• Title/Summary/Keyword: 지연선

Search Result 670, Processing Time 0.025 seconds

Design and Performance Analysis of CPSK Transmitter for RF-CBTC System in ISM Band (RF-CBTC 시스템을 위한 ISM 대역에서의 CPSK 송신기의 설계 및 성능분석)

  • Kim, Seong-Cheol
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.16 no.5
    • /
    • pp.152-161
    • /
    • 2017
  • The CBTC(Communication based Train Control) system employed on 2.4GHz ISM band adopt the IEEE802.11.x standard. Therefor communication time delay, distortion and data losses will be produced. To overcome these problems, CPSK(Continuous Phase shift keying) modulated DS/SS(Direct Sequence Spread Spectrum) transmitter with 908MHz carrier frequency is proposed. Through the eye diagram and scatter diagram the performance is analysed. And the phase noise characteristic of the local oscillator is measured about 60dBc/Hz, this means that the phase noise performance is very good compared to the signal. Reference frequency suppression of the 2nd local oscillator is 50dB below compared to the signal. Through the polarities of the complementary signal equally probable, the line spectrum of the output spectrum is eliminated. The nonlinear effects which introduce the spectral spreading or spectral regeneration is reduced remarkably.

A Study on the Effects of Gain Flatness of Feedforward Power Amplifier for IMT-2000 Band (IMT-2000용 피드포워드 전력 증폭기의 이득 평탄도의 영향에 관한 연구)

  • 정성찬;박천석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.7
    • /
    • pp.762-768
    • /
    • 2003
  • This paper reports the effects of gain flatness for linearity improvement of feedforward power amplifier fur IMT-2000 band. To investigate the operational characteristics for gain flatness of each amplifier, WCDMA 4FA input signal was used and measured 10 W output power. Especially, linearity improvement for variation of gain flatness of each amplifier was investigated that have an effect on linearity improvement such as delay line, phase, and amplitude imbalances. Variation of gain flatness of main amplifier is 40 MHz and of error amplifier is 40 MHz and 80 MHz bandwidth, respectively. Measured results, gain flatness of main amplifier is less than 1.5 dB and of error amplifier is less than 0.5 dB for more than 20 dB improvement at 5 MHz offset. In addition to that results, the characteristics of feedforward amplifier are drastically varied by gain flatness of error amplifier and it is shown that gain flatness of error amplifier is more important factor for linearity improvement.

A Case of Cardiofaciocutaneous Syndrome caused by BRAF gene mutation (BRAF 유전자의 돌연변이로 진단된 Cardiofaciocutaneous 증후군 1례)

  • Lee, Beom-Hee;Kim, Jae-Min;Lee, Jin-Joo;Kim, Gu-Hwan;Yoo, Han-Wook
    • Journal of Genetic Medicine
    • /
    • v.6 no.1
    • /
    • pp.87-90
    • /
    • 2009
  • Cardiofaciocutaneous (CFC) syndrome is characterized by dysmorphic features, cardiac anomalies, and cutaneous abnormalities. CFC syndrome belongs to the class of Noonan-related diseases. CFC syndrome can be clinically differentiated from other Noonan-related diseases by the distinct craniofacial features of sparse hair, a hypoplastic supraorbital ridge, exophthalmos and nystagmus, and skin manifestations such as ichthyosis and hyperkeratosis. However, phenotypes can overlap among Noonan-related syndromes, including CFC syndrome. Recently, several genes in the RAS-MAPK pathway have been identified as disease-causing genes for Noonan-related diseases. Here, we report on a Korean girl diagnosed with CFC syndrome caused by a V-raf murine sarcoma viral oncogene homolog B1 (BRAF) gene mutation, and we discuss the phenotype-genotype heterogeneities in Noonan syndrome and Noonan-related diseases.

  • PDF

Measurement of Skin Dose and Percentage Depth Does in Build-up Region Using a Fiber-optic Dosimeter (광섬유 방사선량계를 이용한 선량보강 영역에서의 심부선량 백분율과 피부 선량률 측정)

  • Cho, Dong-Hyun;Jang, Kyoung-Won;Yoo, Wook-Jae;Seo, Jeong-Ki;Heo, Ji-Yeon;Lee, Bong-Soo;Cho, Young-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.1
    • /
    • pp.16-20
    • /
    • 2010
  • In this study, we have fabricated a fiber-optic dosimeter using an organic scintillator and a plastic optical fiber. The dosimeter measure skin dose and percentage depth dose in a build-up region for an incident high energy photon beam. The scintillating light generated in the organic sensor probe embedded in a solid water phantom is guided by 30 m plastic optical fiber to a light-measuring device such as a PMT or an electrometer. In addition, using a fiber-optic dosimeter or a GAFCHROMIC EBT film, skin dose and percentage depth dose in the build-up region are measured and compared.

