Comparative Study on the Performance of Correlations of the Enthalpy of Vaporization for Pure Substance Refrigerants (순수물질 냉매에 대한 증발 엔탈피 상관식의 성능비교 연구)

  • 박경근
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.704-709
    • /
    • 2003
  • A few commonly used correlation equations of the enthalpy of vaporization are reviewed and a new three-parameter correlation equation is proposed. Performance of the proposed equation is examined using the data listed in the ASHRAE table for 22 pure substance refrigerants. The new equation yields an average absolute deviation of 0.14% for 22 refrigerants, which is better than those of other equations, such as Xiang (0.18%), Major-Svoboda-Pick (0.18%), and Somayajulu equation (0.23%).

The Cooling Effect Using Pad & Fan in Greenhouse (패드엔팬을 이용한 온실냉방효과)

  • 장유섭;김동억;이동현
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.223-229
    • /
    • 2002
  • 패드엔팬을 이용하여 물 공급량, 팬 회전속도의 변화에 따른 온실 냉방효과 시험한 결과를 요약하면 다음과 같다. 가. 패드에 흐르는 물 공급량별로 일중 11:00-16:00경에 물 공급량이 분당 60$\ell$이상 공급하면 8.0~9.5$^{\circ}C$의 온도차를 낼 수 있으며, 팬을 1170rpm으로 회전시킬 경우 6.0~9.$0^{\circ}C$의 온도차를 낼 수 있었다. 나. 온실과 팬출구 공기의 온도차는 일중 14:30~16:00 경에 60$\ell$이상의 물을 패드에 공급하는 경우 6.0~7.8$^{\circ}C$ 온도 강하 효과가 있고 팬을 1170rpm으로 회전시킬 경우에는 외기온 28$^{\circ}C$일 때 3$0^{\circ}C$이하로 온도를 강하시킬 수 있었다. 다. 패드에 흘리는 물의량을 60 $\ell$/min 이상을 공급하여 주면 30분당 20~28$\ell$의 물을 증발시킬 수 있다. 배출팬 회전속도가 1170rpm일 경우에 30분당 20~30$\ell$의 물을 증발시키는 것으로 나타났다. 라. 본시험에 사용된 패드엔팬의 흡.배기의 엔탈피변화는 8:30이전에는 흡기가 배기보다 온도가 낮아 엔탈피가 양(+)의 값을 나타났고, 8:30 이후에는 흡기가 배기 보다 온도가 높아 -2.0~-4.OkJ/kg의 엔탈피 차만큼 냉각효과가 있었으며, 냉방효율을 65~80% 수준으로 나타났다. 마. 본시험결과로 패드엔팬의 냉기 공급방식만 개선된다면 이동식인 박스형 패드엔팬도 냉방장치로 사용 가능할 것으로 판단된다.

  • PDF

A new correlation of the enthalpy of vaporization for pure refrigerants (순수물질 냉매에 대한 증발엔탈피의 새로운 상관식)

  • 박경근
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.449-455
    • /
    • 1998
  • A header' is the device that makes uniform flow distribution in all branches from header of heat exchangers, pipe burner or chemical equipments. In this study, experimental tests have been performed in order to investigate the flow distribution characteristics in a straight header and tapered header which have 6 and 11 glass pipe branches. The experimental equipment consists of a water circulation system where the fluid velocity in each glass pipe is measured by Ar-ion LDV system. From the experiments and the theoretical equation, it could be recommended that tapered header should be determined so that its internal velocities inside the header become uniform according to taper of the header and number of attached branches for uniform flow distribution in energy systems.

  • PDF

A Proposal of a Correlation of the Enthalpy of Vaporization for Pure Substances and Performance Comparison of Correlations (순수물질에 대한 증발엔탈피 상관식의 제안 및 성능비교)

  • Lee, Kyoung-Youl;Park, Kyoung-Kuhn
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1185-1191
    • /
    • 2005
  • Published correlation equations of the enthalpy of vaporization are reviewed and a new four-parameter correlation equation is proposed. Performance of the proposed equation is examined using the ASHRAE data for 22 pure substance refrigerants as reference data. The new equation yields an average absolute deviation of $0.05\%$, which is smaller than those of published equations, such as equations of Guermouche-Vergnaund $(0.08\%)$, Aerebrot $(0.13\%)$, Radoz-Lydersen $(0.08\%)$, and Somayajulu $(0.08\%)$. The three adjustable parameters of the modified correlation are optimized and reported for 22 substances. The equation proposed in this work is valid over the entire temperature range where data points exist.

Performance Analysis of the Soft Ice-cream Maker Having Two Evaporators Operating at Different Temperatures (두개의 증발기가 장착된 소프트 아이스크림 제조기의 성능 해석)

  • Kim, Jeong-Sik;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.517-522
    • /
    • 2013
  • Small size ice-cream maker has two evaporators having different evaporating temperatures of $4^{\circ}C$ and $-8^{\circ}C$. In such case, ice-cream maker system design becomes complicated because multiple capillary tubes affects one another. In this study, performance analysis was conducted for the soft ice-cream maker having two evaporators operating at different temperatures. The compressor was analyzed using efficiency models, the capillary tube was modeled assuming one-dimensional flow, the condenser and the evaporators were modeld based on UA-LMTD method. The refrigeration cycle simulation program was developed applying the enthalpy, pressure and mass balance on each component. Comparison of the test data with the simulated results for R404A revealed that evaporator temperatures of refrigerator and freezer agreed within $3^{\circ}C$.

