• Title/Summary/Keyword: 조절 반응량

Search Result 533, Processing Time 0.019 seconds

Comparison on Accommodative Response Changes in the Normal Group and Convergence Insufficiency (정상군과 폭주부족군에서 조절반응 변화량의 비교)

  • Kwak, Ho-Weon;Lee, Se-Hee;Kwak, Hyung-Bin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.79-85
    • /
    • 2014
  • Purpose: This study investigated accommodative changes by measuring accommodative response, appearing on the normal and convergence insufficiency Group, by using both eyes open-view auto-refractometer (Nvision-K5001, shin-nippon, Japan). Methods: It carried out objective and subjective refractions, targeting 74 college students (54 males and 20 females) aged between 19 and 29 ($21.59{\pm}2.53$), spherical equivalent OD $-2.28{\pm}2.03$ D, OS $-2.18{\pm}2.01$ D, by measuring accommodative responses at full correction and under correction with plus lens +0.25, +0.50, +0.75 arbitrarily added. Results: In the group of normal and convergence insufficiency, the shorter fixation distances were, the greater accommodative lags showed. The group of convergence insufficiency showed the lesser changes of accommodative response than those of normal. But we found that the convergence insufficiency group had a little larger accommodative amplitude in the total fixation distances. The full correction of convergence insufficiency group and the under correction (+0.50 D) of normal were alike in the accommodative responses. We have also investigated that the correlation between accommodative responses and fixation distances was decreased steeply at the excessive low vision correction. Conclusions: Under correction (+0.50 D) in a near distance is expected to avoid unnecessary accommodative responses, make eyes relaxed and comfortable.

Comparison between Accommodative Response Change on the Full Vision Correction and Low Vision Correction (완전교정과 저교정 상태에서 조절반응 변화량의 비교)

  • Bae, Sung-Hyun;Kwak, Ho-Weon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.75-81
    • /
    • 2012
  • Purpose: The study tried to figure out accommodative changes by measuring accommodative response, appearing on the full vision correction and low vision correction, with both eyes open-view auto-refractometer (Nvision-K5001, Shin-nippon, Japan). Methods: It carried out objective and subjective refractions, targeting 79 college students (58 males and 21 females) aged between 20 and 30($21.14{\pm}2.00$), by measuring accommodative changes with fixation distance at 1.0 m for eyesight of 1.0 after full version correction. The distances of 5.0 m, 1.0 m, 0.50 m, 0.33 m and 0.25 m for eyesight of 0.8, 0.7 and 0.6 after low vision correction arbitrarily added plus lens were applied. Results: the shorter measure fixation distances were, the greater changes accommodative response showed a tendency in the state of both full vision correction and low vision correction(0.7). The state of full vision correction showed a greater change of accommodative response than that of low vision correction(0.7). Both right and left eyes showed low accommodative responses in the state of low vision correction(0.7) than that of full vision correction. As a result of analyzing accommodative response at an eyesight of 0.8, 0.7, and 0.6 after low vision correction, the poorer eyesight was the lower accommodative response. Conclusions: Low vision correction from a near distance is expected to avoid unnecessary accommodative response, make eyes relaxed and prevent accommodative function disorder.

Comparison between Response AC/A and CA/C Ratio according to Additional Spherical Powers and Prism Powers (가입렌즈 도수와 프리즘 굴절력 변화에 따른 반응 AC/A비와 CA/C비 비교)

  • Roh, Byeong-Ho;Yu, Dong-Sik;Son, Jeong-Sik;Kwak, Ho-Weon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.341-347
    • /
    • 2015
  • Purpose : This study was to examine a correlation of response AC/A ratio by additional spherical powers with PD(Pupilary distance) and relative accommodation, and was to investigate correlation of CA/C ratio by prism powers. The mean differences between a reciprocal response AC/A ratio and a CA/C ratio were compared, and were suggested to be used as data in the refractive power and prism prescriptions in the clinical. Methods: The open field autorefractometer (Nvision-K 5001, Shin nippon) and Howell target at 40 cm fixation distance to 62 persons with average $22.62{\pm}2.84$ ages were used to measure the response AC/A ratio according to additional Spherical powers. The CA/C ratios were measured using the DOG card at 40cm according to prism powers. Results: When the response accommodation according to Additional Spherical power changes and the response accommodation according to prism power changes were compared, it was larger than the response accommodation according prism power change. These were significant differences statistically. The correlation of response AC/A ratio and PD is showed as r = -0.158, the CA / C ratio is shown as r = 0.093. The correlation of response AC/A ratio and relative accommodation showed as r = -0.253, the CA/C ratio showed as r = 0.566 that is predictable correlation. The correlation of response AC/A ratio and CA/C ratio showed as r = -0.355 that is low minus correlation (p = 0.000). The difference between a reciprocal response AC/A ratio and a CA/C ratio showed $0.12{\pm}0.06D/{\Delta}$ with a significant difference statistically (p=0.000). Conclusions: The correlation of relative accommodation and CA/C ratio showed that depend on the individual, The more a relative accommodation is, the higher a response accommodation of convergence by convergence stimulus is. The reciprocal response AC/A and CA/C ratio showed significant differences statistically. This can have higher CA/C ratio in patients with low AC/A ratio in clinical as an independent variable. Thus when the abnormal binocular vision was prescribed in the clinical, it is necessary to consider the accommodative response even if the AC/A ratio is a normal range.

