Characteristics of loci on Line-to-Earth Voltage according to Earth Fault in Earthing System for Ships (선박의 접지 시스템에서 지락 고장에 따른 대지 전압 변동 특성)

  • Kim, Jong-Phil;Ryu, Ki-Tak;Lee, Yun-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.487-495
    • /
    • 2021
  • The voltages mainly used in ships are 450 [V], 6.6 [kV], and 11 [kV], and an earthed system is applied to ensure the stability of the power distribution system. In general, low-voltage ships using 450 [V] apply an unearthed system, while high-voltage ships using 6.6 [kV] or 11 [kV] use a high-resistance earthed system. When an earth fault occurs in a ship's power distribution system, the voltage of the healthy phase increases to the line-to-line voltage or higher, which causes an excessive impact on the insulation of the cable. Thus, analyzing this behavior is very important. In this paper, we investigate the characteristics of the line-to-earth voltage variation according to earth faults and a recognition procedure of a faulty phase using the symmetrical coordinate method for a high-resistance earthed system and unearthed system. A mathematical model of the line-to-earth voltage was derived through the symmetric coordinate method, and the ship voltage for simulations was selected as 6.6 [kV] and 450 [V]. A MATLAB simulation proved that this method can determine the highest increase of the line-to-earth voltage, which leads by 120° on the faulty phase, and it accurately judges the faulty phase in both earthed systems.

3상 6.6kV/200A급 유도형 초전도 한류기 개발

  • 고태국
    • Superconductivity and Cryogenics
    • /
    • v.6 no.2
    • /
    • pp.16-20
    • /
    • 2004
  • 전 세계적으로 대규모 정전사태가 발생하고, 국내 전력계통의 경우에도 전력수요가 폭발적으로 증가하여 단락, 지락, 낙뢰 등의 전력사고(고장) 발생 시 기존 차단기의 용량으로는 차단할 수 없는 대형 사고가 발생하고 있다. 이렇게 대규모의 정전 사태의 원인은 병렬 network이다. 우리나라 역시 전기공급을 병렬 network로 운전하고 있어 대규모 정전 사태에 직면할 가능성이 있다.(중략)

  • PDF

Recognition of High Impedance Fault Patterns according to the Chaotic Features (카오스 특징 추출에 의한 고저항 지락사고의 패턴인식)

  • 신승연;공성곤
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1997.10a
    • /
    • pp.311-314
    • /
    • 1997
  • This paper presents recognition of high impedance fault patterns based of chaotic features using the Radial Basis Function Network(RBFN). The chaos attractor is reconstructed from the fault current data for pattern recognition. The RBFN successfully classifies the three kinds of fault pattems and one normal pattem.

  • PDF

전압전로의 지락보호에 관한 기술지침

  • Lee, Ju-Cheol;Lee, Wi-Mun
    • Electric Engineers Magazine
    • /
    • v.266 no.10
    • /
    • pp.28-33
    • /
    • 2004
  • 전기사업법 규정에 의한 기술기준은 전기설비의 안전확보를 위하여 필요한 최소한의 사항을 준수하도록 의무화하고 있다. 또 전기관련기관, 학계, 단체 및 업계의 참여로 작성되는 전기설비의 기술규정은 이러한 기술기준에 필요한 기술적인 사항을 규정함과 동시에 민간자율규정으로서 설계, 시공, 유지, 검사 등에 관한 사항을 구체적이고 알기 쉽게 풀이하여 권고적 사항, 권장적 사항으로 구분하여 규정하고 있다. <중략>

  • PDF

A Study on the Ground Fault Current Distribution by Single Phase-to-Neutral Fault Tests in Power Distribution System (배전계통에서 1선 지락고장 시험에 의한 지락고장전류 분류에 관한 연구)

  • Kim, Kyung-Chul;You, Chang-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.7
    • /
    • pp.37-44
    • /
    • 2013
  • Phase to ground faults are possibly one of the maximum number of faults in power distribution system. During a ground fault the maximum fault current and neutral to ground voltage will appear at the pole nearest to the fault. Distribution lines are consisted of three phase conductors, an overhead ground wire and a multigrounded neutral line. In this paper phase to neutral faults were staged at the specified concrete pole along the distribution line and measured the ground fault current distribution in the ground fault current, three poles nearest to the fault point, overhead ground wire and neutral line. A simplified equivalent circuit model for the distribution system under case study calculated by using MATLAB gives results very close to the ground fault current distribution yielded by field tests.

Problems and Inprovement Method of Grounding System in Electrical Facilities (건축전기설비에 적용되는 접지시스템 문제점과 개선방안)

  • Chung, Young-Ki;Kwak, Hee-Ro;Shin, Hyo-Sub;Chung, Chun-Byoung;Nam, Taik-Joo
    • Electric Engineers Magazine
    • /
    • v.228 no.8
    • /
    • pp.52-57
    • /
    • 2001
  • Presently the Korean grounding system uses TN system, multi-grounding method with IT independent grounding method. Nevertheless TN system can't exist with TT system in the technological terms. If they coexist, it causes ground-fault circuit not to operate, and brings about different electrical potential rise by customer system. It brings about serious problems for safety. This paper aims for improving method of grounding system based on the technical analysis on instances in foreign countries and Korea. Almost standards and construction manner were apt to be internationalized after WTO/TBT agreement was concluded. The internal grounding systems should meet the international criteria and reliability for safety, and be provided with technologically impeccable standards.

