• Title/Summary/Keyword: 좌심실 기능

Search Result 214, Processing Time 0.033 seconds

Surgical Treatment of a Submitral Left Ventricular Aneurysm and the Patient Present with Recurrent Ventricular Tachycardia (재발성 심실성 빈맥이 동반된 승모판하 좌심실류의 외과적 치료)

  • Kim, Young-Sam;Cho, Jung-Soo;Yoon, Yong-Han;Kim, Joung-Taek;Baek, Wan-Ki;Kim, Kwang-Ho
    • Journal of Chest Surgery
    • /
    • v.43 no.2
    • /
    • pp.180-183
    • /
    • 2010
  • Submitral left ventricular aneurysm (SMLVA) is a rare disease entity that exclusively occurs in the black population. We herewith report on a surgical case of SMLVA in a 68-year-old male who presented with ventricular tachycardia. He underwent surgical repair under standard hypothermic cardiopulmonary bypass. In the state of apical elevation, a vertical ventriculotomy was made directly over the aneurysm, which was located at the posterobasal aspect of the left ventricle. Radiofrequency ablation was performed on the endocardium all around the neck of the aneurysm and then patch endoaneurysmorrhaphy was carried out with particular care not to injure the mitral valve and subvalvular structure. His postoperative recovery was uneventful. There has been no dysfunction of the mitral valve or recurrence of the ventricular tachycardia at 2 years' follow-up.

Postcardiotomy Ventricular Assist Device (개심술후 심실 보조장치)

  • 나찬영
    • Journal of Chest Surgery
    • /
    • v.27 no.5
    • /
    • pp.390-393
    • /
    • 1994
  • 의료기술의 발달로 오늘날의 개심술은 대부분 성공적으로 시행되고 있지만 극히 일부분은 아직도 개심술후 심한 심실기능의 저하로 사망하는 겨우가 있다. 1960년대 중반 Spencer와 DeBakey에 의해 개심술후 심한 심실기능이 저하된 환자에게 심실보조장치를 이용하여 성공적으로 치험한 이후로 많은 발전을 거듭해 왔다. 저자들은 4개월 (6.5Kg)된 남아에서 개심술후 심한 저심박출증으로 인공심폐기의 제거를 못하여 좌심실 보조장치(Centrifugal Biopump)를 사용하여 성공적으로 치험하였기에 보고하는 바이다.

  • PDF

An Animal Study on Electrohydraulic Type Ventricular Assist Device (전기 유압식 심실보조장치의 동물실험 연구)

  • 백완기;심상석
    • Journal of Chest Surgery
    • /
    • v.29 no.7
    • /
    • pp.689-699
    • /
    • 1996
  • An animal experiment was designed for the evaluation of in vivo performance of the newly developed electrohydraulic type ventricular assist device and its influence on the left ventricular function during pal- satile left ventricular assist. Eight adult sheep were incorporated into the study and data were collected from seven sheep. Total as- sist time ranged from 69 minutes to 7 days. The performance of the device was satisfactory both in asyn- chr nous and synchronous mode within the range of given native heart rate. More than 4 liters of device output could be reached within the range of normal left atral pressure without development of negative pressure in the left atrium. Moderate to severe degree of hemolysis was noted as evidenced by significant increase of plasma free hemoglobin level after 3 days of left ventricular support along with the presence of the small amount of thrombi around the floating disc type polymer valve apparatus reflecting that further study and refinement of the device need to be done in regard of biocompatibility and thromboresistance. The hemodynamics showed increase in heart rate (p < 0.05), cardiac output and left ventricular minute work (p < 0.05) after placement of the device at the flow rate of 2.0∼2.5 Llmin. The left atrial pressure, left ventricular pressure and LV dpldt were decreased after the device placement(p < 0.05). The endocardial viability ratio and oxygen contents of the mixed ven us blood and coronary venous blood were all increased (p < 0.05) after the device placement suggesting effective unloading of the left ventricle was accomplished. The myocardial perfusion was thought improved in synchronous counterpulsation as suggested by sig- nificant increase in endocardial viability ratio and coronary venous blood oxygen content in synchronous assist mode comparing with asynchronous mode.

  • PDF

The Relationship of the LV Systolic Function, the LV Dimension and the LV Mass to QT Dispersion in Stable Angina Patients who are with or without Significant Coronary Stenosis (안정성협심증 환자에서 저명한 관상동맥 협착 유무와 좌심실 수축기능, 용적, 질량과 QT Dispersion 간의 관계)