Effect of Antimicrobial Packaging System on the Freshness-preserving of Zucchinis (천연항균제 함유 포장소재처리에 의한 저장호박의 선도 유지효과)

  • 정순경;조성환
    • Food Science and Preservation
    • /
    • v.8 no.3
    • /
    • pp.274-278
    • /
    • 2001
  • The antimicrobial extracts of Rheum palmatum and Coptis chinensis root as well as grapefruit seed extract were applied to dipping treatment for keeping qualities of zucchinis, respectively, which were then packed in low density polyethylene films incorporated with 1% antimicrobial extracts and stored at 10$\^{C}$. Dipping and packaging in the antimicrobial agents suppressed the growth of putrefactive microorganisms and the decay ratio of zucchinis. In addition, the loss ratio of ascorbic acid content of zucchinis and their weight were decreased during the storage of zucchinis. Consequently, the combined method of dipping and packaging in antimicmbial agents tumid out to be superior to dipping treatment or film-packaging in the view point of decay ratio and the quality control of zucchinis.

  • PDF

RNSXI(real-name shooting X-ray of inspector) Settlement Realization applying PACS Database, In Digital Medical environment (PACS Database를 활용한 촬영실명제 정착화 실현)

  • Kang, Ji-Youn;Lee, Lae-Gon;Kang, Doo-Hee;Lee, Hwa-Sun;Hwang, Sun-Gwang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.5-9
    • /
    • 2007
  • As developing the medical treatment image portion with the change of these times, PACS, which is able to digitalize image portion data, has a lot of data-based image data. Applying this PACS, we would like to settle down RNSXI(real-name shooting X -ray of inspector) system. We interviewed with P ACS's operators of university hospitals which is using PACS in Seoul about the present conditions whether using of RNSXI or not. And we inquired the RNSXI equipments, applying PACS database, and Interface conditions undertook to do in our hospital. All university hospitals in Seoul are set up the P ACS system. But no hospital use the RNSXI. In our hospital, we can check inspector' name or initials who exposure x-ray with the PACS Viewer by looking over equipments(CR, DR, US, MG, MR, CT) and Interface of the DICOM Header data. However, some equipments like RF and Angio can not check inspector' name or initials. Under the Film/System environment, RNSXI system has been used frequently like that inspector's signature or initial added to a patient data. Though the digital medical treatment was developed, RNSXI system was declined. It is necessary to using RNSXI system in order to improving radiologists' rights, even if it is not under the application of the medical treatment image laws. If RNSXI system use, radiologists should specialize in their major and the Repeat rate should be reduced. In environment of PACS, RNSXI system can be used by linking both the equipments and the Interface with a production enterprise of P ACS. Therefore RNSXI system applying the P ACS datebase should settle down in our medical system for being provided lots of data.

  • PDF

A Correlation of Striation Spacing and DHC Velocity in Zr-2.5Nb Tubes (Zr-2.5Nb 압력관에서 Striation Spacing과 DHCV의 관계)

  • Choi Seung Jun;Ahn Sang Bok;Park Soon Sam;Kim Young Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.8 s.227
    • /
    • pp.1109-1115
    • /
    • 2004
  • The objective of this study is to elucidate what governs delayed hydride cracking (DHC) in Zr-2.5Nb tubes by correlating the striation spacings with DHCV(DHC Velocity). To this end, DHC tests were conducted on the compact tension specimens taken from the Zr-2.5Nb tubes at different temperatures ranging from 100 to $300^{\circ}C$ with a 3 to 6 data set at each test conditions. The compact tension specimens were electrolytically charged with 27 to 87 ppm H before DHC tests. After DHC tests, the striation spacings and DHCV were determined with the increasing the test temperature and yield strength. The striation spacing and DHCV increased as a function of yield $strength^2$ and the temperature. Since the plastic zone size ahead of the crack tip can be represented by ${\sim}(K_{IH}/{\sigma}_{Y})^2$, we conclude that the striation spacing is governed by the plastic zone size which in turn determines a gradient of hydrogen concentration at the crack tip. The relationship between the plastic zone size and the striation spacing was validated through a complimentary experiment using double cantilever beam specimens. Two main factors to govern DHCV of Zr-2.5Nb tubes are concluded to be hydrogen diffusion and a hydrogen concentration gradient at the crack tip that are controlled by temperature and yield strength, respectively. The activation energy of DHCV in the Zr-2.5Nb tubes is discussed on the basis of temperature dependency of hydrogen diffusion and the striation spacing.

