Microstrip Bandpass Filter for Spurious Resonant Mode Rejection using Metameterial Transmission Line (메타매질 전송선로를 이용한 불요 공진모드 제거용 마이크로스트립 대역통과 필터)

  • Yang, Doo-Yeong;Lee, Min-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.566-571
    • /
    • 2009
  • In this paper, microstrip bandpass filter combined DCRLH metameterial-cells with a hairpin resonator is designed and fabricated to be transferred only fundamental passband signal, and removed a spurious resonant mode occurring when filter design using a microstrip transmission line is done. The bandpass filter is composed of CCRLH hairpin resonator and DCRLH interdigit metameterial-cells. The hairpin resonator with CCRLH property is implemented between two DCRLH interdigit metameterial-cells with DCRLH property, which is parallel to input port and output port. The interdigit metameterial-cells suppress spurious harmonics occurring on the higher order frequency and improve a filter performance. Insertion loss of the fabricated microstrip bandpass filter on the passband from 1.91GHz to 2.41GHz is 0.2dB, and attenuation on the stopband from 3GHz to 7.7GHz is bellower than -30dB. Therefore, this filter has a good performance for both mobile communications of WCDMA and wireless internet of WiBro.

Current Sensorless Three Phase PWM AC/DC Boost Converter with Unity Power Factor (전류센서리스 단위역률 3상 PWM AC/DC Boost 컨버터)

  • 천창근;김철우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.105-112
    • /
    • 2003
  • Diode rectifier which can't be controlled output voltage and phase control converter as AC/DC converter have low power factor and harmonics of lower order in the line current. In this paper, three phase PWM(Pulse Width Modulation) AC/DC boost converter is studied to solve these problems. The characteristics of a proposed converter are to control the phase of current without current sensor as a very simple control algorithm using circuit parameters only and to apply sinusoidal PWM method with fixed switching frequency due to a difficult design of input filter and switching device. We simulate for the proposed algorithm that high power factor is achieved and DC link voltage has fast dynamic response without ripple in rectifying and regenerating operation. As a result of experiment with circuit parameter(inductor, capacitor) decided in simulation, the proposed converter had high power factor and reduction of low order harmonics as against diode rectifier.

Development of Artificial-Intelligent Power Quality Diagnosis Algorithm using DSP (DSP를 이용한 인공지능형 전력품질 진단기법 연구)

  • Chung, Gyo-Gbum;Kwack, Sun-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.116-124
    • /
    • 2009
  • This paper proposes a new Artificial-Intelligent(AI) Power Quality(PQ) diagnosis algorithm using Discrete Wavelet Transform(DWT), Fast Fourier Transform(FFT), Root-Mean-Square(RMS) value. The developed algorithm is able to detect and classify the PQ problems such as the transient, the voltage sag, the voltage swell, the voltage interruption and the total harmonics distortion. The 15.36[kHz] sampling frequency is used to measure the voltages in a power system. The measured signals are used for DWT, FFT, RMS calculation. For AI diagnosis of the PQ problems, a simple multi-layered Artificial Neural Network(ANN) with the back-propagation algorithm is adopted, programmed in C++ and tested in PSIM simulation studies. Finally, the algorithm, which is installed in MP PQ+256 with TI DSP320C6713, is proved to diagnose the PQ problems efficiently.

Design and Fabrication of a Multi-Function Circuit to Implement Hybrid-Conversion RF Front-End for Broadband and Multiband System (광대역 및 다중 대역 시스템용 혼성 변환 방식 RF 전단부 구현을 위한 다중 기능 회로의 설계 및 제작)

  • Go, Min-Ho;Ju, Young-Rim;Jo, Yun-Hyun;Park, Hyo-Dal
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.3
    • /
    • pp.292-300
    • /
    • 2010
  • In this paper, we propose a RF front-end architecture based on hybrid conversion which is available to receive both broadband and multiband DVB-H receiver, and a multi-function circuit for implementing the RF front-end is fabricated. A multi-function circuit is operated as a sub-harmonic mixer mode in the case of receiving a broadband VHF/UHF band, which show a conversion loss of -10.0 dB, noise figure of 7.0 dB and IIP3 of 2.0 dBm. On the other hand, it is performed as a attenuation mode with a insertion loss of -10.0 dB in receiving a multiband, L-band.

