• Title/Summary/Keyword: 증발온도

Search Result 810, Processing Time 0.025 seconds

The Relationship between Affinity of Membrane and Optimum Operation Conditions in the Pervaporation of Aqueous Ethanol (에탄올 수용액의 투과증발에 있어서 막의 친화성과 최적 조업조건의 관계)

  • 전종기;명완재;임선기
    • Membrane Journal
    • /
    • v.1 no.1
    • /
    • pp.34-43
    • /
    • 1991
  • The relationships between affinity of membranes and optimum operation conditions were investigated in the pervaporation of water(1)/ethanol(2) mixture through cellulose acetate(CA) membranes having more affinity to water and silicone rubber(SR) membranes having more affinity to ethanol. CA and SR membranes were prepared and amount of sorption, sorption selectivity, pervaporation separation factor and pervaporation rate in both of membranes were determined and compared. The effects of downstream pressure were analyzed using Thompson diagram and the sorption and pervaporation characteristics with composition of feed and operation temperature were examined in terms of affinity, activity coefficient, plasticizing effect and activation energy of individual species. In the separation of water through CA membranes, high performance of both pervaporation separation factor (water to ethanol, $[\alpha^2_1]_{PV}$) and pervaporation rate was obtained in the conditions of low downstream pressure, middle range of feed concentration and high temperature. In the separation of ethanol through SR membranes, pervaporation separation factor(ethanol to water, $[\alpha^2_1]_{PV}$) increased with downstream pressure and decreased with concentration of ethanol in feed and operation temperature, while pervaporation rate showed opposite trends to those of ($[\alpha^2_1]_{PV}$).

  • PDF

CIGS 박막 태양전지를 위한 $(In,Ga)_2Se_3$ 전구체 제작 및 분석

  • Jo, Dae-Hyeong;Jeong, Yong-Deok;Park, Rae-Man;Han, Won-Seok;Lee, Gyu-Seok;O, Su-Yeong;Kim, Je-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.285-285
    • /
    • 2010
  • $Cu(In,Ga)Se_2$ (CIGS) 박막 태양전지 제조에는 동시증발법 (co-evaporation)으로 Cu, In, Ga, Se 각 원소의 증발을 세 단계로 제어하여 CIGS 박막을 증착하는 3-stage 방법이 널리 이용된다[1]. 3-stage 중 1st-stage에서는 In, Ga, Se 원소 만을 증발시켜 $(In,Ga)_2Se_3$ 전구체 (precursor) 박막을 성장시킨다. 고효율의 CIGS 태양전지를 위해서는 $(In,Ga)_2Se_3$ 전구체 증착의 공정 변수와 이에 따른 박막 특성의 이해가 중요하다. 본 연구에서는 Mo 박막이 증착된 소다석회유리 (soda lime glass) 기판에 동시증발장비를 이용하여 280 380 의 기판 온도에서 In, Ga, Se 물질을 증발시켜 $(In,Ga)_2Se_3$/Mo/glass 시료를 제작하였으며 XRD, SEM, EDS 등의 방법을 이용하여 특성을 분석하였다. XRD 분석 결과 기판 온도 $280{\sim}330^{\circ}C$에서는 $(In,Ga)_2Se_3$ 박막의 (006), (300) 피크가 관찰되었으며, 기판 온도가 증가할수록 (006) 피크 세기는 감소하였고 (300) 피크 세기는 증가하였다. $380^{\circ}C$에서는 (110)을 포함한 다수의 피크가 관찰되었다. 그레인 (grain) 크기는 기판 온도가 증가할수록 커지며 Ga/(In+Ga) 조성비는 기판 온도에 따라 일정함을 각각 SEM과 EDS 측정을 통해 알 수 있었다. $(In,Ga)_2Se_3$ 전구체의 (300) 배향은 CIGS 박막의 (220/204) 배향을 촉진하고[2], 이것은 높은 광전변환효율에 기여하는 것으로 알려져 있다. 때문에 $(In,Ga)_2Se_3$의 (300) 피크의 세기가 가장 큰 조건인 $330^{\circ}C$를 1st-stage 증착 온도로 하여 3-stage CIGS 태양전지 공정을 수행하였으며, $MgF_2$/Al/Ni/ITO/i-ZnO/CdS/CIGS/Mo/glass 구조의 셀에서 광전변환효율 16.96%를 얻었다.

