• Title/Summary/Keyword: 조형적

Search Result 1,778, Processing Time 0.037 seconds

Recent Progress in Air Conditioning and Refrigeration Research -A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2000 and 2001- (공기조화, 냉동 분야의 최근 연구 동향 -2000년 및 2001년 학회지 논문에 대한 종합적 고찰 -)

  • 강신형;한화택;조금남;이승복;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1102-1139
    • /
    • 2002
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2000 and 2001 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD technologies were widely applied for developing facilities and their systems. (2) Most of papers related with heat transfer analysis and heat exchanger shows dealt with convection, evaporation, and channel flow for the design application of heat exchanger. The numerical heat transfer simulation studies have been peformed and reported to show heat transfer characteristics. Experimental as well as numerical studies on heat exchanger were reported, while not many papers are available for the system analysis including heat exchanger. (3) A review of the recent studies on heat pump system shows that performance analysis and control of heat pump have been peformed by various simulations and experiments. The research papers on multi-type heat pump system increased significantly. The studies on heat pipe have been examined experimently for change of working characteristics and strut lure. Research on the phase change has been carried out steadily and operation strategies of encapsulated ice storage tank are reported experimentally in several papers. (4) A review of recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. Evaporation and condensation heat transfer characteristics are investigated for tube shapes and new alternative refrigerants. Studies on components of refrigeration/air conditioning system are carried to examine efficiency for various compressors and performance of new expansion devices. In addition to thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out, however research works on two-phase flow seemed to be insufficient. (5) A review of the recent studies on absorption cooling system indicates that heat and mass transfer phenomena have been investigated to improve absorber performance. Various experimental data have been presented and several simulation models have been proposed. A review of the recent studies on duct and ventilation shows that ventilation indices have been proposed to quantify the ventilation performance in buildings and tunnels. Main efforts have been focused on the applications of ventilation effectiveness in practice, either numerically using computational fluid dynamics or experimentally using tracer gas techniques. (6) Based on a review of recent studies on indoor thermal environment and building service systems, research issues have mainly focused on many innovative ideas such as underfloor air-conditioning system, personal environmental modules, radiant floor cooling and etc. Also, the new approaches for minimizing energy consumption as well as improving indoor environmental conditions through predictive control of HVAC systems, various activities of building energy management and cost-benefit analysis for economic evaluation were highlighted.

Effects of Cooking Method and Pasteurization Treatment on Instant Thin Rice Porridge Added with Fruits and Vegetables (조리방법 및 살균처리가 과채류를 첨가한 이유식에 미치는 영향)

  • Lee, Hwa-Jin;Kim, Soojung;Bang, Eun;Shin, Haehun;Cho, Hyung-Yong
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.4
    • /
    • pp.569-576
    • /
    • 2016
  • This study researched the effects of cooking methods on phytochemical-enriched thin rice porridge (RP) of three colors (red, yellow, and green). Each of the RPs was prepared by three cooking methods and retorted through two-steps (step 1, at $80^{\circ}C$ for 15 min; step 2, at $82^{\circ}C$ for 25 min) for pasteurization. Cooking method (CM) 1 involved heating a mixture of all ingredients while CM 2 involved addition of apple/beet (AB, red), sweet-pumpkin/cabbage (PC, yellow) or vitamin/pear (green) while heating rice flour and glutinous rice flour. CM 3 involved mixing pre-cooked fruits and vegetables with cooked thin RP. The viscosity of RP prepared by CM 1 was lower than those of other RPs (P<0.05). The result of colorimetric a value show that red and green color of AB and VP prepared by CM 2 and CM 3 were most vivid. Contents of phytochemicals and antioxidants were higher when RP was prepared by CM 2 and CM 3 compared to CM 1. ${\Delta}E$ values of PC showed no significant difference before and after pasteurization, whereas AB and VP were significantly different (P<0.05). Antioxidant activity after retorting was not significantly different from those of un-retorted RPs. The results of color, phytochemical content, and antioxidant activity show that CM 2 or CM 3 were considerably better than CM 1, whereas cooking method had no effect after two-step retorting. Therefore, uncomplicated cooking method such as CM 1 or CM 2 are suited for commercial production of RPs.

