• Title/Summary/Keyword: 주사장치

Search Result 276, Processing Time 0.024 seconds

The Study on Improvement of Shape Accuracy in Stereolithography (광조형법에 있어서 조형정도향상을 위한 연구)

  • Kim, Jun An;Paik, In Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.5
    • /
    • pp.15-21
    • /
    • 1997
  • In the stereolithography process, the accuracy of cured shape depends on laser power, scanning speed, scanning pattern, resin characteristics etc. When three-dimensional objects are built, higher laser power gives higher building efficiency. Normally we could control scanning speed and scanning pattern, which affect curing thickness and generate volume of curl in & after building. Olgomer, Monomer and Initiator are major components. Kinds and volume of them decide characteristic of resin. In this paper, we deal with major facts and their characteristics for precision shape building.

  • PDF

Study on the evaporation of high melting temperature metal by using the manufactured electron hem gun system (전자총 시스템 제작과 이를 이용한 고융점 금속 증발에 관한 연구)

  • 정의창;노시표;김철중
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2003
  • An axial electron beam gun system, which emits the electron beam power of 50 kW, has been manufactured. The electron beam gun consists of two parts. One is the electron beam generation part. including the filament, cathode, and anode. The maximum beam current is 2 A and the acceleration voltage is 25 kV. The other part includes the focusing-, deflection-, and scanning coils. The beam diameter and ham trajectory can be controlled by these coils. The characteristic of each part is measured ior the optimum condition of evaporation process. Moreover, Helmholtz coil is installed inside the vacuum chamber to adjust the incident angel of the beam to the melting surface for the maximum evaporation. We report on the evaporation rates for zirconium(Zr) and gadolinium(Gd) metals which have the high melting temperatures.

A Study on the Development of a Target Tracing Equipment by Remote Control for a Medical Theraphy and Diagnosis of an Ophthalmology (안과 진단 및 치료기기의 원격조정 표적 추적장치 개발에 관한 연구)

  • Eo, Y.K.;Park, H.C.;Lee, S.R.;Yang, Y.S.;Jeong, D.M.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.29-32
    • /
    • 1996
  • 기존의 안과 진단 및 치료 기기의 안구 고정장치는 진단 및 치료에 있어서 피검사자와 검사자에 사이에 충분한 협조가 되지 않을 경우 진단의 비효율성과 치료의 안정성등의 문제가 발생하고있다. 따라서 이러한 문제를 보완하기 위하여 SLO의 전면 세극등을 소형의 반사경으로 대치하고 표시등을 후면의 먼거리에 수직으로 배열시켜서 피검사자에게 적당한 높이의 고정등을 선택하게하여 수직방향의 안구 위치를 고정시키고 SLO(Scanning Laser Ophthalmoscope)의 좌우 회전기능으로 표적의 수평방향을 근절시킨 후에 검사자의 조작으로 원격조정되는 서보장치를 이용하여 다시 반사경을 전방향으로 미세하게 회전되게하여 정확한 위치로 안구를 이동시키게 하는 원격조정 표적 추적장치를 개발하였다. 이에 따라 피검사자는 거울에 비친 먼거리의 허상을 보게 되어 세극등을 이용한 근접주사방식의 단점인 안구의 축동, 폭주등으로 인한 환자의 눈의 피로를 최소화하면서 피검사자의 안구를 검사자가 원하는 위치로 고정시킬 수 있게 함으로써 임상실험에서 안과 진단의 정확성과 관리도를 높이고 치료의 효율성과 안전성을 증가시킬 수 있는 원격조정 추적장치로써의 성능을 확인하였다.

