• Title/Summary/Keyword: 종양의 크기

Search Result 718, Processing Time 0.032 seconds

The Preservation of Left Gastric Artery in Laparoscopy-Assisted Subtotal Gastrectomy with Splenectomy of Stomach Cancer (위암에서 복강경보조 원위부 위아전절제술 및 비장합병절제술 좌위동맥의 보존 증례 보고)

  • Lee, Sang-Rim;Park, Jong-Min;Han, Sang-Uk;Cho, Young-Kwan
    • Journal of Gastric Cancer
    • /
    • v.7 no.1
    • /
    • pp.42-46
    • /
    • 2007
  • Usually in the subtotal gastrectomy, the left and the right gastric arteries, as well as the left and the right gastroepiploic arteries are ligated. Thus, to avoid a blue stomach surgeons preserve the spleen and the short gastric arteries. When a radical subtotal gastrectomy with splenectomy is performed, meticulous caution is necessary; otherwise, the subtotal gastrectomy might have to be changed to a total gastrectomy to prevent a blue stomach. We report the case of a 67-year-old woman who had distal stomach cancer with a splenic solitary mass, for which splenic meatastasis could be excluded. We planned and performed a laparoscopy-assisted radical subtotal gastrectomy with splenectomy as the diagnostic and therapeutic option. In this case, to avoid a remnant stomach infarction or total gastrectomy we saved the left gastric artery and vein with clearing perivascular soft tissue, lymphatics, and lymph nodes. Thus the radical therapeutic goal was reached, and serious complications were avoided.

  • PDF

Evaluation of Real-time Target Positioning Accuracy in Spinal Radiosurgery (척추방사선수술시 실시간 추적검사에 의한 병소목표점 위치변이 평가)

  • Lee, Dong Joon
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.290-294
    • /
    • 2013
  • Stereotactic Radiosurgery require high accuracy and precision of patient positioning and target localization. We evaluate the real time positioning accuracy of isocenter using optic guided patient positioning system, ExacTrac (BrainLab, Germany), during spinal radiosurgery procedure. The system is based on real time detect multiple body markers attached on the selected patient skin landmarks. And a custom designed patient positioning verification tool (PPVT) was used to check the patient alignment and correct the patient repositioning before radiosurgery. In this study, We investigate the selected 8 metastatic spinal tumor cases. All type of tumors commonly closed to thoracic spinal code. To evaluate the isocenter positioning, real time patient alignment and positioning monitoring was carried out for comparing the current 3-dimensional position of markers with those of an initial reference positions. For a selected patient case, we have check the isocenter positioning per every 20 millisecond for 45 seconds during spinal radiosurgery. In this study, real time average isocenter positioning translation were $0.07{\pm}0.17$ mm, $0.11{\pm}0.18$ mm, $0.13{\pm}0.26$ mm, and $0.20{\pm}0.37$ mm in the x (lateral), y (longitudinal), z (vertical) directions and mean spatial error, respectively. And body rotations were $0.14{\pm}0.07^{\circ}$, $0.11{\pm}0.07^{\circ}$, $0.03{\pm}0.04^{\circ}$ in longitudinal, lateral, table directions and mean body rotation $0.20{\pm}0.11^{\circ}$, respectively. In this study, the maximum mean deviation of real time isocenter positioning translation during spinal radiosurgery was acceptable accuracy clinically.

Incidental Breast Lesions on Chest CT: Clinical Significance and Differential Features Requiring Referral (흉부 전산화단층촬영에서 우연히 발견된 유방 병변: 임상적 중요성 및 진료 의뢰가 필요한 특징적 영상 소견)

  • Choi, Yun Jung;Kim, Tae Hoon;Cha, Yoon Jin;Son, Eun Ju;Gweon, Hye Mi;Park, Chul Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.6
    • /
    • pp.303-310
    • /
    • 2018
  • Purpose: To evaluate the CT features of incidental breast lesions on chest CT and to suggest useful criteria for referral to a specialized breast unit. Materials and Methods: Between May 2009 and April 2014, enhanced chest CT examination reports containing the key word 'breast' were reviewed retrospectively. Patients who had incidental breast lesion and were referred to a specialized breast unit and then underwent pathological confirmation or follow-up over a 1-year period were included. Finally, 86 patients (all female, mean age, $48.9{\pm}12.6years$) were enrolled. Two radiologists evaluated lesion characteristics, including size, shape, margins, and enhancement. The correlations between the CT features and pathologies were evaluated, and the diagnostic accuracy of CT features in various combinations was assessed. Results: Among the CT features, irregular shape, non-circumscribed margin, and high contrast enhancement were different between malignant and benign lesions (p < 0.05). The combination of non-circumscribed margin and high contrast enhancement had the highest accuracy (97.7%). Conclusion: Reliable CT features for incidental malignant breast masses are irregular shape, non-circumscribed margin, and high contrast enhancement. The combination of non-circumscribed margin and high contrast enhancement could help distinguish incidental malignant breast lesions and indicate referral to a specialized breast unit.

