• Title/Summary/Keyword: 주사장치

Search Result 276, Processing Time 0.028 seconds

Relationship between maximum bite force and facial skeletal pattern (최대 교합력과 안면 골격 형태에 관한 연구)

  • Choi, Won-Cheul;Kim, Tae-Woo
    • The korean journal of orthodontics
    • /
    • v.33 no.6 s.101
    • /
    • pp.437-451
    • /
    • 2003
  • The purpose of this study was to measure maximum bite force and to investigate its relationship with anteroposterior, vertical, and transverse facial skeletal measurements. From among the dental students at the College of Dentistry, forty subjects (26 male and 14 female) were selected. With two sets of strain gauge, maximum bite force at the right and left first molars and anterior teeth was measured in the morning and afternoon. After taking lateral and posteroanterior cephalograms, fifty and nineteen variables were evaluated, respectively Paired t-tests and an independent t-test were done and correlation coefficients were obtained. 1. The maximum bite force at the first molars was $68.0\pm13.9kg$. in males and $55.6\pm10.5kg$ in females (p<0.05) while the force at the anterior teeth was $8.4\pm4.9kg\;and\;1.1\pm3.4kg$ respectively (p<0.05). 2. Some tendency for a greater value of maximum bite force at the preferred side was observed but not statistically significant (p>0.05). 3. Significant difference was observed between the strong bite force group and the weak bite force group in some cephalometric and other measurements (p<0.05). N-S-Ar, S-Ar-Go, FH-Hl, IMPA and MMO showed a significant difference in posterior maximum bite force (P). N-S-Ar and FH-H1 also showed a significant difference in anterior maximum bite force (A). 4. Several cephalometric variables showed some correlation with maximum bite force (p<0.05). N-S-Ar, S-Ar-Go, UGA, FH-H6, FH-H1, body weight and MMO were significantly correlated with posterior maximum bite force (P). Go-Me, P-1 and IMPA were significantly correlated with anterior maximum bite force (A).

A STUDY ON THE SHEAR BOND STRENGTH AND THE ANTICARIOGENICITY OF GLASS IONOMER CEMENT FOR BRACKET BONDING (브라켓 접착용 글라스 아이어노머 시멘트의 접착강도 및 항우식 효과에 관한 연구)

  • Kang, Yong-Joo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.3
    • /
    • pp.538-553
    • /
    • 1999
  • The purpose of this study was to compare the shear bond strength and the anticariogenicity of glass ionomer cement with conventional bonding resin and fluoride releasing resin. After the shear bond strength test, scanning electron microscopic observation was performed for the evaluation of the fracture patterns in each group. Under the polarizing light microscope, artificially induced carious lesions were evaluated and the lesion depths of the samples were measured using image analyzing program(Image-Pro $PLUS^{TM}$, USA). 50 sound maxillary premolars were used for the bond strength test and another 30 for the anticariogenic test. Data collected were analyzed statistically using Oneway-ANOVA and Scheffe test. The results were as follows: 1. Glass ionomer groups(G-III, IV, V) generally showed the lower bond strength values than resin groups(G-I, II). 2. Among the two resin groups, G-I showed the higher bond strength than G-II without statistically significant difference between them(p>.05). 3. Within glass ionomer groups, statistical significance was found between G-III and G-V with the superior bond strength in G-V (p<.05). 4. Under the SEM, adhesive failure was the predominant fracture pattern in G-I and II, whereas cohesive failures were mainly observed in G-III. In G-IV and V, mixed type of pattern where the both fracture patterns coexisted within samples could be seen. 5. In evaluation of the depth of artificially developed carious lesion, glass ionomer group showed shallower depth than resin groups with statistical significance between G-III and G-I, II(p<.05). Among resin groups, fluoride releasing resin(G-II) showed the shallower depth than conventional resin(G-I)(p<.05).