지점우량 자료의 분포형 설정과 내용안전년수에 따르는 확률강우량에 관한 고찰 - 국내 3개지점 서울, 부산 및 대구를 중심으로 -

  • Lee, Won-Hwan;Lee, Gil-Chun;Jeong, Yeon-Gyu
    • Water for future
    • /
    • v.5 no.1
    • /
    • pp.27-36
    • /
    • 1972
  • This thesis is the study of the rainfall probability depth in the major areas of Korea, such as Seoul, Pusan and Taegu. The purpose of the paper is to analyze the rainfall in connection with the safe planning of the hydraulic structures and with the project life. The methodology used in this paper is the statistical treatment of the rainfall data in the above three areas. The scheme of the paper is the following. 1. The complementation of the rainfall data We tried to select the maximm values among the values gained by the three methods: Fourier Series Method, Trend Diagram Method and Mean Value Method. By the selection of the maximum values we tried to complement the rainfall data lacking in order to prevent calamities. 2. The statistical treatment of the data The data are ordered by the small numbers, transformed into log, $\sqrt{}, \sqrt[3]{}, \sqrt[4], and$\sqrt[5], and calculated their statistical values through the electronic computer. 3. The examination of the distribution types and the determination of the optimum distibution types By the $x^2-Test$ the distribution types of rainfall data are examined, and rejected some part of the data in order to seek the normal rainfall distribution types. In this way, the optimum distribution types are determined. 4. The computation of rainfall probability depth in the safety project life We tried to study the interrelation between the return period and the safety project life, and to present the rainfall probability depth of the safety project life. In conclusion we set up the optimum distribution types of the rainfall depths, formulated the optimum distributions, and presented the chart of the rainfall probability depth about the factor of safety and the project life.ct life.

  • PDF

Comparison of Agronomic Characteristics, Productivity and Feed Values of Summer Sowing Sorghum Hybrids in Gyeongbuk (경북지역에서 여름 파종 수수류 교잡종의 생육특성, 수량성 및 사료가치 비교)

  • Shin, Chung Nam;Ko, Ki Hwan;Kim, Jong Duk
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.35 no.2
    • /
    • pp.99-104
    • /
    • 2015
  • This study was conducted to evaluate on agronomic characteristics, dry matter (DM) and digestible dry matter (DDM) yields of summer sowing sorghum hybrids (Sorghum bicolor (L) Moench) at Seongju in Gyeongbuk from 2013 to 2014. The experiment was arranged in randomized complete block design with three replications. Sorghum hybrids were seeded $31^{st}$ of July, 2013 and 2014. Sorghum hybrids were harvested on $3^{rd}$ November, 2013 and $5^{th}$ November, 2014. The observed average heading date was October 5, 8 and 9 for Sordan79, Sprint and SX17 respectively. The DM yield of 'SX17', 'Sordan79', and 'Sprint' was 24.2, 23,9 and 23.4 ton/ha, respectively and DM yield of those were significantly higher (p<0.05) than other three cultivars in 2013. DM yield of 'SX17', 'Sprint' and 'Sordan79' was 20.8, 20.0 and 19.3 ton/ha, respectively and DM yield of those was significantly higher (p<0.05) than other three cultivars in 2014. The DDM yield of 'SX17', 'Sordan79', and 'Sprint' was also higher (p<0.05) than other three cultivars in 2013 and 2014. ADF content of sorghum hybrids was low, whereas DDM was high. The results of this study indicated that traditional sorghum-sudangrass hybrids ('SX17', 'Sordan79') and sudan grass-sudangrass hybrid ('Sprint') than late flowering sorghum-sudangrass hybrid ('PACF8350') and sorghum-sorghum hybrids ('SS405', 'Sugar grazer') would be recommended for DM and DDM yields in the southern Korea.

A Study on the Power Converter Control of Utility Interactive Photovoltaic Generation System (계통 연계형 태양광 발전시스템의 전력변환기 제어에 관한 연구)

  • Na, Seung-Kwon;Ku, Gi-Jun;Kim, Gye-Kuk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.2
    • /
    • pp.157-168
    • /
    • 2009
  • In this paper, a photovoltaic system is designed with a step up chopper and single phase PWM(Pulse Width Modulation) voltage source inverter. Where proposed Synchronous signal and control signal was processed by one-chip microprocessor for stable modulation. The step up chopper operates in continuous mode by adjusting the duty ratio so that the photovoltaic system tracks the maximum power point of solar cell without any influence on the variation of insolation and temperature because solar cell has typical voltage and current dropping character. The single phase PWM voltage source the inverter using inverter consists of complex type of electric power converter to compensate for the defect, that is, solar cell cannot be developed continuously by connecting with the source of electric power for ordinary use. It can cause the effect of saving electric power. from 10 to 20[%]. The single phase PWM voltage source inverter operates in situation that its output voltage is in same phase with the utility voltage. In order to enhance the efficiency of photovoltaic cells, photovoltaic positioning system using sensor and microprocessor was design so that the fixed type of photovoltaic cells and photovoltaic positioning system were compared. In result, photovoltaic positioning system can improved 5% than fixed type of photovoltaic cells. In addition, I connected extra power to the system through operating the system voltage and inverter power in a synchronized way by extracting the system voltage so that the phase of the system and the phase of single-phase inverter of PWM voltage type can be synchronized. And, It controlled in order to provide stable pier to the load and the system through maintaining high lurer factor and low output power of harmonics.