• Title/Summary/Keyword: 증발액적

Search Result 118, Processing Time 0.046 seconds

Evaporation Characteristics of Paired Sessile Droplets on a Heated Substrate (가열된 표면에 고착된 한 쌍의 액적 증발 특성)

  • Hyung Ju Lee;Won Yeong Hwang;Jing Hao Jin;Chang Kyoung Choi;Seong Hyuk Lee
    • Journal of ILASS-Korea
    • /
    • v.28 no.3
    • /
    • pp.113-118
    • /
    • 2023
  • This study investigates the evaporation characteristics of paired sessile droplets on a heated substrate. In particular, the evaporation time and contact line behaviors were analyzed based on the droplet-to-droplet distance and substrate temperature. The contact line behavior and volume variations were visualized using the shadowgraph method. It was observed that the contact diameter and contact angle exhibited similar behavior for both single and paired droplets regardless of the droplet-to-droplet distance and substrate temperature. The paired droplets demonstrated a longer evaporation time than the single droplet due to the vapor accumulation between the droplets. Furthermore, the scaled lifetime, defined as the ratio of evaporation time between paired and single droplets, increased as the droplet-to-droplet distance decreased and decreased as the substrate temperature increased, attributed natural convection.

Numerical Study of Evaporation and Ignition of in-line Array Liquid Droplets (액적 배열의 증발과 착화에 관한 수치해석적 연구)

  • 김충익;송기훈
    • Fire Science and Engineering
    • /
    • v.13 no.1
    • /
    • pp.37-47
    • /
    • 1999
  • The spreading fire of very small floating particles after they are ignited is fast and t therefore dangerous. The research on this area has been limited to experiments and global simulations which treat them as dusts or gaseous fuel with certain concentration well m mixed with air. This research attempted micro-scale analysis of ignition of those particles modeling them as liquid droplets. For the beginning, the in-line array of fuel droplets is modeled by two-dimensional, unsteady conservation equations for mass, momentum, energy and species transport in the gas phase and an unsteady energy equation in the liquid phase. They are solved numerically in a generalized non-orthogonal coordinate. The single step chemical reaction with reaction rate controlled by Arrhenius’ law is assumed to a assess chemical reaction numerically. The calculated results show the variation of temperature and the concentration profile with time during evaporation and ignition process. Surrounding oxygen starts to mix with evaporating fuel vapor from the droplet. When the ignition condition is met, the exothermic reactions of the premixed gas initiate a and burn intensely. The maximum temperature position gradually approaches the droplet surface and maximum temperature increases rapidly following the ignition. The fuel and oxygen concentration distributions have minimum points near the peak temperature position. Therefore the moment of ignition seems to have a premixed-flame aspect. After this very short transient period minimum points are observed in the oxygen and fuel d distributions and the diffusion flame is established. The distance between droplets is an important parameter. Starting from far-away apart, when the distance between droplets decreases, the ignition-delay time decreases meaning faster ignition. When they are close and after the ignition, the maximum temperature moves away from the center line of the in-line array. It means that the oxygen at the center line is consumed rapidly and further supply is blocked by the flame. The study helped the understanding of the ignition of d droplet array and opened the possibility of further research.

  • PDF

Study of Behavior Characteristics of Emulsified Fuels with Evaporative Field (증발장에서 에멀젼연료의 거동특성에 관한 연구)

  • Yeom, Jeong Kuk;Yoon, Jeong Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.237-243
    • /
    • 2015
  • In this study, the effects of the mixing ratio of emulsified fuel on the droplet evaporation and spray behavior characteristics were analyzed. A surfactant comprising span 80 and tween 80 mixed at a 9:1 ratio was used for the emulsified fuel. The fuel and surfactant were mixed at a ratio of 3:1 for the emulsified fuel. In addition, considering the mixing ratio of the surfactant, the mixing ratio of $H_2O_2$ in the emulsified fuel was set as EF (emulsified fuel)0, EF2, EF12, EF22, EF32, and EF42. To observe the evaporation characteristics, droplets of the emulsified fuel were dropped on a heating plate and observed using scattered light and a Schlieren system. In addition, to analyze the effect of the $H_2O_2$ mixing ratio, the behavior characteristics of the evaporative free spray were investigated in the mixing ratio range of EF0 to EF22 using a constant volume chamber with heaters. Consequentially, it was found that in the case of EF22, the free spray development of the emulsified fuel was faster than that of EF0 (diesel only) because of the promotion of the evaporation due to the phase change in the peroxide contained in the emulsion fuel.

The study of a fire fighting characteristic by a Single Evaporating Droplet in the case of a fire of military enclosure space (군사용 밀폐공간내의 화재시 단일 증발액적에 의한 방재특성 연구)

  • 이진호;방창훈;김정수
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.207-217
    • /
    • 2000
  • A fire fighting characteristic by a single evaporating droplet in the case of a fire of military enclosure space was studied experimentally. Transient cooling of solid surface by water droplet evaporation has been investigated through controlled experiments using a heated brass cylinder. Quantitative predictions of droplet evaporation time and in-depth transient temperature distribution in solid have been made. The particular interest was in the removal of thermal energy from the heated cylinder by evaporative cooling. A $10{\mu}1$ single droplet is deposited on a horizontal brass surface with initial temperatures in the range of $90^{\circ}C{\sim}130^{\circ}C.$ The results can be summarized as follows; Evaporating droplet was divided into three different configuration. Evaporation time was predicted as a function of initial surface temperature ($t_c=492.62-6.89T_{s0}+0.0248T_{s0}^2).$ The contact temperature was predicted as a function of initial surface temperature( $T_{i}$=0.94 $T_{s0}$+1.4), The parameter ${\beta}_o$ was predicted as a function of initial surface temperature( ${\beta}_0$ : 0.O0312 $T_{s0}+0.932$)>)>)

