• Title/Summary/Keyword: 지수판

Search Result 235, Processing Time 0.029 seconds

Fabrication, Durability and Structural Characteristics of Composite Bridge Deck of Hollow Section (중공단면 복합소재 교량 바닥판의 제작성, 내구성 및 구조거동평가)

  • Lee Sung-Woo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.18 no.4 s.70
    • /
    • pp.427-434
    • /
    • 2005
  • In this study, to develop composite bridge deck of many advantages such as light weight, high strength, corrosion resistance and high durability, profile design, laminate design and finite element analysis were carried out. In the analysis, 5-girder single span bridge with composite deck was considered. Deflection serviceability, failure criteria and web buckling were evaluated. Composite deck of designed profile was fabricated with pultrusion process. The coupon tests were conducted for the fabricated deck and the results were described.

Comparison of Dose and Quality of Copper and Nickel Additional Filter Plate in Diagnostic X-ray Generator (진단용 엑스선 발생장치에서 부가 여과판에 따른 선량과 화질 비교)

  • Lee, Hyun-Kyung;Go, Yu-Rim;Park, Young-Kyeong;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.459-466
    • /
    • 2017
  • The purpose of this study was to evaluate the difference of dose and image quality according to the material of the additional filter plate by selecting copper and nickel. First, the absorbed dose was measured using a Rando phantom setting the additional filter plates of copper and nickel None, 0.1 mm, 0.2 mm, and 0.3 mm under 120 kVp, and 6.3 mAs. Second, We acquired image according to filter thickness of copper and nickel. by changing the tube voltage of 90 kVp, 100 kVp, 110 kVp, 120 kVp and exposure indexes of 400, 800 and 1600. Third, we obtained the SNR and CNR values using the Image J program and evaluated quantitatively and then evaluated image quality. As a result, Absorbed dose measurements showed that nickel was higher than copper, and the absorbed dose decreased as the thickness increased(p<0.05). Furthermore, Quantitative analysis of images showed no significant difference between the two images according to change the voltage and the exposure index(p>0.05). In conclusion, this study confirms that the nickel addition plate can maintain the current image quality while reducing the exposure dose compared to copper.

Application of Incidence Angle on Lumbar Spine Anteroposterior General Radiography Image according to Measured Intervertebral Disc Angle (방사선 일반 정면검사에서 허리뼈 추간판 계측 값에 따른 입사각 적용)

  • Moon, Seul-Ji-A;Kim, Gyeong-Rip;Cho, Hee-Jung;Sung, Soon-Ki;Kwak, Jong-Hyeok
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.6
    • /
    • pp.471-480
    • /
    • 2019
  • L-spine 3~4, L-spine 4~5, and L-spine 5~Sacrum 1 intervertebral disc(IVD) angle according to gender, age, body mass index(BMI), lumbar lordosis angle(LLA) were compared and analyzed. The anteriorposterior incidence angle of L-spine 3 ~ 4, L-spine 4 ~ 5 and L-spine 5~Sacrum 1 in body mass index were 5.66, 13.23 and 29.13 degrees in the head direction and L-spine 3 4, L-spine 4 ~ 5, L-spine 5~Sacrum 1 had 6.32 degrees, 16.09 degrees and 35.36 degrees in the head direction. The distortion area ratio comparison was performed with the phantom image using the proposed incidence angle. There was a significant difference in L-spine 4~5 and L-spine 5~Sacrum 1 IVD angle relative to body mass index and LLA(p<0.05), IVD angle and LLA were positively correlated(p<0.05).As a result of evaluating the usefulness of the image by applying the incidence angles of the disc angles according to the phantom angle of deviation to the head direction as 11 degrees for L4 and 26 degrees for L5, the distortion ratio area decreased from 14.90% to 12.11% in L4, And from 15.25% to 13.72% in L5. In anteriorposterior image of the Lumbar spine applying the incidence angle according to the measured disc angle, it is possible to reduce the distortion to purpose L4, L5. And improved the quality and diagnostic information of the target site.

