• Title/Summary/Keyword: 주간 하늘

Search Result 8, Processing Time 0.024 seconds

Star Detectability Analysis of Daytime Star Sensor (주간 활용 별센서의 별 감지가능성 분석)

  • Nah, Ja-Kyoung;Yi, Yu;Kim, Yong-Ha
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.9
    • /
    • pp.89-96
    • /
    • 2005
  • This paper discusses the daytime atmospheric conditions and the possibility of daytime star detection with the purpose of practical use of the star sensor for daylight navigation. In order to estimate the daytime atmospheric data, we use the standard atmospheric model (LOWTRAN 7), from which atmospheric transmittance and radiance from background sky are calculated. Assuming the star sensor with an optical filter to reduce background radiation, different separation angles between the star sensor and the sun are set up to express the effect of the solar radiation. As considerations of field of view (FOV) of the star sensor, the variation of the sky background radiation and the star density of the detectable star are analyzed. In addition, the integration time to achieve a required signal-to-noise ratio and the number of the radiation-caused electrons of the charge coupled detector(CCD) working as the limit to daylight application of the star sensor are calculated.

Radiant Cooling by the Plate Viewing the Daytime Sky (주간 하늘에 노출된 평판에 의한 복사냉각 실험)

  • Byun, Ki-Hong
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.11-17
    • /
    • 2007
  • The purpose of this study is to check whether the plate temperature could be lower than the surrounding air by using the radiant cooling during the day time in summer at Seoul. Without an insolation shield as this experiment was performed, a few cases were found. The temperatures of the black painted plate are lower than those of the aluminium film coated plate if the following condition exist; no or small insolation over the plate, the wind velocity less than around 2 m/s, and clear sky However if there are insolation over the plate, the temperatures of the aluminium coated plate are lower than the black painted plate. Also, as the wind velocity increases, the plate temperature decreases faster. The temperature response of the small system is much faster than the large system.

Luminous Characteristics of Urban Street Between Day and Night (도시가로의 주.야간 빛환경 특성 분석에 관한 연구)

  • Shim, In-Bo;Kim, Bong-Kyun;Kim, Jeong-Tai
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.194-201
    • /
    • 2005
  • 도시에서의 빛의 연출은 도시의 축을 부각시키고, 가로의 아이덴티티를 연출함으로서 도시의 인지도를 향상시킬 수 있다. 또한 야간의 경관은 인공조명을 이용한 빛의 연출로 주간과는 다른 빛환경 경관을 연출할 수 있다. 이에 본 연구는 도시 가로 중에서 상업가로와 주거가로를 대상으로 주 야간의 빛환경 특성을 분석하여, 가로의 용도에 따른 주야간의 빛환경 차이를 고찰하였다. 이를 위하여 두 가로의 일정길이에 대하여 수평면조도, 스칼라 조도, 휘도 및 색온도를 측정하였으며 측정결과를 용도별, 주 야별로 비교하여 분석하였다. 측정한 결과를 정리하면 다음과 같다. (1)수평면조도의 측정 결과, 주간의 주거가로에 비하여 상업가로가 28.8[%] 높게 나타났으며 야간의 경우 87.2[%] 높게 나타났다. (2) 스칼라조도의 측정결과, 스칼라조도의 특성상 전반적으로 균일한 분포를 보이며, 수평면 조도와 마찬가지로 주간에 비하여 야간에 84[%] 높은 값이 측정되었다. (3) 휘도의 측정 결과, 주간 배경에 대한 대상의 휘도비는 상업과 주거가로가 1:2이하로 나타나 조화로운 가로경관을 연출하며, 야간배경에 대한 대상의 휘도비는 상업가로는 1:17로 활기 있는 경관을 연출하고 주거가로는 1:5로 가로경관 이미지에 적당한 강조효과가 나타났다. (4) 색온도의 측정 결과, 주간의 배경은 맑은 하늘의 색온도를 나타냈으며 대상은 상쾌하고 활동적인 이미지의 색온도를 나타내었다. 또한 야간의 경우 상업가로와 주거가로 모두 나트륨 등의 영향을 받아 전반적으로 따뜻한 느낌의 색온도가 연출되었다.

