• Title/Summary/Keyword: 즉시 교정력

Search Result 10, Processing Time 0.022 seconds

The effect of loading time on the stability of mini-implant (교정력 부하시기에 따른 교정용 미니 임플란트의 안정성)

  • Lee, Seung-Yeon;Cha, Jung-Yul;Yoon, Tae-Min;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.38 no.3
    • /
    • pp.149-158
    • /
    • 2008
  • Objective: The purpose of this study was to investigate the stability of mini-implants in relation to loading time. Methods: A total of 48 mini-implants (ORLUS, Ortholution, Korea) were placed into the buccal alveolar bone of the mandible in 8 male beagle dogs. Orthodontic force (200-250gm) was applied immediately for the immediate loading group while force application was delayed for 3 weeks in the delayed loading group. For the subsequent loading periods (3, 6, 12 weeks), BIC (bone implant contact) and BV/TV (bone volume/total volume) and mobility test were carried out. Results: The immediate loading group showed no changes in BIC from 3 to 12 weeks, while the delayed loading group showed a significant increase in BIC between 3 and 12 weeks (p<0.05). The BV/TO of the delayed loading group significantly increased from 6 to 12 weeks of loading (p<0.05), while the BV/TV of the immediate loading group decreased from 3 to 12 weeks of loading. However, there was no significant difference in BV/TV between experimental groups. The mobility of the immediate loading group was not significantly different from that of the delayed loading group after 12 weeks of loading (p<0.05). Conclusions: These results showed that immediate loading does not have a negative effect on the stability of mini-implants compared to the early loading method in both the clinical and histomorphometric point of view.

Influence of immediate loading on the removal torque value of mini-screws (교정력의 즉시 부하가 미니스크류의 제거 회전력에 미치는 영향의 평가)

  • Sun, Seung-Bum;Kang, Yoon-Goo;Kim, Seung-Hun;Mo, Sung-Seo;Kook, Yoon-Ah
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.400-406
    • /
    • 2007
  • The purpose of this experimental study was to evaluate the effect of immediate orthodontic loading on the stability at the bone-implant interface of titanium miniscrews in a rabbit model. Methods: Forty titanium miniscrews (1.6 mm diameter, 8 mm length) were inserted in the tibiae of 10 rabbits. Twenty test group miniscrews were subjected to continuous orthodontic forces of 200g immediately after implantation for a period of 6 weeks. The remaining 20 control group miniscrews were left unloaded for the same follow-up interval. Removal torque values were recorded using a digital torque gauge. An independent t-test was performed. Results: All the miniscrews were stable, and exhibited no mobility or displacement throughout the experimental period. Histologically, miniscrews were well-integrated into bone. No statistically significant differences in removal torque data were found between the loaded test and the unloaded control groups. Conclusions: These findings suggest that titanium miniscrews can be used as anchoring units for orthodontic tooth movement immediately after insertion.

An effect of immediate orthodontic force on palatal endosseous appliance$(C-Palatal\;Plate^{TM})$ in beagle Dog (성견 구개부 골내고정원 장치에 가해진 즉시 교정력이 주위조직에 미치는 영향)

  • Kim, Su-Jung;Lee, Young-Jun;Chug, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.33 no.2 s.97
    • /
    • pp.91-102
    • /
    • 2003
  • This study was performed to investigate the effect of immediate orthodontic force on soft md hard tissues surrounding C-Palatal $Plate^{TM}$ in beagle Dog. Immediately after this appliance was implanted on the midpalate of 4 adult beagle Dogs, 400gm continuous orthodontic force was applied. Experimental animals were euthanized at 8weeks, 18weeks, and 22weeks (including post-removal healing time of 4weeks), and a control animal was euthanized at 8weeks after implantation without orthodontic force application. The appliance and the surrounding tissue were studied radiographically, macroscopically, and histologically. The results were as follows: 1. The lateral radiographs taken after euthanasia showed very slight displacement of the vortical plate in the experimental animals, compared with the control animal. Mobility test of all animals confirmed primary stability without any increase of mobility during experimental period. 2. No pathologic changes were found in the healing condition of covering soft tissue and bone-screw interface in experimental animals as well as a control animal. 3. Osseointegration was achieved in the bone-screw interface in 8weeks after implantation and the amount of osseointegration increased in 18weeks. There was little difference of osseointegration between the compression side and the tension side. 4. In the marginal bone area, slight bone apposition and resorption were found regardless of compression and tension side, while there was no change in the control animal. 5. Both 8week-animal and 18week-animal showed the new bone apposition along the surface of screws which were perforated into the nasal cavity, while the control animal showed no change. 6. After 4weeks of plate removal, the covering epithelium was repaired intactly, while the connective tissue showed loose and irregular rearrangement and the connective tissue capsule remained. The C-Palatal $Plate^{TM}$ manifested sufficient anchorage capacity in the context of histological study as well as clinical outcomes, when immediate orthodontic force was applied after implantation.