A Study of Guide System for Cerebrovascular Intervention (뇌혈관 중재시술 지원 가이드 시스템에 관한 연구)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Yoon, Kwon-Ha;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.1
    • /
    • pp.101-107
    • /
    • 2016
  • Due to the recent advancement in digital imaging technology, development of intervention equipment has become generalize. Video arbitration procedure is a process to insert a tiny catheter and a guide wire in the body, so in order to enhance the effectiveness and safety of this treatment, the high-quality of x-ray of image should be used. However, the increasing of radiation has become the problem. Therefore, the studies to improve the performance of x-ray detectors are being actively processed. Moreover, this intervention is based on the reference of the angiographic imaging and 3D medical image processing. In this paper, we propose a guidance system to support this intervention. Through this intervention, it can solve the problem of the existing 2D medical images based vessel that has a formation of cerebrovascular disease, and guide the real-time tracking and optimal route to the target lesion by intervention catheter and guide wire tool. As a result, the system was completely composed for medical image acquisition unit and image processing unit as well as a display device. The experimental environment, guide services which are provided by the proposed system Brain Phantom (complete intracranial model with aneurysms, ref H+N-S-A-010) was taken with x-ray and testing. To generate a reference image based on the Laplacian algorithm for the image processing which derived from the cerebral blood vessel model was applied to DICOM by Volume ray casting technique. $A^*$ algorithm was used to provide the catheter with a guide wire tracking path. Finally, the result does show the location of the catheter and guide wire providing in the proposed system especially, it is expected to provide a useful guide for future intervention service.

On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT) (콘빔CT (CBCT)를 이용한 온라인 영상유도방사선치료 (On-line Image Guided Radiation Therapy))

  • Bak, Jin-O;Jeong, Kyoung-Keun;Keum, Ki-Chang;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.294-299
    • /
    • 2006
  • $\underline{Purpose}$: Using cone beam CT, we can compare the position of the patients at the simulation and the treatment. In on-line image guided radiation therapy, one can utilize this compared data and correct the patient position before treatments. Using cone beam CT, we investigated the errors induced by setting up the patients when use only the markings on the patients' skin. $\underline{Materials\;and\;Methods}$: We obtained the data of three patients that received radiation therapy at the Department of Radiation Oncology in Chung-Ang University during August 2006 and October 2006. Just as normal radiation therapy, patients were aligned on the treatment couch after the simulation and treatment planning. Patients were aligned with lasers according to the marking on the skin that were marked at the simulation time and then cone beam CTs were obtained. Cone beam CTs were fused and compared with simulation CTs and the displacement vectors were calculated. Treatment couches were adjusted according to the displacement vector before treatments. After the treatment, positions were verified with kV X-ray (OBI system). $\underline{Results}$: In the case of head and neck patients, the average sizes of the setup error vectors, given by the cone beam CT, were 0.19 cm for the patient A and 0.18 cm for the patient B. The standard deviations were 0.15 cm and 0.21 cm, each. On the other hand, in the case of the pelvis patient, the average and the standard deviation were 0.37 cm and 0.1 cm. $\underline{Conclusion}$: Through the on-line IGRT using cone beam CT, we could correct the setup errors that could occur in the conventional radiotherapy. The importance of the on-line IGRT should be emphasized in the case of 3D conformal therapy and intensity-modulated radiotherapy, which have complex target shapes and steep dose gradients.

