• Title/Summary/Keyword: 주입 제어

Search Result 433, Processing Time 0.022 seconds

KSR-III Helium Fill/prepressurization Umbilical Valve Development (KSR-III 헬륨 주입/선가압 엄비리칼 밸브 개발)

  • 정영석;조기주;조인현;오승협
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.164-167
    • /
    • 2003
  • In generally, Gas fill & drain valve is used in filling Gases to tank on high pressure in launcher The valve is quick coupling type and is separated by manual or remote control. In KSR-III, He gas fill & drain valve separated by remote control is used. In this paper, that are explained about the design specification, the test procedure, the autonomous test result and the flight test result.

  • PDF

Analysis of Angle Estimation Error in Signal Injection Based Sensorless Control Using Analog Filter Circuit (아날로그 필터를 이용한 신호주입 센서리스제어의 각추정 오차 분석)

  • Jung, Sungho;Ha, Jung-Ik
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.267-268
    • /
    • 2013
  • 본 논문에서는 아날로그 필터회로의 신호 증폭비에 따른 센서리스 각추정 성능에 대해 분석 하였다. 신호 주입 센서리스에서 높은 주파수 신호 주입 방법이 선호되는데, 주입 주파수가 커질수록 시스템 임피던스가 증가한다. 따라서 낮은 주파수 주입방법과 동일한 각추정 성능을 얻기 위해서는 상대적으로 큰 주입전압이 필요하다. 특히 전동기의 돌극성이 작거나 ADC의 정밀도가 낮으면 각추정이 불가능한 경우도 존재 한다. 하지만 아날로그 필터회로를 이용하여 주입 주파수 신호를 증폭할 경우 작은 크기의 전압주입으로 각추정이 가능하다. 아날로그 대역통과필터의 신호 증폭비에 따른 최대 각에러 값을 모의 실험을 통해 비교하고, 실제 회로를 설계하여 센서리스 각추정 성능을 시험평가 하였다.

  • PDF

Fine Flow Controlling Device for Medicine Injection (의료 약물주입용 미세 유량 제어 장치)

  • Cho, Su-Chan;Shin, Bo-Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.4
    • /
    • pp.51-55
    • /
    • 2021
  • The nurses manually carry out the intravenous therapy for the patients. Using an Arduino, the fine flow controlling device was invented to provide an ongoing patient care. The medication is injected through a peristaltic pump, and the amount of the solution is controlled with a RGB color sensor. The power of the device is supplied through the batteries. An amount of the injection is measured with LIG strain sensor fabricated by 355nm UV pulsed laser. This system will provide a better medical service.

Development of Pilot Injection Plant for CO2 Underground Storage (이산화탄소 지중저장용 파일럿 주입플랜트 개발)

  • Yoon, Seok-Ho;Kim, Young;Lee, Jun-Ho;Lee, Kong-Hoon
    • Plant Journal
    • /
    • v.9 no.2
    • /
    • pp.42-45
    • /
    • 2013
  • The worldwide issue of greenhouse gas reduction has recently drawn great attention to carbon capture and storage(CCS). In this study, we developed a 10,000 ton/year pilot injection plant for geological storage of carbon dioxide. Major components of the pilot plant include a pressure pump, a booster pump, and an inline heater to bring liquid carbon dioxide into its supercritical state. The test results show that the pilot plant readily achieves the injection pressure and temperature, showing satisfactory control performance. The overall power consumption is 2,000 ~ 2,500 W, more than 75% of which consumed by the pressure pump. This study will facilitate varied research on greenhouse gas reduction as the only domestically developed system for geological injection.

  • PDF

A Design and Implementation of CO2 Infuser for a Carbon Dioxide (카복시 테라피용 CO2 주입기의 설계 및 구현)

  • Park, Sung-Kon;Ahn, Chan-Jin
    • Journal of Digital Contents Society
    • /
    • v.16 no.3
    • /
    • pp.483-492
    • /
    • 2015
  • This thesis analysis the CARBO 3000 that is one of a $CO_2$ infuser and improve its effectiveness. The thesis designs H/W and S/W that controls the $CO_2$ infusing mass compared to the CARBO 3000. Specially the designed H/W has a newly CPU, LCD, a flow velocity controller, a solenoid valve and a flow sensor. Also the designed S/W is composed of GUI and the algorithm to control the $CO_2$ infusing mass. The designed and implemented the $CO_2$ Infuser in this thesis is tested for the performance. The commercial measuring sensor is used for the test. The testing results say that the designed and implemented the $CO_2$ Infuser in this thesis is much more accurate compared to the CARBO 3000 on $CO_2$ infusing.