THE INITIAL TISSUE CHANGE TO THE IMMEDIATE ORTHODONTIC FORCE FOLLOWING BUCCAL HORIZONTAL SUBAPICAL OSTEOTOMY OF MAXILLA (상악골 협측 수평 골절단술 직후 교정력에 의한 초기 치아주위 조직반응)

  • Hong, Kwang-Jin;Ahn, Byoung-Keun
    • The korean journal of orthodontics
    • /
    • v.25 no.1 s.48
    • /
    • pp.101-110
    • /
    • 1995
  • The purpose of this study was to observe the tissue response to the orthodontic force applied immediately after buccal horizontal subapical osteotomy of maxilla. Five mongrel cats weighing about 2.5 Kg were used for this experiment. The left upper canine and premolar of each cat served as a experimental side and the right ones as a control side. On the experimental side, a 100gm orthodontic force was applied between the upper canine and premolar immediately after the osteotomy. On the control side, the same orthodontic force was applied without the osteotomy. After 7days, the experimental animals were sacrificed. The results were as follows: 1. In the pressure zones of the experimental group, significant increase of osteoclasts and direct resolution along the alveolar bone surface was observed as compared with those of the control group. 2. In the pressure 2ones of the experimental group, a less extensive hyalinized zone was observed than those of the control group. 3. In the pressure zones of both group, no root resorption was found. 4. Tn the tension zones of the experimental group, new bone deposition increased along the alveolar bone surface as compared with those of the control group. In conclusion, the results suggest the possibility that early orthodontic treatment after orthognathic surgery may have some benefits if the stability of the repositioned segment at surgery is secured.

  • PDF

The effect of early loading on the direct bone-to-implant surface contact of the orthodontic osseointegrated titanium implant (교정력이 골유착성 티타니움 임프란트의 초기 고정에 미치는 영향에 관한 실험적 연구)

  • Chung, Kyu-Rhim;Lee, Sung-Ja
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.173-185
    • /
    • 2001
  • The orthodontic osseointegrated titanium implant, a kind of intraoral skeletal anchorage can be an alternative to tooth-borne anchorage, in case that the conventional tooth-borne anchorage is not available or the anchorage is critical. This study was conducted to elucidate the effect of early loading on the osseointegration of the orthodontic titanium implant and the healing process of the impaired bone at the site of implant after removing it. In two adult beagle dogs24 osseointegrated titanium implants were inserted into the alveolar bone, with 12 implants placed in each dog. In dog1, 6 out of 12 implants were loaded with 200-300gm of force immediately after placing, and the remaining 6 implants were not loaded for 4weeks. In dog2, all 12 implants had healing period of 4weeks, and then were loaded with 200-300gm of force for another 4weeks. Following an observation period of 4 and 8 weeks, the animals were sacrificed. Then the implants and the surrounding bone of dog1 and dog2 were removed, respectively. Undecalcified sections along the long axis of implant were made and the degree of osseointegration was examined under the light microscope. The results were as follows. 1. In the histologic features of tissues around implants anchored in dog1, there was no difference between immediately loaded implants and unloaded implants. Immature woven bone was ingrowing into the thread spaces from the original compacta and in direct contact with the implant surface in part. 2. The premature loading just after 4weeks healing period did not halt the progress of the osseointegration between bone and implant surface. The woven bone around the implants was maturing into the lamellar bone which resembled the structure of the original compacta at the end of 8weeks observation period. 3. Most implants with the inflammed surrounding mucosa were lost or mobile. The mobile implants were encapsulated by fibrous connective tissue which separated the implant surface from the bone. 4. The impaired bone at the site of the implant failed to anchor was showing recovery without inflammatory reaction 2weeks after removing, with the immaure woven bone lined by active osteoblasts and osteoid. Based on the results of this study, the integration of this orthodontic implant seemed to be impaired by the inflammation of the tissue surrounding the Implant rather than by early loading on implant, and increased with time lapsed after placing the implant. The use of implant described in this report can be recommended as an orthodontic anchorage unit immediately after insertion under the careful control of orthodontic force applied and plaque.

