• Title/Summary/Keyword: 증발성능

Search Result 459, Processing Time 0.032 seconds

Development of Cascade Refrigeration System Using R744 and R404A - Analysis on Performance Characteristics - (R744-R404A용 캐스케이드 냉동시스템 개발에 관한 연구(1) - 성능 특성에 관한 분석 -)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.182-188
    • /
    • 2011
  • In this paper, analysis on the performance characteristics of R744-R404A cascade refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree, compressor efficiency, and condensing and evaporating temperature in R404A high- and R744 low-temperature cycle, respectively. The main results were summarized as follows : It was observed that the highest COP of the system is achieved by higher superheating degree in R744 cycle than that in R404A cycle. The COP of the system increased by giving the subcooling degree in both cycles. The COP of the cascade system is the highest value when the system is operated at an optimum evaporation temperature.

Characteristics of the Air Heat Exchanger for the Improvement of the Heat Pump COP (열펌프 성능향상을 위한 공기 열교환기 특성)

  • 노정근;송현갑;박용규
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.151-157
    • /
    • 2002
  • 화석에너지에 대한 경제적 부담과 환경오염문제를 줄이기 위하여 열펌프의 성능계수향상을 위하여 냉온 공기열교환기(HEEVA)를 고안하였고, 이 열교환기의 열특성과 성능계수향상에 미치는 영향을 분석하기 위하여 냉.난방 실험을 수행하였다. HEEVA에 의한 찬 공기와 더운 공기의 온도변화, 전열량 및 냉온 공기열교환기 효율, 총열전달계수등을 측정분석하였고, 냉난방시 외기온에 따른 열펌프의 성능계수, 소비전력, 응축기.증발기 출구 공기토출 온도 변화를 측정 분석함으로서 다음과 같은 결과를 얻을 수 있었다. 1. 외기온이 -4~11$^{\circ}C$로 변할 때 열펌프의 난방과정에서 HEEVA 찬공기 입출구 온도차는 4.5$^{\circ}C$에서 9.$0^{\circ}C$로 증가하였으며, HEEVA에 의한 영향으로 2~6$^{\circ}C$상승된 공기가 증발기 입구로 유입되어 냉매증발을 촉진하였다. 2. 실온이 4~22$^{\circ}C$일 때 HEEVA 더운공기 입출구 온도차는 3$^{\circ}C$에서 7$^{\circ}C$로 증가하였으며, 응축기에 유입되는 공기온도를 3~8$^{\circ}C$낮게 함으로서 압축기 소모전력을 감소시켜 COP 상승 효과를 나타냈다. 3. 외기온과 실온변화에 따라 풍량 346m$^3$/hr의 찬 공기가 받은 열량과 풍량 747m$^3$/hr의 더운 공기가 준 열량간의 차는 50~150kcal/hr로 나타났으며, 더운 공기가 준열량과 찬 공기가 받은 열량의 비가 83~98% 이었으므로 HEEVA의 열 교환율은 91% 을 보였다. 4. 총합열전달계수는 이론값이 실험 값보다 1~3W/m$^2$K 크게 나타났으며, 이 결과는 두 값 사이에 10% 내.외의 편차로서 Nusselt수를 구하기 위한 Petukhov상관식의 자체오차 15%에 비해 크지 않은 오차범주에 속하며, 이론상의 총합열전달계수 유도식의 타당성을 입증한 것이라 하겠다. 5. HEEVA를 작동함으로서 난방시 COP가 HEEVA를 작동하지 않았을 경우보다 0.3~0.5 향상된 것으로 나타났다. 이것은 HEEVA가 겨울철 난방에 효율을 높일수 있는 것으로 판단된다.

  • PDF

암모니아 냉동시스템의 성능향상 방법

  • 정은수
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.29 no.1
    • /
    • pp.26-33
    • /
    • 2000
  • 최신의 암모니아의 냉동시스템들은 효율이 더 높고 더 안전하게 제작될 수 있다. 또한, 현재의 표준인 고충전 펌프순환 시스템들을 펌프를 사용하지 않고 증발기에 냉매를 과공급하도록 설계된 저충전 시스템들로 대체함으로써 기존의 암모니아 시스템들을 성능과 안전성을 향상시킬 수 있다.

  • PDF

Calculation of non-condensable gases released in a seawater evaporating process (해수 증발과정에서의 기체방출량 계산)

  • Jeong, Kwang-Woon;Chung, Hanshik;Jeong, Hyomin;Choi, Soon-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.182-190
    • /
    • 2017
  • All liquids contain a small amount of gaseous components and the amount of gases dissolved in a liquid is in accordance with Henry's Law. In a multi-stage thermal-type seawater desalination plant, as the supplied seawater undergoes variations in temperature and pressure in each evaporator, the gases dissolved in the seawater are discharged from the liquid. The discharged gases are carbon dioxide, nitrogen, oxygen, and argon, and these emitted gases are non-condensable. From the viewpoint of convective heat transfer, the evaluation of non-condensable gas released during a vacuum evaporation process is a very important design factor because the non-condensable gases degrade the performance of the cooler. Furthermore, in a thermal-type seawater desalination plant, most evaporators operate under vacuum, which maintained through vacuum system such as a steam ejector or a vacuum pump. Therefore, for the proper design of a vacuum system, estimating the non-condensable gases released from seawater is highly crucial. In the study, non-condensable gases released in a thermal-type seawater desalination plant were calculated quantitatively. The calculation results showed that the NCG releasing rate decreased as the stage comes getting a downstream and it was proportional to the freshwater production rate.