Solitary, Endobronchial Metastasis from Renal Cell Carcinoma 20 Years after Nephrectomy (신절제술 20년 후에 발생한 신세포암종의 단발성 기관지 내 전이)

  • Min Ju Kim;Jung Im Kim;Kyu Yeoun Won;Han Na Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.994-999
    • /
    • 2021
  • Late recurrence over 10 years after surgery and endobronchial metastasis are some of the specific biological behaviors of renal cell carcinoma (RCC). The current report describes a case of solitary endobronchial metastasis at a subsegmental bronchus that developed 20 years after curative nephrectomy for RCC. A 71-year-old male was admitted to our hospital for pneumonia. Chest radiography showed multifocal ill-defined nodular opacities in the right lower lung zone, suggesting pneumonia. Subsequent chest CT confirmed pneumonic infiltration in the right lung. However, a 4.3-cm, well-defined, elongated mass with a branching pattern was also identified in the right lower lobe, and a right nephrectomy scar was detected on the covered upper abdomen. The patient had undergone right nephrectomy 20 years ago due to clear cell RCC. After right lower lobectomy, the postoperative pathological diagnosis was endobronchial metastatic clear cell RCC. Endobronchial metastasis should be considered in a patient with a history of RCC who presents with a suspected endobronchial tumor, even decades after curative surgery.

Urothelial Carcinoma of the Bladder: Radiologic Perspective (방광 요로상피세포암: 영상의학적 관점)

  • Dong Won Kim;Seong Kuk Yoon;Sang Hyeon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1033-1052
    • /
    • 2021
  • Bladder cancer is a relatively common cancer type, with a high recurrence rate, that can be often encountered in the imaging study. Accurate diagnosis and staging have a significant impact on determining treatment and evaluating prognosis. Bladder cancer has been evaluated by transurethral resection of bladder tumor for clinical staging and treatment, but it is often understaged when compared with final pathologic result by radical cystectomy. If the location, size, presence of muscle invasion, lymph node metastasis, distant metastasis, and presence of upper urinary tract cancer can be accurately diagnosed and evaluated in an imaging study, it can be treated and managed more appropriately. For an accurate diagnosis, radiologists who evaluate the images must be aware of the characteristics of bladder cancer as well as its types, imaging techniques, and limitations of imaging studies. Recent developments in MRI with functional imaging have improved the quality of bladder imaging and the evaluation of cancer. In addition, the Vesical Imaging Reporting and Data System was published to objectively assess the possibility for muscle invasion of cancer. Radiologists need to know the types of bladder cancer treatment and how to evaluate the changes after treatment. In this article, the characteristics of bladder urothelial carcinoma, various imaging studies, and findings are reviewed.

Expression of Peroxiredoxin and Thioredoxin in Human Lung Cancer and Paired Normal Lung (인체의 폐암과 정상 폐조직에서 Peroxiredoxin 및 Thioredoxin의 발현 양상)

  • Kim, Young Sun;Park, Joo Hun;Lee, Hye Lim;Shim, Jin Young;Choi, Young In;Oh, Yoon Jung;Shin, Seung Soo;Choi, Young Hwa;Park, Kwang Joo;Park, Rae Woong;Hwang, Sung Chul
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.2
    • /
    • pp.142-150
    • /
    • 2005
  • Background : Continuous growth stimulation by various factors, as well as chronic oxidative stress, may co-exist in many solid tumors, such as lung cancer. A new family of antioxidant proteins, the peroxiredoxins (Prxs), have been implicated in the regulation of many cellular processes, including cell proliferation, differentiation and apoptosis. However, a real pathophysiological significance of Prx proteins, especially in lung disease, has not been sufficiently defined. Therefore, this study was conducted to investigate the distribution and expression of various Prx isoforms in lung cancer and other pulmonary conditions. Method : Patients diagnosed with lung cancer, and who underwent surgery at the Ajou Medical Center, were enrolled. The expressions of Prxs, Thioredoxin (Trx) and Thioredoxin reductase (TR) were analyzed using proteomic techniques and the subcellular localization of Prx proteins was studied using immunohistochemistry on normal mouse lung tissue. Result : Immunohistochemical staining has shown the isoforms of Prx I, II, III and V are predominantly expressed in bronchial and alveolar lining epithelia, as well as in the alveolar macrophages of the normal mouse lung. The isoforms of Prx I and III, and thioredoxin were also found to be over-expressed in the lung cancer tissues compared to their paired normal lung controls. There was also an increased amount of the oxidized form of Prx I, as well as a putative truncated form of Prx III, in the lung cancer samples when analyzed using 2-dimensional electrophoresis. In addition, a 43 kDa intermediate molecular weight protein band, and other high molecular weight bands of over 20 kDa, recognized by the anti-Prx I antibody, were present in the tissue extracts of lung cancer patients on 1-Dimensional electrophoresis, which require further investigation. Conclusion : The over-expressions of Prx I and III, and Trx in human lung cancer tissue, as well as their possible chaperoning function, may represent an attempt by tumor cells to adjust to their microenvironment in a manner advantageous to their survival and proliferation, while maintaining their malignant potential.

