• Title/Summary/Keyword: 주파수-파수 분석

Search Result 139, Processing Time 0.034 seconds

RF Characteristics of TO-can Packaged FP-LD Optical Transceiver Module (TO-can 패키지 레이저 다이오드 모듈의 주파수 특성 개선)

  • 이동수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.8-12
    • /
    • 2003
  • Characteristics of optical transceiver module in radio frequency(RF) band were investigated with TO-can packaged Fabry-Perot laser diode(FP-LD). R-L-C parameters for equivalent circuit model of the LD were extracted with an impedance analyzer. With this model, impedance matching to the packaged LD could be performed by eliminating inductive components of the leads in the package by using lumped chip capacitors that have opposite reactance, while it shows resonance dip in low frequency band. The resonance dip could be removed using lumped elements for impedance matching by shifting the resonance frequency to the region out of interest.

Technical Trend of Wireless Transmission Link in the Frequency Range of Above 10GHz (고주파수대(10GHz 이상) 무선 전송 링크 이용 기술 표준화 동향)

  • Lee, J.H.;Sim, D.W.;Chong, Y.J.
    • Electronics and Telecommunications Trends
    • /
    • v.27 no.6
    • /
    • pp.104-113
    • /
    • 2012
  • 2012년 6월 30일자로 방송통신위원회에서는 10~60GHz 대역의 고정업무용 주파수 지정에 관한 입안 예고를 공고한 바 있다. 본고에서는 이 입안 예고의 배경이 되는 고정업무에 관한 국제 표준화 기구인 ITU-R(International Telecommunication Union-Radio Sector) 연구반의 표준화 동향에 대해 소개하고, 고주파 대역, 고정업무 시스템의 국내외 기술개발 동향을 소개한다. 또한, 국내외 고주파 대역 이용 현황을 국내 현황과 비교하고, 이를 통해 입안 예고된 고정업무용 주파수 지정의 개정 방안에 대해 간략히 소개하여, 향후 국내 전파통신망의 미래상을 전망할 수 있도록 한다.

  • PDF

Development of numerical method to predict broadband radiation noise resulting in fluid-induced vibration and acoustic-induced vibration of pipe (배관의 유동 유발 진동 및 음향 유발 진동 기인 광대역 방사 소음 예측을 위한 수치 해석 기법 개발)

  • Sangheon Lee;Cheolung Cheong;Songjune Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.112-121
    • /
    • 2024
  • The pipping system is widely used in many industries as equipment for transporting fluids over long distances. In high-pressure pipe, as the speed of the fluid increases, a loud noise is generated. Therefore, various studies have been conducted to reduce pipe noise. In this paper, a pipe noise analysis was developed to predict and quantitatively assess the flow-induced vibration and acoustic-induced vibration due to valve flow in high-temperature and high-pressure. To do this, a high-fidelity fluid analysis technique was developed for predicting internal flow in the pipe with valve. In additional, the contribution of compressible/incompressible pressure by frequency band was evaluated using the wavenumber-frequency analysis. To predict a low/middle frequency pipe noise, the vibroacoustic analysis method was developed based on Finite Element Method (FEM). And the pipe noise prediction method for the middle/high frequency was developed based on Statistical Energy Analysis (SEA).

Development of Noise-proof Facility Considered with Soundproofing Materials in a Tunnel Blasting (터널 발파에서 방음재질을 고려한 방음문 개발에 관한 연구)

  • Jeoung, Jae-Hyeung;Won, Yeon-Ho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.3
    • /
    • pp.27-35
    • /
    • 2011
  • This study investigated a sound reduction degree by each soundproofing materials and the sound pressure level of a main frequency range to develop soundproofing facilities installed for reducing sound in a tunnel blasting. The frequency range and sound pressure level of soundproofing materials(eg. sand and water etc.) mainly used at a working spot were measured using the experimental apparatus considered with blasting situation. The full scale pilot test was also carried out using developed soundproofing facilities in this study. And the performance of developed soundproofing facilities was analyzed. As a result, the developed soundproofing facilities using water in sound insulation materials could reduce about 10dB(A) of blasting noise in compare with the existing soundproofing facilities.