  • PDF

Distribution of Root System and Several Chemical Components of Soil on Low-Cutting Mulberry Field (낮추베기 뽕나무 뿌리와 몇몇 토양화학성 분포에 관한 조사연구)

  • 이원주
    • Journal of Sericultural and Entomological Science
    • /
    • v.22 no.1
    • /
    • pp.52-58
    • /
    • 1980
  • Root system and distribution of soil components (pH, available P, K, Ca and Mg) were studied in a 20-year old, low-cutting mulberry field. The variety, kairyonezumigaeshi (Morus alba L.), was planted in a spacing of 1.8m${\times}$0.6m(740 tiess/10a). Roots and soil samples were taken from each of 196 blocks in a demension of 26${\times}$17${\times}$10cm(as shown in Fig. 1) from the soil between rows. 1. Whereas root system concentrated towards the stock, chemical components, pH, available P, Ca and Mg, were increasing toward the center of the row spacing. 2. Root system and distribution of chemical components between trees were not significantly different among blocks. 3. Roots were distributed most densely in a depth of 10∼20, intermediate 20∼30 and 30∼40, and least 0∼10cm. However, the concentrbtion of chemical components was the highest in a depth of 0∼10cm and decreased with soil depth. The soil. a depth of 0∼10cm on the center of row spacing, was the lowest in the root system and the richest in a chemical components. The results indicate that special fertilizinng management is required for the efficient absorption of nutrients.

  • PDF

Performance Test of the Boltwood Cloud Sensor for the Meteorological Condition of Optical Satellite Observation (위성 광학관측 가능 기상상태 판단을 위한 Boltwood 구름센서 성능 시험)

  • Bae, Youngho;Yoon, Joh-Na;Jo, Jung Hyun;Moon, Hong-Kyu;Choi, Young-Jun;Yim, Hong-Suh;Park, Youngsik;Park, Sun-Youp;Park, Jang-Hyun;Choi, Jin;Kim, Myung-Jin;Kim, Jihye
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.3
    • /
    • pp.32-40
    • /
    • 2013
  • The Boltwood Cloud Sensor is meteorological sensor that is used to estimate an amount of clouds in the sky. This sensor will be installed for OWL(Optical Wide-field patroL) telescope and observatory system of Korea Astronomy and Space Science. Before applying this sensor to an observatory system, we performed test observations at Chungbuk University Observatory at Jincheon, Chungbuk. During the test run, a significant correlation between air temperature difference and the number of visible stars recorded in the CCD frames has not been found. This preliminary result can be attributed to test environment of the observation and our lack of knowledge on calculation algorithm as well as the hardware system of the Boltwood Cloud Sensor.In this paper, we present the procedure and the result of the performance test employing the cloud sensor.

Effects of Hot Water and Chilling Treatments of Bulblets Propagated by Tissue Culture on Sprouting and Bulb Development in Korean Native Lilies (조직배양 유래 자생나리 소인경의 온탕 및 저온처리가 맹아 및 비대에 미치는 효과)

  • Kim, Min-Hui;Lim, Young-Hee;Oh, Wook;Yun, Hae-Keun;Kim, Kiu-Weon
    • Horticultural Science & Technology
    • /
    • v.29 no.2
    • /
    • pp.87-94
    • /
    • 2011
  • This study was carried out to investigate the effects of hot solution soaking and chilling treatment on sprouting and enlargement of bulblets obtained through in vitro culture in Korean native lilies with ornamental values. In vitro bulblets of Lilium cernuum, L. hansonii, L. hansonii for. mutatum, L. leichtlinii, and L. tsingtauense were soaked in distilled water or 100 $mg{\cdot}L^{-1}$ $GA_3$ and $GA_{4+7}$ solution maintained at $35^{\circ}C$ for two hours (hot water treatment) and/or exposed at $4^{\circ}C$ for 0, 4, or 8 weeks (chilling treatment) and then planted in plastic trays filled with media and grown in a greenhouse at $20^{\circ}C$ and under 16 h photoperiod. In all species, no bulblet propagated by tissue culture sprouted without chilling or hot water treatment due to dormancy. For dormancy breaking, $GA_{4+7}$ hot solution treatment increasing sprouting by 55-96%, whereas distilled water or GA was not effective in sprouting. Chilling treatment for 4 weeks induced sprouting by 50-70% in L. cernuum and L. leichtlinii, whereas 8 weeks was needed for sprouting of L. hansonii and L. hansonii for. mutatum. Combined treatment of hot water and chilling treatments synergistically promoted sprouting. Especially, in L. cernuum and L. hansonii, $GA_{4+7}$ hot solution soaking prior to chilling for 4 weeks promoted sprouting by 35-45% compared with the reverse order. Enlargement of bulblets resulted from increase in fresh weight and diameter was promoted by the treatments that increased the sprouting percentage of bulblets. Only in L. cernuum, shoots emerged from bulblets soaked in hot $GA_{4+7}$ solution or chilled at $4^{\circ}C$ and shoot emergence rate was highest in bulblets soaked in hot $GA_{4+7}$ solution and then chilled for 8 weeks. From these results, the most effective method for bulblet sprouting and enlargement was to soak in hot $GA_{4+7}$ solution and then chill for 4 weeks in L. hansonii, hansonii for. mutatum, and leichtlinii, and to soak in hot $GA_{4+7}$ solution and then chill for 4 weeks in L. cernuum and tsingtauense.

