• Title/Summary/Keyword: 지붕면

Search Result 68, Processing Time 0.026 seconds

An Experimental Runoff Formula in Building Roof Area for On-site Rainwater Management (On-site 방식 빗물관리를 위한 건축물 지붕면의 유출특성 경험식 수립)

  • Kim, Young-Jin;Han, Moo-Young;Kim, Yong-Ha;Mun, Jung-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.2
    • /
    • pp.171-176
    • /
    • 2009
  • This study proposes an experimental formula for cumulative runoff analysis in building roof for on-site rainwater management. We can not find an appropriate method for roof runoff analysis because of its small area scale. A new runoff equation formula for rainfall depth(D) and cumulative runoff volume(V) is developed on roof runoff conditions. Reliability of the formula is verified with field experimental runoff monitoring for two years in two buildings of rainwater management system. This experimental runoff formula can root the cumulative runoff volume from roof area and rainfall depth, then develop reasonable inflow condition for rainwater retention tank design.

An Experimental Study on Characteristics of Wind Pressure on Long-Span Roof of the Kwangju World Cup Stadium (광주월드컵 경기장 지붕면의 풍압특성에 관한 실험적 연구)

  • Park, Yeon Soo;Kim, Yun Seok;Park, Sun Joon
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.5 s.48
    • /
    • pp.495-502
    • /
    • 2000
  • In this study, the wind tunnel test for Kwangju World Cup Stadium with long span roof was carried out and its results were considered in the two roofs: one is the case of one roof, and the other is the case of two roofs which are identical. In this experiment, a 1/400-scale model was used. As a result of measuring wind pressure in the case of one roof and then two, when two roofs are set up, wind load for structural frame decreases by 35%, compared to that of one roof. These results show that the current criteria for wind loadings, which specify that wind pressure on the roof depends only on the altitude, have limitations for adoption, and a wind tunnel test is essential to design.

  • PDF

The Effect of Roofing Materials for Using Harvested Rainwater (집수빗물이용을 위한 지붕면 재질의 영향)

  • Lee, Ju Young;Kim, Tschung-Il;Kim, Hyunwoo;Han, Mooyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.9
    • /
    • pp.623-629
    • /
    • 2012
  • The objective was to evaluate the quality of harvested rainwater of the roofing materials used and the presence of lichens/mosses on the roofing surface. This experiment was studied in the field where five pilot structures with different roofing materials (i.e., wooden shingle tiles, wooden shingle tiles (including mosses), concrete tiles, clay tiles [Gi-Wa] and slate tiles) were installed. As a result, the clay tiles [Gi-Wa] was found to be the most suitable for rainwater harvesting applications. It was due to the disinfection from ultraviolet light and high temperature according to characteristic of roofing materials. Comparison with quality of rainwater on that wooden shingle tiles with and without including mosses, which may affect the concentration of and wooden shingle tiles including mosses, mosses may affect concentration of TOC, nitrate, and sulfate. Additionally, the average concentration of asbestos was determined to be measured at $0.002/cm^3$ for the slate tiles. The value satisfied with it met the Ministry of Environment's Multi-use facility standard and Ministry of Labor's Office standard ($0.01/cm^3$).

Analysis of the Characteristics of Peak External Pressure Coefficient Working on Roof Surface according to the Shape and Layout of Green Houses (비닐하우스의 형태와 배치에 따른 지붕면 피크외압계수 특성분석)

  • You, Ki-Pyo;Paek, Sun-Young;Kim, Young-Moom
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.1
    • /
    • pp.59-66
    • /
    • 2010
  • Among the protected horticulture facilities in Korea, 99.2% are pipe-framed green houses and most of them are structurally vulnerable single-span type green houses. This study examined peak external pressure coefficient for the roof surface of a green house group composed of single-span and a multiple-span green houses. According to the results of the experiment, the distribution of peak external pressure coefficient was around 30% higher in the single-span greenhouse than in the multi-span ones. The external pressure coefficient for the roof surface of the vinyl house group was, in all of the three vinyl houses, was around 20%-30% higher than that for single-span greenhouses.

  • PDF

Analysis of the Wind Pressure Coefficient Characteristic of Livestock Shed Roof Surface according to the Opening of Side Walls (측벽 개방유무에 따른 축사지붕면의 풍압계수 특성분석)

  • You, Ki-Pyo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.2
    • /
    • pp.63-70
    • /
    • 2011
  • Livestock buildings are rural facilities as vulnerable to natural disasters as vinyl houses. Many of livestock buildings have a roof but without side walls. The roof of such structures is easily blown away by a typhoon and this results in a heavy loss. Therefore, farmers install winch curtains on the sides to prevent damages caused by typhoons. This study purposed to examine the distribution of wind pressure coefficient among different positions of livestock shed roof according to the opening of side walls. It was found that according to the distribution of peak external pressure coefficient on the roof surface of livestock shed, the wind blowing at wind angle $0^{\circ}$ was disadvantageous to roof surface regardless of the presence of side walls. However, it was confirmed that the peak external pressure coefficient was affected by wind angle and the length of eave depending on the presence of side walls.