Physical layer performance for coexistence of CS/CDMA based WPAN and CCK based WLAN (CS/CDMA 기반의 WPAN 과 CCK 기반의 WLAN 공존 환경에서의 물리계층 성능 분석)

  • 류형직;김성필;김명진;조진웅
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.285-288
    • /
    • 2003
  • Code Select CDMA(CS/CDMA)(1)는 입력 데이터 열에 의하여 여러 채널의 직교코드를 선택하여 전송하는 기술로, 멀티코드 CDMA 의 구조를 가지면서도 전송신호의 크기가 일정하여 저가의 비선형 증폭기를 사용하여 구현 할 수 있다. 특히 입력 비트열을 부호화하여 직교코드들의 합을 일정하게 만드는 constant amplitude coded (CA-) CS/CDMA (2) 전송 기술은 2.4GHz ISM 대역의 WPAN을 위한 전송방식의 하나로 고려되고 있다. 이주파수 대역은 WLAN, 블루투스 등을 비롯한 여러 시스템이 존재하는 대역이므로 다른 종류의 시스템과의 상호 간섭의 문제를 분석할 필요가 있다. 본 논문에서는 2.4GHz ISM 대역을 같이 사용하게 될 IEEE 802.11b WLAN 과 CA-CS/CDMA 기반의 WPAN 상호 영향을 물리계층 측면에서 분석한다. IEEE 802.11b 모델로 11MHz 대역폭을 갖는 CCK (Complementary Code Keying) 변조방식을 대상으로 하며, CA-CS/CDMA 와의 중심주파수 차이에 따른 비트오율 성능을 신호대 간섭전력의 비를 변화시켜가면서 컴퓨터 모의실험을 통하여 분석하였다.

  • PDF

Log Count Rate Circuits for Checking Electronic Cards in Low Frequency Band Reactor Power Monitoring (저주파수대의 원자로 출력신호 점검을 위한 대수 카운트레이트 회로)

  • Kim, Jong-ho;Che, Gyu-shik
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.6
    • /
    • pp.557-565
    • /
    • 2020
  • In order for thermal degradationIn, excore nuclear flux monitoring system, as a monitoring and signal processing methodology of reactor power, monitors neutron pulses generated during nuclear fission as frequency status, and converts them into DC voltage, and then log values resultantly. The methods realy applied in the nuclear power plant are to construct combination of counters and flip-flops, or diodes and capacitors up to now. These methodes are reliable for relative high frequencies, while not credible for reasonable low frequencies or extreme low values. Therefore, we developed the circuit that converts frequencies into DC voltages, into and into log DC values in the wide range from low Hz to several hundred high kHz. We proved their validities through testing them using real data used in nuclear power plant and analyzed their results. And, these methods will be used to measure the neutron level of excore nuclear flux monitoring system in nuclear power plant.

Performance of Parametric Array Communication System in Underwater AWGN Channel (수중 AWGN 채널에서의 파라메트릭 배열 통신 성능)

  • Lee, Jaeil;Lee, Chong Hyun;Bae, Jinho;Paeng, Dong-Guk;Kim, Won-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.4
    • /
    • pp.294-300
    • /
    • 2013
  • In this paper, we present performance analysis results of parametric array communication system in terms of theoretical BER and channel capacity of MIMO in underwater AWGN channel by using simplified SNR of difference frequency. The SNR of the difference frequency is calculated by using transmission loss, noise level, and source level of difference frequency in which nonlinear effect is considered. By assuming primary frequencies as 210 kHz and 190 kHz, difference frequency as 20 kHz, transducer diameter as 0.1 m, and noise level as 50 dB and the requested BER as $10^{-4}$, we obtain parametric array communication range gains over the communication system using primary frequency of 59.11 km in fresh water and 5 km in sea water, respectively. Also we obtain range gains of 38.84 km and 46.38 km in fresh water, and 3.88 km and 4.38 km in sea water when we use SISO and $2{\times}2$ MIMO parametric array communications for the channel capacity of 10 bps/Hz.

