A Study on the Seasonal Performances Evaluation of the Horizontal-type Geothermal Heat Exchanger Installed in the Foundation Slabs of Complex Building (주상복합 건축물의 기초 슬래브에 설치된 수평형 지열교환기의 계절별 성능평가)

  • Hwang, Kwang-Il;Woo, Sang-Woo;Kim, Joong-Hun;Shin, Seung-Ho;Kim, Yong-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.11-17
    • /
    • 2007
  • This study evaluates the seasonal performances of the horizontal-type geothermal heat exchanger(HGHEX) installed into the foundation slabs of the complex building located at Seoul. The geothermal system is consisted with totally 31,860m long HGHEX, 16 GSHPs (Ground-source Heat Pump) and 8 circulation pumps. This system supplies cooling and heating to the lobby(F1) and the common spaces(BF1). The average heat exchange temperature differences are $2.7^{\circ}C\;and\;2.5^{\circ}C$ in the summer, $1.5^{\circ}C\;and\;0.5^{\circ}C$ in the winter for the F1 and BF1 respectively. From these results, approximately 400Gcal and 180Gcal of geothermal energy are assumed to have been used during the summer and winter seasons respectively. As a conclusion, the geothermal system is reviewed as a effective utility for heating and cooling at the point of seasonal performances.

A Study on the actual condition of Housing Buildings in the Urban area (도시지역 주거관련 건축물의 사용실태에 관한 연구)

  • Kim, Sung-Hwa;Lee, Jae-Hoon;Kim, Yeung-Bean
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.57-61
    • /
    • 2005
  • The objectives of this study are to illustrate an alternative housing type responding to the social requirements and customers' needs, to suggest the improvement plan for the related laws and regulations through survey of the actual condition for housing buildings such multi have been raised in classification due to that the existing law systems including the current use classification of residential buildings have been defined unclearly. Especially, various social problems have yielded in line with emergence of the housing type which is not legally classified as residential however used for the living purpose practically. Current zoning planning and related law system have rigidity. So, It is required to introduce a flexible classification system which protects the residential environment based on the housing purpose, function and habitability and provides correspondence between residence and ownership/management method. The legal classification system should be revised in a way that the housing use classification corresponds with the zoning system through breakdown of the use classification system

  • PDF

Control Performance Evaluation of Mid-Story Isolation System for Residence-Commerce Complex Building (주상 복합 구조물에 적용된 중간층 면진 시스템의 성능 검토)

  • Park, Kwang-Seob;Kim, Yun-Tae;Kim, Hyun-Su
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.3
    • /
    • pp.33-40
    • /
    • 2019
  • A seismic isolation system is one of the most effective control devices used for mitigating the structural responses due to earthquake loads. This system is generally used as a type of base isolation system for low- and mid-rise building structures. If the base isolation technique is applied to high-rise buildings, a lot of problems may be induced such as the movement of isolation bearings during severe wind loads, the stability problem of bearings under large compression forces. Therefore, a mid-story isolation system was proposed for seismic protection of high-rise buildings. Residence-commerce complex buildings in Korea have vertical irregularity because shear wall type and frame type structures are vertically connected. This problem can be also solved by the mid-story isolation system. An effective analytical method using super elements and substructures was proposed in this study. This method was used to investigate control performance of mid-story isolation system for residence-commerce complex buildings subjected to seismic loads. Based on numerical analyses, it was shown that the mid-story isolation system can effectively reduce seismic responses of residence-commerce complex tall buildings.

A Study on the Estimation for the Flow Coefficient of Elevator Shaft (엘리베이터 샤프트의 유량계수 산정에 관한 연구)

  • Kim, Hak-Joong
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.2
    • /
    • pp.148-157
    • /
    • 2012
  • Recently, evacuation safety of building residents becomes the major concern, as the building has been higher and more complicated. Many high-rise multi use buildings are under construction in Korea. Required evacuation time using stairway is longer in high-rise buildings, moreover it is impossible for the disabled to evacuate by using stairway. For this reason the study on the effectiveness of using elevator for evacuation is being progressed. Elevator shaft flow coefficient is the major factor for the calculation of elevator piston effect. The results of this study can be used for the study of elevator piston effect as basic data. The flow coefficient simulation was performed using FLUENT, commercial CFD program. As a result of the flow coefficient simulation, the coefficient is 0.88 considering the safety factor. This result is verified that the result of experimental study, 0.86 is conservative.

Study on Stagnation Factors Analysis and Improvement Methods through an Evacuation Experiment (피난실험을 통한 피난시간 지연요인 분석과 개선방안에 관한 연구)

  • Han, Woon-Hee
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.57-66
    • /
    • 2018
  • The most urgent requirement in the event of disaster and fire in a skyscraper is to establish a system that enables people inside to evacuate safely. Hence, a practical direction needs to give evacuees confidence in the evacuation by reducing the psychological anxiety caused by the relatively large number of people inside and at the same time, the physically prolonged evacuation travel line. Evacuation tests with large numbers of people were conducted three times to solve these challenges and identify phenomena and issues that occurred during the experiment. The results revealed the factors that could cause a delay in evacuation and suggested improvements. The study results of this paper are as follows. First, a recent fire at a multipurpose high-rise resulted in a number of casualties due to a lack of experience with the disaster prevention system. To prevent such cases from occurring in advance, adaptability was achieved by conducting evacuation tests. Second, the data collected in the evacuation simulation statistics and the actual escape drills were compared and analyzed. Third, in the evacuation experiment, a large number of people could not participate in the experiment. The reasons for not participating were analyzed and their impact on the actual evacuation time was confirmed. Fourth, equipment aids were purchased to establish the optimal response measure to the causes of a delay in escape time and the standards for ensuring the safety of the evacuee were specified by developing improvements to minimize the evacuation delay time through comparative before and after analysis of the experiment. These results can be used for fire safety control of skyscrapers to improve the efficiency of evacuation.

