• Title/Summary/Keyword: 지내력

Search Result 112, Processing Time 0.023 seconds

Rule Based System for Selection of Foundation Types of Building Structures (건물의 기초 형식 선정을 위한 규칙 기반 시스템)

  • 김한수;최창근
    • Computational Structural Engineering
    • /
    • v.9 no.1
    • /
    • pp.23-32
    • /
    • 1996
  • A rule based system for foundation design of building structures is developed with CLIPS in this study. The types of foundation and the allowable bearing capacity of supporting soil inferred by the rule based system for selection of foundation type, called SOFTEX, are transferred to a structural design program for building foundation. The allowable bearing capacity is calculated with N values of Standard Penetration Test. The foundation types such as independent spread footing, wall footing, combined footing and mat foundation can be inferred by the foundation merge procedure developed in this study. This procedure is based on the analysis data from the super structure and the estimated bearing capacity. By using this integrated system, structural engineers with less experience in foundation design can design the foundation system for the given superstructure and the site condition with relative ease.

  • PDF

Study on the electrical and mechanical properties of insulating paper (절연지의 기계적 및 전기적 물성에 대한 연구)

  • 엄승욱;김귀열
    • Electrical & Electronic Materials
    • /
    • v.8 no.4
    • /
    • pp.413-417
    • /
    • 1995
  • In order to elucidate the electrical and mechanical properties of insulating paper, it is desirable to study the performances of tensile strength, dielectric constant, dielectric strength. In this work, we constructed the characteristics depending on change of fabrication condition, and these specimens were manufactured by hot press method. As a result, tensile strength was about 75MPa and breakdown was above 5 kV/mm at the minimum value.

  • PDF

Hysteresis Behavior of Semirigid CFT Column-to-Beam Connections with a Double Web-Angle (더블 웨브앵글 반강접 CFT 기둥-보 접합부의 이력거동)

  • Lee, Sung Ju;Kim, Joo Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.1
    • /
    • pp.15-24
    • /
    • 2013
  • This paper presents the results from a systematic finite element study on the bending moment resisting capacity of double web-angle connection for a CFT(concrete filled tube) composite frame subjected to cyclic loading. The three-dimensional nonlinear finite element models are constructed to investigate the rotational stiffness, bending moment capacity, and failure modes of the partially restrained composite CFT connections. A wide scope of additional structural behaviors explain the different influences of the double web-angle connections parameters, such as the different thickness of connection angles and the gage distances of high strength steel connection bar. The moment-rotation angle relationships obtained statically from the finite element analysis are compared with those from Richard's theoretical equation.

An Experimental Study on Ultimate Behavior of Thin-walled Carbon Steel Bolted Connections with Varying Plate Thickness and End Distance (평판두께와 연단거리를 변수로 갖는 박판탄소강 볼트접합부의 종국거동에 관한 실험적 연구)

  • Lee, Yong Taeg;Kim, Tae Soo;Jeong, Ha Young;Kim, Seung Hun
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.5
    • /
    • pp.527-536
    • /
    • 2009
  • The purpose of this experimental study was to investigate the block shear fracture behavior and curling effect on a single shear-bolted connection in thin-walled carbon steel fabricated with four bolts. The specimens that fail by block shear were planned to have a constant dimension of the edge distance perpendicular to the loading direction, bolt diameter, pitch, and gage. The main variables of the specimens were plate thickness and end distance parallel to the loading direction. A monotonic tensile test was carried out for the bolted connections, and the ultimate behaviors, such as the fracture shape, ultimate strength, and curling, were compared with those that had been predicted using the current design specifications. The conditions of curling occurrence in terms of plate thickness and end distance were also investigated, and the strength reduction due to curling was considered.

Monotonic and Hysteresis Behavior of Semirigid CFT Column-to-Beam Connections with a Top-Seat Angle (상·하부 ㄱ형강 반강접 CFT 기둥-보 접합부의 단조 및 이력거동)

  • Lee, Sung Ju;Kim, Joo Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.3
    • /
    • pp.191-204
    • /
    • 2014
  • In this paper a systematic numerical analysis is performed to obtain the bending moment resisting capacity of a top and seat angle connection, which is a type of partially restrained connection, for a CFT composite frame subjected to cyclic loading. This partially restrained composite CFT connections are fabricated using high strength steel connection bar. The three-dimensional nonlinear finite element models are constructed to investigate the rotational stiffness, bending moment capacity, and failure modes. A wide scope of additional structural behaviors explain the different influences of the top and seat angle connection's parameters, such as the different thickness of connection angles and the gage distances of the high strength steel bar. The moment-rotation angle relationships obtained from the finite element analysis are compared with those from Richard's theoretical equation.