  • PDF

Effect of Concentration of Polyacrylic Acid and Sulfate ion on the Cystal growth - A Topographic Study (법랑질표면에서 폴리아크릴산용액 농도와 황산이온 농도가 결정형성에 미치는 영향)

  • Kim, Joo-Hyung;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.877-891
    • /
    • 1998
  • This study was designed to observe the effects of various concentration of polyacrylic acid containing different concentration of sulfate ion on the crystal formation on the enamel surface. Experimental crystal growth solutions were made of $10\%,\;20\%,\;30\%\;and\;40\%$ polyacrylic acid(molecular weight,5,000) solutions which containing 0.1M, 0.2M, 0.3M, 0.5M, and 1.0M sulfate ion respectively. The extracted human first bicuspid enamel surface was contacted for n seconds with these solutions, washed for 15 seconds, dried, and then the crystal topography on the enamel surface was observed under the scanning electron microscope. The crystal topography were evaluated on the SEM photographs by degree of crystal coverage, crystal length, and consistency of crystal morphology, and conclusions were as the follows. 1. Polyacrylic acid solution etched slightly the enamel surface, and the difference of etching effect by its concentration was not observed. 2. The effect of concentration of polyacrylic acid on the crystal formation was less, especially that of $20\%\~40\%$ polyacrylic acid was almost not different. 3. Concentration of the sulfate ion was a determinant factor in precipitating crystals on the enamel. The experimental crystal growth solutions containing 0.1 M sulfate ion did not make crystal formation but those containing over 0.2 M sulfate ion did. 4. The degree of crystal coverage showed a tendency to increase and then decrease according to the concentration of sulfate ion in the $20\%-40\%$ polyacrylic acid. The experimental solutions containing 0.5 M sulfate ion showed the peak of degree of crystal coverage. 5. The crystal length showed a tendency to decrease by increment of sulfate ion in the polyacrylic acid solution. 6. There was a tendency to increase the frequency of random arragement of short crystals when increasing the concentration of sulfate ion in the polyacrylic acid solution. The lower concentration of sulfate ion in the polyacrylic acid solutions tended to make spherulitic arrangement of crystals, the higher concentration of sulfate ion, the more random arrangement of crystals. The experimental solutions containing 0.5M sulfate ion showed more spherulitic arrangement than random arrangement of crystals. 7. The best one of these experimental crystal growth solutions was $30\%$ polyacrylic acid solution containing 0.5M sulfate ion.

  • PDF

Effects of heat treatment on the load-deflection properties of nickel-titanium wire (니켈-티타늄 와이어의 열처리에 따른 부하-변위 특성 변화)

  • Chang, Soo-Ho;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.36 no.5
    • /
    • pp.349-359
    • /
    • 2006
  • Objective: Nickel-titanium alloy wire possesses excellent spring-back properties, shape memory and super-elasticity. In order to adapt this wire to clinical use, it is necessary to bend as well as to control its super-elastic force. The purpose of this study is to evaluate the effects of heat treatment on the load-deflection properties and transitional temperature range (TTR) of nickel-titanium wires. Methods: Nickel-titanium wires of different diameters ($0.016"\;{\times}\;0.022"$, $0.018"\;{\times}\;0.025"$ and $0.0215"\;{\times}\;0.028"$) were used. The samples were divided into 4 groups as follows: group 4, posterior segment of archwire (24 mm) without heat treatment; group 2, posterior segment of archwire (24 mm) with heat treatment only; group 3, anterior segment with bending and heat treatment; group 4, anterior segment with bending and 1 sec over heat treatment. Three point bending test was used to evaluate the change in load-deflection curve and obtained DSC (different scanning calorimetry) to check changes in $A_f$ temperature. Results: In the three point bending test, nickel-titanium wires with heat treatment only had higher load-deflection curve and loading and unloading plateau than nickel-titanium wires without heat treatment. Nickel-titanium wires with heat treatment had lower Af temperature than nickel-titanium wires without heat treatment. Nickel-titanium wires with heat treatment and bending had higher load-deflection curve than nickel- titanium wires with heat treatment and nickel-titanium wires without heat treatment. Nickel-titanium with heat treatment of over 1 sec and bending had the highest load-deflection curve. Nickel-titanium wires with heat treatment and bending had lower Af temperature, Nickel-titanium wires with heat treatment of over Af sec and bending had the lowest Af temperature. Conclusion: From the results of this study, it can be stated that heat treatment for bending of Nickel-titanium wires does not deprive the superelastic property but can cause increased force magnitude due to a higher load-deflection curve.

