• Title/Summary/Keyword: 주파수 조정기

Search Result 195, Processing Time 0.033 seconds

A Study on Frequency Controlled Bandwidth adjustable Bandpass Filter (주파수제어 대역폭조정 대역통과 여파기에 관한 연구)

  • 최갑석
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.12 no.1
    • /
    • pp.18-26
    • /
    • 1975
  • In this paper, a frequency controlled bandwidth adjustable bandpass filter consisting of 4-path system is precented. It is shown that this system has characteristics similar to ihose of the magneticuly coupled double tuned amplifier and the center frequency of the passband is able to be shifted contineolisly. The adjustable range of the bartdwidth of the filter system is anslyzed for she case of the double and single tuned characteristics. The experiment has been conducted to verify the theory of this system and the experimental resulis are in good agreement with the theoretically calculated values.

  • PDF

다중정현파 소음제어를 위한 능동소음제어 알고리듬

  • 이승만;류차희;윤대희
    • Journal of KSNVE
    • /
    • v.5 no.4
    • /
    • pp.453-460
    • /
    • 1995
  • 본 논문에서는 정현파 소음을 제어하기 위한 filtered-x LMS에 바탕을 둔 새로운 적응 알고리듬을 제안하였다. 이러한 알고리듬은 두개의 연속적인 계수조정 식으로, 제어기의 계수를 조정한다. 서로 독립인 각 주파수별로 처리하기 때문에 빠른 수렴을 얻을 수 있다. 두번째식은 이차경로로 인한 위상지연을 추정한다. 정현 파 신호 주파수보다 4배 이상 빠른 표본화 주파수를 선택하여 추정된 위상지연 추정 값은 $2{\pi}f_0$만큼 오차를 나타내며, 이 값은 $\pi$2보다 작다. 정현파 신호의 주파수를 알면 이러한 오차는 $2{\pi}f_0$를 더함으로써 제거할 수 있다. 이러한 방법은 위상지연이 $\pi$2보다 큰 경우 수렴속도를 증가시킨다는 사실을 실험을 통하 여 알 수 있다. 추정된 위상지연은 제어기 계수값을 조정하는데 필요한 필터링된 참조신호를 발생시키믄데 사용된다. 참조신호의 위상지연이 각 주파수 성분별로 수행 되기 때문에, 콘볼루션 연산이 생략되어 계산량을 줄일 수 있다. 또한 연속적으로 위상지연을 추정하기 때문에 시변 상황에 적용이 가능하다. 조정식의 수렴조건을 유도하였다. 제안된 알고리듬은 제어기 계수를 추정하는데 바이어스가 없으며, 위상 지연추정을 위한 수렴상수의 최대허용치는 제어기계수에 대한 수렴상수에 반비례함을 이론적으로 분석을 통해 알 수 있다. 모의실험을 통하여 제안된 알고리듬이 filtered-x LMS 알고리듬에 바탕을 둔 다른 알고리듬보다 환경변화에 우수한 성능을 보임을 알 수 있다.

  • PDF

A Design of a 5 GHz Low Phase Noise Voltage Tuned Dielectric Resonator Oscillator Using Loop Group Delay (루프 군지연을 이용한 저위상 잡음 5 GHz 전압제어 유전체 공진기 발진기 설계)

  • Son, Beom-Ik;Jeong, Hae-Chang;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.3
    • /
    • pp.269-281
    • /
    • 2014
  • In this paper, a systematic design of a low phase noise voltage-tuned dielectric resonator oscillator(VTDRO) using loop group delay is proposed. Designed VTDRO is closed-loop type and consists of a cascade connection of a resonator, phase shifter, and amplifier. Firstly, a reference VTDRO is fabricated and its phase noise and electrical frequency tuning range are measured. Both the phase noise and electrical frequency tuning range depend on the loop group delay. Then, a required value of loop group delay for a new VTDRO with a low phase noise can be systematically computed. In addition, its phase noise and electrical frequency tuning range can be theoretically estimated using those obtained from the measurement of the reference VTDRO. When the loop group delay increases, the phase noise decreases and the electrical frequency tuning range also decreases. The former predominantly depends on the resonator structure. Therefore we propose a systematic design procedure of a resonator with high group delay characteristics. The measured loop group delay of the new VTDRO is about 700 nsec. The measured phase noise of the new VTDRO show a state-of-the-art performance of 154.5 dBc/Hz at 100 kHz frequency offset and electrical frequency tuning range of 448 kHz for a voltage change of 0~10V. The oscillation power is about 4.39 dBm.

