• Title/Summary/Keyword: 증발성능

Search Result 459, Processing Time 0.02 seconds

Performance analysis for load control of R744(carbon dioxide) transcritical refrigeration system using hot gas by-pass valve (핫가스 바이패스 밸브를 이용한 R744용 초임계 냉동사이클의 부하제어에 대한 성능 분석)

  • Roh, Geun-Sang;Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2189-2194
    • /
    • 2009
  • The automatic hot gas by-pass technique is applied to control the capacity of refrigeration and air-conditioning system when operating at part load. In the scheme, the hot gas from the compressor is extracted and injected into the outlet of an evaporator through a hot gas by-pass valve. Thus, In this paper, the hot gas by-pass scheme for CO2 is discussed and analyzed on the basis of mass and energy conservation law. A comparative study of the schemes is performed in terms of the coefficiency of performance (COP) and cooling capacity. The operating parameters considered in this study include compressor efficiency, superheating degree, outlet temperature of gas cooler and evaporating temperature in the R744 vapor compression cycle. The main results were summarized as follows : the superheating degree, outlet temperature and evaporating temperature of R744 vapor compression refrigeration system have an effect on the cooling capacity and COP of this system. With a thorough grasp of these effect, it is necessary to design the compression refrigeration cycle using R744.

Analysis on Cooling Effects of the Vertical Type Geothermal Heat Pump System Installed in a Greenhouse for Raising Seedling (수직형 지열히트펌프 시스템의 육묘 온실 냉방 효과 분석)

  • Kang, Youn Ku;Ryou, Young Sun;Kim, Jong Goo;Kim, Young Hwa;Jang, Jae Kyoung
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.19-25
    • /
    • 2013
  • In this study, the cooling experiment was carried out in $1,650m^2$ area of the seedling greenhouse from June 6, 2011 to september 18, 2011 with the vertical type geothermal heat pump system of 350 kW scale (175 kW ${\times}$ 2 units) installed in the greenhouse, cooling effects were analyzed and we tried to find more effective operation methods of the geothermal heat pump system. In case of one unit heat pump (175 kW) operation, when evaporator inlet water temperature changed from $13.0^{\circ}C$ to $15.5^{\circ}C$, cooling COP of the system was in 1.1~1.8 range and in case of two unit heat pump (350 kW) operation, when evaporator inlet water temperature changed from 13.0 to 15.5, cooling COP of the system was in 2.0~2.7 range. The accumulated cooling heat quantity of June, July, August and September was 14,718.6, 26,765.1, 28,437.2 and 10,065.0 kWh, respectively.

Study on the Performance Characteristics of the Thermosyphon Used for the Vehicle Operated at Low Temperature Conditions (저온작동 조건에서 자동차용 써모사이폰의 성능특성에 관한 연구)

  • Lim, Taek-Kyu;Lee, Ho-Seong;Won, Jong-Phil;Cho, Chung-Won;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.2
    • /
    • pp.510-515
    • /
    • 2012
  • The objective of this study is to investigate low temperature performance characteristics of the thermosyphon with/without wick. Thermosyphons using water as the working fluid are tested with variations of wick, charge amount of the working fluid, outdoor temperature, and heat load for the evaporator section at a low temperature. As a result, the heat transfer of thermosyphon was optimized at the charge amount of 40% and increased with the rise of the outdoor temperatures.

Development of the Dryer with a Heat Source of Carbon Nanofibers (탄소나노섬유를 열원으로 적용한 세탁물 건조기의 개발)

  • Lee, Jung-Hwan;Won, Sang-Yeon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.23 no.3
    • /
    • pp.25-34
    • /
    • 2018
  • This paper presents a heating source of carbon nanofibers for the efficiency and the drying performance of laundry dryer, and focuses on the applicability-evaluation of its source. To design the proposed heating module, experiments were conducted in terms of surface temperature and surface temperature distribution characteristics of carbon nanofiber lamps. The surface temperature of the lamps increased linearly with increment of a current to flow a lamp and revealing the increasing pattern as the length of the ramps is shorter. The proposed heating source was evaluated based on drying efficiency, moisture evaporation rate at laundry, and internal temperature of a drum during drying process. The drying efficiency satisfied a 45% which is specified in KS C 9319. The moisture evaporation rate and the internal temperature of the drum were respectively 98.88% and $61.1^{\circ}C$, which are similar to that of S's company dryer. From the evaluation and actual drying test results, the proposed carbon nanofiber lamp heating module is considered to be applicable as a heat source for laundry dryer in terms of drying efficiency and drying performance. it is possible to obtain a heat source at a high temperature, an excellent calorific value, an improvement in drying performance, and an effect of sterilizing laundry due to the emission of far-infrared rays. In addition to the applicability, the difference of the drying efficiency between the dryers was analyzed in detail based on the power consumption of the heat sources.

원심압축기에서 물분사 압축과정에 대한 이론적 해석

  • Kang, Jeong-Seek;Cha, Bong-Jun;Yang, Soo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.18-24
    • /
    • 2005
  • Wet compression means the injection of water droplets into the compressor of gas turbines. This method decreases the compression work and increases the turbine output by decreasing the compressor exit temperature through the evaporation of water droplets inside the compressor. This paper provides thermodynamic and aerodynamic analysis on wet compression in a centrifugal compressor for a microturbine. The meanline performance analysis of centrifugal compressor is coupled with the thermodynamic equation of wet compression to get the meanline performance of wet compression. The most influencing parameter in the analysis is the evaporative rate of water droplets. It is found that the impeller exit flow temperature and compression work decreases as the evaporative rate increases. And the exit flow angle decreases as the evaporative rate increases.