Resonant Frequency in Rectangular Microstrip Patch Antenna on Anisotropic Substrates with Airgap and Permittivity Superstrate (공기갭과 유전체 덮개층을 갖는 이방성 기판 위의 마이크로스트립 패치 안테나의 공진 주파수 해석)

  • 윤중한;이상목;곽경섭
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.11B
    • /
    • pp.1600-1606
    • /
    • 2001
  • Resonant frequency in rectangular microstrip patch antenna on anisotropic substrates with airgap and superstrate are analyzed. Dyadic Green function is derived for selected anisotropic material by constitutive relation. From these results, integral equations of electric fields are formulated using Fourier transform in space region. The electric field integral equations are discretized into the matrix form by applying Galerkin\`s moment method. Sinusoidal functions are selected as basis functions because they resemble in the actual standing wave on the patch. To verify the validity of numerical result, we compare our result with existing one and get a good agreement between them. From the numerical results, the resonant frequency in the variation of air gap, patch length and anisotropy ratio are presented and analysed.

  • PDF

Robust Audio Watermarking Using Frequency Coefficient Analysis for MP3 Compression Attack (MP3 압축 공격에 강인한 주파수 계수 분석을 이용한 오디오 워터마킹)

  • Jeong Won-Kyo;Lee Kyeong-Hwan;Woo Hong-Chae;Lee Yong-Doo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.8
    • /
    • pp.492-497
    • /
    • 2005
  • In this paper, we suggest that the new volume of robust audio watermarking method protects form the MP3 compression attack, mostly used in audio field. Watermarks were inserted at the coefficients repeatedly from low frequencies to high frequencies after DCT transform in commonly used Cox's spread spectrum method. However, our method could be investigated losing frequency when MP3 attacks and make order by small amount of losing frequency and then insert watermarks rightly through statistical analysis. In the result about various sound clips, the suggested method have better performances than Cox's method by preserving watermarks and reducing distortions of the original sounds.

Initial results from spatially averaged coherency, frequency-wavenumber, and horizontal to vertical spectrum ratio microtremor survey methods for site hazard study at Launceston, Tasmania (Tasmania 의 Launceston 시의 위험 지역 분석을 위한 공간적 평균 일관성, 주파수-파수, 수평과 수직 스펙트럼의 비율을 이용한 상신 진동 탐사법의 일차적 결과)

  • Claprood, Maxime;Asten, Michael W.
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.132-142
    • /
    • 2009
  • The Tamar rift valley runs through the City of Launceston, Tasmania. Damage has occurred to city buildings due to earthquake activity in Bass Strait. The presence of the ancient valley, the Tamar valley, in-filled with soft sediments that vary rapidly in thickness from 0 to 250mover a few hundreds metres, is thought to induce a 2D resonance pattern, amplifying the surface motions over the valley and in Launceston. Spatially averaged coherency (SPAC), frequency-wavenumber (FK) and horizontal to vertical spectrum ratio (HVSR) microtremor survey methods are combined to identify and characterise site effects over the Tamar valley. Passive seismic array measurements acquired at seven selected sites were analysed with SPAC to estimate shear wave velocity (slowness) depth profiles. SPAC was then combined with HVSR to improve the resolution of these profiles in the sediments to an approximate depth of 125 m. Results show that sediments thicknesses vary significantly throughout Launceston. The top layer is composed of as much as 20m of very soft Quaternary alluvial sediments with a velocity from 50 m/s to 125 m/s. Shear-wave velocities in the deeper Tertiary sediment fill of the Tamar valley, with thicknesses from 0 to 250m vary from 400 m/s to 750 m/s. Results obtained using SPAC are presented at two selected sites (GUN and KPK) that agree well with dispersion curves interpreted with FK analysis. FK interpretation is, however, limited to a narrower range of frequencies than SPAC and seems to overestimate the shear wave velocity at lower frequencies. Observed HVSR are also compared with the results obtained by SPAC, assuming a layered earth model, and provide additional constraints on the shear wave slowness profiles at these sites. The combined SPAC and HVSR analysis confirms the hypothesis of a layered geology at the GUN site and indicates the presence of a 2D resonance pattern across the Tamar valley at the KPK site.