• Title/Summary/Keyword: 주사장치

Search Result 276, Processing Time 0.027 seconds

Position Control Technique of Ultrasonic Scanner for an Automated Ultrasonic Testing Using Surface Wave (표면파를 이용한 자동 초음파탐상검사 주사장치의 위치제어 기술)

  • Lee, Jong-Po;Park, Chul-Hoon;Um, Byong-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.1
    • /
    • pp.30-37
    • /
    • 2003
  • In order to replace the manual ultrasonic testing(UT) with an automated UT(AUT), a scanner which enables us to control the positions of a transducer is essential. Encoders have been commonly used to obtain the position information from the conventional scanners controlled by motor. Encoders have various advantages in many aspects. However, if the slip of motor wheel occurs during scanning, various errors are involved in the position accuracy. Thus, the position information of encoders becomes meaningless in case of slip. The reliability of AUT results nay become serious problem. Hence, slip must be avoided, but it can not be completely avoided at present time. In this paper, a new idea that surface wave is used to solve this problem and replace encoders has been proposed. It is shown that this idea can be employed in AUT scanner without encoders. That is, one transducer transmitting surface wave is fixed and the other transducer attached to the scanner receives UT signal. Then, computer calculates the present position of scanner based on the information given by surface wave. Thus, the movement of a scanner can be controlled by the amount of input based on the information obtained.

Laser Scanner Using Computer Generated Hologram (전자계산기 프로그램을 이용한 레이저 주사장치)

  • Yun, Hui-Cheol;Lee, Jong-Chang;Sin, Sang-Yeong
    • Proceedings of the KIEE Conference
    • /
    • 1984.07a
    • /
    • pp.302-305
    • /
    • 1984
  • 전자계산기 홀로그램을 이용한 Over-filled 주사장치를 구성하고 주사특성을 측정하였다. 그 결과 주사거리는 40cm 정도이고, $100{\mu}m$ 정도의 해상도를 가지며, 회전면의 흔들림에 대해서도 안정함을 보여 주었다.

  • PDF

업계소식

  • Korea Electronics Association
    • Journal of Korean Electronics
    • /
    • v.12 no.3
    • /
    • pp.88-92
    • /
    • 1992
  • PDF

Development of Hybrid Fused Deposition Modeling System for Three-Dimensional Circuit Device Fabrication (3 차원 회로 장치 제작을 위한 FDM 기반의 통합 시스템 개발)

  • O, Sung Taek;Lee, In Hwan;Kim, Ho-Chan;Cho, Hae Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.8
    • /
    • pp.869-874
    • /
    • 2014
  • It is possible to fabricate a three-dimensional (3D) shape using the solid freeform fabrication (SFF) technology. However, there are several problems in applying conventional SFF technologies to the direct manufacturing of a product. Hence, multimaterial SFF is gaining attention. Moreover, a 3D circuit device that is different from a conventional two-dimensional PCB can also be fabricated using multimaterial SFF. In this study, a hybrid system using fused deposition modeling and direct writing was designed for 3D circuit device fabrication.

Effect of Botulinum Toxin type A and Occlusal Splint on Masseter Muscle Evaluated with Computed Tomographic Measurement (전산화 단층촬영으로 평가한 교근에 대한 보툴리눔 A형 독소주사와 교합안정장치의 효과)

  • Jang, Hee-Young;Kang, Seung-Chul;Kim, Seong-Taek;Kim, Chong-Youl;Choi, Jong-Hoon
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.2
    • /
    • pp.247-255
    • /
    • 2005
  • The purpose of this study is to evaluate the effect of botulinum toxin type A on masseter muscle atrophy and the extent of masseter muscle affected from the injection site in relation to injection dose, with and without occlusal splint therapy through computed tomographic measurement. 32 volunteers were divided into four groups - group 25U (injection dose of 25 unit), group 25Us (injection dose of 25 unit with occlusal splint), group 35U (injection dose of 35 unit), group 35Us (injection dose of 35 unit with occlusal splint). Each group consisted of 8 people. 3 positions (position 1, 2, 3 - 10mm, 20mm and 40mm from the inferior border of the mandible, respectively) were selected for the evaluation of the masseter muscle change. The following results were obtained. 1. The thickness and the cross-sectional area of the masseter muscle had reduced in all groups except for the right side thickness at position 3 of group 25U and group 25Us, and the right side thickness as well as the left side cross-sectional area at position 3 of group 35Us. In group 35Us, the thickness and the cross-sectional area of the masseter muscle had reduced significantly in all positions (P < 0.05). 2. There was no significant difference in the masseter muscle change between the injection dose of 25unit and that of 35unit. 3. The groups with occlusal splint showed greater reduction of the masseter muscle thickness than the other groups (P < 0.05). From the above results, botulinum toxin type A injection together with occlusal splint therapy in the treatment of masseter muscle hypertrophy would be clinically effective.