  • PDF

A Comparative Study of Production of [68Ga]PSMA-11 with or without Cassette Type Modules (비 카세트 방식과 카세트 방식을 이용한 [68Ga]PSMA-11의 자동 합성 방법 비교)

  • Hyun-Sik, Park;Byeong-Min, Jo;Hyun-Ho, An;Hong-Jin, Lee;Jin-Hyeong, Lee;Gyeong-Jae, Lee;Byung-Chul, Lee;Won-Woo, Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.15-19
    • /
    • 2022
  • Purpose [68Ga]PSMA-11 is needed the high reproducibility, excellent radiochemical yield and purity. In term of radiation safety, the radiation exposure of operator for its production also should be considered. In this work, we performed a comparative study for the fully automated synthesis of [68Ga]PSMA-11 between non-cassette type and cassette type. Materials and Methods Two different type of modules (TRACERlab FX N pro for non-cassette type and BIKBox for cassette type) were used for the automated production of [68Ga]PSMA-11. According to the previously identified elution profile, Only 2.5 ml with high radioactivity was used for the reaction. After adjusting the pH of the reaction solution with HEPES buffer solution, the precursor was added and reacted with at 95 ℃ for 15 minutes. The reaction mixture was separated and purified using a C18 light cartridge. The product was eluted with 50% EtOH/saline solution and diluted with saline. It was completed by sterilizing filter. In the non-cassette type, the aforementioned process must be prepared directly. However, in the cassette method, synthesis was possible simply by installing a kit that was already completed. Results Both total [68Ga]PSMA-11 production time were 25±3(non-cassette type) and 23±3 minutes(cassette type). The radiochemical yield of the non-cassette type(65.5±5.7%) was higher than that of the cassette type(61.6±4.8%) after sterilization filter. The non-cassette type took about 120 minutes of preparation time before synthesis due to washing of synthesizer and reagent preparation. However, since the cassette type does not require washing and reagent preparation, it took about 20 minutes to prepare before synthesis. Both type of synthesizer had a radiochemical high purity(>99%). Conclusion The non-cassette type production of [68Ga]PSMA-11 showed higher radiochemical yield and lower cost than the cassette type. However, The cassette type has an advantage in terms of preparation time, convenience, and equipment maintenance.

Nocturnal Bruxism and Botulinum Toxin Effect on the Subjects with Masseteric Hypertrophy (야간 이갈이와 교근비대 환자의 보툴리눔 독소 주사 효과)

  • Sohn, Seung-Mahn;Chung, Gi-Chung;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.3
    • /
    • pp.337-346
    • /
    • 2007
  • This study aimed to evaluate a relation of bruxism with clinical effects of botulinum toxin type A(BTX-A) injection. 5 bruxers and 5 nonbruxers with bilateral masseter hypertrophy were participated in this study. After injecting 25 unit of BTX-A(Allergen Inc, $Botox^{(R)}$) into each masseter muscle, the thickness of masseter(Mm) and anterior temporalis(Ta) muscles was measured by ultrasonography and the maximum bite force was evaluated during a 9-month period. Self-estimation on the recovery of occlusal force during mastication was done as well. Regardless of presence of bruxsim, all subjects showed significantly reduced Ms thickness(p<0.001) and maximum bite force at $1^{st}$ molars(p=0.027) with their peak at 3 months after injection, which then started to return. No significant difference was observed in Ta thickness and the bite force at the central incisors. While self-estimated occlusal force was the least at 2 weeks after injection and then rapidly returned to the baseline level with full recovery at the time of 6 to 9 months after injection, the maximum bite force measured by bite force recorder did not recover the original value, particularly in the nonbruxer group. It is assumed that nocturnal bruxism can influence recovery of atrophic masseter and decreased occlusal force due to BTX-A injection. These findings suggest a need of occlusal appliance to control bruxism or clenching habit for longer clinical effect of BTX-A injection.