A Layout Planning Optimization Model for Finishing Work (건축물 마감공사 자재 배치 최적화 모델)

  • Park, Moon-Seo;Yang, Young-Jun;Lee, Hyun-Soo;Han, Sang-Won;Ji, Sae-Hyun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.1
    • /
    • pp.43-52
    • /
    • 2011
  • Unnecessary transportation of resources are one of the major causes that adversely affect construction site work productivity. Therefore, layout related studies have been conducted with efforts to develop management technologies and techniques to minimize the resource transportation made at site-level. However, although the necessity for floor-level layout planning studies has been increasing as buildings have become larger and floors have become more complicated, studies to optimize the transportation of materials inside buildings are currently not being actively conducted. Therefore, in this study, a model was developed using genetic algorithms(GA) that will enable the optimization of the locations of finishing materials on the work-floor. With the established model, the arrangement of diverse materials on complicated floors can be planned and the optimized material layout planning derived from the model can minimize the total material transportation time spent by laborers during their working day. In addition, to calculate travel distances between work sites and materials realistically, the concept of actual travel distances was applied. To identify the applicability of the developed model and compare it with existing methodologies and analyze it, the model was applied to actual high-rise residential complexes.

Smoke Control Performance of a Serial Structure Using "CONTAM" (CONTAM을 이용한 직렬형태 구조의 제연성능 구현에 관한 연구)

  • Kim, Mi-Seon;Seo, Dong-Gil;Gu, Seon-Hwan;Yoo, Young-Min;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.53-62
    • /
    • 2019
  • A recent trend shows that more buildings are being constructed as mixed-use (residential and commercial) properties for efficient land use. This has led to an increased frequency in the occurrence of fires and the associated potential risks. In particular, in case of high-rise apartments, at least one of the elevators in each building is installed for evacuation purposes separately from the emergency elevator; therefore, for a combined ancillary room and emergency elevator platform situation, the structure is inevitably in series with the evacuation elevator platform. Thus, a proposal for a new type of ventilation zone based on existing national fire safety codes is required to achieve smoke control performance. To this end, the air egress velocity and differential pressure of each ventilation zone are checked using the "CONTAM" software; further, an alternative is proposed to secure smoke control performance for series structures.

Applied cases of advanced construction & engineering technology at Tower Palace III Project (타워팰리스 III 현장의 첨단 시공 및 엔지니어링 기술 적용사례)

  • Wang In-Soo
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.202-213
    • /
    • 2003
  • Tower Palace III project is the highest residential and commercial high-rise complex building in Korea. In order to construct a high-rise building, advanced construction and engineering technology is required. Therefore, with more developed construction and engineering technology based upon accumulated knowledge, construction speed of 13.4 days per floor including finish work was achieved in this project. To achieve this project successfully, three main advanced construction technology were applied: 1) Construction methods for 3-day cycle of structural work and curtain wall, 2) Tact scheduling method for finish work, 3) Management system of material, labor, work, and information. Also, four main engineering technology were applied: 1) New material such as high -flowing concrete and high strength concrete of 800 kgf/cm2, 2) New method such as a pipe-cooling system of a cool water circulating type, 3) Mechanical system such as smart-fan controlling kitchen-ventilation system, 4) Electrical system such as false car system.

  • PDF

Light Pollution of Outdoor Lighting in Coastal Area - Focused on Busan City - (해안가 야간경관조명의 빛공해 평가 - 부산시를 중심으로 -)

  • Kong, Hyo-Joo;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.18-26
    • /
    • 2010
  • Outdoor lighting has become a necessary essential part of society for safety and comfortable space. However, inappropriate outdoor lighting leads to energy waste and poor landscape. Outdoor lighting is a very important social element, which enables us to conduct various activities at night in a safe, efficient and comfort way. River Thames in UK, Venice in Italy and Sydney in Australia is a good example of the coastal area. This paper aims to evaluate the light pollution of outdoor lighting in coastal area in Busan city. The Radiant Imaging ProMetric-1400 was used to measure the luminance of Gwangalli Beach, Marine City and Haeundae Beach. Compare to the CIE recommendation level the luminance of the all outdoor lighting were about 2~20 times higher. Outdoor lighting of the building facade luminance level and color should be particularly limited.

An Experimental Study on the Pressure Change in the Type of Elevator Hoistways (엘리베이터 승강로 형식별 압력변동에 관한 실험 연구)

  • Kim, Hak-Joong;Kim, Boem-Gyu;Park, Yong-Hwan;Lim, Chae-Hyun
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.139-144
    • /
    • 2010
  • Recently, evacuation safety of building resident become the major concern, as the building has been higher and more complicated. Many high-rise multi use buildings are under construction in Korea. Required evacuation time using stairway is longer in high-rise buildings, moreover it is impossible for the disabled to evacuate by using stairway. For this reason the study on the effectiveness of using elevator for evacuation is progressing. This study shows the pressure change in various types of hoistway when elevator is moving. Experiments were performed in 4 different types of hoistway, and showed big difference in pressure change between the type of hoistway. The pressure change in single hoistway that have one car is bigger than that in multi hoistway that have multi cars. The results of this study can be used for the study of elevator piston effect as basic data.