  • PDF

Performance Analysis of the Soft Ice-cream Maker Having Two Evaporators Operating at Different Temperatures (두개의 증발기가 장착된 소프트 아이스크림 제조기의 성능 해석)

  • Kim, Jeong-Sik;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.517-522
    • /
    • 2013
  • Small size ice-cream maker has two evaporators having different evaporating temperatures of $4^{\circ}C$ and $-8^{\circ}C$. In such case, ice-cream maker system design becomes complicated because multiple capillary tubes affects one another. In this study, performance analysis was conducted for the soft ice-cream maker having two evaporators operating at different temperatures. The compressor was analyzed using efficiency models, the capillary tube was modeled assuming one-dimensional flow, the condenser and the evaporators were modeld based on UA-LMTD method. The refrigeration cycle simulation program was developed applying the enthalpy, pressure and mass balance on each component. Comparison of the test data with the simulated results for R404A revealed that evaporator temperatures of refrigerator and freezer agreed within $3^{\circ}C$.

Effect of Greenhouse Cooling Method on the Growth and Yield of the Tomato cv. Momotaro in Warm Season (고온기 유리온실의 냉방방법이 토마토 생육 및 수량에 미치는 영향)

  • 최영하;이재한;박동금;권준국;엄영철
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1999.11a
    • /
    • pp.164-168
    • /
    • 1999
  • 온실은 동절기 난방을 주목적으로 설비되어 년중 작물재배 시는 하절기 온실내부 온도가 필요이상으로 상승하여 실내온도가 35-4$0^{\circ}C$ 정도로 올라가는데 이러한 상태에서의 온도는 많은 작물의 생육적온을 벗어난 온도로서 고온장해를 나타낸다. 이 같은 문제점을 해결하기 위해 몇 가지 냉방방법이 알려져 있는데 에어컨 등과 같은 냉방장치를 이용한 기계적 냉각방식과 수분증발을 통한 증발식 냉각방식으로 대별되며 이중 기계적인 냉방방식은 설비나 유지관리 면에서 비용이 많이 들어 비경제적이고, 증발냉각 방식중에서도 Fan and Pad 법이 가장 효과가 좋은 것으로 알려져 있으나 이역시 설치 및 유지비가 많이 들고, vep의 탈부착이 어려워 고정시켜놓을 경우 동계 광투과에 방해가 되는 등의 문제가 많다. (중략)

  • PDF

Distribution of Relative Evapotranspiration Availability using Satellite Data in Daegu Metropolitan (위성 자료를 이용한 대구광역시의 상대적 증발산 효율 분포)

  • Kim, Hae-Dong;Im, Jin-Wook;Lee, Soon-Hwan
    • Journal of the Korean earth science society
    • /
    • v.27 no.6
    • /
    • pp.677-686
    • /
    • 2006
  • Surface evapotranspiration is one of the most important factors to determine the surface energy budget, and its estimation is strongly related with the accuracy of weather forecasting. Surface evapotranspiration over Daegu Metropolitan was estimated using high resolution LANDSAT TM data. The estimation of surface evapotranspiration is based on the relationship between surface radiative temperature and vegetation index provided by a TM sensor. The distribution of NDVI (Normalized Difference of Vegetation Index) corresponds well with that of land-used in Deagu Metropolitan. The temperature of several part of downtown in Deagu metropolitan is lower in comparison with the averaged radiative temperature. This is caused by the high evapotranspiration from dense vegetation like DooRyu Park in Deagu Metropolitan. But, weak evapotranspiration availability is distinguished over the central part of downtown and the difference of evapotranspiration availability on industrial complexes and residential area is also clear.

Development of Cascade Refrigeration System Using R744 and R404A - Analysis on Performance Characteristics - (R744-R404A용 캐스케이드 냉동시스템 개발에 관한 연구(1) - 성능 특성에 관한 분석 -)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.182-188
    • /
    • 2011
  • In this paper, analysis on the performance characteristics of R744-R404A cascade refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree, compressor efficiency, and condensing and evaporating temperature in R404A high- and R744 low-temperature cycle, respectively. The main results were summarized as follows : It was observed that the highest COP of the system is achieved by higher superheating degree in R744 cycle than that in R404A cycle. The COP of the system increased by giving the subcooling degree in both cycles. The COP of the cascade system is the highest value when the system is operated at an optimum evaporation temperature.

