• Title/Summary/Keyword: 지면 임피던스

Search Result 5, Processing Time 0.018 seconds

Numerical Analysis of Rail Noise Regarding Surface Impedance of Ground by Using Wavenumber Domain Finite and Boundary Elements (지면 임피던스를 고려한 레일 방사 소음의 파수영역 유한요소/경계요소 해석)

  • Ryue, Jungsoo;Jang, Seungho
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.4
    • /
    • pp.289-300
    • /
    • 2015
  • An important source of noise from railways is rolling noise caused by wheel and rail vibrations induced by acoustic roughness at the wheel-rail contact. In conventional approaches to predicting rail noise, the rail is regarded as placed in a free space so that the reflection from the ground is not included. However, in order to predict rail noise close to the rail, the effect of the ground should be contained in the analysis. In this study the rail noise reflected from the ground is investigated using the wavenumber domain finite element and boundary element methods. First, two rail models, one using rail attached to the rigid ground and one using rail located above rigid ground, are considered and examined to determine the rigid ground effect in terms of the radiation efficiency. From this analysis, it was found that the two models give considerably different results, so that the distance between the rail and the ground is an important factor. Second, an impedance condition was set for the ground and the effect of the ground impedance on the rail noise was evaluated for the two rail models.

Input Impedance Characteristic of Medium Voltage Power Line for High Speed Power Line Communications (고속 전력선 통신을 위한 고압 배전선로 입력 임피던스 특성 연구)

  • Lee, Jae-Jo;Lee, Won-Tae;Byun, Woo-Bong;Choi, Sung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2031-2032
    • /
    • 2006
  • 고압 배전선로를 전력선통신망으로 활용하기 위하여는 고압 배전선로에 대한 입력 임피던스에 대한 정확한 이론적 고찰과 실선로에서의 측정을 통한 검증이 요구된다. 본 논문에서는 고압 배전선로용 신호결합장치의 등가회로를 바탕으로 고압 전력선통신시스템의 입출력 모뎀을 제안한다. 제안된 시스템입출력 모델을 바탕으로 고압 배전선로의 고주파(2-30MHz) 대역의 입력 임피던스를 계산한다. 고압 배전선로 통신 입출력 모델에서 지면의 유전상수, 전력선의 길이, 지면의 도전율에 따른 배전선로 입력 임피던스의 이론적 분석과 실 선로에서의 입력 임피던스 측정 결과를 소개한다.

  • PDF

Locomotion of Biped Robots on Irregular Surface Based on Pseudo-Impedance Model (의사-임피던스 모델을 이용한 비평탄면에서의 2족보행로봇의 보행)

  • Shin, Hyeon-Sik;Park, Jong-Hyeon;Kwon, O-Hung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.6
    • /
    • pp.667-673
    • /
    • 2010
  • This paper proposes a control method based on a pseudo-impedance model to control the motion of biped robots walking on an uneven surface. The pseudo-impedance model simulates the action of the ankle of a foot landing on the ground when a human walks. When the foot is in contact with the ground, the human ankle goes through two different phases. In the first phase, the human exerts little or no effort and applies no torque on the ankle so that the orientation of the foot is effortlessly and passively adjusted with respect to the ground. In the second phase of landing, the ankle generates a significant amount of torque in order to rotate and move the main part of the human body forward and to support the weight of the human; this phase is called the weight acceptance phase. Computer simulations of a 12-DOF biped robot with a 6-DOF environment model were performed to determine the effectiveness of the proposed pseudo-impedance control. The simulation results show that stable locomotion can be achieved on an irregular surface by using the proposed model.

Analysis of Characteristic Parameter in Medium Voltage Power Distribution Line for Power Line Communications (전력선 통신을 위한 고압 배전선로 특성 파라미터 해석)

  • Lee, Jae-Jo;Park, Hae-Soo;Lee, Won-Tae;Kim, Kwan-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2029-2030
    • /
    • 2006
  • 본 논문에서는 22.9kV 고압 가공 배전선로를 고속 전력선 통신을 위한 통신 채널로 사용하기 위하여 전력선 통신 주파수 $2MHz{\sim}30MHz$ 대역에 대한 특성 파라미터를 해석하였다. 먼저 고압 배전선로에 주로 사용되는 ACSR-OC 케이블에 대한 구조를 분석하고 이의 특성 파라미터로부터 분포정수와 특성 임피던스를 구하였다. 또한 등각 사상법을 이용하여 유전체가 코팅된 평행 2선식 고압 배전선로의 정전용량 및 유효유전상수를 계산하였다. 이러한 결과를 바탕으로 고압 배전선로의 분포정수와 특성임피던스를 구하였으며, 특성임피던스는 케이블 단면적에 따라서 $470{\ell}{\sim}530{\ell}$ 사이의 분포를 나타내었다. 특히, 특성 임피던스는 지면을 완전 전기도체로 가정할 경우에 비하여 실제 지면의 도전율과 유전상수를 고려할 때 20MHz 이하의 대역에서 보다 높은 값을 갖는 것을 확인하였다.

  • PDF

The propagation characteristics of road traffic noise - with respect to human response - (도로 교통소음의 전파특성 연구 - 인체에 미치는 영향에 대한 고찰 -)

  • 장호경
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.19-27
    • /
    • 2000
  • In order to predict the propagation of road traffic noise over level terrain, this paper presents the model of the simple monopole and dipole source. Excess attenuations by ground acoustic impedance with continuity are investigated by outdoor experiments. In this results, the propagation of road traffic noise is affected by the acoustic impedance properties of the ground surface over which the noise travels, particularly when the receiver position is close to the surface. These results are then used to derive sound pressure level contours for the attenuation with distance of the equivalent energy level received from passing vehicle. The percentage of deep sleep and the number of wakings are studied for continuous traffic noise. The hearing loss and sensitivity threshold shift is investigated by changing the various parameters such as the effects of aging and noise exposure. Evaluation of the response of human to traffic noise is discribed. It is shown that exposure to excessive noise can cause temporary loss of hearing that may become permanent if the exposure is prolonged or intense.

  • PDF