  • PDF

Experimental Studies on Electrohydrodynamic Atomization of CIGS Nanoparticle Precursor (CIGS 나노입자를 포함한 전구체의 전기수력학적 분무에 관한 실험적 연구)

  • Woo, Jihoon;Yoon, Sukgoo;Kim, Hoyoumg
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.41.1-41.1
    • /
    • 2010
  • 전기수력학적 분무를 이용한 액적 미립화 기술은 나노사이즈의 액적 형성, 쿨롱 반발력에 의한 균일한 액적 형성, 그리고 향상된 액적 타겟팅을 가능하게 한다. 따라서 이를 이용하여 매우 균일한 박막 코팅이 가능하다. 이러한 점에 힘입어 현재 진공 공정으로 제작되고 있는 CIGS태양전지의 광흡수층을 비진공 공정중 하나인 전기수력학적 미립화를 이용하여 실험하였다. Ethanol-based 의 CIGS나노 입자를 포함하는 콜로이드 상태의 전구체를 이용하여 적절히 가열된 몰리브덴 배면 전극위에 적용하였다. 미립화한 액적은 접지된 몰리브덴 층에 부착되는 즉시 증발하여 CIGS입자를 남긴다. 여기서 가장 중요하게 다루어야 할 조건은 기판의 온도, 인가 전압, 전구체의 유량이다. 분사 모드는 Cone-jet을 적용하였으며 5~15kV의 인가 전압에서 1ml/hr내외의 유량을 공급하여 3분 이내에 적절한 광흡수층 두께인 1마이크론 내외에 도달할 수 있다. 이와같은 조건으로 형성된 박막층에 관한 SEM image를 통해 다른 비진공 코팅 방식과 비교하였다.

  • PDF

Numerical Analysis for Spray Combustion Considering Droplet Heating (액적 가열을 고려한 분무 연소의 수치 해석)

  • Sung Hyunggun;Jeong Daekwon;Lee Sangmyeong;Roh Taeseong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.208-211
    • /
    • 2005
  • In order to provide a useful data of combustion chamber design, a numerical analysis for spray combustion of fuel and oxidizer in combustion chamber has been conducted. As a spray model, the DSF model and the Euler-Lagrange scheme have been used. The change of droplet temperature has been calculated considering droplet heating. The coupling effects between and the gas phase the droplets, and between the gas phase and the evaporated vapor have been calculated using the PSIC model.

  • PDF

Basic study on the Behavior Characteristics of Liquid-phase Spray with Phase Change (상변화를 동반한 액상분무의 거동 특성에 관한 기초 연구)

  • Yeom, J.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.2
    • /
    • pp.5-11
    • /
    • 2010
  • 분사연료의 혼합기형성과정 최적화를 통한 연소제어 기술은 디젤기관의 기관운전 및 배기특성을 향상시키기 위하여 매우 중요하다. 또한 분무의 혼합기형성 최적화를 위해서는 분사된 연료와 주위기체와의 혼합과정에 영향을 미치는 분무내부의 유동특성에 대한 연구는 필수 불가결하다. 따라서 본 연구에서는 고온 고압의 증발장에서 분무의 액상 거동에 주목하고, 그 거동특성을 통하여 증발디젤분무의 혼합기형성을 해석한다. 비정상 증발분무의 중심축에 레이저 시트광을 입사한 후, 액상분무 액적의 Mie 산란광에 의한 2차원 화상을 획득하여 증발분무 액상의 속도분포 및 와도(vorticity) 등을 구하였다. 분무의 속도분포 및 와도는 2차원 화상에 PIV법을 적용하여 계산하였다. 그림 1에 본 연구에서 구한 속도분포의 일례를 보인다. 본 연구의 결과로 상변화를 동반하는 비정상 증발장에서 구한 분무액상의 거동 특성은 상변화가 일어나지 않는 비증발장에 있어서의 분무거동특성과 유사함을 확인하였다.

Development of the Real-time Concentration Measurement Method for Evaporating Binary Mixture Droplet using Surface Plasmon Resonance Imaging (표면플라즈몬공명 가시화 장치를 이용한 증발하는 이종혼합물 액적의 실시간 농도 가시화 기법 개발)

  • Jeong, Chan Ho;Lee, Hyung Ju;Choi, Chang Kyoung;Lee, Hyoungsoon;Lee, Seong Hyuk
    • Journal of ILASS-Korea
    • /
    • v.26 no.4
    • /
    • pp.212-218
    • /
    • 2021
  • The present study aims to develop the Surface Plasmon Resonance (SPR) imaging system facilitating the real-time measurement of the concentration of evaporating binary mixture droplet (BMD). We introduce the theoretical background of the SPR imaging technique and its methodology for concentration measurement. The SPR imaging system established in the present study consists of a LED light source, a polarizer, a lens, and a band pass filter for the collimated light of a 589 nm wavelength, and a CCD camera. Based on the Fresnel multiple-layer reflection theory, SPR imaging can capture the change of refractive index of evaporating BMD. For example, the present study exhibits the visualization process of ethylene glycol (EG)-water (W) BMD and measures real-time concentration change. Since the water component is more volatile than the ethylene glycol component, the refractive index of EG-W BMD varies with its mixture composition during BMD evaporation. We successfully measured the ethylene glycol concentration within the evaporating BMD by using SPR imaging.