Competitiveness Analysis of Forest Products for the Korea-EU FTA (한-EU FTA에 대비한 임산물 경쟁력 분석)

  • Lee, Sang-Min;Chang, Cheol-Su
    • Journal of Korean Society of Forest Science
    • /
    • v.98 no.3
    • /
    • pp.231-241
    • /
    • 2009
  • Trade specialization index, import market share, unit value index, market comparative advantage index have been applied to compare the competitiveness of forest products in Korean and European markets for the case of Korea-EU FTA. The results say that no items of non-timber products would show a surge of imports as a result of FTA. Timber products, however, such as non-coniferous plywood, continuously shaped wood (non-coniferous), densified wood, wood wool and flour, other (plywood), other (particle board, 441039)), other (fiberboard), oriented strand board (other), other (particle board, 441090), other (particle board, 441031), Prefabricated buildings of wood, fibreboard (of a density exceeding $0.5g/cm^3$ but not exceeding $0.8g/cm^3$), wooden frames (for paintings, photographs, mirrors or similar objects) and wood marquetry and inlaid wood are expected to increase of their imports by eliminating tariffs. For Korean exports no items of non-timber products have competitiveness in European market. For Korean pyroligneous liquid, which is the only competitive timber product in EU market in terms of MCA and TSI, it is difficult to decide whether it has competitiveness, since the actual exports have taken place occasionally during a period of last five years.

Results of Arthroscopic-assisted Minimally Invasive Removal of a Lateral Periarticular Plate used for the Treatment of AO Type-C Distal Femoral Fractures (AO C-형 원위 대퇴골 골절의 치료로 삽입된 관외측 금속판의 절경 보조하 최소 침습적 제거의 결과)

  • Kim, Young-Mo;Lee, June-Kyu;Yang, Jae-Hoon;Kim, Bo-Kun;Lee, Won-Gu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Purpose: To evaluate the usefulness of minimally invasive arthroscopy-assisted plate removal of a laterally inserted periarticular distal femur plate used for the treatment of AO type-C distal femur fractures. Materials and Methods: From October 2002 to November 2005, we evaluated 17 patients whose plates were removed through minimally invasive arthroscopy-assisted plate-removal technique and 15 patients who got their plates removed through conventional method without using arthroscopy, 32 patients in total. All these patients included in this study initially underwent open reduction and internal fixation of the distal femoral fractures with a lateral plate, and complained of continued pain over the lateral femoral condyle after the fracture fixation. The average age was 42.6 (ranges: 20~66) and initial fracture types included 16 cases of C1, 11 cases of C2, and 5 cases of C3 following AO/ASIF classification guidelines. Measured outcomes included: associated intra-articular pathologies, time needed to return to activities of daily living, patients' overall satisfaction, complications following the removal of hardware, and pain before and 6 months after the operation. Results: The distal-most end of the plate was placed in the knee joint in all cases and damage of the lateral articular capsule was found in 23 cases. Continuous wound discharge after surgery was found in one case who underwent arthroscopy-assisted plate removal, and it was treated by irrigation and re-suture. Average time needed to return to activities of daily living was 7 days in arthroscopy assisted group and 7.6 days in conventionally removed group. Fourteen patients (82.4%) who underwent arthroscopyassisted plate-removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 4.9 to 1.9, six months after the plate removal. Thirteen patients(86.7%) who underwent conventional plate removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 5.2 to 2.5, six months after the operation. Conclusion: Through minimally invasive arthroscopic-assisted plate removal, intrarticular pathology of the knee joint was able to be simultaneously identified and treated at the time of hardware removal. Damage of lateral capsule of the knee joint caused by the inserted plate for the treatment of type C distal femoral fracture was very frequently found and following the plate removal, patients experienced an improvement in pain score. We therefore recommend routine lateral distal femoral plate removal if the bony union is attained in such cases as type C distal femoral fractures whose distal most end of the plates are located in the joint.

  • PDF

Risk of Smoke Occurring in the Combustion of Plastics (플라스틱의 연소 시 발생하는 연기 위험성에 관한 연구)

  • You, Jisun;Chung, Yeong-jin
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.69-75
    • /
    • 2019
  • In this study, the combustibility of five types of plastic plates, fiber reinforced plastic (FRP), polystyrene (PS), polycarbonate (PC), polypropylene (PP), and polyvinyl chloride (PVC), were tested using a cone calorimeter (ISO 5660). The PVC plate showed a $44.65kW/m^2$ lower peak heat release rate (HRR) and a $30.97kW/m^2$ lower maximum average rate of heat emission than the other four types of plastics, whereas the PS plate showed a $773.44kW/m^2$ higher peak HRR and $399.14kW/m^2$ higher maximum average rate of heat emission. The PC plate and PS plate showed the highest HRR by a maximum of 3.88 times in $CO_{mean}$ yields, while the PS pate and PP plate showed the highest HRR by a maximum 4.88 times in $CO_{2mean}$ yields. In addition, the smoke performance index (SPI) of the PS plate decreased by 74.81%~95.99%; the smoke growth index (SGI) increased to 76%~300%; the smoke intensity (SI) also increased to 917.73% ~ 9607.57%, and the danger of smoke increased. The PS plate was found to have the highest risk of life damage due to smoke on the thermal and smoke sides.

