• Title/Summary/Keyword: 중심 X선

Search Result 78, Processing Time 0.025 seconds

The Assessment of Tube Incidence Angle for Minimizing the Patellofemoral Joint Overlap Distance in Merchant View (Merchant 검사 시 슬개대퇴관절 겹침 최소화를 위한 중심 X선 입사각에 대한 평가)

  • Ko, Ye-Weon;Joo, Young-Cheol;Kim, Min-suk;Go, Yu-Rim
    • Journal of radiological science and technology
    • /
    • v.43 no.3
    • /
    • pp.161-167
    • /
    • 2020
  • This study aimed to found out the effect of patellofemoral overlap distance by changing femur thickness and center X-ray angles in Merchant method images. Based on the femur thickness, it suggested tube angle minimizes overlap. It was conducted by Merchant method, a knee tangential view, and the image was obtained by changing the thigh thickness from 14 to 20 cm and the center ray angle from 60°, 57°, 55°. The images were measured by five researchers using a method of measuring the overlap, which was designed by them. The results showed at 60°, 57°, 55° angle, the patellofemoral overlap distance resulted in 0.47±0.66 to 20.89±0.65 cm, 2.26±0.28 to 15.73±0.62 cm, 1.39 ± 0.83 to 12.49 ± 0.37 cm. However, for 57° and 55°, no overlap in thickness under 14.5 and 14 to 15.5 didn't appear. it showed high correlation between femur thickness and overlap. The difference in the mean value of overlap in each group showed a statistically significant difference (p<0.01), all were classified as independent groups in the post-hoc test. In all images, the patellofemoral overlap distance increased as the thickness increased, and at the average thickness of Korean men and women, overlap decreased when reducing center ray. When conducting Merchant tests on Koreans, it was suggested it would be useful to use 57° angle because it minimize the effects of overlap and intrusions of tibia.

THE ANALYSIS OF THE POSITIONAL RELATIONSHIP OF CONDYLOID PROCESS WITH MANDIBULAR FOSSA AND MORPHOLOGICAL CLASSIFICATION OF CONDYLAR HEAD IN T.M.J. TROUBLE PATIENTS (악관절 기능장애 환자에 있어서 관절돌기의 위치적 관계 및 그 형태에 관한 방사선학적 연구)

  • Park Chang Sik
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.11 no.1
    • /
    • pp.7-22
    • /
    • 1981
  • A morphological and positional classification was undertaken in the transcranial and transorbital views of 174 traceable films which had been selected from those of 274 patients and previous tracing was performed. For the positional analysis, the author adopted the method which is not influenced by TMJ remodelling, and for the morphological classification, made progress the general method by adding indefinite type to four basic types. The aims of this sutudy consists in performing positional and morphological analysis of condylar head and in its morphological and positional variation in symptomatic patients. I want to express my sincere gratitude to Prof. Park, Tae Won in Seoul National University, interesting me in this field researches and for his never failing interests. I would lide to thank Prof. Ahn, Hyung Kyu and Prof. You, Dong Soo for helpful discussion and critical readings. The author is also indebted to Prof. Fuchihate Hajime in Osaka University, Prof. Uemura, Shusaburo and the late Dr. Nishihara, Heihachi for fruitful discussion and encourgements.

  • PDF

Evaluation to X-ray Tube Variable Beam Limiting Device Ability Test, Collimation and Beam Alignment Test of Diagnostic X-ray Unit (진단용 X선발생장치의 X선관 가변조리개 성능검사와 조사야일치검사 및 중심선속 일치검사에 대한 평가)

  • Im, In-Chul;Lee, Sang-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.3
    • /
    • pp.250-255
    • /
    • 2009
  • This study performed and evaluated the performance test in 40 general X-ray units among diagnostic X-ray units, which were being used in hospitals of gyeongsangnam-do gimhae-si through X-ray tube variable limiting device ability test, the light field and X-ray field alignment test and collimation and beam alignment test of diagnostic X-ray unit. The results are as followings: In a variable beam limiting device ability test, the result of maximum X-ray field test showed that 4(10%) of were incongruent while the result of minimum X-ray field test represented that 5(12.5%) of were incongruent. The result of the light field and X-ray field alignment test showed 23(57.5%) of were within 2% of maximum permissible level and the other 17(42.5%) units were misalignment. The result of beam alignment test represented that 11(27.5%) coincided and another 11(27.5%) within $0.5^{\circ}$ respectively, 10(25%) were $0.6^{\circ}-1.5^{\circ}$ intervals, 7(17.5%) were $1.6^{\circ}-3^{\circ}$ and 1(2.5%) were more than $3^{\circ}$.