  • PDF

The experimental study of early loading on the Miniplate in the beagle dog (성견의 하악골에 식립된 Miniplate에 가한 조기 부하의 영향에 관한 실험적 연구)

  • Chung, Yong-Koo;Lee, Young-Jun;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.33 no.4 s.99
    • /
    • pp.307-317
    • /
    • 2003
  • Conventional osseointegrated titanium implants have many limitations; large size, limited location for placement of the implant, severity of the surgery, discomfort of initial healing, difficulty of oral hygiene and uncontrollable force direction. Recently titanium miniscrew and miniplate have been used for an alternative to conventional dental implant. But in relation to miniplate, miniscrew has disadvantages in that more potential inflammation, light orthodontic force application and limited orthodontic application. This study was conducted to evaluate the effectiveness of miniplate by observing the reactions of peri-implant tissues to early orthodontic and orthopedic loading of titanium miniplate. In four adult beagle dogs 10 miniplates were inserted into the alveolar bone using 20 osseointegrated titanium screws. 4 miniplates were placed in two dogs(dogA, B) and 6 miniplates in two dogs(dogC, D). In dogA, B miniplates were loaded with 200gm of force immediately after placement for 15 weeks. In dogc, D, miniplates were loaded with 400gm of force immediately after placement for 8 weeks. Miniplates of dogA were removed, dogA was healed for 4 weeks, and the area which was removed of miniscrew was examined. Following an observation period, the miniplates including miniscrews and the surrounding bone of dogB and dogC, D were removed, respectively. Undecalcified section along the long axis of miniscrews were made and the degree of osseointegration was examined under the light microscope. The results were as follows. 1. In the histologic features there was direct contact between bone and miniscrew in all groups except one, dogC control group. The loaded miniscrew demonstrated only a slight increase of the osseous proximaty when compared with unloaded miniscrew 2. There was no significant difference of the osseointegration of Peri-miniscrew surface between dogB and dogC, D. But dogB showed slightly more increased bone apposition than dogC, D 3. The gingiva overlapping the miniplate and miniscrew showed no inflammatory sign in clinical and histological aspects. 4. The impaled hard and soft tissues at the area which was removed of miniscrews showed good healing without inflammatory reaction. 5. The mobility showed slight increase in un-loaded miniplate but that was insignificant. Based on the results of this study, miniplate(C-tube) can be used as a firm osseous orthodontic and orthopedic anchorage unit immediately after insertion.

The validation of Periotest values for the evaluation of orthodontic mini-implants' stability (즉시 부하 교정용 미니임플랜트의 안정성 평가를 위한 Periotest$^{(R)}$의 유효성)

  • Cha, Jung-Yul;Yu, Hyung-Seog;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.40 no.3
    • /
    • pp.167-175
    • /
    • 2010
  • Objective: The aim of this study was to validate the Periotest values for the prediction of orthodontic mini-implants' stability. Methods: Sixty orthodontic mini-implants (7.0 mm $\times$ $\emptyset1.45$ mm; ACR, Biomaterials Korea, Seoul, Korea) were inserted into the buccal alveolar bone of 5 twelve month-old beagle dogs. Insertion torque (IT) and Periotest values (PTV) were measured at the installation procedure, and removal torque (RT) and PTV were recorded after 12 weeks of orthodontic loading. To correlate PTV with variables, the cortical bone thickness (mm) and bone mineral density (BMD) within the cortical bone and total bone area were calculated with the help of CT scanning. Results: The BMD and cortical bone thickness in mandibular alveolus were significantly higher than those of the maxilla (p < 0.05). The PTV values ranged from -3.2 to 4.8 for 12 weeks of loading showing clinically stable mini-implants. PTV at insertion was significantly correlated with IT (-0.51), bone density (-0.48), cortical bone thickness (-0.42) (p < 0.05) in the mandible, but showed no correlation in the maxilla. PTV before removal was significantly correlated with RT (-0.66) (p < 0.01) in the mandible. Conclusions: These results show that the periotest is a useful method for the evaluation of mini-implant stability, but it can only be applied to limited areas with thick cortical and high density bone such as the mandible.