레이저 기입 광학계용 광학 장치의 계측

  • Korea Optical Industry Association
    • The Optical Journal
    • /
    • s.104
    • /
    • pp.59-69
    • /
    • 2006
  • 레이저 프린터나 디지털 복합기(MFP:MultiFunction Peripheral)에 탑재되는 레이저 기입 광 학계에는 주사 광학 소자(fθ렌즈, fθ미러)나 폴리곤 스캐너라는 광학 장치가 사용되고 있다. 본 고에서는 레이저 기입 광학계에 사용되는 광학 장치를 중심으로, 이들을 대상 으로 하는 최근의 계측 기술을 설명하면서 2020년을 향한 향후의 전망에 대하여 설명하 기로 한다.

  • PDF

Endoscopic Imaging and Fabrication of Micro-endoscope Catheter in Time-domain Optical Coherence Tomography (시간영역 광 간섭 단층촬영 시스템의 소형 엔도스코프 제작 및 영상구현)

  • Kim, Young-Kwan;Lee, Sung-Hun;Kim, Yong-Pyung
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.5
    • /
    • pp.206-213
    • /
    • 2010
  • We fabricated and characterized a compact endoscopic catheter for optical coherence tomography. The optical delay line (ODL), composed of a cylindrical piezoelectric transducer (PZT) and an optical fiber, was operated with a 1 kHz sinusoidal driving wave in the time-domain. When the ODL was driven with a sinusoidal wave function, the axial scanning speed was 6 m/s and the axial acquisition rate was 2000 line/s at a depth of about 3 mm. Endoscopic OCT images of a human finger and earhole were successfully obtained with an image rate of ten frames per second.

A Study on the Usefulness of Auto Dispenser and Optimized Dispensing Method (방사성 의약품 자동 분주장치의 유용성 및 최적화된 분주방법에 관한 고찰)

  • Lee, JeoungEun;Kim, Hosung;Ryu, Jaekwang;Jung, Wooyoung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.59-66
    • /
    • 2013
  • Purpose: Recently, there is an increase of the number of hospitals using auto dispenser to reduce occupational radiation exposure when drawing up of the $^{18}F-FDG$ dose (5.18 MBq/kg) in a syringe from the dramatic high activity of $^{18}F-FDG$ multidose vial. The aim of this study is to confirm that using auto dispenser actually reduces the radiation exposure for technologists. Also we analyzed the reproducibility of auto dispenser to find optimized dispensing method for the device. Materials and Methods: We conducted three experiments. Comparison of radiation exposure on chest and hands: The chest and hands exposure dose received by technologists during the injection were measured by electronic personal dosimeter (EPD) and ring TLD respectively. Reproducibility of dispensed volume: We draw up the normal saline into 5 and 2 mL syringe using auto dispenser by changing the volume from 1 to 15 mm for 5 times in the same setting of the volume. The weight of 5 normal saline dispensed from the device at same volume was measured using micro balance and calculated standard deviation and coefficient of variation. Reproducibility of dispensed radioactivity: We dispensed 362.6 $MBq{\pm}10%$ of $^{18}F-FDG$ in 5 and 2 mL syringes from the multidose vial of different specific activity. In the same setting of volume, we repeated dispensing for 4 times and compared standard deviation and coefficient of variation of radioactivity between 5 syringes. Results: There was significant difference in the average of chest exposure dose according to the dispensing methods (P<0.05). Also, when dispensing $^{18}F-FDG$ in manual method, exposure dose was 11.5 times higher in right hand and 4.8 times higher in left hand than in auto method. In the result of reproducibility of dispensed volume, standard deviation and coefficient of variation shows decline as the dispensing volume increases. As a result of reproducibility of dispensed radioactivity, standard deviation and coefficient of variation increases as the specific activity increases. Conclusion: We approved that the occupational radiation exposure dose of technologists were reduced when dispensing $^{18}F-FDG$ using auto dose dispenser. Secondly, using small syringes helps to increase reproducibility of auto dose dispense. And also, if you lower the specific activity of $^{18}F-FDG$ in multidose vial below 915-1,020 MBq/mL, you can use auto dispenser more effectively keeping the coefficient of variation lower than 10%.

  • PDF