A Study of GPS Precise Ephemeris Interpolation for Maritime Precise Positioning Applications (해양 정밀측위 활용을 위한 GPS 정밀위성궤도 보간 연구)

  • Cho, Deuk-Jae;Park, Sang-Hyun
    • Journal of Navigation and Port Research
    • /
    • v.33 no.10
    • /
    • pp.699-702
    • /
    • 2009
  • Currently many vessels determine an overhead obstruction by a rule of thumb based on their draft for maritime navigation. Therefore they doesn't have a good overhead obstruction clearance because vertical position of vessels varies on time by tidal. As a result, it is occurred maritime accidents that the mainmast of vessels is bumped against overhead facilities. And disaster by global warming and rising sea levels have increased casualties. So we feel keenly the necessity of warning system for not an earthquake but disaster wave such a tsunami. This paper analyzes a precise GPS ephemeris for maritime precise positioning to solve these problems. The precise GPS ephemeris provided by International GNSS service gives a difficulty to real-time application because of its sample interval. This paper proposes an effective interpolation method for real-time application, and it analyzes an accuracy of precise GPS ephemeris through an interpolation method.

Photopolymerization of Reactive Oligomers and Methacrylate/SBS Blends (반응성 올리고머 및 메타아크릴레이트/SBS 블렌드의 광중합)

  • 최영선;류봉기
    • Polymer(Korea)
    • /
    • v.27 no.5
    • /
    • pp.421-428
    • /
    • 2003
  • The kinetics of photoinitiated polymerization of reactive oligomer methacrylates and oligomer methacrylate/SBS blends have been studied to characterize the diffusion-controlled reaction using Fourier Transform Infrared Spectroscopy-Attenuated Total Reflectance (ATR-FTIR). The polymerization rates of reactive oligomer methacrylates and oligomer methacrylate/SBS blends were autocatalytic in nature at the initial stage and then a retardation of the reaction conversion occurred gradually as the polymer matrix became vitrified, and finally the reaction became diffusion controlled. Photopolymerization behavior of methacrylate/SBS blends was well predicted using the diffusion-controlled reaction model. N-Vinyl-2-pyrrolidinone (NVP) as a reactive solvent was used to incorporate SBS into methacrylate to form semi-IPN via photopolymerization. Due to the high reactivity of NVP, polymerization rate increased with the increase of NVP content. As the content of NVP-SBS in the blends increased up to 10 phr, the reaction conversion maintained almost constant. But above 20 phr of NVP-SBS in the blends, the reaction conversion gradually decreased since the increase of viscosity affected on the photopolymerization rate. The semi-IPN films of methacrylate/SBS blends were transparent at room temperature as well as at increased temperature and were able to be applied to surface coating.

Measurements and comparisons of PDDs using ion chamber and fiber-optic dosimeter irradiated by high energy photon beam (고 에너지 X-선 조사에 의한 광섬유 방사선량계와 이온 전리함의 심부선량 백분율 측정 및 비교)

  • Cho, Dong-Hyun;Jang, Kyoung-Won;Yoo, Wook-Jae;Seo, Jeong-Ki;Heo, Ji-Yeon;Lee, Bong-Soo;Cho, Young-Ho;Moon, Joo-Hyun;Park, Byung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.173-178
    • /
    • 2009
  • In this study, we have fabricated a fiber-optic dosimeter using an organic scintillator and a plastic optical fiber for measuring percentage depth dose with high energy X-ray beam. The scintillating light generated in organic sensor probe embedded in a solid water are guided by 20 m plastic optical fiber to the light-measuring device such as a photodiode- amplifier system. Using a fiber-optic dosimeter and an ion chamber, percentage depth dose curves are measured with 6 and 15 MV energies of X-ray beam whose field sizes are $2\;cm\;{\times}\;2\;cm$ and $10\;cm\;{\times}\;10\;cm$.