A Study on the Accuracy and Convenience of Imaging Method Using Support Device in Knee Joint Lateral Radiography (슬관절의 측면 방사선 촬영에서 보조기구를 이용한 검사방법의 정확성과 편의성에 대한 연구)

  • Uhm, Soyeong;Cho, Yongkeun;Kang, Sungjin
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.253-262
    • /
    • 2017
  • In lateral projection imaging method of knee joint, a method that adjusts the incidence angle of central X-ray toward the head side to $5{\sim}7^{\circ}$ in true lateral position which is existing recommended is called imaging method A, Method of imaging the central X-ray perpendicular to the horizontal plane of the examination table toward the knee is called imaging method B, and a method in which the central X-ray is perpendicularly applied to the joints while the lateral side of the distal tibia is compensated by radiolucent materials is called as method C. After tests each imaging method to classified study subject respectively, the joint space distance and the distance between lateral and medial condyle of femur were measured and compared as the quantitative index from the three imaging methods. In addition, the convenience of each imaging method was confirmed through questionnaires to practician. According to the result of the quantitative index, there is no statistically significant difference in imaging method A and C(p>0.05). However, imaging method B showed a significant difference in both A and C(p<0.05). As a result of evaluating the convenience of the imaging method, imaging method A was relatively assessed lower in all items than imaging methods B and C, and as a small difference, imaging method B is assessed higher than C. In this study suggested new knee joint lateral projection imaging method, by using a simple support device, could describe joint space as not much different as existing recommended method without some complex process, and could increase convenience of the practician in the process of the imaging.

Monte Carlo Simulation for absorbed dose in PMMA phantom during the low-energy X-ray irradiation (저 에너지 X선 조사 시 PMMA 팬텀 내의 흡수선량 평가를 위한 몬테카를로 시뮬레이션)

  • Kim, Sang-Tae;Kang, Sang-Koo;Kim, Chong-Yeal
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.383-389
    • /
    • 2011
  • This study offered a new method to calculate absorbed dose of actual patients through Monte Carlo Simulation by using the linkage of Geant4 and DICOM, and, the experimental value of absorbed dose at the center and Geant 4 simulation result according to the depth of PMMA mock phantom were compared by using MOSEF in order to verify Geant4 calculation code. In the area where there was no air space between the irregular gap due to incomplete compression of PMMA slab, the differences were $0.46{\pm}4.69$ percent and $-0.75{\pm}5.19$percent in $15{\times}15cm^2$ and $20{\times}20cm^2$ respectively. Excluding the error due to incomplete compression of PMMA mock phantom, the calculation values of the Monte Carlo simulation by linkage of Geant4 and DICOM was the same.

Comparison of Center Error or X-ray Field and Light Field Size of Diagnostic Digital X-ray Unit according to the Hospital Grade (병원 등급에 따른 X선조사야와 광조사야 간의 면적 및 중심점 오차 비교)

  • Lee, Won-Jeong;Song, Gyu-Ri;Shin, Hyun-yi
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.245-252
    • /
    • 2020
  • The purpose of this study was intended to recognize the importance of quality control (QC) in order to reduce exposure and improve image quality by comparing the center-point (CP) of according to hospital grade and the difference between X-ray field (XF) and light field (LF) in diagnostic digital X-ray devices. XF and LF size, CP were measured in 12 digital X-ray devices at 10 hospitals located in 00 metropolitan cities. Phantom was made in different width respectively, using 0.8 mm wire after attaching to the standardized graph paper on transparent plastic plate and marked as cross wire in the center of the phantom. After placing the phantom on the table of the digital X-ray device, the images were obtained by shooting it vertically each field of survey. All images were acquired under the same conditions of exposure at distance of 100cm between the focus-detector. XF and LF size, CP error were measured using the picture archiving communication system. data were expressed as mean with standard error and then analyzed using SPSS ver. 22.0. The difference in field between the XF and LF size was the smallest in clinic, followed by university hospitals, hospitals and general hospitals. Based on the university hospitals with the least CP error, there was a statistically significant difference in CP error between university hospitals and clinics (p=0.024). Group less than 36-month after QC had fewer statistical errors than 36-month group (0.26 vs. 0.88, p=0.036). The difference between the XF and LF size was the lowest in clinic and CP error was the lowest in university hospital. Moreover, hospitals with short period of time after QC have fewer CP error and it means that introduction of timely QC according to the QC items is essential.