Physiological and Psychological Thermal Responses to Local Heating of the Human Body in a Cold Environment (한랭환경하에서 인체의 국소가온 자극이 온열생리.감각반응에 미치는 영향)

  • Shin, Jounghwa
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.10
    • /
    • pp.1745-1753
    • /
    • 2001
  • 본 연구는 한랭 환경 하에서의 인체의 국소 가온 자극이 생리, 감각반응에 끼치는 영향을 검토했다. 건강한 성인여자 7명을 대상으로, 기온 $25^{\circ}C$, 습도50%의 환경 하에서 균일한 국소 가온을 부하 했을 때 피부온, 고막온, 손가락, 발가락 혈류량, 온냉감, 쾌적감의 반응에 미치는 영향을 검토한 결과는 다음과 같다. 1) 국소가온에 의해 가온 부위 피부온은 유의하게 상승하고 가온 부위에 따라 상승도에는 유의한 차가 보였다. 2) 국소가온에 의해 고막온은 머리의 가온 시에 높은 상승, 전완의 가온 시에 상승하고, 다른 가온 부위에서는 하강의 경향이 보였다. 3) 국소가온에 의해 혈류량의 변화는 3개의 군으로 분류된다. 가온과 함께 손가락 혈류량이 증가하는 군, 발가락 혈류량이 변화하는 군, 양쪽의 혈류량이 적게 변화하는 군으로 나누어진다. 이것을 각 피험자의 평균 피부온 수준 즉 체온조절 수준과 관계 있는 것으로 논할 수 있다 4)국소 가온에 의해 각 부 위 피부온으로의 파급효과는 머리, 상완의 가온 시에 크지만 대퇴, 하퇴 다리의 가온 시에는 대부분의 부위에서 영향이 보이지는 않았다. 5) 이와 같이 국소 가온에 의 한 생리, 감각반응은 가온 부위에 따라 다르고 머리, 상완의 가온 시에는 생리반응이 크고 하퇴, 다리의 가온시에는 국소의 감각변화가 컸다.

  • PDF

Comparison of Accommodative Response among Emmetropes, Spectacle and Contact Lens Wearer (정시, 안경 및 콘택트렌즈 착용자의 조절반응량 비교)

  • Lee, Kyu-Byung;Park, Jeehyun;Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.403-410
    • /
    • 2012
  • Purpose: The purposes of this study are to investigate accommodative response among emmetropes, spectacle wearer and contact lens wearer, and correlation between refractive error and accommodative respons for each group. Methods: The 72 subjects(144 eyes) who do not have any ocular diseases were participate in this study. Subjects were categorized into emmetropes, spectacle wearer and contact lens wearer by refractive error using closed-field auto-refractometer. We measured dominant eye, naked/habitual visual acuity and refractive error of monocular/binocular vision of refractive error for far/near distance with open-field auto-refractometer and calculated accommodative lag. Results: There were no significant difference of accommodative lag between right and left eye dominant and non-dominant eye, monocular and binocular vision, and spectacle lens wearer and contact lens wearer, However the accommodative lag of binocular vision was severe than monocular vision at near. The lag of myopia was larger than emmetropes, and male was larger than female. Significant correlation was found between refractive error and accommodative lag in total subjects and the same result was found in emmetropes and contact lens wearer. However there were no significant correlation in the spectacle wearer. Conclusions: There were significant difference between emmetrops and myopes in terms of accommodative lag, however accommodative lag of spectacle wearer was not different with contact lens wearer in myopes. There were also significant correlation between refractive error and accommodative lag in emmetropes and contact lens wearer, but the accommodative lag of spectacle wearer was not significantly correlated with refractive error.

A Clinical Study on Relation among Accommodative Amplitude, Response, and Facility in young adults (청.장년층에서 조절력 및 조절반응과 조절용이의 상관관계에 관한 임상적 연구)

  • Shim, Hyun-Seog;Joo, Seok-Hee;Leem, Hyun Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.115-119
    • /
    • 2009
  • Purpose: This study has been conducted to know the relation among accommodative amplitude, response, and facility. Methods: 61 subjects were students without any ocular diseases and presbyopia in a university, Korea. After far distance visual acuity was fully corrected, the amplitude was measured through Push-Up test, the response was measured through Jackson crossed cylinder ${\pm}$0.25D and the facility was measured through +2.00/ -2.00D flipper. Results: The relation among accommodative facility, response and amplitude had not indicate significant level in monocular and binocular. In binocular, 12 eyes (19.6%) had a difference in amplitude, 9 eyes (14.7%) had a difference in response, 2 eyes (3.2%) had a difference in facility from norm which would be expected from their age. 4 eyes (6.5%) had difference in both amplitude and response. 2 eye (3.2%) had difference in both amplitude and facility. In all three of the amplitude, response, facility had not difference. Conclusions: The evaluation of accommodative functions and a patients accommodative dysfunction is examined all facets of amplitude, response, and facility.