Comparison and Analysis of Photon Beam Data for Hospitals in Korea and Data for Quality Assurance of Treatment Planning System (국내 의료기관들의 광자 빔 데이터의 비교 분석 및 치료계획 시스템 정도관리자료)

  • Lee, Re-Na;Cho, Byung-Chul;Kang, Sei-Kwon
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.179-186
    • /
    • 2006
  • Purpose: Photon beam data of linear accelerators in Korea are collected, analyzed, and a simple method for checking and verifying the dose calculations in a TPS are suggested. Materials and Methods: Photon beam data such as output calibration condition, output factor, wedge factor, percent depth dose, beam profile, and beam quality were collected from 26 institutions in Korea. In order to verify the accuracy of dose calculation, ten sample planning tests were peformed. These Include square, elongated, and blocked fields, wedge fields, off-axis dose calculation, SSD variation. The planned data were compared to that of manual calculations. Results: The average and standard deviation of photon beam quality for 6, 10, and 15 MV were $0.576{\pm}0.005,\;0.632{\pm}0.004,\;and\;0.647{\pm}0.006$, respectively. The output factors of 6 MV photon beam measured at depth of dose maximum for $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.944{\pm}0.006,\;1.031{\pm}0.006,\;and\;1.055{\pm}0.007$. For 10 MV photon beam, the values were $0.935{\pm}0.006,\;1.031{\pm}0.007,\;1.054{\pm}0.0005$. The collected data were not enough to calculate average, the output factors for 15MV photon beam with field size of $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.941{\pm}0.008,\;1.032{\pm}0.004,\;1.049{\pm}0.014$. There was seven institutions $e{\times}ceeding$ tolerance when monitor unit values calculated from treatment planning system and manually were compared. The measured average MU values for the machines calibrated at SAD setup were 3 MU and 5 MU higher than the machines calibrated at SSD for 6 MV and 10 MV, respectively except the wedge case. When the wedges were inserted, the MU values to deliver 100 cGy to 5 cm depends on manufactures. When the same wedge angle was used, Siemens machine requires more MUs then Varian machine. Conclusion: In this study, photon beam data are collected and analyzed to provide a baseline value for chocking beam data and the accuracy of dose calculation for a treatment planning system.

  • PDF

Properties of stretch-activated $K^+$ channels in an G292 osteoblast-like cell (G292 세포에서 세포막 신장으로 활성화되는 $K^+$통로의 특성)

  • Lee, Sang-Gook;Jung, Dong-Keun;Suh, Duk-Joon;Park, Soo-Byung
    • The korean journal of orthodontics
    • /
    • v.30 no.2 s.79
    • /
    • pp.197-204
    • /
    • 2000
  • [$K^+$]-selective ion channels were studied in excised inside-out membrane patches from human osteoblast-like cells (G292). Three classes of $K^+$channels were present and could be distinguished on the basis of conductance. Conductances were $270\pm27\;pS,\;113\pm12\;pS,\;48\pm8\;pS$ according to their approximate conductances in symmetrical 140 mM KCl saline at holding potential of -80 mV It was found that the small conductance (48 pS) $K^+$channel activation was dependent on membrane voltage. In current-voltage relationship, small conductance $K^+$channel showed outward rectification, and it was activated by the positive potential inside the membrane. In recordings, single channel currents were activayed by a negative pressure outside the membrane. The membrane pressure increased $P_{open}$ of the $K^+$ channel in a pressure-dependent manner. In the excised-patch clamp recordings, G292 osteoblast-like cells have been shown to contain three types of $K^+$ channels. Only the small conductance (48 pS) $K^+$channel is sensitive to the membrane stretch. These findings suggest that a hyperpolarizing current, mediated in part by this channel, may be associated with early events during the mechanical loading of the osteoblast. In G292 osteoblast-like cells, $K^+$channel is sensitive to membrane tension, and may represent a unique adaptation of the bone cell membrane to mechanical stress.