A New Methodology for Seismic Capacity Evaluation of Low-rise R/C Buildings (비선형요구내력스펙트럼을 이용한 저층 R/C 건물의 내진성능 평가법)

  • Lee, Kang Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.3
    • /
    • pp.106-115
    • /
    • 2011
  • This study proposed a new methodology for seismic capacity evaluation of low-rise reinforced concrete (RC) buildings based on non-linear required spectrum. In order to verify the reliability of the proposed method, relationships between results obtained using the proposed method and the non-linear dynamic analyses were investigated. Compared with the seismic protection index (Es=0.6) defined in the Japanese Standard, the applicability of the method was also estimated. Research results indicate that the method proposed in this study compares reasonably well with the detailed evaluation methods. Using the seismic evaluation method developed in this study, the seismic capacity category and earthquake damage degree of low-rise RC buildings corresponding to a specific earthquake level can be effectively estimated.

The Case Study of Rock Treatment Method for the Fractured Rock Foundation of Underground Roadway Structure (기반암의 파쇄대 특성을 고려한 지하차도 기초 보강사례)

  • Yoon, Ji-Nam;Yang, Sung-Don;Lee, Geun-Ha;Park, Sa-Won;Jung, Hun-Chul
    • Tunnel and Underground Space
    • /
    • v.18 no.2
    • /
    • pp.125-133
    • /
    • 2008
  • The rock treatment methods for improving bearing capacity and reducing settlement of the underground roadway structure foundation on fractured rock was studied in this paper. Also, effective reinforcement scheme was evaluated by numerical analysis for the application to the practical construction. Various in-situ and laboratory tests were executed systematically at Yeongi-goon, Ohoongchungnam-do, Korea, for the purpose of defining the physical and mechanical properties of rock. Consequently the effective treatment methods insuring the bearing capacity of fractured rock were proposed. In addition, the adequate reinforcing depth of the comparatives measure, such as double rod, triple rod injection methods and micropile, were investigated from the case study. Finally, the most effective construction scheme with the consideration of safety and economical aspects were proposed by using numerical analysis(Plaxis ver. 8.2).

A Study on Thermal Deterioration Characteristics of Insulator in Oil Filled Distribution Transformers (배전용 변압기 절연물의 열화특성에 관한 연구)

  • Lee, Won-Kyu;Cho, Si-Hyung;Choi, Myeong-Ho;Shin, Dong-Hwi
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.533-535
    • /
    • 2005
  • 본 연구에서는 열적 스트레스에서 충간 절연지가 받는 열화현상을 규명하고 절연지의 열화가 절연유 열화에 미치는 영향에 대해서 고찰하였다. 변압기 절연물의 열화는 온도와 시간에 좌우되므로 이를 모의화 할수 있는 시험장치를 제작하고 보다 정확한 모의시험이 가능하도록 절연유 열화와 절연지 열화시험을 구분하여 실험하였다. 실험결과 절연유가 열적 스트레스를 받는 경우 열화시간에 따라 절연내력이 감소되었고 유전손실은 증가되었다. 유전손실은 열화시간과 온도상승에 크게 좌우되었다. 절연지가 절연유 내에서 열적 스트레스를 받을 경우에는 열화시간에 따라 인장강도는 급격히 감소되었고 유전손실과 유전율은 증가됨을 알 수 있었다. 또한 유전율의 변화는 절연유와의 절연지의 계면에서 전압 스트레스와 불균일하게 되어 수명단축의 원인이 될 수 있음을 보여주었다.

  • PDF

Programming of Beam/Column Analytical Process for Composite Wall Panels (냉간성형강 스터드 합성벽 패널의 보/기둥 해석기법의 전산화)

  • Lee, Young Ki
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.1 s.74
    • /
    • pp.45-52
    • /
    • 2005
  • The object of this study was a cold-formed steel wall stud panel sheathed by gypsum boards. In the beam-analysis, the panel was treated as a simple beam with a uniform lateral loading. The deflections were calculated by considering the primary factors that reduced the stiffness of the panel. In the column-analysis, the panel was treated as a bearing wall with an axial load. By using an energy method, nominal axial strength could be evaluated by considering both flexural buckling and torsional-flexural buckling. All calculations were programmed and compared with the results of the experiment. In the beam-analysis, experimental deflections were close to theoretical deflections. In the column-analysis, the experimental values were also close to theoretical values in axial strength.

Influence of the Combustion Flame on the Dielectric Strength of an Air Gap due to Fire Occurrence (화재발생에 따른 연소화염이 공기의 절연내력에 미치는 영항)

  • 김인식;하장호
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.30-38
    • /
    • 2002
  • Occurring fire or burning bushes beneath overhead power lines have caused system disturbances in many countries. In this study, various tests in the simulated condition of power lines were conducted so as to investigate the reduction in insulation strength caused by combustion flame. Characteristics of the ac and dc flashover voltages in the vertical needle-plane, sphere-plane and rod-plane electrode system were investigated when the combustion flames were present near the high-voltage electrode. As the results of an experimental investigation, It was found that the average reduction characteristics of flashover voltages with the sphere-plane system, in comparison with the no-flames case, were about 1/3 times when the ac voltages were applied.