  • PDF

Control of Polyaniline Molecular Weight Based on p-aminodiphenylamine (p-aminodiphenylamine을 이용한 폴리아닐린 분자량 조절)

  • Hong Jang-Hoo;Jeon, Je Yeoul
    • Applied Chemistry for Engineering
    • /
    • v.20 no.1
    • /
    • pp.75-79
    • /
    • 2009
  • The ratio of aniline dimer (p-aminodiphenylamine), which is a nucleation site of chain growth in a chemical polymerization of aniline monomer, to aniline monomer was controlled to synthesize polyaniline with the molecular weight ($M_w$) between 10000 and 20000 g/mol. The result of OCP measurement showed that the reaction rate of polymerization was increased as the mole ratio of dimer was increased. The increase in the molar ratio of dimer resulted in the shift of absorption wavelength of polyaniline to the short wavelength region on measurement of UV/Vis and the decrease of molecular weight on the measurement of GPC.

Accommodative response measurement using both eyes open-view autorefractometer (양안 개방형 자동굴절검사기를 이용한 조절반응량 검사)

  • Shim, Hyun-Seog;Lee, Seong-Wook;Shim, Moon-Sik;Choi, Sun-Mi;Jang, Seong-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.323-328
    • /
    • 2005
  • The purpose of this research was to measurement real Accommodative response amount using both eyes open-view autorefractometer. Compared each Accommodative response amount to distinction of sex, age, kind of ametropia, amount of astigmatism and kind of astigmatism. The subjects were 153 healthy men and women between the age of 20~80 years. Age comparison, 20 years 1.15D, 30 years 1.23D and above 40 years 0.60D. It was no difference between 20 to 30 years old. But, is decrescent remarkably above 40 years old. Ametropia examined by hypermetropia 1.78D, emmetropia 1.51D, low myopia 1.08D, middle myopia 0.72D, high myopia 0.643D. Myopia increased, Accommodative response amount was expose that decrease. Astigmatism examined by non astigmatism 1.13D, low astigmatism 1.12D, middle astigmatism 0.85D, high astigmatism 0.83D. Astigmatism increased, Accommodative response amount was expose that decrease. The sex and astigmatism type difference appeared with the fact that the result is not a difference.

  • PDF

Molecular Weight Distribution Inside and Outside Capsules Using Coencapsulating Technology (공동캡슐화를 이용한 Capsule 내외부의 분자량 분포)

  • 이기선;임현수
    • KSBB Journal
    • /
    • v.16 no.4
    • /
    • pp.321-326
    • /
    • 2001
  • The change of molecular weight inside and outside a capsule produced using coencapsulating technology was investigated. Chitosan and chitosanase were enveloped in this membrane and product released was a loaded the medium by the principle of size exclusion. The leakage of substrate corresponding to the agitation speed was controlled by adjusting the alginate and CaCO$_3$ concentrations. The optimal condition of alginate concentration and agitation speed were 0.5% and 40rpm, respectively. Membrane thickness and capsules diameter were 10 $\mu$m and approx. 3.0 - 1.5 mm, respectively. Molecular weight difference by concentration and alginate viscosity were of little significance. In accordance with the molecular weight distribution versus enzyme concentration relationship, low concentration of enzyme produced high molecular weight oligosaccharides. At a 1.5 mm capsule size the product diffusion rate to outer surface highest. The molecular weight distribution of the released oligosaccharides was ranged from 1000 to 6000 Da. More than 80% of the initial activity of encapsulated enzyme retained after 8hrs of reaction.

  • PDF

Analysis and Design of an Accommodation-Dependent Eye Model Based on Navarro Model (Navarro 모형안에 기반을 둔 조절을 고려한 모형안의 설계 및 분석)

  • Kang, Eun Kyoung;Park, Sung Chan;Kim, Jin Joo;Hwangbo, Chang Kwon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.235-240
    • /
    • 2010
  • Purpose: In this study, we proposed a simple accommodation-dependent crystalline lens with a constant volume and homogeneous refractive index. Methods: We proposed a human crystalline lens with two aspheric surfaces. Two surfaces intersect in two points and straight line between two points was equator(2b). It assumed that the derivative in axial direction was zero at the equator and the radial derivative was zero at the vertex. Proposed human crystalline lens was divided by the equator into the anterior and posterior parts. It was assume that the volume of each part and refractive index of the human crystalline lens were constant during accommodation. Results: For the changes during accommodation, geometrical parameters were determined by different objective distances. Considering the constant volume of each part with the small decrement of the equator, we obtained the paraxial parameters, such as the anterior and posterior vertex radius of curvature and lens thickness. Compared with the experimental data published in the literature, calculated values using simple approximation showed similar change per accommodative stimulus. Conclusions: These results showed that proposed simple approximation using assumption of constant volume and refractive index of the human crystalline lens made it possible to predict changes of geometrical parameters during accommodation.