Monostotic Fibrous Dysplasia in the Metacarpal Bone: A Case Report (중수골에 발생한 단골성 섬유성 이형성증: 1예 보고)

  • Cho, Han-Il;Park, Sung-Hoon;Juhng, Seon-Kwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.203-206
    • /
    • 2009
  • Fibrous dysplasia is a slowly progressive, benign disorder characterized by fibrous tissue replacement of skeleton and may affect solitary or multiple bones. Monostotic fibrous dysplasia mainly occurrs in the rib, femur and tibia, however, rarely in the hand. We report a case of monostotic fibrous dysplasia confined to the 2nd metacarpal bone with findings of plain radiographs and MR imaging.

  • PDF

Amorphization Process Induced by mechanical Alloying under N2 Gas Atomosphere in Cu-V and Fe-Cr System. (질소가스 분위기 중 기계적 합금화에 의한 Cu-V 및 Fe-Cr 계의 비정질화 과정)

  • Lee, Chung-Hyo
    • Korean Journal of Materials Research
    • /
    • v.6 no.8
    • /
    • pp.796-800
    • /
    • 1996
  • 질소가스 분위기 중에서 Cu30V70 및 Fe30Cr70 혼합분말을 기계적 합금화 (MA)처리한 결과, 두 합금계에서 비정질화가 관찰되었다. 결정질에서 비정질상으로의 구조변화 과정을 Xtjs 회절 및 중성자 회절법에 의해 관찰되었다. 결정질에서 비정질상으로의 구조변화 과정을 X선 회절 및 중성자 회절법에 의해 관찰하였다. 그 결과, 이 합금계에서의 비정질화는 각 결정구조에서 전형적으로 존재하는 8면체 unit가 선택적으로 붕괴되어 4면체 unit로 변화되어 가는 과정임을 알 수 있었다. 또한, 중성자회절 결과로부터 질소원자는 금속원자로 이루어진 4면체의 중심에 위치하고 있음을 알 수 있었다.

  • PDF

Assessment of Congruence Angle according to the Central X-ray in the Merchant View of Patellofemoral Joint (슬대퇴관절의 Merchant View에서 중심 X선 위치에 따른 일치각 평가)

  • Kim, Hyun-jin;Joo, Yeong-chul;Choi, Jae-ho;Lim, Woo-taek
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.423-428
    • /
    • 2019
  • The Precise measurement of the knee's Congruence angle is required for diagnosis of patella dislocation. The purpose of this study is to consider the distortion diagram and usefulness about the test of the bilateral side and one side through the evaluating congruence angle from Merchant view of patellofemoral joint to central X-ray. We've evaluated the sulcus angle and Congruence angle following central X-ray's changes when we took Merchant view of patellofemoral joint aimed to right lower limb from human whole body phantom. The subject of the evaluation was classified as normal group and varus group, and the varus group has experimented with External rotation of legs as 15° and 30°. When normal groups result as 0, 7.5, 15 cm, it was measured as 17.25 ± 1.34°, 19.60 ± 1.41°, 20.55 ± 1.77° each. The gap between minimal and maximum angle was 3.3°, and the value was shown as getting bigger when it further away from the centeral X-ray. When Congruence angle in 15° varus group was 0, 7.5, 15 cm, it was each 16.45 ± 1.34°, 17.10 ± 0.99°, 17.80 ± 1.13°. And when Congruence angle in 30° varus group was 0, 7.5, 15 cm, it was measured each 18.35 ± 1.63°, 18.95 ± 1.06°, 19.60 ± 1.41°. The difference between minimum and maximum of angle in 15° varus group and 30° varus group was each 1.35° and 1.25°, the angles have shown as increasing the further away from the center. The patellofemoral joint showed that the congruence angle increases as the further away from Central X-ray, and also it is judged that is possible to change the congruence angle by a degree of varus knee. Thus, accurate measurement of the congruence angle is shown to advantage that methods for examining by split each side at two times than methods for examining both sides at a time. Therefore, it is expected to helpful on the diagnostic side of patella dislocation and subluxation.

Basic Measurements and Dosage Compensation for Total Body Irradiation (전신조사를 위한 선량 측정과 보상)

  • 김진기;권형철;김정수;김부길;추성실
    • Progress in Medical Physics
    • /
    • v.3 no.1
    • /
    • pp.25-34
    • /
    • 1992
  • For the TBI with medical linear accelerator(6.10MV), we measured basic data for dosage calculation and designed compensation filters to improve dose uniformity. At the distance of 3.4cm from the source, using the specially designed compensation filters reduced with in ${\pm}$5% for mid-depth dose in the phantom seated with flexion of the legs in the field sige up to 120${\times}$120cm$^2$ for the whole body. In repeated measurements for the dose distribution with humanoid phantom contained paraflin compound, measurement error using the TLD chips were less than ${\pm}$5%.