Effects of Antiscalant on Inorganic Fouling in Seawater Reverse Osmosis Membrane Processes (해수담수화 역삼투막 공정의 무기질오염에 대한 스케일 억제제 효과 연구)

  • Kang, Nam-Wook;Lee, Seock-Heon;Kweon, Ji-Hyang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.9
    • /
    • pp.677-685
    • /
    • 2011
  • The reverse osmosis membrane processes have several operational problems. Fouling by inorganic scale occurs on membrane surface due to increases in concentrations over solubility by retaining ions on feed side of the membrane. Inorganic scales could be controlled by antiscalants or acid addition. In this study, three antiscalants having different characteristics were selected and evaluated on efficiency of $CaCO_3$ scale control. The $CaCO_3$ scale was inhibited by the antiscalants : 0.4 mg/L for SHMP, 0.6 mg/L for Spectra Guard, and 3 mg/L for Flocon 150 N. Increasing concentration factors of simulated sea water resulted in increases in antiscalant doses for the scale control. The increases in doses were positively proportional to the concentrate factors used in this study. Spectra Guard, one of the polyacrylate type antiscalants, was the most effective to control $CaCO_3$ scale. The antiscalants with the different scale inhibition time and doses implied the different control mechanisms.

KSTAR 연료주입계 Piezoelectric Valve 및 제어기 개발

  • Song, Jae-In;Kim, Yeong-Ok;Kim, Gwang-Pyo;Chu, Yong;Park, Gap-Rae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.205-205
    • /
    • 2012
  • Korea Superconducting Tokamak Advanced Research (KSTAR) 장치는 국내 유일의 초전도 자석을 이용한 핵융합 연구 장치로서 초고온의 플라즈마를 생성하여 차세대 에너지원인 핵융합 에너지를 획득하는 것을 목표로 두고 있다. 플라즈마를 생성부터 유지하기 위해서는 수소 동위원소를 토카막 내부로 공급해 주어야 하는데 이러한 수소동위원소를 "연료"라 부르며, 이 연료를 토카막 내부로 공급해 주는 시스템을 연료주입 시스템(Fueling System)이라고 한다. KSTAR에서는 토카막 내부로 고속의 연료 주입이 필요하고 정밀한 양의 연료를 공급하는 밸브를 사용하여야 하며, 이러한 밸브를 제어 할 수 있는 제어기를 필요로 한다. 위의 사항에 적합한 피에조 밸브(Piezoelectric Valve)는 2 msec 이내의 개폐시간과 500 Torr ${\ell}$/s 이상의 유량을 흘려줄 수 있는 피에조 밸브로 압전소자에 가해지는 전압(0~250 V)에 따라 변위의 양에 비례하여 연료가 진공용기 내로 유입된다. 압전소자의 변위는 최대 140 ${\mu}m$로 최적화되어 있어야 하며, 정전용량(Capacitance)는 30~40 nF이어야 한다. 또한 소자에 힘(Force)를 가해 최대 7 N으로 136 ${\mu}m$의 변위를 가진 소자를 사용해야 한다. 피에조 밸브의 특성으로는 아날로그 신호로 작동이 되어야 하며, 유량신호를 피드백하여 밸브의 구동 전압을 정밀하게 제어 되어야 한다. 피드백 제어를 위해 압력센서는 XCS-190 Series를 사용하여 낮은 유량에서도 민감하게 반응하도록 제작하였으며, 고전압이 유기 되었을 때 제어기를 보호하기 위한 정션박스를 설치하였다. 밸브 제어기는 피에조 밸브의 개방 속도를 높이기 위해 밸브 구동 전압을 순간적으로 높이는 POP 전압을 생성하는 기능과 유량 신호를 피드백해서 밸브 구동 전압을 정밀 제어 하는 기능을 가지고 있다. 제어장치는 아날로그 및 디지털 제어회로의 전원용 +15 V DC와 밸브 구동용 +250 V DC 출력용의 전원 공급 장치(Power supply unit), 펄스 및 트리거 신호를 생성하는 Master Programmer unit), Pop 전압과 피드백의 중요한 기능을 수행하는 Valve controller unit로 제작 되었다. 피에조 밸브와 제어기는 상호 작용하여 동작을 원활히 할 수 있도록 특성 실험을 진행하여야 하며, 진공상태에서 Lack의 유무를 확인하여야 한다. 현재 개발 제작된 밸브의 진공누설시험 및 특성실험을 진행하고 있으며, KSTAR 5차 캠페인에 적용할 계획이다.