The development of simulation model to verify controller of 54MW power energy storage system for frequency regulation of power system (54MW 주파수조정용 전력에너지저장장치 제어기 검증용 모의모델 개발)

  • Lim, Geon-Pyo;Kang, Dae-Kyun;Park, Chan-Wook;Cho, Seong-Min;Kim, Soo-Yeol;Yoon, Yong-Beum
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.633-634
    • /
    • 2015
  • 주파수조정용 배터리 에너지저장장치의 주파수조정용으로써의 효용성을 확인하기 위해 한국전력공사 전력연구원 ESS연구사업단에서는 제주시 조천변전소에 4MW급 ESS실증단지의 조성과 제어시스템의 실증을 완료하였다. 이후 주파수조정용 대용량 에너지저장장치 운전제어기술을 개발하여 서안성, 신용인 변전소에 설치된 52MW ESS에 각각 주파수추종운전용 28MW와 자동발전제어용 24MW 제어시스템기술을 적용시켰다. 대용량 에너지저장장치 운전제어기술을 개발하기 위하여 제어시스템과 연계할 수 있는 시뮬레이션이 가능한 에너지저장장치 및 전력계통을 개발하여 시험하였다. 본 논문에서는 제어시스템과 연계 가능하고, 운전원 인터페이스를 제공하며, 시뮬레이션이 가능한 전력계통과 에너지저장장치로 구성된 제어기 검증용 시뮬레이터 개발에 대하여 소개하고자 한다.

  • PDF

A Novel Design Method of Direct Coupled BPF(Band Pass Filter) Based on EM Simulation of Individual Resonator (개별 공진기의 EM 시뮬레이션에 기초한 새로운 직접결합 대역여파기 설계 방법)

  • Yang, Seong-Sik;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.4
    • /
    • pp.333-343
    • /
    • 2009
  • The BPF designed by the formula based on strip line shows the center frequency shift and distortion in filter response and this becomes more significant with higher frequency. In this paper, the novel design based on EM simulation is proposed. In the design, the filter is decomposed into individual resonators and, for each resonator, the reactance slope and the inverter values are measured and tuned to desired design values for a inverter BPF prototype. The filter composed with such resonators shows the desired filter response without further tuning. This is because possible effects of discontinuities and dispersion are included in the filter parameter extraction. The method can generally apply to all filters that can be transformed into inverter BPF prototype. The procedure is verified by designing a 5th-order SIR filter and quite general to adapt into the design of a parallel coupled line filter, and hair-pin filter.

A Ku-Band Hair-Pin Resonator Oscillator with a New Varactor Coupled Line Structure (개선된 바랙터 결합 선로를 이용한 Ku-Band 헤어핀 발진기 설계)

  • Choi, Kwang-Seok;Won, Duck-Ho;Yun, Sang-Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.1
    • /
    • pp.83-89
    • /
    • 2010
  • In this paper, we propose a new varactor coupled line structure and design the VCO using the proposed structure. The proposed coupled line structure removes the reflected signals from the varactor diode using an added $\lambda$/4 transmission line. The frequency synthesizers are designed using the PLL technique at Ku-band. The synthesizer using the proposed coupled structure has 38 MHz frequency tuning range and -97 dBc/Hz phase noise characteristic at 100 KHz offset frequency. The measured results show improved tuning range as well as the improved phase noise characteristics compared to the conventional designs.

