• Title/Summary/Keyword: 지반 분류

Search Result 452, Processing Time 0.022 seconds

Development and Calibration of 3-Component Vibration Transducer (3방향 진동감지기의 제작 및 검증)

  • Kim, Dong-Su;Lee, Jin-Seon;Jo, Seong-Ho
    • Geotechnical Engineering
    • /
    • v.13 no.4
    • /
    • pp.121-134
    • /
    • 1997
  • Vibrations induced by traffic loading and construction activities are extremely important due to their potential to cause damage to adjacent structures and toy complaints to the neighbors. Vibration induced damage to the built environment may be caused by the direct transmission of vibrations as well as by the, vibration induced differential settlement. In order to effectively control the vibration related problems, the accurate in-situ vibration monitoring is essential. In this paper, a calibration technique of a geophone which is widely used in practice was described. Once the frequency characteristics of individual geophones were calibrated, the 3fomponent geophone was developed for the in-depth vibration measurement, and the dot ailed calibration and application techniques of the 3fomponent geophone were described. Vibrations caused by blasting, train loading, and pile driving were measured and the applicability of the 3fomponent geophone was assessed.

  • PDF

New guideline for geomechanical design/construction of conventional NATM tunnels (NATM 터널 설계/시공을 위한 새로운 가이드라인 고찰)

  • Kim, Chang-Yong;Hong, Sung-Wan;Kim, Kwang-Yeom;Baek, Seung-Han;Bae, Gyu-Jin;Schubert, Wulf
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.1
    • /
    • pp.73-88
    • /
    • 2005
  • Three approaches presently used for the design of underground structures in rock mass are quantitative rock mass classification system, classification systems based on the behavior of the rock mass during excavation and general qualitative procedures for the design process. In this study their characteristics and shortcomings are discussed, and Austrian guideline for tunnel design/construction, that was proposed to solve the problems with these methods, are introduced and compared. For technically sound and economic tunnel construction, a flexible design and construction procedure is needed to cope with uncertain ground and boundary condition, and also actual ground condition should be predicted through feedback of geotechnical information obtained during construction.

  • PDF

Rock Support Design of Bakun Tunnelling Project in Sarawak, Malaysia (바쿤 가배수로 터널의 최적지보설계)

  • 지왕률
    • Tunnel and Underground Space
    • /
    • v.8 no.4
    • /
    • pp.296-306
    • /
    • 1998
  • Ongoing huge Bakun Hydropower project is including the construction of a 210 m height hydroelectric rockfill dam with an installed capacity of 2,520 MW and a power transmission system connecting to the existing networks between Sarawak and peninsula Malaysia. In order to allow the main dam construction during the dry season, the Ballui river will have to be detoured through 3 concrete lined diversion tunnels with an internal diameter of 12 m and a length of 1,400 m each. The geology of Bakun site belongs to the several thousand meters thick Belaga formation deposited from the late Cteteceous to the early Teriary in the Northwest Borneo geosyncline. The orientation of the bedding plane, strike at N55$^{\circ}$E to N70$^{\circ}$E and dip at 50$^{\circ}$SE to 70$^{\circ}$SE, is developed uniformly in Bakun sedimentary rocks. Rock mechanical characteristics of Bakun site have been classified into 4 rock mass types(RMT) depending on the degree of weathering and the occurrence of rock jointing with RMR. Graywacke(Sandstone) as well as Shale can take place together in the same rock mass type if their rock mass properties are similar. It was summarized the rock support type and support system design of underground diversion tunnels in view of rock mechanics.

  • PDF

Rock Classification and Aggregate Evaluation of Tertiary Unconsolidated Deposits (미고결 퇴적층의 암반분류와 재료원 평가)

  • Kim, Sung-Wook;Lee, Kyu-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.7
    • /
    • pp.25-36
    • /
    • 2010
  • Tertiary unconsolidated mudstones spread throughout the eastern coast area. The demand for high quality filling materials in these areas is increasing due to harbors and large-scale residential land development. Rock produced in-situ or near site has been used as road subbase construction or reclamation materials for economical reason, but it is hard to decide appropriateness of quality specification because of its characteristics. The test results showed that unconsolidated rocks are diversely considered according to a different method of the applied geotechnical investigation. Therefore, the site of tertiary unconsolidated mudstones, the classification of rock and evaluation of rock properties that must be evaluated by objective criteria and apply a different set of criteria are needed. In addition, the environmental impact must be considered due to acid mine drainage.