  • PDF

Concurrent Weekly Cisplatin and Radiation Therapy for High risk group of Uterine Cervical Cancer (국소적으로 진행된 자궁경부암에 대한 방사선 치료와 Cisplatin의 동시 병행요법의 치료 결과)

  • Suh Hyun Suk;Kang Seung Hee;Kim Ju Ree;Lee Eung Soo;Kim Yong Bong;Park Sung Kwan
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.213-217
    • /
    • 1992
  • Locally advanced cervical carcinoma has shown high rate of local failure and poor survival rate despite the advances in modern radiation therapy techniques. Combination of chemotherapy and radiation therapy demonstrated benefit in improving local control and possibly the overall survival. Twelve patients with advanced stages (Figo stage III, IV) or 11b with bulky tumors (>5 cm in diameter) were treated with combination of radiation therapy and concurrent weekly cisplatin between May of 1988 and September of 1991 at Inje University Paik Hospital. Cisplatin was administered in bolus injections of 50 mg at weekly intervals during the courses of radiation therapy. Median follow-up period was 34 months with ranges from 3 to 53 months. Eleven patients were evaluable for the estimation of response. Response was noted in all the 11 patients: complete response (CR) in 7 ($64\%$), partial response (PR) in 4 ($36\%$). Of the 7 patients with CR, all maintained local control, whereas only 1 of 4 with PR showed local control. Six of 7 with CR are alive disease free on the completion of follow-up. Eight of 11 patients ($73\%$) maintained local control in the pelvis. The median survival for CR patient is 27 months and 9 months for the PR patients. Analysis of survival by stage shows 11 b 4/5, III 2/3 and IV 1/3. Overall survival rate was $61\%$. Three patients recurred: 1 at local, 1 in distant site and 1 with local and distant site. Toxicity for the combination therapy was not excessive. These results are preliminary, but definitely encouraging in view of markedly improved response rate compared with the results of historical control group.

  • PDF

Improved Breast Irradiation Techniques Using Multistatic Fields or Three Dimensional Universal Compensators (Multistatic Field또는 3차원 공용보상체를 사용한 유방의 방사선 조사법의 평가)

  • Han Youngyih;Cho Jae Ho;Park Hee Chul;Chu Sung Sil;Suh Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.24-33
    • /
    • 2002
  • Purpose : In order to improve dose homogeneity and to reduce acute toxicity in tangential whole breast radiotherapy, we evaluated two treatment techniques using multiple static fields or universal compensators. Materials and Methods : 1) Multistatic field technique : Using a three dimensional radiation treatment planning system, Adac Pinnacle 4.0, we accomplished a conventional wedged tangential plan. Examining the isodose distributions, a third field which blocked overdose regions was designed and an opposing field was created by using an automatic function of RTPS. Weighting of the beams was tuned until an ideal dose distribution was obtained. Another pair of beams were added when the dose homogeneity was not satisfactory. 2) Universal compensator technique : The breast shapes and sizes were obtained from the CT images of 20 patients who received whole breast radiation therapy at our institution. The data obtained were averaged and a pair of universal physical compensators were designed for the averaged data. DII (Dose Inhomogeneity Index : percentage volume of PTV outside $95\~105\%$ of the prescribed dose) $D_{max}$ (the maximum point dose in the PTV) and isodose distributions for each technique were compared. Results : The multistatic field technique was found to be superior to the conventional technique, reducing the mean value of DII by $14.6\%$ (p value<0.000) and the $D_{max}$ by $4.7\%$ (p value<0.000). The universal compensator was not significantly superior to the conventional technique since it decreased $D_{max}$ by $0.3\%$ (p value=0.867) and reduced DII by $3.7\%$ (p value=0.260). However, it decreased the value of DII by maximum $18\%$ when patients' breast shapes fitted in with the compensator geometry. Conclusion : The multistatic field technique is effective for improving dose homogeneity for whole breast radiation therapy and is applicable to all patients, whereas the use of universal compensators is effective only in patients whose breast shapes fit inwith the universal compensator geometry, and thus has limited applicability.