The Evaluation of Composite Dose using Deformable Image Registration in Adaptive Radiotherapy for Head and Neck Cancer (두경부 종양의 적응방사선치료시 변형영상정합을 이용한 합성선량 평가)

  • Hwang, Chul-Hwan;Ko, Seong-Jin;Kim, Chang-Soo;Kim, Jung-Hoon;Kim, Dong-Hyun;Choi, Seok-Yoon;Ye, Soo-Young;Kang, Se-Sik
    • Journal of radiological science and technology
    • /
    • v.36 no.3
    • /
    • pp.227-235
    • /
    • 2013
  • In adaptive radiotherapy(ART), generated composite dose of surrounding normal tissue on overall treatment course which is using deformable image registration from multistage images. Also, compared with doses summed by each treatment plan and clinical significance is considered. From the first of May, 2011 to the last of July, 2012. Patients who were given treatment and had the head and neck cancer with 3-dimension conformal radiotherapy or intensity modulated radiotherapy, those who were carried out adaptive radiotherapy cause of tumor shrinkage and weight loss. Generated composite dose of surrounding normal tissue using deformable image registration was been possible, statistically significant difference was showed to mandible($48.95{\pm}3.89$ vs $49.10{\pm}3.55$ Gy), oral cavity($36.93{\pm}4.03$ vs $38.97{\pm}5.08$ Gy), parotid gland($35.71{\pm}6.22$ vs $36.12{\pm}6.70$ Gy) and temporomandibular joint($18.41{\pm}9.60$ vs $20.13{\pm}10.42$ Gy) compared with doses summed by each treatment plan. The results of this study show significant difference between composite dose by deformable image registration and doses summed by each treatment plan, composite dose by deformable image registration may generate more exact evaluation to surrounding normal tissue in adaptive radiotherapy.

Implementation of Man-made Tongue Immobilization Devices in Treating Head and Neck Cancer Patients (두 경부 암 환자의 방사선치료 시 자체 제작한 고정 기구 유용성의 고찰)

  • Baek, Jong-Geal;Kim, Joo-Ho;Lee, Sang-Kyu;Lee, Won-Joo;Yoon, Jong-Won;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Purpose: For head and neck cancer patients treated with radiation therapy, proper immobilization of intra-oral structures is crucial in reproducing treatment positions and optimizing dose distribution. We produced a man-made tongue immobilization device for each patient subjected to this study. Reproducibility of treatment positions and dose distributions at air-and-tissue interface were compared using man-made tongue immobilization devices and conventional tongue-bites. Materials and Methods: Dental alginate and putty were used in producing man-made tongue immobilization devices. In order to evaluate reproducibility of treatment positions, all patients were CT-simulated, and linac-gram was repeated 5 times with each patient in the treatment position. An acrylic phantom was devised in order to evaluate safety of man-made tongue immobilization devices. Air, water, alginate and putty were placed in the phantom and dose distributions at air-and-tissue interface were calculated using Pinnacle (version 7.6c, Phillips, USA) and measured with EBT film. Two different field sizes (3$\times$3 cm and 5$\times$5 cm) were used for comparison. Results: Evaluation of linac grams showed reproducibility of a treatment position was 4 times more accurate with man-made tongue immobilization devices compared with conventional tongue bites. Patients felt more comfortable using customized tongue immobilization devices during radiation treatment. Air-and-tissue interface dose distributions calculated using Pinnacle were 7.78% and 0.56% for 3$\times$3 cm field and 5$\times$5 cm field respectively. Dose distributions measured with EBT (international specialty products, USA) film were 36.5% and 11.8% for 3$\times$3 cm field and 5$\times$5 cm field respectively. Values from EBT film were higher. Conclusion: Using man-made tongue immobilization devices made of dental alginate and putty in treatment of head and neck cancer patients showed higher reproducibility of treatment position compared with using conventional mouth pieces. Man-made immobilization devices can help optimizing air-and-tissue interface dose distributions and compensating limited accuracy of radiotherapy planning systems in calculating air-tissue interface dose distributions.

