• Title/Summary/Keyword: 지역난방 공동주택

Search Result 31, Processing Time 0.032 seconds

국내 최초 공동주택 지역냉방 공급

  • Korea Mechanical Construction Contractors Association
    • 월간 기계설비
    • /
    • no.10 s.195
    • /
    • pp.57-62
    • /
    • 2006
  • 국내 최초 공동주택 지역냉방 공급으로 주거문화의 질이 향상될 전망이다. 안산도시개발(주)는 지난 7월 안산시 사동에 위치한 푸른마을 3단지에서 지역냉방시설 준공식을 갖고, "국내 최초로 공동주택 지역냉방을 공급했다" 고 밝혔다. 안산도시개발은 이번 준공에 따라 안산지역에 지역난방 뿐만 아니라 공동주택에도 지역냉방을 공급하는 전국 최초의 공동주택 지역냉방을 도입하게 돼 주거문화의 질을 향상시키는 기반을 마련했다.

  • PDF

Establishing a Energy Utilization Database for Energy Performance Evaluation of Multi-Family Housing using District Heating (지역난방 공동주택의 에너지 성능 평가를 위한 공동주택 단지별 에너지사용량 Database 구축)

  • Jeong, Jaewook;Hong, Taehoon;Ji, Changyoon;Leigh, Seung-Bok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.5
    • /
    • pp.105-113
    • /
    • 2015
  • In order to evaluate the energy performance of buildings, it is important to determine reliable information of energy utilization during operating phase. It is also required to establish the database which have the amounts of population deducted by objective filtering and analysis. In this study, all energy sources were applied to evaluate synthetically the energy performance of Multi-Family Housings(MFH) using district heating and the amounts of population were obtained sufficiently through data searching in Seoul and neighbor cities. Finally the database of source energy utilization and $CO_2$ emission in 325 MFH complexes were established through cross validation between data sources and statistical analysis. Additionally, further ideas have been proposed to improve existing MFH Management Information System.

공동주택 최초 지역냉방시스템 현장

  • Park, Jeong-Mi
    • The Magazine for Energy Service Companies
    • /
    • s.42
    • /
    • pp.30-31
    • /
    • 2006
  • 경기도 안산시 사동 푸른마을 3단지 주민들은 남들이 쓰는 에어컨 비용의 3분의 1만 내고도 원하는 시간에 에어컨을 사용하고 쾌적함까지 맛보고 있다. 바로 지역냉장시스템 덕분이다. 이 시스템은 공동주택으로서는 전국 최초로 시범설치된 것으로 하절기 소각열 등 버려지는 열을 이용해 에너지비용을 절감하면서도 프레온가스를 사용하지 않아 친환경적이다. 이 사업은 지난 2001년부터 안산지역에 지역난방을 공급하고 있는 안산도시개발(주)이 시행되고 있다.

  • PDF

Heating Energy Consumption Analysis of the Apartment Applied District Heating System (지역난방 공동주택의 단지별 난방사용량 분석 연구)

  • Park, Sun-Hyo;Lee, Hyun-Jung;Kwon, Kyung-Woo;Lee, Byung-Seok;Kim, Yang-Sub
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.293-298
    • /
    • 2012
  • The purpose of this study is performance validation of district heating apartments about heating energy consumption and analysis of energy consumption by unit characteristics. The heating energy consumption of the existing apartments was analyzed and the analyzed results will be used for energy saving technology development and policy making. The heating energy consumption data about total 78 apartment complexes, 56,910 units in Gangnam-Gu, Seoul, Korea were investigated from October, 2010 to April 2011. The analysis results are as follows; The mean heating energy consumption is 98[kWh/m2]. The energy consumption of Apgujung-Dong, Daechi-Dong is higher than that of mean valuse. The energy consumption deviation by deterioration, unit area, core type and regional group is very high. Specially, building deterioration casts a long shadow.

  • PDF

Analysis of Heating Energy Consumption of District Heated Apartment with respect to Reinforcement of Building Energy-saving Design Criteria (지역난방 공동주택의 건축물 에너지절약 설계기준 강화에 따른 난방에너지 사용량 분석)

  • Lee, Sung-Woo;Chung, Kwang-Seop;Kim, Young-Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.7 no.2
    • /
    • pp.16-22
    • /
    • 2011
  • Since 1970s, energy-saving design criteria of buildings has been improved through numerous revisions. The purpose of this research is to show how energy saving design criteria affects heating energy consumption of apartments using district heating. Heating energy consumption has been measured in 4 apartments located in Gyeonggi province, Korea from Nov. 1,2007 through Oct. 31, 2008. Collected data was regressed to linear correlations. Heating energy consumptions were calculated for past, present and future energy-saving design criteria, which are outdoor temperature, ventilation and insulation. The results show that present design criteria has reduced heating energy consumption by 15%, and the future criteria will reduce the energy consumption by 42% compared to the criteria before 2001.

Prediction of Heating Load for Optimum Heat Supply in Apartment Building (공동주택의 최적 열공급을 위한 난방부하 예측에 관한 연구)

  • Yoo, Seong-Yeon;Kim, Tae-Ho;Han, Kyou-Hyun;Yoon, Hong-Ik;Kang, Hyung-Chul;Kim, Kyung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.803-809
    • /
    • 2012
  • It is necessary to predict the heating load in order to determine the optimal scheduling control of district heating systems. Heating loads are affected by many complex parameters, and therefore, it is necessary to develop an efficient, flexible, and easy to use prediction method for the heating load. In this study, simple specifications included in a building design document and the estimated temperature and humidity are used to predict the heating load on the next day. To validate the performance of the proposed method, heating load data measured from a benchmark district heating system are compared with the predicted results. The predicted outdoor temperature and humidity show a variation trend that agrees with the measured data. The predicted heating loads show good agreement with the measured hourly, daily, and monthly loads. During the heating period, the monthly load error was estimated to be 4.68%.

A Study on Improved Operation of Apartment Heating System in a Machine Room (공동주택 기계실 난방설비 운전 개선 연구)

  • Seo, Jeong-Ah;Shin, Younggy;Kim, Yong-Ki;Lee, Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.1
    • /
    • pp.38-42
    • /
    • 2017
  • This study proposes an idea for energy saving in apartment machine rooms. A conventional district heating system is equipped with constant-flow pumps and bypass valves to regulate pump differential pressure. Each family unit is equipped with a constant-flow on/off valve. This leads to excessive hot water circulation and a high return temperature. To reduce energy loss, this study assumes that each family unit is renovated with a heating valve which regulates the return temperature at $35^{\circ}C$. The hot water supply pump is also replaced with a pump with an inverter to vary flow rate. Expected energy savings is then estimated from field test data. According to the results, pump electricity consumption was reduced by 6,100 kWh for a family unit building over about half a year. The supply temperature can also be lowered by $5^{\circ}C$, which can contribute to a production of electricity of 10.3 kWh/ton of hot water.