Stimulation of bone formation in the expanding inter-premaxillary suture by vitamin E, in rat (백서 전상악골 봉합부 확장시 비타민 E에 의한 골형성 촉진)

  • Uysal, Tancan;Amasyali, Mihri;Olmez, Huseyin;Karslioglu, Yildirim;Gunhan, Omer
    • The korean journal of orthodontics
    • /
    • v.39 no.5
    • /
    • pp.337-347
    • /
    • 2009
  • Objective: The aim of this study was to evaluate the effects of vitamin E ($\alpha$-tocopherol) administration on bone formation in response to expansion of the inter-premaxillary suture, in rats, histomorphometrically. Methods: Thirty 50 - 60 day old Wistar rats were separated into five equal groups (one control and four experimental). All groups were subjected to inter-premaxilla expansion with 50-gram of force. Six control animals received saline solution (Group I) and three experimental groups were treated with a single dose of $\alpha$-tocopherol injected into the inter-premaxillary suture after one day after appliance placement (Group II: 2 mg/kg; Group III: 10 mg/kg; and Group IV: 50 mg/kg). A further group of six animals received three injections of 10 mg/kg $\alpha$-tocopherol, one each on days 3, 6, and 9 (Group V). Bone formation in the suture was evaluated by bone histomorphometry. Kruskal-Wallis rank and Mann-Whitney U tests were used for statistical evaluation at p < 0.05 level. Results: New bone area, bone perimeter, feret's diameter and newly formed bone measurements were significantly higher in the experimental groups than the control (p < 0.001). Bone architecture in $\alpha$-tocopherol administrated groups was improved, and bone formation during the expansion period was stimulated significantly, in a dose-dependent manner. Conclusions: The application of $\alpha$-tocopherol during the early stages to orthopedically expanded inter-premaxillary suture areas may stimulate bone formation and shorten the retention period, in rats.

Advanced LWIR Thermal Imaging System with a Large Zoom Optics (줌 광학계를 이용한 원적외선 열상장비의 설계 및 제작)

  • Hong, Seok-Min;Kim, Hyun-Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.354-360
    • /
    • 2005
  • A high performance LWIR(long wavelength infra red) zoom thermal imaging sensor using $480{\times}6$ HgCdTe(MCT) linear detector has been developed by ADD Korea. The optical system consists of zoom telescope having large objective about 190 mm diameter and optically well corrected scanning system. The zoom ratio of the telescope is 3: 1 and its magnification change is performed by moving two lens groups. And also these moving groups are used for athermalization of the system. It is certain that the zoom sensor can be used in wide operating temperature range without any degradation of the system performance. Especially, the sensor image can be displayed with the HDTV(high definition television) format of which aspect ratio is 16:9. In case of HDTV format, the scanning system is able to display 620,000 pixels. This function can make wider horizontal field of view without any loss of performance than the normal TV format image. The MRTD(minimum resolvable temperature difference) of the LWIR thermal imaging sensor shows good results below 0.04 K at spatial frequency 2 cycles/mrad and 0.23 K at spatial frequency 8 cycles/mrad at the narrow field of view.

Development of Retina Photographing and Multi Channel Image Acquisition System for Thickness Measurement of Retina (망막 두께 측정을 위한 망막 촬영 및 다채널 영상획득장치 개발)

  • 양근호
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.5 no.1
    • /
    • pp.13-17
    • /
    • 2004
  • In order to measure the retina thickness, the retina photographing system and the multi-channel high speed image data acquisition system is developed. This system requires the optical processing techniques and the high speed image processing techniques. The HeNe laser beam is projected the retina in artificial eye and then we sensed the reflected laser signal using APD array. The laser projection system on retina using optical instruments is implemented. In order to project the plane laser beam on retina, laser photographing system used the polygon mirror for horizontal scanning and the galvano mirror for vertical scanning. We acquired retina images in each channel of APD array, transferred computer using PCI interface the image data after real-time A/D converting.

  • PDF

Study on surface roughness by emanation and part angle changing at FDM (FDM 장치에서 주사량과 시제품의 경사가 표면거칠기에 미치는 영향)

  • 권광진;전재억;정진서;김광희;하만경
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.300-305
    • /
    • 2001
  • Competitive power is rapidly manufacture product required consumers. Therefore, modern industry have changed from small item many production to many item small production. rapid production is necessary thing at the product development. Thus, rapid prototyping is appeared. If the graphic model was made by CAD, the production can be made in short term. That provide what the part was directly tested by the worker. It provide believable data. This study is experiment on surface roughness of part at FDM

  • PDF