Design of an SIR BPF by a Novel EM Tuning of Individual Resonators (개별 공진기의 EM 조정을 통한 SIR로 구성된 대역 여파기의 설계)

  • Yang, Seong-Sik;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.7
    • /
    • pp.748-756
    • /
    • 2007
  • In SIR filter, fringing capacitances and discontinuities yield a distorted frequency response from those expected by design formulas, especially in higher frequencies. In this paper, a procedure is presented in order to compensate for fringing capacitances and step impedance discontinuities by EM simulation for a 5th order SIR filter. This method propose the procedure of tuning the coupling and the length of individual resonator by EM simulation. For the filter composed by the tuned resonators, no further tuning is required. The procedure is experimentally justified by comparing the measured data of the fabricated filter with the simulation results.

Load Frequency Control using Parameter Self-Tuning Fuzzy Controller (파라미터 자기조정 퍼지제어기를 이용한 부하주파수제어)

  • 이준탁;정동일;안병철;주석민;정형환
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.7 no.2
    • /
    • pp.52-65
    • /
    • 1997
  • This paper presents a design technique of self tuning fuzzy controller for load frequency control of power system. The proposed parameter self tuning algorithm of fuzzy controller is based on the gradient method using four direction vectors which make error between inference values of fuzzy controller and output values of the specially selected optimal controller reduce steepestly. Using input-output data pair obtained from optimal controller, the parameters in antecedent part and in consequent part of fuzzy inference rules are learned and tuned automatically using the proposed gradient method. The related simulation results show that the proposed fuzzy controller is more powerful than the conventional ones for reductions of undershoot and steady-state load frequency deviation and for minimization of settling time.

  • PDF

Frequency Estimation Algorithm for QPSK (QPSK를 위한 주파수 추정 알고리즘)

  • 남옥우;이순규;김상규
    • Proceedings of the IEEK Conference
    • /
    • 2001.09a
    • /
    • pp.837-840
    • /
    • 2001
  • 주파수 추정 알고리즘의 경우 기존에 제안된 방법들 중에서 ML방법은 계산상 너무 복잡하고 구현하기 힘들며, 준-ML 방법들은 이론적인 방법과 비교해 볼 때 다소 단순하긴 하나 역시 구현상의 문제가 따른다. 따라서 본 논문에서는 BWLL환경에 적용할 수 있는 단순하면서도 구현이 용이한 주파수 추정방법을 제안한다. 본 논문에서 제안하는 주파수 추정기는 V&V 위상추정기를 기초로 한다. 성능분석 결과 본 논문에서 제안한 알고리즘을 이용할 경우 최대로 정규화된 심벌율의 0.5%까지 조정이 가능하다. 따라서 아날로그 영역에서의 거친 주파수 조절과정에서 다소 많은 잔류 주파수옵셋이 존재하여도 주파수 복구가 가능하다.

  • PDF

Research of Governor free Respose calculated by power system contribution (계통기여도를 반영한 주파수추종운전 성능 평가에 관한 연구)

  • Byun, Sung-Hyun;Sin, Jung-Sun;Rju, Hyun-Keun;Jeon, Young-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.52-53
    • /
    • 2007
  • 현 CBP(Cost Based Pool)에서 주파수조정은 전기품질유지와 전력계통 안정성 확보에 절대적으로 필요한 계통운영보조서비스의 항목이다. 이는 해외 전력계통에서도 예외없이 채택하여 적용하고 있으며 적극적인 참여를 유도하기 위하여 다양한 비용보상 방안을 시행하고 있다. 순시 주파수조정은 발전기 조속기 특성에 따라 다양한 출력응동특성을 가지고 있으며 이에 따라 계통에 기여하는 바도 달라지게 된다. 따라서 주파수조정에 참여하는 발전기의 계통기여도에 따른 주파수추종운전 능력에 대한 평가를 계량화할 수 있는 방법이 요구된다.

  • PDF