Development and Performance Evaluation of an Animal SPECT System Using Philips ARGUS Gamma Camera and Pinhole Collimator (Philips ARGUS 감마카메라와 바늘구멍조준기를 이용한 소동물 SPECT 시스템의 개발 및 성능 평가)

  • Kim, Joong-Hyun;Lee, Jae-Sung;Kim, Jin-Su;Lee, Byeong-Il;Kim, Soo-Mee;Choung, In-Soon;Kim, Yu-Kyeong;Lee, Won-Woo;Kim, Sang-Eun;Chung, June-Key;Lee, Myung-Chul;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.445-455
    • /
    • 2005
  • Purpose: We developed an animal SPECT system using clinical Philips ARGUS scintillation camera and pinhole collimator with specially manufactured small apertures. In this study, we evaluated the physical characteristics of this system and biological feasibility for animal experiments. Materials and Methods: Rotating station for small animals using a step motor and operating software were developed. Pinhole inserts with small apertures (diameter of 0.5, 1.0, and 2.0 mm) were manufactured and physical parameters including planar spatial resolution and sensitivity and reconstructed resolution were measured for some apertures. In order to measure the size of the usable field of view according to the distance from the focal point, manufactured multiple line sources separated with the same distance were scanned and numbers of lines within the field of view were counted. Using a Tc-99m line source with 0.5 mm diameter and 12 mm length placed in the exact center of field of view, planar spatial resolution according to the distance was measured. Calibration factor to obtain FWHM values in 'mm' unit was calculated from the planar image of two separated line sources. Te-99m point source with i mm diameter was used for the measurement of system sensitivity. In addition, SPECT data of micro phantom with cold and hot line inserts and rat brain after intravenous injection of [I-123]FP-CIT were acquired and reconstructed using filtered back protection reconstruction algorithm for pinhole collimator. Results: Size of usable field of view was proportional to the distance from the focal point and their relationship could be fitted into a linear equation (y=1.4x+0.5, x: distance). System sensitivity and planar spatial resolution at 3 cm measured using 1.0 mm aperture was 71 cps/MBq and 1.24 mm, respectively. In the SPECT image of rat brain with [I-123]FP-CIT acquired using 1.0 mm aperture, the distribution of dopamine transporter in the striatum was well identified in each hemisphere. Conclusion: We verified that this new animal SPECT system with the Phlilps ARGUS scanner and small apertures had sufficient performance for small animal imaging.

Verification of Radiation Therapy Planning Dose Based on Electron Density Correction of CT Number: XiO Experiments (컴퓨터영상의 전자밀도보정에 근거한 치료선량확인: XiO 실험)

  • Choi Tae-Jin;Kim Jin-Hee;Kim Ok-Bae
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.105-113
    • /
    • 2006
  • This study peformed to confirm the corrected dose In different electron density materials using the superposition/FFT convolution method in radiotherapy Planning system. The experiments of the $K_2HPO_4$ diluted solution for bone substitute, Cork for lung and n-Glucose for soft tissue are very close to effective atomic number of tissue materials. The image data acquisited from the 110 KVp and 130 KVp CT scanner (Siemes, Singo emotions). The electron density was derived from the CT number (H) and adapted to planning system (Xio, CMS) for heterogeneity correction. The heterogeneity tissue phantom used for measurement dose comparison to that of delivered computer planning system. In the results, this investigations showed the CT number is highly affected in photoelectric effect in high Z materials. The electron density in a given energy spectrum showed the relation of first order as a function of H in soft tissue and bone materials, respectively. In our experiments, the ratio of electron density as a function of H was obtained the 0.001026H+1.00 in soft tissue and 0.000304H+1.07 for bone at 130 KVp spectrum and showed 0.000274H+1.10 for bone tissue in low 110 KVp. This experiments of electron density calibrations from CT number used to decide depth and length of photon transportation. The Computed superposition and FFT convolution dose showed very close to measurements within 1.0% discrepancy in homogeneous phantom for 6 and 15 MV X rays, but it showed -5.0% large discrepancy in FFT convolution for bone tissue correction of 6 MV X rays. In this experiments, the evaluated doses showed acceptable discrepancy within -1.2% of average for lung and -2.9% for bone equivalent materials with superposition method in 6 MV X rays. However the FFT convolution method showed more a large discrepancy than superposition in the low electron density medium in 6 and 15 MV X rays. As the CT number depends on energy spectrum of X rays, it should be confirm gradient of function of CT number-electron density regularly.