Seasonal Fluctuation, Reproduction, Development and Damaging Behavior of Compsidia populnea L.(Coleoptera; Cerambicidae) on Populus $alba{\times}glandulosa$ (현사시나무의 줄기 식입해충(害蟲) 포푸라하늘소의 생활사(生活史)에 관한 조사(調査))

  • Park, Kyu-Tek;Paik, Hung-Ryul
    • Korean journal of applied entomology
    • /
    • v.24 no.4 s.65
    • /
    • pp.195-201
    • /
    • 1986
  • This study was conducted to investigate the life history of Compsidia populnea which is major species of the stem-borers on Populus alba{\times}glandulosa$. Peak emergence of the adult of Compsidia populnea L. was around 10th${\sim}$l2nd of May in Chuncheon vicinities, having one generation a year in Korea. There was a preovipositional period of 10.7 days and a ovipositional period of 14.3.days. Mean adult longevity was 11 days for male and 13.8 days for female. Individual eggs were long oval with somewhat narrowed tip at one side and soft, 2.6mm in length, 0.8mm in diameter, and were laid singly under the U-shaped scars which were made by female before oviposition. Total number of scars per female averaged 56.6 ($8{\sim}135$) and eggs were found in 67.9 percent of the total scars. Egg period was $8{\sim}11$ days at $25^{\circ}C$ constant temperature and $7{\sim}14$ days in the field condition. Early young larvae stayed for $2{\sim}3$ weeks under the scars and then boring into the xylem, forming galls at this time. Size of the gall was 1.8cm($1.3{\sim}2.5$) in length, 1.6cm($1.0{\sim}2.2$) in diameter and the length of mine was everage 3.1cm. Fully grown larvae were developed around the early October and overwintered in the mines of galls. Pupation was done around the early of April. Pupal developmental period averaged 11 days($9{\sim}13$ days) at $25^{\circ}C$ constant temperature condition.

  • PDF

Estimation of the Required Number of Fan Coil Unit for Surplus Solar Energy Recovery of Greenhouse (온실의 잉여 태양에너지 회수용 FCU 소요대수 검토)

  • Yun, Sung-Wook;Choi, Man Kwon;Kim, Ha Neul;Kang, Donghyeon;Lee, Siyoung;Son, Jinkwan;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.83-88
    • /
    • 2016
  • In this study, previously reported surplus solar energy-related study result and current status of fan coil unit (FCU) for cooling and heating installed in the current sites were briefly examined and then a method to determine the number of FCUs required to recover surplus solar energy was schematically proposed to provide basic data for researchers and technical engineers in this field. The maximum, mean, and minimum outside temperatures during the experiment period were about $28.2^{\circ}C$, $4.4^{\circ}C$, and $-11.5^{\circ}C$, respectively. The horizontal surface solar radiation level outside the greenhouse was in a range of $0.8-20.5MJ{\cdot}m^{-2}$ and mean and total solar radiation were $10.8MJ{\cdot}m^{-2}$ and $1,187.5MJ{\cdot}m^{-2}$. The mean temperature and relative humidity in the greenhouse during the daytime were in a range of 18.8-45.5 and 53.5-77.5%. The total surplus solar energy recovered from the greenhouse during the experiment period was approximately 6,613.4MJ, which could supplement about 6.7% of the total heating energy 98,600.2 MJ. In addition, the number of FCUs installed for heating varies case to case, although similar FCUs are used. Thus, it is necessary to study the installation height, orientation and installation distance as well as the appropriate number of FCUs from the efficient and economical viewpoints. The required numbers of FCUs for surplus solar energy recovery were 8.4-10.9units and 6.1-8.0units based on air mass and circular flow rate that passed through the FCUs. Considering calculation methods and the risks such as efficiency and use environments of FCUs, it was found that about nine units (one unit per $24m^3$ approximately) needed to be installed. The required number of FCUs for surplus solar energy recovery was around one unit per $24m^3$ approximately.