022 seconds

The feasibility study for the building integrated geothermal system using the horizontal heat exchanger (수평형 지중열교환기를 이용한 건물일체형 지열시스템의 도입타당성 분석)

  • Chae, Ho-Byung;Nam, Yujin;Yoon, Sung-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.1
    • /
    • pp.81-87
    • /
    • 2015
  • Recently, in order to prevent increasing energy usages in the international community, many countries have attempted to develop the innovative renewable energy systems. Among the renewable energy systems, Ground source heat pump(GSHP) system which supply the heating, cooling and hot water in the building has been attracted by its stability of heat production and high efficiency. However, the initial drilling costs become very expensive and the construction period takes longer the other systems, because GSHP system needs more than 100 m depth drilling. In this study, in order to reduce initial costs of the GSHP, the building integrated geothermal system using the horizontal heat exchanger was developed. The heating and cooling load in the standard housing model was calculated by a simulation and the system design capacity in the high-rise apartment was decided by the total load. Based on the system design capacity, the high-rise apartments were applied to a BIGS and vertical GSHP system and there are analyzed about initial costs. In the result, the initial cost of BIGS could reduce 24% of the initial cost of the vertical GSHP system.

Study on the Performance Prediction Simulation of the Heat Pump System using Solar and Geothermal Heat Source (태양열 및 지열 이용 히트펌프 시스템의 성능예측 시뮬레이션에 관한 연구)

  • Nam, Yu-Jin;Gao, Xin-Yan
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.75-81
    • /
    • 2014
  • Recently, the use of renewable energy has been attracted due to the interest in energy-saving and the reduction of CO2 emission. In order to reduce the energy consumption of the cooling and the heating in the field of the architectural engineering, heat pump systems using renewable energy have been developed and used in various applications. In many researches, integrated heat pump systems are suggested which use solar and geothermal heat as the heat source for cooling and heating. However, it is still difficult to predict the performance of the systems, because the characteristic of heat exchange in each system is complicated and various. In this system, the performance prediction simulation of the heat pump was developed using a dynamic simulation model. This paper describes the summary of the suggested systems and the result of the simulation. The average temperature of the heat source, heating loads and COP were calculated with the cases of different local conditions, different system composition and different operation time by TRNSYS 17.

Study on Fresh Air Load Reduction System by Using Geothermal Energy - Reducing Effect of a Fresh Air Load by Combining with Air-heated Solar Collector - (지열을 이용한 공조외기부하저감 시스템에 관한 연구 - 공기식 집열기와의 병용에 의한 공조외기부하저감 효과 -)

  • Son Won-Tug;Lee Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1218-1226
    • /
    • 2004
  • This paper presents thermal behaviors and performances of a fresh air load reduction system by using earth tube system combined with air-heated solar collector. The earth tube system reduces a fresh air load by heat exchange with soil throughout the year. In the previous experimental research, it was clarified that the earth tube system was very useful as a fresh air load reduction system. However, since outlet temperature of the fresh air which was heated by earth tube system was below 15$^{\circ}C$ in winter, it is not suitable to introduce the fresh air into the place of residence directly. Therefore, a simulation model using the simple heat diffusion equation was used to examine a rising effect of outlet air temperature in winter by combining with air-heated solar collector. An improvement of annual performance by control of operation is also quantitatively examined. In conclusion, it is confirmed that its performance is improved by control of operation throughout the year and outlet air temperature rose by combining with air-heated solar collector.

Evaluation of Incident Detection Algorithms focused on APID, DES, DELOS and McMaster (돌발상황 검지알고리즘의 실증적 평가 (APID, DES, DELOS, McMaster를 중심으로))