Automatic Generation of 3D Building Models using a Draft Map (도화원도를 이용한 3차원 건물모델의 자동생성)

  • Kim, Seong-Joon;Min, Seong-Hong;Lee, Dong-Cheon;Park, Jin-Ho;Lee, Im-Pyeong
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.15 no.2 s.40
    • /
    • pp.3-14
    • /
    • 2007
  • This study proposes an automatic method to generate 3D building models using a draft map, which is an intermediate product generated during the map generation process based on aerial photos. The proposed method is to generate a terrain model, roof models, and wall models sequentially from the limited 3D information extracted from an existing draft map. Based on the planar fitting error of the roof corner points, the roof model is generated as a single planar facet or a multiple planar structure. The first type is derived using a robust estimation method while the second type is constructed through segmentation and merging based on a triangular irregular network. Each edge of this roof model is then projected to the terrain model to create a wall facet. The experimental results from its application to real data indicates that the building models of various shapes in wide areas are successfully generated. The proposed method is evaluated to be an cost and time effective method since it utilizes the existing data.

  • PDF

Optimum Design of Greenhouse Roof Shape Using Genetic Algorithms - In Reference to Light Transmissivity - (유전알고리즘을 이용한 온실지붕형상의 최적설계 - 광투과율을 중심으로 -)

  • 박우식;김문기
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1998.05a
    • /
    • pp.4-10
    • /
    • 1998
  • 온실운영에 있어서 가장 심각한 문제는 다량의 에너지 소비이며 이 문제를 해결하기 위해서는 포괄적인 열환경해석을 통한 에너지면에서 최적화된 온실모델의 개발이 필요하다. 따라서 태양광의 투과율을 중심으로 에너지 면에서 최적인 즉, 겨울철에 최대의 태양에너지를 투과할 수 있도록 하는 온실의 지붕형태를 결정하는 것은 의미 있는 일이라 하겠다. (중략)

  • PDF

The Implementation of an Roof Structure Generating Tool based on the Structural Analysis of Roof Curvature in Traditional Buildings (전통건축 지붕곡 구조분석을 통한 지붕가구부 설계도구의 구현)

  • Lee, Hyunmin;Ahn, Eunyoung
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.3
    • /
    • pp.393-404
    • /
    • 2014
  • This research proposes a method to draw a number of components for roof frame in 3D datum. It is based on the analysis of the roof curvature and their geometric relationship in the traditional wooden buildings. Correlations between the components that generate a roof surface is defined with functional formula. The design system which automatically generates 3D datum for the components is implemented by reflecting the structural mechanics for them. The suggested system provides a control function to easily draw a traditional house. In this system, the components engaged in forming a roof surface are not only automatically generated but also simply modified according to the user's request. It would improves design efficiency and ensure a various roof surface design. Furthermore it makes possible systematic drawing and standardized industrial processing. Consequently, the proposed method is expected to contribute to the popularization of traditional house constructing.

A Determination Method of a Rainwater Retention-Pumping System Combination for Runoff Control from Building Roof Area (지붕면 유출제어를 위한 빗물의 저장-펌프 시스템 조합 결정방안)

  • Kim, Young-Jin;Han, Moo-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.495-499
    • /
    • 2008
  • This study developed a determination method for a rainwater retention-pumping combination system for roof runoff control. The outflow and stored water volume in the rainwater system was simulated using a water balance equation. Its result is presented in the TPP (Tank capcity-Peak outflow-Pumping rate) curves for rainfall return periods. In a case study on reduction of the peak flow rate of 100-year return period to 5-year in Seoul, The range of pumping rate for $100m^2$ roof area is determined as $0{\sim}25{\ell}$/min. Additionally, retention volume of $8.5{\sim}10m^3$ can be combined with the pumping rate range. That is to say an effective combination of a retention-pumping system capacity can be determined from a system of $8.5m^3$ tank with $25{\ell}$/min to $10m^3$ tank without pump. Using the TPP curves, engineers can determine the effective combination range of retention & pumping system capacity. Furthermore, that can be helpful to decide a detail system capacity for field condition.

  • PDF

Feature Extraction from Rasterized Forms of Lidar Data (라이다 자료로부터 라스터 형태에 기반한 형상 추출기법 연구)

  • Seo, Su-Young;Jin, Hai-Ming
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2008.10a
    • /
    • pp.144-145
    • /
    • 2008
  • 본 연구는 라이다 자료를 이용하여 건물영역을 추출하고 건물모델을 구성하는 선형과 면요소들을 추출하는 기법을 제시하였다. 라이다 자료는 지형지물의 표고값을 정확하고 직접적인 방식으로 제공함으로써 기존의 항공사진에 비하여 매칭과정을 필요로 하지 않는 장점을 가지고 있다. 하지만 라이다 점들은 해당 수평위치에 대한 표고값만을 제공하기 때문에 지표 위의 지형지물들을 추출하기 위해서는 먼저 점들간의 기하학적인 관계를 분석하여 그들을 구성하는 선이나 면요소들을 추출해야 한다. 이를 위하여 본 연구에서는 먼저 라이다 자료를 라스터 형태로 변환한 후, 이미지 프로세싱을 통하여 상대적으로 낫은 영역과 높은 영역으로 분리하여 각각 지형과 건물영역으로 분류하였다. 다음으로 건물영역 경계로부터 건물 외곽선을 추출하고 건물영역 내에 면요소들을 통계분석을 통하여 추출하였다. 실험결과를 통하여 제시한 기법들은 비교적 복잡한 형태의 건물 지붕면과 외곽선을 성공적으로 분할하고 추출할 수 있음을 보여준다.

  • PDF