  • PDF

Oxide Films Formed on Hot-Dip Aluminized Steel by Plasma Electrolytic Oxidation and Their Films Growth Stages (플라즈마 전해 산화법에 의해 용융알루미늄도금 강판 상 형성한 산화층과 그 성장 과정)

  • Choe, In-Hye;Kim, Chang-Min;Park, Jun-Mu;Park, Jae-Hyeok;Hwang, Seong-Hwa;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.165-165
    • /
    • 2017
  • 지난 수 십 년 동안, 전 세계적으로 자원의 소비가 급격히 증가하게 되면서 최근 자원 고갈은 물론 환경오염이 커다란 이슈로 문제가 되고 있다. 이에 따라 재료 관련 분야에 있어서는 보다 효율적이고 친환경적인 방법으로 자원을 활용해야 된다는 필요성이 대두되었고 이와 같은 관점에서 목적하는 성분이 우수하고 환경 친화적인 표면처리 재료 개발연구가 활발하게 진행되고 있는 실정이다. 그 중 플라즈마 전해 산화(Plasma Electrolytic Oxidation, PEO)는 알루미늄, 마그네슘 등의 경금속의 경도를 향상시키고 높은 내마모성, 내식성을 갖게 하는 표면처리로써 그 관심이 증가하고 있다. 이 플라즈마 전해 산화는 일반적으로 공정비용 대비 효과적이고 환경 친화적이며 코팅 성능 면에서 우수하다고 알려져 있다. 이러한 고유한 특성으로 인해 플라즈마 전해 산화 코팅은 최근 몇 년 동안 기계, 자동차, 우주항공, 의학 및 전기 산업 등의 분야에서 그 적용이 점차 증가하고 있는 상황이다. 한편, 플라즈마 전해 산화 코팅을 하는 모재들의 경우 부동태 산화피막을 용이하게 형성할 수 있는 특성의 모재에 한정되고 있어서 그 응용확대에 한계가 있는 것이 사실이다. 따라서 본 연구에서는 플라즈마 전해 산화법을 사용하여 용융알루미늄도금 강판 상에 산화피막 형성을 시도하였다. 전원공급 장치의 양극은 전해질 속에 잠겨있는 작동전극에 연결하고 음극은 대전극 역할을 하는 스테인레스강 전해질 용기에 연결되었다. 전해질은 Sodium Aluminate 및 기타 첨가제를 함유한 것을 사용하였고 온도는 열교환기를 사용하여 $30^{\circ}C$ 이하로 유지되었다. 또한 여기서 전류밀도는 $5{\sim}10A/dm^2$, 실험 주파수는 700Hz, Duty cycle은 30 및 90%의 각 조건에서 공정처리 시간을 각각 30분 및 60분 동안 진행하였다. 이와 같은 조건에서 형성한 막들에 대해서는 주사형전자현미경(SEM)을 이용하여 코팅 막의 표면 및 단면의 모폴로지를 관찰하였음은 물론 EDS 및 XRD 측정을 통하여 원소조성분포 및 결정구조를 각각 분석하였다. 또한 이 코팅 막들에 대한 내식성은 5% 염수분무 환경 중 노출시험(Salt spray test), 3% NaCl 용액에서의 침지 시험 및 전기화학적 동전위 양극분극(Potentiodynamic Polarization) 시험을 진행하여 평가하였다. 이상의 실험결과에 의하면, 제작조건별 플라즈마 전해 산화 코팅 막의 모폴로지 및 결정구조가 상이하게 나타나는 것을 알 수 있었다. 코팅 막의 모폴로지 관찰 결과, 공정 시간에 비례하여 표면에 존재하는 원형 기공의 수는 감소하였으나 그 크기가 커지고 크레이터의 직경 또한 커진 것이 확인되었다. 이 기공은 마이크로 방전에 의해 형성된다고 알려져 있는데 공정 시간이 증가함에 따라 코팅 두께가 점차 증가하여 마이크로 방전의 빈도수가 줄어들고 그 강도는 증가하게 되어 기공 크기가 증가한 것으로 사료된다. 또한 공정시간이 긴 시편에서 표면에 크랙이 다수 존재하는 것으로 확인되었다. 이것은 방전에 의해 고온이 된 소재가 차가운 전해질과 만나게 되어 생긴 큰 온도구배로 인해 강한 열응력이 발생하여 균열을 초래한 것으로 보인다. 조성원소 분석 결과 원형 기공 주변의 크레이터 영역에는 알루미늄이 풍부하였으며 그 주변에 결절상을 갖는 구조에서는 전해질 성분의 원소가 포함되어 있는 것이 확인되었다. 이러한 코팅 막의 표면 특성은 내식성에 영향을 주게 된 원인으로 사료된다. 동전위 분극측정 결과에 의하면 플라즈마 전해 산화 공정 시간이 길어질수록 부식전류밀도가 증가하였다. 이것은 공정시간이 길어짐에 따라 강한 방전이 발생하여 기공의 크기가 증가하고 크랙이 발생하게 되면서 내식성이 저하된 것으로 판단된다. 종합적으로 재료특성 분석 및 내식성 평가를 분석한 결과, 플라즈마 전해 산화의 공정 시간이 너무 길게 되면 오히려 내식성은 저하되는 것이 확인되었다. 이상의 연구를 통하여 고내식 특성을 갖는 플라즈마 전해 산화 막의 유효성을 확인하였으며 용융알루미늄강판 상에 실시한 플라즈마 전해 산화 처리에 대한 기초적인 응용 지침을 제시할 수 있을 것으로 사료된다.