A Method of Developing a Ground Layer with Risk of Ground Subsidence based on the 3D Ground Modeling (3차원 지반모델링 기반의 지반함몰 위험 지반 레이어 개발 방법)

  • Kang, Junggoo;Kang, Jaemo;Parh, Junhwan;Mun, Duhwan
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.12
    • /
    • pp.33-40
    • /
    • 2021
  • The deterioration of underground facilities, disturbance of the ground due to underground development activities, and changes in ground water can cause ground subsidence accidents in the urban areas. The investigation on the geotechnical and hydraulic factors affecting the ground subsidence accident is very significant to predict the ground subsidence risk in advance. In this study, an analysis DB was constructed through 3D ground modeling to utilize the currently operating geotechnical survey information DB and ground water behavior information for risk prediction. Additionally, using these results, the relationship between the actual ground subsidence occurrence history and ground conditions and ground water level changes was confirmed. Furthermore, the methodology used to visualize the risk of ground subsidence was presented by reconstructing the engineering characteristics of the soil presented according to the Unified Soil Classification System (USCS) in the existing geotechnical survey information into the internal erosion sensitivity of the soil, Based on the result, it was confirmed that the ground in the area where the ground subsidence occurred consists of more than 40% of sand (SM, SC, SP, SW) vulnerable to internal erosion. In addition, the effect of the occurrence frequency of ground subsidence due to the change in ground water level is also confirmed.

Suggestion of Additional Criteria for Site Categorization in Korea by Quantifying Regional Specific Characteristics on Seismic Response (지역고유 지진응답 특성 정량화를 통한 국내 부지 분류 기준의 추가 반영 제안)

  • Sun, Chang-Guk
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.3
    • /
    • pp.203-218
    • /
    • 2010
  • The site categorization and corresponding site amplification factors in the current Korean seismic design guideline are based on provisions for the western United States (US), although the site effects resulting in the amplification of earthquake ground motions are directly dependent on the regional and local site characteristic conditions. In these seismic codes, two amplification factors called site coefficients, $F_a$ and $F_v$, for the short-period band and midperiod band, respectively, are listed according to a criterion, mean shear wave velocity ($V_S$) to a depth of 30 m, into five classes composed of A to E. To suggest a site classification system reflecting Korean site conditions, in this study, systematic site characterization was carried out at four regional areas, Gyeongju, Hongsung, Haemi and Sacheon, to obtain the $V_S$ profiles from surface to bedrock in field and the non-linear soil properties in laboratory. The soil deposits in Korea, which were shallower and stiffer than those in the western US, were examined, and thus the site period in Korea was distributed in the low and narrow band comparing with those in western US. Based on the geotechnical characteristic properties obtained in the field and laboratory, various site-specific seismic response analyses were conducted for total 75 sites by adopting both equivalent-linear and non-linear methods. The analysis results showed that the site coefficients specified in the current Korean provision underestimate the ground motion in the short-period range and overestimate in the mid-period range. These differences can be explained by the differences in the local site characteristics including the depth to bedrock between Korea and western US. Based on the analysis results in this study and the prior research results for the Korean peninsula, new site classification system was developed by introducing the site period as representative criterion and the mean $V_S$ to a depth of shallower than 30 m as additional criterion, to reliably determine the ground motions and the corresponding design spectra taking into account the regional site characteristics in Korea.

Assessment of Response Spectrum by Dynamic Centrifuge Test for the Pile Foundation into the Sand (동적 원심모형실험에 의한 사질토에 근입된 말뚝지지 기초의 응답 스펙트럼 분석)

  • Park, Yong-Boo;Park, Jong-Bae;Kim, Sang-Yeon;Kim, Dong-Soo
    • Land and Housing Review
    • /
    • v.5 no.1
    • /
    • pp.35-40
    • /
    • 2014
  • Site coefficient and amplification factor of current domestic Seismic Design Code (KBC-2009) have no consideration for the domestic ground condition in which the base rock is normally placed within 30m form the surface. Accordingly, in this study dynamic centrifugal test and analysis for pile foundation into sand and upper structure were achieved. and the response spectrums of free surface and basement were compared with each other. Within the period 1 sec., the measured spectral acceleration of free surface and basement was bigger than the design spectral acceleration of SC and SD site. However the measured spectral acceleration of free surface and basement for the period over 1.5 sec. was smaller than the design spectral acceleration of SC site. There was no severe difference of spectral acceleration according to the upper structure, embedded depth of foundation and free surface conditions. Consequently, normal domestic apartment housing for the period range over 1.5sec. could be design more economically applying these test result.