ORTHODONTIC TREATMENT WITH MINISCREWS IN MIXED DENTITION (혼합치열기의 miniscrew를 이용한 교정치료)

  • Lim, Su-Min;Yang, Yeon-Mi;Kim, Jae-Gon;Baik, Byeong-Ju;Lee, Yong-Hun;Shin, Jeong-Geun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.2
    • /
    • pp.367-375
    • /
    • 2008
  • Anchorage plays an important role in orthodontic treatment. Skeletal anchorage like the miniscrew is considered a more effective method in anchorage control than conventional anchorage which needs much patient's cooperation. The miniscrew offers many advantages. 1) It is easy to insert and to remove. 2) It can endure the force needed for moving teeth. 3) It can be immediately loaded and 4) Patient cooperation is not needed. 5) It is economic compared to other skeletal anchorage systems. In comparison to adult's bones, children's bones have comparatively poor bone quality and quantity. Therefore, it is hard to obtain primary stability in younger patients. However, if the miniscrew can be retained successfully, it will be effective in many orthodontic treatments. In these cases, we used the miniscrew in correcting of diastema, in aligning dental midline, and in rendering a forced eruption of impacted tooth in mixed dentition patient. We obtained satisfactory results.

  • PDF

A Study on the Perceptions of Cyber English Learners on the Usefulness of Online Grammar Checker (온라인 문법 검사기의 유용성에 대한 사이버 영어학습자들의 인식에 관한 연구)

  • Moon, Dosik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.9-15
    • /
    • 2021
  • The current study examined the cyber learners' perceptions of the educational usefulness of Grammarly, an online grammar checker, after it was used to provide feedback to cyber university students in a situation where the instructor could not provide sufficient feedback on their written work in English. The survey results, revealed that the majority of learners had positive attitudes to the usefulness of Grammarly. In particular, the feedback immediately available whenever needed was regarded as helpful in improving English sentences, and most learners were highly satisfied with the amount of the feedback provided by Grammarly. It was also found that Grammarly had positive effects in terms of the affective domains, helping learners to improve their interest and confidence in English writing. In particular, Grammarly was found to be effective in reducing writing anxiety in English, one of the main factors negatively affecting writing performance in English. However, along with these positive results, limitations such as inaccurate feedback and inadequate explanation of errors were also found. Therefore, when Grammarly is used for English education, it is necessary to conduct multifaceted research to develop effective teaching methods that can minimize the problems that may arise from these limitations.

Physicochemical Properties of Loin and Rump in the Native Horse Meat from Jeju (제주산 재래 마육의 등심부위와 볼기부위의 물리화학적 특성)

  • Kim Young-Boong;Jeon Ki-Hong;Rho Jung-Hae;Kang Suk-Nam
    • Food Science of Animal Resources
    • /
    • v.25 no.4
    • /
    • pp.365-372
    • /
    • 2005
  • This study was carried out to investigate the Physiochemical Properties of loin and rump in the native horse meat from Jeju. In the analysis of chemical composition of loin and rump, the result showed $72.2\%\;and\;73.8\%$ in moisture content $20.1\%\;and\;21.2\%$ in crude protein, $2.42\%\;and\;3.08\%$ in crude Int and $0.13\%\;and\;0.14\%$ in crude ash respectively. Glutamic acid was 3,275mg/100g and 3,577mg/100g in loin and rump each and it had highest result in amino acid analysis. K content was 388.0mg/100g which showed highest result in mineral analysis and next contents were P>Na>Mg>Ca. Oleic acid had highest result in fatty acid composition which were $62.64\%\;and\;63.77\%$ in loin and rump respectively. Cholesterol content of loin and rump were 43.25 and 43.57 mg/100g but showed no significant differences to the part. pH of loin and rump were 5.60 and 5.75 which had no significant differences. Loin had Higher result than that of rump with no significant differences in WHC and springiness of texture analysis. Redness of rump was higher than that of loin. In the sensory evaluation, there were significant differences in the color and odor. Loin had higher result than that of rump in the overall palatability but showed no significant differences. With the result of this experiment native horse meat from Jeju could be understood as good meat resources.