Temperature characteristics of condenser and evaporator of Air-conditioner applying variable capacity compressor under cooling condition (가변용량 압축기를 적용한 에어컨의 냉방운전 시 응축 및 증발온도 특성)

  • Kwon, Young-Chul;Chun, Chong-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1325-1331
    • /
    • 2007
  • In order to investigate the cooling capacity of an air-conditioner applying a variable capacity compressor and the temperature characteristics on a condenser and an evaporator, the experiment on the operation characteristics of the air-conditioner was performed along a compressor operation ratio and an indoor/outdoor temperatures, under a cooling operation mode. The system characteristics were measured by the psychrometric calorimeter. The cooling capacity increased with decreasing the outdoor temperature and increasing the indoor temperature. Also, it increased with increasing the compressor operation ratio. The temperature of the condenser was more sensitive for the variation of the outdoor temperature and the temperature of the evaporator was more sensitive for the variation of the indoor temperature. The operation characteristics of the cycle used in this present were also analyzed by a pressure-enthalpy chart.

  • PDF

Study on the velocity of gadolinium atomic vapor produced by electron beam heating (전자빔 가열로 발생시킨 Gd 원자증기의 속도에 관한 연구)

  • 정의창;권덕희;고광훈;김택수
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.4
    • /
    • pp.228-234
    • /
    • 2003
  • The velocity of gadolinium(Gd) atomic vapor vaporized by an electron beam was measured by a microbalance. The velocity of about 900 ㎧ was obtained at an evaporation surface temperature of 2400-2500 K. The measured value was approximately 100 ㎧ faster than the maximum velocity of an ideal monatomic gas in an adiabatic expansion. This phenomenon can be explained that the internal energy of Gd atoms populated in higher excited levels at the high temperature should be convened to kinetic energy during adiabatic expansion. The calculated velocity agrees with the measured one when 100 excited energy levels are included in an enthalpy term for the velocity calculation. The characteristics of vapor flow as a function of heated surface temperature are also reported.

An analysis on the characteristics of superheater organization of ORC system for marine waste heat recovery system(WHRS) (선박폐열회수(WHRS) ORC 시스템의 과열기 구성에 따른 특성 해석)

  • Kim, Jong-Kwon;Kim, You-Taek;Kang, Ho-Keun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.8-14
    • /
    • 2014
  • This research designed Waste Heat Recovery System(WHRS) generation system of 250kW whose working fluid is R-245fa and studied on cycle characteristics by superheater organization. It simulated two conditions; series connection and parallel connection between superheater and evaporator. In simulation of series connection of superheater and evaporator, output of 4.7% could be improved because of the increase of enthalpy by overheating of working fluid. When setting 250kW for target output, cycle flux could be reduced by 4.1%. When setting 250kW as a target output of cycle In parallel connection simulation of superheater and evaporator, cycle flux was reduced as flux of heat source fluid for superheater was increased. So, the maximum 7.9% of working fluid pump's electric power was reduced and there was no big change in cycle efficiency and net efficiency by flux ratio.

Steady-State Performance Analysis of Air Conditioner with Multi-Indoor Units (복수 실내기를 가지는 에어컨의 정상상태 성능해석)

  • Hur, Hyun;Lee, Jin Wook;Jung, Eui Guk;Kim, Byung Soon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.11
    • /
    • pp.705-715
    • /
    • 2016
  • In this study, the cycle performance of an air conditioner with multi-indoor units is analyzed and simulated. The cycle performance could be predicted through the integration of mathematical formulation for these devices. The condenser pressure is obtained by an iteration process to match the mass flow rates of the compressor and the expansion valve and the evaporator pressure is determined by an iteration process, in which the suction super heat is tracing the targeted super heat. The required software was developed by system programming. the software algorithm is extended to predict the cycle performance of an air conditioner system with multi-indoor units, and then the numerical results are compared with experimental results. This mathematical model is validated from the result of experiments conducted on 8.3kW air conditioner. The errors in capacity, electronic power, and COP are found to be within 10% in general.

A Study on Performance Characteristics of a Dehumidifier with Multi-layer Type Heat Exchangers Varying Frontal Air Velocity (다층형 열교환기를 이용한 제습기의 전면 풍속 변화에 따른 성능 특성에 관한 연구)

  • Ku, Hak-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2323-2327
    • /
    • 2010
  • The experimental apparatus consists of dehumidifier with multi-layer type heat exchangers to remove the moisture from automatic equipments, semiconductors, and manufacturing processes under the low temperature environment, and chemical production lines which are likely to take moisture. The major components of this system are four evaporators with different fin pitch, two compressors, two condensers and an expansion valve. In this study, the performance characteristics of dehumidifier is analyzed by the variations of frontal air velocity in the first heat exchanger(evaporator). The cooling capacity of each heat exchanger is acquired by the enthalpy calculating from measuring point of temperature and relative humidity of the first heat exchanger from 1.0m/s to 4.0m/s with increasing interval 0.5m/s, and the front air velocity. As a result, it is found that cooling capacity of the first heat exchanger showed the best cooling capacity when its frontal air velocity is 2.0 m/s.