  • PDF

Development of Polymer Film Mass Production by ion Beam Implantation (이온빔을 이용한 고분자 대전방지 처리 양산기술 개발)

  • Kil, Jae-Keun;Lee, Chan-Young;Shon, Chang-Won;Lee, Jae-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1138-1141
    • /
    • 2004
  • 고분자 재료에 이온을 주입하면 표면전기저항이 이온주입조건에 따라 $10^{16}\Omega/sq$ 에서 $10^7\Omega/sq$ 까지 변하게 되며, 광학적 특성도 변하게 된다. 이는 산업적으로 대전방지 등에 적용이 가능하며 이러한 신소재 개발을 위하여 산업용 이온빔 표면처리 장치를 제작하고 인출광학을 기초로 이온빔을 제어하여 고분자 재료의 이온주입처리 양산기술을 개발하였다. 본 연구에서는 대면적, 대전류 이온빔 인출을 위한 이온원의 광학적 설계 및 빔라인에서의 솔레노이드 전자석을 이용한 빔프로파일 제어방법을 설명하였다. 사용된 고분자 소재는 PC(PolyCarbonate) 및 PET(PolyEthylene Teraphthalate)이며, 질소이온주입조건은 이온에너지 40-50 keV, 이온주입량 $5\times10^{15}$, $1\times10^{16}$, $7\times10^{16}ions/cm^2$의 조건으로 공정을 수행하였다. 또한 대전방지용 고분자 대량생산을 위한 연속 생산조건과 양산공정조건에 따른 표면전기저항변화를 관찰하였다.

  • PDF

Enhancement of Cell Voltage Balancing Control by Zero Sequence Current Injection in a Modular Multilevel Converter (Modular Multilevel Converter에서 영상분 전류주입에 의한 셀간 전압평형화 제어의 향상)

  • Kim, Tae-Hyeong;Kwon, Byung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.159-160
    • /
    • 2014
  • 본 논문에서는 ${\Delta}$결선으로 구성된 Modular Multilevel Converter(MMC)에서 흐르는 전류가 매우 적은 경우 계통에 영향이 없이 셀 직류전압의 불평형을 제어할 수 있도록 영상분전류를 주입하는 방법을 제안하였고, 시뮬레이션을 통해 검증하였다.

  • PDF

Improved Signal Processing Method for IPMSM Sensorless Technique using Switching Frequency Square-wave Voltage Injection (스위칭 주파수의 구형파 전압 주입을 이용한 IPMSM 센서리스 기법의 개선된 신호처리 기법)

  • Nam, S.H.;Park, N.C.;Kim, S.H.
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.15-16
    • /
    • 2012
  • 본 논문에서는 스위칭 주파수의 구형파 전압 주입을 이용한 IPMSM의 센서리스 제어 기법에서 개선된 신호처리 방법을 제안하였다. 제안된 기법에서는 기본파 전류와 고주파 성분 전류추출에 필요한 필터를 간단히 구현함으로써 신호처리에서 발생하는 시지연을 줄일 수 있으며, 그 결과 센서리스 제어의 동특성을 개선할 수 있다. 800[W]급 IPMSM에 대한 실험을 통해 제안된 방법의 타당성을 검증하였다.

  • PDF