A Study on the Effect of Applying Water Seepage Lowering Method Using Swelling Waterstop for Expansion Joint in the Concrete Dam (콘크리트 댐에서 수축이음부의 수팽창성 차수재를 이용한 침투저감 공법 적용효과 연구)

  • Han, Kiseung;Lee, Seungho;Kim, Sanghoon;Kim, Sejin;Pai, Sungjin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.10
    • /
    • pp.21-29
    • /
    • 2021
  • Most concrete gravity-type dams in and out of the country were constructed by column method to control cracks caused by concrete hydration heat generated during construction, resulting in a certain level of leakage after impoundment through various causes, such as contraction joints and construction joints. However, due to the characteristics of concrete structures that shrink and expand according to temperature, concrete dams have vertical joints and drains to allow penetration. PVC waterproof shows excellent effects in completion of the dam, which however increases the possibility of interfacial failure due to different thermal expansion. Other causes of penetration may include problems with quality control during installation, generation of cracks due to heat of hydration of concrete, waterproofing methods, etc. In the case of Bohyunsan Dam in Yeongcheon, North Gyeongsang Province, the amount of drainage in the gallery was checked and underwater, and it was confirmed that there are many penetrations from drainage holes connected to vertical joints, and that some of the PVC waterproofs are not fully operated. As a new method to prevent penetration through vertical joints, D.S.I.M. (Dam Sealing Innovation Method) developed by World E&C was applied to Bohyunsan Dam and checked the amount of drainage in the gallery. As a result of first testing three most leaking vertical joints, the drain in the gallery was reduced by 87% on the average and then applied to the remaining 13 locations, which showed a 83% reduction effect based on the total drain in the gallery. Summing up these results, it was found that D.S.I.M. preventing water leakage from the upstream face is a valid construction method to reduce the water see-through and penetration quantity seen in downstream faces of concrete dams. If D.S.I.M. is applied to other concrete dams at domestic and abroad, it is expected that it will be very effective to prevent water leakage through vertical joints that are visible from downstream faces.

A Study on the Relation of Rebar Corrosion Rate and the Strength Reliability Index of RC Slab Decks having Chloride Contamination (염해 손상을 받는 RC 교량 바닥판의 강도 신뢰성 지수와 철근 부식도 등급과의 관계 연구)

  • Cha, Chul-Jun;Park, Mi-Yun;Cho, Hyo-Nam
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.2
    • /
    • pp.121-128
    • /
    • 2005
  • This study focuses on evaluating the reliability index of a deck of RC slab having chloride contamination and studying the relation of grades of rebar corrosion and the reliability index of a bridge deck For this purpose, first, the failure probability related to flexural strength was calculated using a model for deterioration, which contains the application of deicing salts that usually causes significant long-term deterioration and reduction in the structural safety for strength of structure. And also, according to the depth of covering, the chloride contents depending on time due to depths of RC slab deck, the appearance time for initial corrosion of rebar and the occurrence time for split of covering were investigated using a MCS method.

Optical Simulation Study of the Improvement of Color-rendering Characteristics of White Light-emitting Diodes by Using Red Quantum-dot Films (적색 양자점 필름을 이용한 백색 발광 다이오드의 연색성 개선에 대한 광학 시뮬레이션 연구)

  • Lee, Gi Jung;Hong, Seung Chan;Lee, Jung-Gyun;Ko, Jae-Hyeon
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.4
    • /
    • pp.163-171
    • /
    • 2021
  • Conventional white light-emitting diodes (LEDs) for lighting applications consist of blue LEDs and yellow phosphors, the spectrum of which lacks deep red. To improve the color-rendering characteristics of white LEDs, a red quantum-dot film was applied to the diffuser plate of LED lighting. The mean free paths of the quantum dots and the concentration of the TiO2 particles in the diffuser plate were adjusted to optimize the optical structure of the lighting. The color-rendering index (CRI) was greater than 90 for most conditions, which demonstrates that adoption of the red quantum-dot film is an effective way for improving the color-rendering properties of conventional white LEDs. The angular dispersion of color coordinates could be removed by utilizing the optical cavity formed between the diffuser plate and the reflector on the bottom of the lighting, where multiple passages of the light through the quantum-dot film reduced the differences in optical path length depending on the viewing angle.