  • PDF

Pool Boiling Performance of Enhanced Tubes for a Flooded Evaporator (만액식 증발기용 성형가공관의 풀비등 성능)

  • Kim, Nae-Hyun;Kim, Tae-Hyung;Park, Woon-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.1
    • /
    • pp.124-131
    • /
    • 2000
  • In this study, pool boiling performance of Turbo/B-type metal-formed tubes was investigated. Tubes with three different cavity gap width(0.04 mm, 0.07 mm, 0.1 mm) were manufactured and tested using R-11, R-123 and R-134a. Tests were conducted at two different saturation temperatures $4.4^{\circ}C$ and $26.7^{\circ}C.$ Heat flux was varied from 10 kW/m2 to 50 kW/m2. It was found that optimum gap width varied for different refrigerants. For low-pressure refrigerants such as R-11 or R-123, optimum gap width was 0.07 mm. For high-pressure refrigerant R-134a, however, the optimum value was 0.1 mm. Compared with the heat transfer performance of the smooth tube, the metal-formed tubes enhanced the heat transfer coefficients significantly - 6.5 times for R-11, 6.0 times for R-123 and 5.0 times for R-134a (at $4.4^{\circ}C$ saturation temperature and 40 kW/m2 heat flux), which are comparable with the performance of foreign products. The heat transfer coefficients of R-134a were larger than those of R-11 or R-123, and they increased as the saturation temperature increased.

Performance Simulation of a Ventilation System Adopting a Regenerative Evaporative Cooler (재생증발식 냉방기를 이용한 환기 냉방시스템의 성능해석)

  • Chang, Y.S.;Lee, D.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.8-15
    • /
    • 2011
  • Cooling load reduction was analysed of a ventilation system adopting a regenerative evaporative cooler. The regenerative evaporative cooler is a kind of indirect evaporative cooler which cools the air down to its inlet dewpoint temperature in principle without change in the humidity ratio. The regenerative evaporative cooler was found able to cool the ventilation air to $18{\sim}21^{\circ}C$ when the outdoor condition ranges $25{\sim}35^{\circ}C$ and 0.01~0.02 kg/kg. When the outdoor humidity ratio is lower than 0.018 kg/kg, the regenerative evaporative cooler was found to provide cooling performance enough to compensate the ventilation load completely and to supply additional cooling as well. Energy simulation during the summer was carried out for a typical office building with the ventilation system using the regenerative evaporative cooler. The results showed that the seasonal cooling load can be reduced by about 40% by applying the regenerative evaporative cooler as a ventilation conditioner. The reduction was found to increase as the outdoor temperature increases and the outdoor humidity ratio decreases.

Change of the Warm Water Temperature for the Development of Smart Healthecare Bathing System (지능형 헬스케어 욕조시스템 개발을 위한 온수 온도변화)

  • Kim, Gi-Beom
    • Korean Chemical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.270-276
    • /
    • 2006
  • In this study, heat loss through free surface of water contained in bathtub due to conduction and evaporation has been analyzed. As a result of this study, a relational equation has been derived based on the basic theory of heat transfer to evaluate the performance of bath tubes. The derived equation was rational and quantitative. The major heat loss was found to be due to evaporation. Moreover, it has been found out that the speed of heat loss depends more on the humidity of the bathroom than the temperature of water contained in the bathtub. So, it is best to maintain the temperature of bathtub water to be between 41 to $45^{\circ}C$ and the humidity of bathroom to be 95%.

A Study on Performance Improvement of a Heat Pump Dryer with an Extra Evaporator Outside (보조 외부 증발기를 이용한 히트펌프 건조기 성능 향상에 관한 연구)

  • Lee, Young-Lim;Park, Sang-Jun;Hwang, Il-Sun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.10
    • /
    • pp.711-717
    • /
    • 2012
  • A heat pump dryer for the frozen food needs to preheat the air to a certain temperature where condensation can efficiently occur. In this study, an analysis of a heat pump dryer performance with operating conditions, an analysis of supplying heat with internal and external evaporators and a warm-up experiment with the evaporators have been performed. The results showed that the external evaporator can significantly accelerate the warm-up time of the dryer, so that it can reduce power consumption greatly. The use of the external evaporator is more efficient for higher ambient temperature. In addition, it was found that COP decreases and the range of evaporating pressure for the evaporator becomes narrower as the condensing temperature of the condenser increases.

The Performance Comparison of $CO_2$ Gascooler and Evaporator with Heat Exchanger Type (열교환기 형태에 따른 이산화탄소용 가스쿨러와 증발기의 성능비교)

  • Bae, Kyung-Jin;Cho, Hong-Hyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.6 no.2
    • /
    • pp.15-22
    • /
    • 2010
  • The natural refrigerants have used into HVAC equipments because the CFCs and HFCs have some environmental problems like high ODP and GWP. The carbon dioxide has small effect on the environmental problem but also good thermodynamics properties. In this study, the simulation study on the performance and characteristics of a $CO_2$ gascooler and evaporator using a fin-tube and microchannel heat exchanger has been conducted. Besides, the comparison of performance with operating condition was carried out in order to apply to the $CO_2$ heat pump system. As a result, the front sizes of a gascooler and evaporator using a microchannel were decreased by 63% and 58%, respectively, compared to those using a fin-tube. The performance of the fin-tube gascooler and evaporator were more responsive to the variation of operating conditions compared to that of microchannel. The pressure drop of a fin-tube heat exchanger was higher than that of a microchannel one.