  • PDF

Robust Planning of Intensity-modulated Proton Therapy for Prostate Cancer (전립선암 치료를 위한 세기조절 양성자 로버스트 치료계획)

  • Park, Su Yeon;Kim, Jong Sik;Park, Ju Young;Park, Won;Ju, Sang Gyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.25-31
    • /
    • 2013
  • Purpose: The aim of this study is to evaluate the dosimetric properties of robust planning strategy for plain intensity-modulated proton therapy (IMPT) taking into account of the uncertainties of effective proton range and set up error as compared to photon intensity-modulated radiation therapy (photon-IMRT) in prostate cancer treatment. Materials and Methods: The photon-IMRT (7 beams, step & shoot), plain-IMPT (2, 4, and 7 portals), and robust- IMPT plans, which was recalculated the plain-IMPT based on the uncertainties of range error (${\pm}5%$) and set up error (0.5 cm), were evaluated for five prostate cancer patients prescribed by 70 Gy/35 fractions. To quantitatively evaluate the dose distributions, several parameters such as maximum dose, minimum dose, mean dose, conformity index (CI), and homogeneity index (HI) for PTV as well as dose-volume index of VxGy for OARs were calculated from dose-volume histograms. Results: Robust-IMPT showed superior dose distributios in the PTV and OARs as compared to plain-IMPT and photon-IMRT. Like plain-IMPT, robust-IMPT were resulted in dose fluctuation around OARs, while better homogeneity and conformity in PTVs and lower mean dose in OARs as compared to photon-IMRT. Conclusion: In consideration with the effective range correction and set up movement using robustness in IMPT plan, the dosimetric uncertainties from plain-IMPT could substantially reduce and suggest more effective solutions than photon-IMRT in prostate cancer treatment.

  • PDF

A Study on the Effect of Irrigation Water Temperature to the Growth and Harvest of Paddy Rice in Various Water Sources (수원별 관개용수의 수온이 수함생육과 수량에 미치는 영향에 관한 연구)

  • 조형용
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.14 no.2
    • /
    • pp.2634-2648
    • /
    • 1972
  • The aim of this Study is to bring Light on the effect of irrigation water temperature to the growth and harvest of Paddy rice in Various water Sources. 1. This research was completed in the writer's home nursery garden Located in Chungyoung-Ri, Hoeng sung-Myun, Hoengusung-Konn, Kangwan-Do. 2. The variety of Paddy rice was the IR667. 3. Practice was done by the treatment I .e river water, reservoir, tube well cold and tuke well warm with 3 riplications each. 4. The Paddy was transplanted in a pot 0.9 meter height and 1 meter Square without hottom filled with paddy soil to a planting depth 0.5 meter. The pot was laid underground and Covered with a film of polyethylene to keep of the rain. 5. The method of Cultivation was that used by the Filed Crops Experiment Station of the Office of Rural Development. 6. Atmospheric temperature was recorded every day of the growing period. The precipitation and Sun light was quoted by the KF-46 of Hoengsung. 7. The Soils in the test plots was relatively fortile, being Similar to ordinary paddy soils. 8. The charactor of irrigation water of surface and underground was both normal. 9. During the period of growth the average temperature of the underground water as $14.2^{\circ}C$ and that of the Surface was $24.1^{\circ}$. 10. The most useful water for the rice growing was that of river and reservoir while underground water was found to be generally injurious to the paddy growth because of low temperature. 11. In the case of underground water, there proved to be such harmful effects as reduction of culm length, rate of mature grain, panicle Length and grain weight and delay of tillering time, and heading time. Reading Therefore the writer conduded that the harvest of rice irrigated with underground water Showed a reduction of 15.8% compered with the rice irrigated by surface water.

  • PDF

A Study on the Characteristics of Design and Acculturation of Planting of 'Guǐ(槐)' in Chirinjeong Wonlim of Pohang (포항 칠인정원림(七印亭園林)의 조영특성과 '괴목(槐木)' 식재(植栽)의 문화변용(文化變容))