  • PDF

The cause analysis of explosion on bushing of 154 kV cable (154 kV급 절연부싱에서의 폭발사고 원인분석)

  • Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Kim, Young-Seok;Choi, Myeong-Il
    • Congress of the korean instutite of fire investigation
    • /
    • 2011.04a
    • /
    • pp.137-160
    • /
    • 2011
  • 본 사고분석을 통해 154 kV 절연부싱에서의 폭발사고에 대한 원인을 규명하였다. 결과적으로, 절연부싱의 사양은 국제표준에 적합하였다. 사고당일 기록된 자료에 의하면 R상과 S상에서 거의 동시에 지락사고가 발생하였으며, 지락지속시간은 약 75 ms로써 사고의 영향을 준 시간은 약 67 ms인 것으로 나타났다. R상은 아크에 의한 탄화 흔적, S상은 아크에 의한 탄화흔적과 외부열에 의한 탄화흔적, T상은 외부열에 의한 탄화흔적, 용융흔적은 R상과 S상의 케이블접속부와 플랜지에서 각각 발생하였다. S상의 절연부싱을 이용하여 탄화패턴 중 아크에 의한 것과 일반 열에 의한 것을 분류하여 연면방전이 발생한 것을 입증하였다. 사고추정 시나리오는 현장조사과정에서 나타난 현상과 목격자 진술, 사고원인 분석자료 등을 토대로 하여 작성되었다. 따라서 사고추정을 통해 분석된 자료는 아크생성단계, 열폭주 단계, 폭발단계, 화재단계로 구성하였다. 사고원인 가능성은 사고의 원인, 형태, 영향을 통해 나타난 연결고리를 검토하여 가능성이 낮은 부분을 배제하는 방식으로 진행되었다. 절연부싱의 사고원인은 표면의 오염물질 부착 가능성이 가장 높았다. 이를 근거로 하여 제조, 시공, 관리적 측면에서의 방지대책을 고려하는 것이 바람직할 것으로 판단된다.

  • PDF

Algorithm of Detecting Ground Fault by Using Insulation Monitoring Device(IMD) in Ungrounded DC System (직류 비접지계통에서 절연저항측정장치(IMD)를 이용한 사고검출 알고리즘)

  • Kim, Ki-Young;Lee, Hu-Dong;Tae, Dong-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.528-535
    • /
    • 2020
  • Recently, the protection coordination method of DC systems has been presented because renewable energy and distributed resources are being installed and operated in distribution systems. On the other hand, it is difficult to detect ground faults because there is no significant difference compared to a steady-state current in ungrounded IT systems, such as DC load networks and urban railways. Therefore, this paper formulates the detection principle of IMD (Insulation Monitoring Device) to use it as a protection coordination device in a DC system. Based on the signal injection method of IMD, which is analyzed by a wavelet transform, this paper presents an algorithm of detecting ground faults in a DC system in a fast and accurate manner. In addition, this paper modeled an IMD and an ungrounded DC system using the PSCAD/EMTDC S/W and performed numerical analysis of a wavelet transform with the Matlab S/W. The simulation results of a ground fault case in an ungrounded DC system showed that the proposed algorithm and modeling are useful and practical tools for detecting a ground fault in a DC system.

전기보안담당자를 위한 자가용 전기설비 사고사례

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • no.6 s.138
    • /
    • pp.89-92
    • /
    • 1988
  • 변압기 1차측에는 과부화 보호를 위한 고압 컷 아웃이 사용되고 여기에 텐션형 퓨즈가 장착되어 있다. 고압 컷 아웃은 전류개폐능력 관계로 300kVA 이하인 변압기에 사용된다. 변압기 운전중은 고압 컷 아웃의 내부점검을 할 수 없기 때문에 통상은 눈으로 외시점검을 하는 것이 일반적이다. 고압 컷 아웃의 사고로는 퓨즈 용단, 애자부의 균열, 오손 등으로 인한 지락이나 접촉 칼날부의 접촉 불량, 본체의 파손 등이 있다. 이러한 사고를 사전에 발견하기는 곤란한 경우가 많은 것 같다. 이러한 사고를 사전에 발견하기는 곤란한 경우가 많은 것 같다. 다음은 고압 컷 아웃이 파손해서 정전된 사례이다.

  • PDF

저항회로의 개폐불꽃에 의한 폭발성 가스의 점화한계에 관한 연구

  • 김재욱;이춘하
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.11a
    • /
    • pp.129-134
    • /
    • 1997
  • 가스폭발사고를 방지하기 위하여 사용하는 방폭형 전기기기중에서 본질안전 방폭구조는 폭발위험장소에 설치되는 전기기기 및 배선의 어떤 부분에서 정상동작 및 사고시(단락, 지락, 단선 등)에 발생하는 불꽃, 아크, 과열이 주위에 있는 폭발성 가스에 점화되지 않도록 한 구조로서, 회로의 전압과 전류를 폭발성 가스의 점화한계 이하가 되도록 구성하는 원리이며 국내외에서 사용이 증가추세에 있다. (중략)