  • Kwon, Jong-Bum;Yoon, Hee-Jeoung;Jin, Seung-Won;Her, Sung-Ho;Kim, Hyung-Doo;Kim, Kyung-Soo;Lee, Jong-Ho;Park, Khun
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.439-446
    • /
    • 2008
  • Background: The aim of this study was to investigate the relationship of the left ventricular (LV) systolic function, the LV dimension and the LV mass with the QT dispersion in patients with stable angina, and we also wanted to compare this relationship between patients with and without significant coronary stenosis on coronary angiography. Material and Method: 174 patients complained of typical angina and they had no associated ST segment or cardiac enzyme abnormalities. The patients were divided into 2 groups based on the results of coronary angiography: the patients with angiographic coronary stenosis ${\geq}50%$ made up group I (n=101), and the patients with angiographic coronary stenosis <50% made up group II (n=73). An echocardiogram for assessing the LV ejection fraction (EF), the LV dimension and the LV mass and a 12.lead electrocardiogram for assessing the QT dispersion were performed before the coronary angiography. Result: The QT dispersion was significantly greater in group I than that in group II (39.8 ms vs. 33.3 ms; p<0.05). For all the patients, all the parameters of LV dimension and LV mass had statistically positive correlation to the QT dispersion, but the LV mass was the only independently significant parameter that was correlated with the increased QT dispersion (p<0.05). For group I, none of the echocardiographic parameters had significant correlation with the QT dispersion. However, the LV dimension and LV mass had significantly positive correlation with the QT dispersion, and the LV mass was also the only independently significant parameter that was correlated with increased QT dispersion in group II (p<0.05). Conclusion: Our study demonstrated a significantly positive correlation of the QT dispersion to the LV dimension and the LV mass in patients with stable angina. These findings are present only in patients without significant coronary stenosis.

Aortoventriculoplasty with The Pulmonary Autograft The "Ross-Konno"Procedure -1 case report (자가폐동맥판막을 이용한 대동맥심실성형술 -1례 보고-)

  • 김웅한;이영탁
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.419-422
    • /
    • 1997
  • In small children with left ventricular outflow tract obstruction, a few methods of surgical treatment could be considrred. The pulmonary autogrart provides a promising options for aortic valve replacement as part of the aortoventriculoplasty procedure in children. We report a successfully treated congenital aortic stcnoinsufricicncy with severe left ventricular dysfunction in an early infant with the aortoventriculoplasty using thc pulmonary autograft (the Ross-Konno procedure).

  • PDF

Effects of Scatter Correction on the Assessment of Myocardial Perfusion and Left Ventricular Function by gated Tc-99m Myocardial SPECT (게이트 Tc-99m 심근관류 SPECT에서 산란보정이 심근관류 및 좌심실기능평가에 미치는 영향)

  • Jeong, Hwan-Jeong;Son, Hye-Kyung;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.33-42
    • /
    • 2001
  • Purpose: The purpose of this study was to evaluate the effect of scatter correction on the assessment of myocardial perfusion and left ventricular function by gated Tc-99m myocardial SPECT. Materials and Methods: Subjects were 11 normal volunteers, 20 patients with non-cardiac chest pain and 13 patients with coronary artery diseases. We classified above 3 groups into normal and diseased groups. Scatter correction was done using dual-energy-window scatter correction method (DEW-SC). We compared acquired counts, image contrast, corrected maximum relative counts, indices of left ventricular function, extent and severity of perfusion defects calculated by 'CEqual program' between scatter non-corrected and corrected images. Results: Scatter corrected studios was lower in counts by $18{\pm}3%$ than uncorrected studies, but image contrast were improved in all cases. Scatter correction using DEW-SC took 3 minutes to complete, and 512 kB memory to store. There were no significant differences among indices of left ventricular function between scatter non-corrected and corrected images. Although extents of perfusion defects were not significantly different, severity was severer in scatter corrected images. Conclusion: Scatter correction using DEW-SC is simple to do, and improves image contrast without changing other indices of myocardial perfusion and function.

  • PDF

The Effect of Chordae Preservation in Mitral Valve Replacement (승모판막 치환술에 있어 건삭 보존의 효과)

  • 김공수;조중구;구자홍;김태호
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.353-357
    • /
    • 1999
  • Background: Mitral valve replacement(MVR) with chordal preservation in patients with mitral vlavular disease has been proven to be beneficial for left ventricular function and for reduction of postoperative complication. Material and Method: From January 1995 to July 1996, the early postoperative results of mitral valve replacement were compared between 20 patients who underwent chordae resection(classic MVR group) and 10 patients who underwent chordae preservation(preservation MVR group) in the Department of Thoracic and Cardiovascular Surgery, Chunbuk National University Hospital. Result: There was no significant difference between the two groups in age, sex, NYHA functional class, cardiothoracic ratio, echocardiographic finding, cardiopulmonary bypass time and aortic cross clamping time. The difference between preoperative and postoperative cardiothoracic ratio after 3 months was not statistically significant. At echocardiographic left ventricular evaluation, ejection fraction and fractional shortening decreased slightly in the preservation group then preoperative value (p=0.47, p=0.12), however, decreased significantly in the classic MVR group(p=0.03, p=0.04), and were statistically significant between the two groups(p=0.03, p=0.02). Conclusion: We conclude that MVR with chorda preservation seems to have a beneficial effect on postoperative left ventricular performance in mitral valve disease than the classic MVR.

  • PDF