  • PDF

Assessment of Quantitative Analysis Methods for Lung F-18-Fluorodeoxyglucose PET (폐 종양 FDG PET 영상의 다양한 추적자 역학 분석 방법 개발과 유용성 고찰)

  • Kim, Joon-Young;Choi, Yong;Choi, Joon-Young;Lee, Kyung-Han;Kim, Sang-Eun;Choe, Yearn-Seong;Kim, Yong-Jin;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.332-343
    • /
    • 1998
  • Purpose: The purpose of this study was to assess the diagnostic accuracy of various quantitation methods using F-18-fluorodeoxyglucose (FDG) in patients with malignant or benign lung lesion. Materials and Methods: 22 patients (13 malignant including 5 bronchoalverolar cell cancer; 9 benign lesions including 1 hamartoma and 8 active inflammation) were studied after overnight fasting. We performed dynamic PET imaging for 56 min after injection of 370 MBq (10 mCi) of FDG. Standardized uptake values normalized to patient's body weight and plasma glucose concentration (SUVglu) were calculated. The uptake rate constant of FDG and glucose metabolic rate were quantified using Patlak graphical analysis (Kpat and MRpat), three compartment-five parameter model (K5p, MR5p), and six parameter model taking into account heterogeneity of tumor tissue (K6p, MR6p). Areas under receiver operating characteristic curves (ROC) were calculated for each method. Results: There was no significant difference of rate constant or glucose metabolic rate measured by various quantitation methods between malignant and benign lesions. The area under ROC curve were 0.73 for SUVglu, 0.66 for Kpat, 0.77 for MRpat, 0.71 for K5p, 0.73 for MR5p, 0.70 for K6p, and 0.78 for MR6p. No significant difference of area under the ROC curve between these methods was observed except the area between Kpat vs. MRpat (p<0.05). Conclusion: Quantitative methods did not improve diagnostic accuracy in comparison with nonkinetic methods. However, the clinical utility of these methods needs to be evaluated further in patients with low pretest likelihood of active inflammation or bronchoalveolar cell carcinoma.