  • Rho, Jae-Hyun;Han, Sang-Yup;Kim, Jeong-Moon;Jeong, Poo-Reum
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.35 no.3
    • /
    • pp.22-31
    • /
    • 2017
  • The purpose of this study is to illuminate historical sensitivity and design in the days of the Joseon era and examines the phenomenon of acculturation as revealed in the planting of Sophora japonica and Zelkova serrata in the garden grove by looking into the purpose underlying the construction, formative intention and the process of change in Pohang's Chirinjeong wonlim. Chirinjeong, also called Sanggaejeong(雙槐亭) after the fact that two Zelkova serrata trees were planted there, is a hermit pavilion in Sa-il village, Chogok-ri, built in the 9th year of King Taejong(1409) by Jang, Pyo(張彪, 1349~?) of an officer of bureaucratic origin toward the end of the Goryeo Dynasty, the Chirinjeong garden grove is an element essential to Chogok, the 3rd Gok of Sanggaegoogok(雙溪九曲). The wonlim of Chirinjeong is divided into the pavilion section composed of the entrance area, Chirinjeong, composed of Zelkova serrata and Sophora japonica, and the pond section composed of a quadrangular pond and island(方池方島), and Lagerstroemia indica. In view of the intent of the name Chirinjeong or of the fact that the pavilion was named based on that the royal seal string was hung on the Sanggwaesoo(雙槐樹) or two Zelkova serrata trees, it is reasonable to view it as Zelkova serrata trees having been planted early in the days of the Joseon Dynasty and those additionally planted later on that symbolizes the position of the three nobles and the Sophora japonica. In addition, in spite of the fact that the type of trees supplementarily planted in the 21st year of King Yeongjo(1745) is known as Sophora japonica, it is impossible to rule out the possibility of the tree planted outside of Chirinjeong being Zelkova serrata. In short, the three Zelkova serrata trees planted along with Sophora japonica must certainly be evidence that Zelkova serrata planted along with Sophora japonica in Chirinjeong wonlim indicates that the off spring of the Indong Jang family could tell the difference between Sophora japonica and Zelkova serrata. In the recognition process of Zelkova serrata trees finding their way into Korea, it was known as Zelkova serrata on the one hand and as Sophora japonica on the other, and the former, which enjoys a comparative advantage over in terms of the easiness with which to purchase, growth speed and possibility of growing into a long-lived tree was interchanged with Zelkova serrata, a case of acculturation as manifested in the planting of Sophora japonica in the Chirinjeong garden grove.

A Study of volumetric modulated arc therapy for stereotactic body radiation therapy in case of multi-target liver cancer using flattening filter free beam (다중표적 간암의 정위적체부방사선치료에서 무편평화여과기선질 용적변조회전치료의 유용성 평가)

  • Yeom, Misuk;Yoon, Inha;Hong, Donggi;Back, Geummun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.31-43
    • /
    • 2015
  • Purpose : Stereotactic body radiation therapy (SBRT) has proved its efficacy in several patient populations with primary and metastatic limited tumors. Because SBRT prescription is high dose level than Conventional radiation therapy. SBRT plan is necessary for effective Organ at risk (OAR) protection and sufficient Planning target volume (PTV) dose coverage. In particular, multi-target cases may result excessive doses to OAR and hot spot due to dose overlap. This study evaluate usefulness of Volumetric modulated arc therapy (VMAT) in dosimetric and technical considerations using Flattening filter free (FFF) beam. Materials and Methods : The treatment plans for five patients, being treated on TrueBeam STx(Varian$^{TM}$, USA) with VMAT using 10MV FFF beam and Standard conformal radiotherapy (CRT) using 15MV Flattening filter (FF) beam. PTV, liver, duodenum, bowel, spinal cord, esophagus, stomach dose were evaluated using the dose volume histogram(DVH). Conformity index(CI), homogeneity index(HI), Paddick's index(PCI) for the PTV was assessed. Total Monitor unit (MU) and beam on time was assessed. Results : Average value of CI, HI and PCI for PTV was $1.381{\pm}0.028$, $1.096{\pm}0.016$, $0.944{\pm}0.473$ in VMAT and $1.381{\pm}0.042$, $1.136{\pm}0.042$, $1.534{\pm}0.465$ in CRT respectively. OAR dose in CRT plans evaluated 1.8 times higher than VMAT. Total MU in VMAT evaluated 1.3 times increase than CRT. Average beam on time was 6.8 minute in VMAT and 21.3 minute in CRT. Conclusion : VMAT for SBRT in multi-target liver cancer using FFF beam is effective treatment techniqe in dosimetric and technical considerations. VMAT decrease intra-fraction error due to treatment time shortening using high dose rate of FFF beam.

  • PDF