A Study on Earth Pressure Calculating Method about Shield TBM Tunnel Segments in the Rock (암반층에서 쉴드 TBM 터널 세그먼트의 작용하중 산정방법에 관한 연구)

  • Chun, Byungsik;Ki, Jungsu;Kang, Taehee;Kwag, Yunehyeong;Byun, Yoseph
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.5
    • /
    • pp.13-21
    • /
    • 2014
  • This study analyzed the differences in the analysis techniques through a comparative analysis of the various segment's modeling techniques of Shield TBM method and proposed reasonable modeling techniques. Also, this study suggested reasonable estimating methods of load to be applicable in the field through the load analysis and three-dimensional finite element analysis by estimating model of rock mass relaxation load. Estimating method of relaxation area by rock mass rating makes no odds of output in subgrade with high rock mass rating, but so the difference of output is large, that is judged to set conservative design off. In estimating result of rock mass relaxation area by three-dimensional analysis relaxation area of subgrade with low-grade soil was predicted to be positioned at medium-range of many methods, in case of designing segment in subgrade with low-grade soil it needs to actively review estimation of relaxation area through three-dimensional analysis reflecting mechanical tunnel excavation.

Performance of Horizontal Drainage in the Slope Using Numerical Analysis (수치해석을 이용한 비탈면 수평배수공의 성능 분석)

  • Sangyun Kim;Hoki Ban
    • Journal of the Korean GEO-environmental Society
    • /
    • v.25 no.8
    • /
    • pp.5-11
    • /
    • 2024
  • Due to the high proportion of mountainous terrain in Korean territory and the concentration of heavy rainfall during the summer season, concerns arise about the potential decrease in slope stability caused by rainfall. Installing slope drainage facilities mitigates the rise in groundwater levels due to infiltration, thus enhancing slope stability. Horizontal drains, classified as auxiliary facilities among drainage systems, lack established installation standards and related research. Slopes with installed horizontal drains have been confirmed to exhibit higher safety factors compared to those without. Furthermore, the safety factor of mimicking horizontal drains by increasing the permeability coefficient of the surrounding ground was compared with that of the conventional simulation method using the Drain function. As a result of the comparison, it was confirmed that the installation length showed better drainage performance than the installation angle in the drainage performance of the horizontal drainage hole, and it was judged that the installation length was a more important factor.

Evaluation of Site-specific Seismic Response Characteristics at Town Fortress Areas Damaged by Historical Earthquakes (역사 지진 피해 발생 읍성 지역에 대한 부지 고유의 지진 응답 특성 평가)

  • Sun, Chang-Guk;Chung, Choong-Ki;Kim, Dong-Soo;Kim, Jae-Kwan
    • The Journal of Engineering Geology
    • /
    • v.17 no.1 s.50
    • /
    • pp.1-13
    • /
    • 2007
  • In order to evaluate the local site effects at two town fortress areas in Korea where stone parapets were col-lapsed by historical earthquakes, site characteristics were assessed using site investigations such as borehole drillings and seismic tests. Equivalent-linear site response analyses were conducted based on the shear ways velocity ($V_s$) profiles and geotechnical characteristics determined from site investigations. The study sites are categorized as site classes C and B according to the mean $V_s$ to 30 m ranging from 500 to 850 m/s, and their site periods are distributed in the short period range of 0.06 to 0.16 sec, which contains the natural period of fortress wall and stone parapet. From the results of site response analyses in the study areas, for site class C indicating most of site conditions, contrary to site class B, the short-period (0.1-0.5 sec) and mid-period (0.4-2.0 sec) site coefficients, $F_a$ and $F_v$ specified in the Korean seismic design guide, underestimate the ground motion in short-period band and overestimate the ground motion in mid-period band, respectively, due to the high amplification in short period range, which represent the site-specific seismic response characteristics. These site-specific response characteristics indicate the potential of resonance in fortress walls during earthquake and furthermore could strongly affect the collapse of parapets resulted from seismic events in historical records.