A Study on Evaporation Characteristics of Ethanolamine for Removal COD and N (COD 및 N 제거를 위한 에탄올아민의 증발 특성 연구)

  • Jeong, Eun-Sun;Kim, Jong-Young;Ku, Hee-Kwon;Rhee, In-Hyoung;Park, Byung-Gi
    • Proceedings of the KAIS Fall Conference
    • /
    • 2008.11a
    • /
    • pp.423-426
    • /
    • 2008
  • 에탄올아민(ETA: Ethanolamine)은 탄소, 질소, 산소로 이루어진 유기화합물로 각종 산업에서 널리 사용되는 물질이다. 이러한 ETA는 상온에서는 휘발성을 띠지만 산 염기의 평형상수가 9.4 이므로 그 이하에서는 양이온 형태로 존재한다. 또한 수중에 존재할 경우 COD 및 T-N을 유발하는 물질이므로 이를 제거해야 한다. 따라서 본 연구에서는 수중에 존재하는 ETA를 제거하기 위해 온도, pH, 내부압력에 따른 ETA 증발 특성을 조사하였다. ETA증발 초기에는 끓는점의 차이로 인하여 물이 먼저 증발하며 일정시간 경과 후 농축된 ETA가 급격히 증발하였다. 내부압력이 낮아짐에 따른 ETA 수용액의 끓는점은 낮아졌으며 내부압력이 160mmHg이하일 때 가열온도에 영향을 받지 않고 ETA는 전량 증발하였다. 대기압 상태에서 ETA의 증발량은 pH에 영향을 받지만 진공상태에서는 ETA의 부분압이 낮아져 그 영향력은 매우 적었다.

  • PDF

지하수 및 토양의 온도 관측 자료를 이용한 함양량 산정 기법

  • 구민호;김형수
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.83-87
    • /
    • 2001
  • 토양이나 천부 지하수 온도의 장기 관측 자료를 이용하여 함양량 또는 증발산량을 산정하는 온도추적자법의 원리를 소개하였으며, 국가 지하수 관측망의 장기 관측 자료에 본 방법을 적용하여 관측소 주변에서의 수직적인 물의 흐름(flux)을 추정하였다. 20개 충적층 관정의 수온 관측 자료를 분석한 결과, 15개 지역에서는 증발산에 의한 상향(upward) 흐름이, 5개 지역에서는 지하수 함양에 의한 하향(downward) 흐름이 우세하게 발생하는 것으로 나타났다. 본 방법은 수직적인 물의 흐름을 시간 독립적인 정류 상태로 가정하므로 우기에 지하수 함양이 주로 발생하는 국내의 수리지질학적 조건에 잘 부합하지 않지만 함양 지역을 판단하는 방법으로 유용하게 이용될 수 있다.

  • PDF

Experimental Study on Reducing Effect for Surface Temperature of Recycled Synthetic-Resin Permeable Block (재생 합성수지 투수블록의 표면온도 저감효과에 관한 실험적 연구)

  • Lee, Chul-Hee;Lee, Arum;Shin, Eun-Chul;Ryu, Byung-Hyun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.1
    • /
    • pp.79-89
    • /
    • 2019
  • The field measurement and laboratory experiment were conducted to investigate the effect of reducing the surface temperature of the functional aspect of the heat island phenomenon of the permeable block which is made the recycled synthetic resin rather than the existing concrete permeable block. Field measurement was taken for 3 days in consideration of dry condition and wet condition and laboratory experiment was divided into dry condition, rainfall simulating condition, and wetting condition. The variations of temperature and the evaporation rate of water moisture content after experiment were confirmed. As a result of field measurement, it is confirmed that the surface temperature decreases due to the difference in albedo of the pore block surface rather than the cooling effect due to the latent heat of vaporization. The evaporation of moisture in a dry state where drought persisted or a certain level of moisture was not maintained in the surface layer. As a result of laboratory experiment, resin permeable block gives higher surface temperature when it is dry condition than concrete permeable block, but the evaporation of water in the pore is kept constant by capillary force in rainfall simulation condition, and higher temperature reduction rate. As a result of measuring the evaporation rate after laboratory experiment, it is confirmed that the effect of reducing temperature is increased as the evaporation rate of water is higher. Based on these results, correlation formula for evaporation rate and temperature reduction rate is derived.