Development of Pervaporation System Simulator (투과증발 시스템 모사기 개발)

  • 장재화;유제강;안승호;이규현;류경옥
    • Membrane Journal
    • /
    • v.7 no.1
    • /
    • pp.31-38
    • /
    • 1997
  • A simulator has been developed in order to simulate and to be used to design the pervaporation system for separating organic/water mixtures. This simulator is composed of simulation engine, which includes a modeling of pervaporation system and the numerical analysis, and Graphical User Interface(GUI), which enables us to operate the simulator more easily in the Windows environment. The structure and operation of simulator were clearly presented by demonstrating the full-scale ethanol dehydration process. The performance of simulator turned out to be fairly good through comparing the simulation results with the experimental data of ethanol dehydration pilot tests.

  • PDF

투과증발 분리법에 의한 CMC/PVA blend막의 물/유기용제 혼합액의 분리특성

  • 홍영기;배기서;이정민
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1993.10a
    • /
    • pp.52-53
    • /
    • 1993
  • 투과증발 분리를 위하여 여러가지 막 소재와 공정을 개발하기 위한 노력이 다방면에서 이루어지고 있으며, 이에 관한 자료도 많이 제시되고 있으나 고분자 분리막의 개발은 아직도 미흡한 상태이다. 한편 투과증발 분리는 공정자체는 매우 간단하면서도 분리막의 투과성능에 따라 분리효율이 달라지기 때문에 여러종류의 막의 개발이 필요하다. 따라서 본 연구에서는 물/유기용제 혼합액에서 물을 분리하기 위하여 친수성이 강한 두 고분자 재료인 poly(vinyl alcohol)(PVA)와 carboxymehtylcellulose(CMC)를 브랜드하여 목적하는 분리기능을 갖는 새로운 막을 제조하여, 물/유기용제, 혼합액의 분리특성을 브랜드비와 온도 및 농도 그리고 분리시간에 따라 각각 검토하였다.

  • PDF

Effects of performance analysis of a desiccant cooling system with a direct evaporative cooler in the regeneration process (재생 입구 직접증발냉각기 적용이 제습냉방시스템 성능에 미치는 영향)

  • Dash, Ulziiutas;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.633-638
    • /
    • 2009
  • In this study the performance analysis and cooling capacity of desiccant cooling system incorporating regenerative cooler and direct evaporative cooler in the regeneration air inlet were investigated on the condition of low regeneration temperature and time rotation 180s and area ratio of regeneration to dehumidification section 0.7. The cooling capacity and COP are evaluated at various effectiveness values of the direct evaporative cooler or the regenerative evaporative cooler. As either of effectiveness of the regenerative and direct evaporative coolers of desiccant cooling system increases, both the cooling capacity and COP increase, but effectiveness value of regenerative cooler gives the opposite effect on the system performance. It is found that effectiveness of regenerative cooler less than 0.7 shows the optimum cooling capacity.

  • PDF

A Study on Characteristics of Heat Transfer for a Rotating Heat Pipe with a Trigonal Cross Section (삼각 단면을 갖는 회전 열파이프의 열전달 특성에 관한 연구)

  • 이진성;김철주;김윤제;최영준;홍성은
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1997.10a
    • /
    • pp.114-121
    • /
    • 1997
  • 회전 열파이프의 열전달 성능은 액막 두께 및 증발부로 귀환되는 응축 액막 유동율에 의해 결정된다. 그 동안 응축액 유동율을 촉진시키기 위하여 용기 내벽에 groove, 테이퍼 및 나선형 코일을 삽입하여 유동율을 높이는 방법들이 연구되었다. 본 연구도 회전 열파이프의 내부 관벽 구조에 관한 것으로써 삼각 단면을 갖는 회전 열파이프의 열전달 특성을 파악하고자 하였다. 삼각 단면을 갖는 회전 열파이프는 고속 회전 영역에서 모서리 부분으로 액막이 집중되어 관 내벽에 형성되는 액막 두께를 줄일 수 있으나 증발부에서 국부적인 과열이 발생되어 불안정한 작동 상태를 나타내었다. 따라서 본 연구에서는 개선방안으로 증발부에 부분적으로 원형관을 접합하였으며, 그 결과 dry-out의 억제와 함께 삼각 유동 단면에 의한 액막 두께 감소 효과를 볼 수 있었다. 회전체 발열부 냉각에 적용시키기 위해서는 앞으로 최적의 기하학적 형상에 따른 충전율 및 액막에서의 열전달에 대한 정량적인 해석 연구가 필요할 것으로 생각된다.

  • PDF

CMC / PVA, PAA 복합막의 투과증발 분리특성

  • 홍영기;배기서;이정민
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1994.10a
    • /
    • pp.30-31
    • /
    • 1994
  • 분리막을 이용한 분리기술은 일반증류법에 의한 분리 또는 정제에 어려운 액체 혼합물을 분리하는데 적용될 수 있고 또한 미래 산업적인 중요성 때문에 최근 유용한 정제법으로 주목을 끌고 있다. 한편, 투과증발법에 의한 액체혼합물의 분리는 공정자체는 매우 간단하면서도 분리막의 투과성능에 따라 분리효율이 달라지기 때문에 이에 적합한 고분자 분리막의 개발은 아직도 많은 연구과제로 남아있는 상태이다. 따라서 본 연구에서는 증류법이나 기타방법에 의하여 회수된 저 농도의 유기수 용액으로부터 물을 보다 효율적으로 분리하여 고농도의 특정순수 유기용제를 얻으려는데 목적을 두고 보다 높은 물 선택성과 투과율을 갖는 새로운 복합막을 개발하기 위해 고흡수성 고분자재료인 CMC와 PVA 그리고 PAA를 소재로 하여 목적하는 분리기능을 갖는 새로운 복합막을 제조하여 실용가능성을 검토하기 위하여 투과증발 분리실험을 하였다.

  • PDF