  • PDF

A LIGHT AND ELECTRON MICROSCOPIC STUDY OF CHANCES IN INTERMAXILLARY SUTURE DURING THE RAPID MAXILLARY EXPANSION OF YOUNG ADULT DOGS (유성견 급속정중이개시 정중구개봉합부위의 조직학적 변화에 대한 연구)

  • Lee, Doo-Hee;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.26 no.2 s.55
    • /
    • pp.153-162
    • /
    • 1996
  • Rapid maxillary expansion is widely used for the correction of anteroposterior discrepancies, constriction of the maxillary arch, etc. This experiment was undertaken to examine the serial changes in the osteogenesis as well as the collagen fiber bundles in the intermaxillary suture during the rapid maxillary expansion treatment. Four young female dogs aged 6 to 8 months old and not showing menarche yet were used for the experiment. The maxillary impression of dogs were taken, expansion device cast and Hyrax screw soldered at the midline in the 1st premolar area. RME device was delivered to the dogs and the activation of 0.25 mm per quarter-turn was done 2 times per day for 10 days until 5 mm separation was made. Separation of the maxilla was confirmed by X-ray. The animals were sacrificed on 0, 15, 30, 60 days from the finish of maxillary separation and preparations for light microscopy and surface electron microscopy were made. The sutures were cut into frontal serial sections for examination of the histological reactions. The following results were obtained and the conclusions made. 1. The edges of the two palatal plates bordering the midpalatal suture which at the beginning of the retention period were mainly composed of compact bone, underwent extensive resorption followed by new bone formation and gradually became spongy bone rich in bone marrow which in the 60 day retention animal became the compact bone with short intermaxillary suture space. During this transformation, newly formed trabecular bone tissues were added to the original margin. 2. Throughout the expansion period, the collagen fibers underwent successive changes such as stretching, loss of polarity, and finally fibrillogenesis. Towards the end of the expansion procedure, sharpey's fiber formation in newly formed bones were observed. 3. Bony spicules were found in the initial stage of retention on occlusal topographic X-rays, which later were confirmed to have ossified. 4. Judging from the histological changes occuring during the experimental expansion, excessive expansion will cause an excessive bleeding, and retard the remodeling of intermaxillary suture. According to the above results, the bone remodeling after rapid maxillary expansion was preceded by the migration of migratory cells into the intermaxillary suture area. The bone remodeling phenomena were on-going during the 2 months retention sample.

  • PDF

Effects of chromium chloride addition on coloration and mechanical properties of 3Y-TZP (크롬염화물 첨가에 따른 지르코니아 색상 및 물리적 성질 변화에 관한 연구)

  • Oh, Gye-Jeong;Seo, Yoon-Jeong;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sang-Won;Lee, Kyung-Ku;Lim, Tae-Kwan;Lee, Doh-Jae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.120-127
    • /
    • 2011
  • Purpose: The purpose of this study was to examine the effects of chromium chloride addition on coloration, mechanical property and microstructure of 3Y-TZP. Materials and methods: Chromium chloride was weighed as 0.06, 0.12, and 0.25 wt% and each measured amount was dissolved in alcohol. $ZrO_2$ powder was mixed with each of the individual slurry to prepare chromium doped zirconia specimen. The color, physical properties and microstructure were observed after the zirconia specimen were sintered at $1450^{\circ}C$. In order to evaluate the color, spectrophotometer was used to analyze the value of $L^*$, $C^*$, $a^*$ and $b^*$, after placing the specimen on a white plate, and measured according to the International Commission on Illumination (CIE) standard, Illuminant D65 and SCE system. The density was measured in the Archimedes method, while microstructures were evaluated by using the scanning electron microscopy (SEM) and XRD. Fracture toughness was calculated Vickers indentation method and indentation size was measured by using the optical microscope. The data were analyzed with 1-way ANOVA test (${\alpha}$ = 0.05). The Tukey multiple comparison test was used for post hocanalysis. Results: 1. Chromium chloride rendered zirconia a brownish color. While chromium chloride content was increased, the color of zirconia was changed from brownish to brownish-red. 2. Chromium chloride content was increased; density of the specimen was decreased. 3. More chromium chloride in the ratio showed increase size of grains. 4. But the addition of chromium chloride did not affect the crystal phase of zirconia, and all specimens showed tetragonal phase. 5. The chromium chloride in zirconia did not showed statistically significant difference in fracture toughness, but addition of 0.25 wt% showed a statistically significant difference (P<.05). Conclusion: Based on the above results, this study suggests that chromium chlorides can make colored zirconia while adding in a liquid form. The new colored zirconia showed a slight difference in color to that of the natural tooth, nevertheless this material can be used as an all ceramic core material.