  • Nam, Doo-Hee;Baek, Seung-Kirl;Kim, Sang-Gu
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.7 s.78
    • /
    • pp.119-129
    • /
    • 2004
  • This paper is designed to report the results of development and validation procedures in relation to the Freeway Incident Management System (FIMS) prototype development as part of Intelligent Transportation Systems Research and Development program. The central core of the FIMS is an integration of the component parts and the modular, but the integrated system for freeway management. The whole approach has been component-orientated, with a secondary emphasis being placed on the traffic characteristics at the sites. The first action taken during the development process was the selection of the required data for each components within the existing infrastructure of Korean freeway system. After through review and analysis of vehicle detection data, the pilot site led to the utilization of different technologies in relation to the specific needs and character of the implementation. This meant that the existing system was tested in a different configuration at different sections of freeway, thereby increasing the validity and scope of the overall findings. The incident detection module has been performed according to predefined system validation specifications. The system validation specifications have identified two component data collection and analysis patterns which were outlined in the validation specifications; the on-line and off-line testing procedural frameworks. The off-line testing was achieved using asynchronous analysis, commonly in conjunction with simulation of device input data to take full advantage of the opportunity to test and calibrate the incident detection algorithms focused on APID, DES, DELOS and McMaster. The simulation was done with the use of synchronous analysis, thereby providing a means for testing the incident detection module.

신성장동력인 신재생에너지 '선점'경쟁 가열

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • no.11 s.220
    • /
    • pp.29-37
    • /
    • 2008
  • 최근들어 국제 유가가 급등하고 지구 온난화 등 환경문제가 부각되면서 기존의 에너지를 대체하는 대안으로 신재생 에너지가 전 세계적으로 뜨거운 이슈로 떠오르고 있다. 더구나 온실가스 감축 등 본격적인 환경경제 시대가 도래하면서 환경친화적이고 고갈 염려가 없는 신재생에너지가 효과적인 대안으로 주목받고 있다. 또한 고유가 및 기술개발 가속화도 신재성에너지 시장 확대를 부채질하고 있어 신재생에너지에 대한 관심이 신성장동력으로 집중되고 있다. 이처럼 환경문제 해결에 대한 관심은 '선택'이 아닌 '필수'가 되었다. 우리나라도 국가 차원에서 이산화탄소 배출을 줄이기 위해 '저탄소 녹색성장' 정책을 마련하면서 신재생에너지 확대 보급을 위한 제도 및 대책이 새롭게 마련되고 있다. 건설산업은 대표적인 에너지 다소비업종에 속하기 때문에 이산화탄소 저감을 위해 에너지 저소비형 건축물 연구에 많은 투자를 하고 있으며, 신재생에너지를 이용한 생태토시 조성 등에 노력을 기울이고 있다. 특히 에너지를 다루는 기계설비는 이러한 신재생에너지와 밀접한 관련이 있기에 더욱 관심을 기울이고 있다. 태앙광을 비롯하며 지열, 풍력, 바이오 등 신재생에너지 개발은 물론 빗물이용 시스템 쓰레기 이송 설비와 같은 첨단과 환경이 조화를 이루는 아파트의 보급도 차츰 늘어나고 있는 추세다. '누구의 영역도 아닌' 곳이자 '누구의 영역도 될 수 있는' 신재생에너지가 설비건설업계에 확대, 보급되기 위해서는 설비건설업계의 관심이 집중되어야하며, 기술개발을 활발히 하여 선점경쟁에서 유리 한 고지를 접할 수 있을 것이다. 그렇다면 국내 신재생에너지의 개발 수준은 어디까지 왔을까? 이번 호는 그 현황을 집중 조명해 보고, 다음 호에는 풍력, 바이오에너지, 지열, 연료전자 수소 등을 하나씩 분석해 본다.

  • PDF

Moving Distance Measurement System using a Accelerometer Sensor (가속도 센서를 이용한 이동거리 측정 시스템)

  • Park, Seung-Hun;Lee, Jung-Hoon;Kim, Sung-Woo;Lim, Jae-Hwan;Ryu, Jee-Youl
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.6
    • /
    • pp.1300-1305
    • /
    • 2012
  • In this research, we propose a momentum measurement system using the accelerometer sensor, MCU, and Bluetooth to measure the exact momentum. The proposed system can figure out information for the real time travel distance. We performed various experiments, and analyzed the results using the proposed momentum measurement system. In the simulation experiments, we compared the reliability and accuracy for the existing momentum measurement systems from the analyzed results. The proposed system showed travel distance error of less than 8% as compared to the existing system with the error of approximately 13%. We expect that the proposed system apply to the commercial products.