• Title/Summary/Keyword: 조영

Search Result 9,154, Processing Time 0.041 seconds

Medical Parameter Extraction Using Time-Density Data in Contrast-Enhanced Ultrasound Image Sequence (조영증강 초음파영상에서 밀도변화 데이터를 이용한 진단 파라미터 추출 기법)

  • Lee, Jun-Yong;Jung, Joong-Eun;Kim, Ho-Joon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.7
    • /
    • pp.297-300
    • /
    • 2015
  • In medical ultrasonography, transit time and contrast enhancement patterns are considered as important parameters to analyze liver diseases. In many recent researches, time-intensity curves(TIC) have been used for calculating the transit time of the contrast agents. However, the intensity curve may include the variations which are caused by the micro-bubble effect of contrast agents. In this paper, we propose a complementary approach to diagnostic parameter extraction which utilizes a density information as well as the intensity data. The proposed technique improves the accuracy in extraction of the transit time and velocity of contrast agents for detection and characterization of focal liver lesions. Through the experiments using a set of clinical data, we show that the proposed methods can improve the reliability of the parametric image data.

ROI Extraction Method for Lesion Detection in Contrast-Enhanced Ultrasonography (조영증강 초음파 동영상에서 병변 탐색을 위한 ROI 추출기법)

  • Gwak, Seong-Hoon;Kang, Ji-Hyeon;Lee, Hye-Min;Kim, Ho-Joon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2013.11a
    • /
    • pp.1312-1314
    • /
    • 2013
  • 본 연구에서는 조영증강 의료 초음파 영상에서 효과적인 병변 탐색을 위한 방법론을 고찰한다. 병변 영상을 포함하는 ROI 추출을 위하여 조영효과의 전이 형태에 대한 단계 분할 기법과 동적 프로젝션 데이터의 분석 기법을 제안한다. 프레임간 유사도 척도의 분석을 통하여 비정상 프레임을 제거한 후 조영제의 도달시간(AT: Arrival Time)과 확산구간을 추출하여 탐색 대상 데이터의 양을 감소시킨다. 대상구간에서 초음파 영상의 수평방향 및 수직방향 프로젝션 데이터에 대한 동적 특성을 분석함으로써 후보영역을 추출하며 마이크로 버블의 추출, 조영효과의 증가속도 및 비율 등의 요소를 고려하여 ROI 를 선별하고 그 형태를 재조정한다. 부수적으로, 대상영역에서의 각 픽셀정보에 대하여 명도변화곡선(TIC) 특성분석을 통하여 영상을 재구성하고 병변영상의 형태와 윤곽선을 추출하게 된다.

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF

Harmonic generation emitted from ultrasonic contrast agent in response to a typical diagnostic ultrasound (전형적인 진단용 초음파에 의해 초음파 조영제에서 방사하는 하모닉 성분의 크기)

  • Choi M. J.;Kang K. S.;Paeng D. G.;Rhim S. M.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.373-378
    • /
    • 2004
  • 하모니 영상은 초음파의 비선형 전파 과정에서 발생된 하모닉 성분을 영상화 한다. 하모닉 영상은 초음파에 비선형적으로 반응하는 초음파 조영제를 사용하여 하모닉 성분의 발생을 최대화 하고 있다. 일반적으로 현재 임상적으로 사용되는 하모닉 영상은 2차 고주파 성분을 사용한 것을 의미한다. 2차 하모닉 영상은 주파수의 상승으로 공간 분해능이 향상된다. 초음파 조영제를 이용하는 경우 서브 하모닉, 울트라 하모닉의 발생도 유의할 것으로 기대되지만 이에 대한 연구는 거의 없는 실정이다. 서브 하모닉은 상대적으로 2차 하모닉보다 전파 과정에서 감쇠 효과가 작기 때문에 심부의 영상에 유리하다 서브 하모닉 및 울트라 하모닉 성분 검출은 초음파 변환기의 대역폭에 대한 제한을 2차 하모닉에 비해 상대적으로 덜 받는다. 본 연구에서는 진단용 초음파에 의해 초음파 조영제에서 방사하는 하모닉 성분의 크기를 시뮬레이션 하였다. 수치해석은 Gilmore Equation을 이용하였으며, 초음파 조영제의 탄성 효과는 무시하였다. 초음파 조영제의 크기와 초음파의 MI에 따라 하모닉 성분의 크기를 정량적으로 비교하고, 서브 및 울트라 하모닉 영상의 구현에 대해 토의하였다.

  • PDF

무게 중심 기반 자기 구성 지도를 위한 간암 추출 및 분석

  • Jung, Kyung-Hoon;Jang, Do-Won;Kim, Kwang-Baek
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 2007.11a
    • /
    • pp.520-529
    • /
    • 2007
  • 간암은 세계적으로 흔한 악성 종양에 속하지만 우리나라에서 간암은 위암, 폐암 다음으로 높은 사망률을 보이며 이러한 간암은 조기진단이 요구된다. 전문의는 간암의 진단을 위해 조영증강 CT영상을 이용하여 육안으로 간암을 판별하는데, 조영증강 CT영상을 이용한 진단은 주 종양의 진단에는 도움이 되지만 주 종양에서 주위 간 조직으로 전이된 간암들을 판별하는 것은 어려우며 실제로 시술 중에야 전이된 간암의 존재를 알 수 있다. 본 논문에서는 조영증강 CT영상을 이용하여 간과 주 종양을 자동으로 추출한 후, 미세하게 주 종양 주위로 전위된 간암들을 추출하는 방법을 제안하여 전문의를 보조할 수 있는 보조 전문가 시스템으로서의 유용성을 확인하고자한다. 조영증강 CT영상은 흉부에서 5mm간격으로 40 ${\sim}$ 50장정도로 촬영된다. 조영증강 CT영상을 이용하여 간 영역을 추출하기 위해서 간의 형태학적 정보 그리고 명암도와 명암의 분포도를 이용한 양자화 기법 등을 적용하여 추출하며 추출된 간 영역에서 간암의 후보 영역 추출은 간암의 명암도와 형태학적 특징 정보를 이용하여 추출한다. 본 논문에서는 간암의 추출을 위해 맵 상에 흩어져 분포되어 있는 유사 패턴들의 무게 중심을 찾아 하나의 패턴으로 그룹화 하는 개선된 SOM 알고리즘을 제안하여 간암 판별에 적용한 후, 기존의 SOM 알고리즘과 비교 분석한 결과. 본 논문에서 제안된 SOM 알고리즘을 적용한 간암 추출이 더 효율적임을 확인 할 수 있었으며, 전문의가 판별한 것과 비교 분석한 결과, 전문의를 보조할 수 있는 보조 전문가 시스템으로서의 가능성을 확인할 수 있었다.

  • PDF

CT Findings of Desmoid Tumor arising at Abdominal Wall: Two Cases Report (복벽에 발생한 데스모이드 종양의 급속 조영 CT 소견 : 2례 보고)

  • Cho, Dae-Hyoun;Cho, Jae-Ho;Chang, Jae-Chun
    • Journal of Yeungnam Medical Science
    • /
    • v.12 no.2
    • /
    • pp.386-392
    • /
    • 1995
  • Desmoid tumor is a type of fibromatosis usually arise in deep musculo-aponeurotic structures, primarily of the trunk and extremities. It is characterized by proliferation of fibroblastic tissue and does not metastasize but may be locally aggressive. Eventhough the surgical margin reveals clean, recurrence often occurs. To analyze the extent of the tumor and homodynamic characteristics exactly, we performed IV bolus CT. Desmoid tumors show peripheral rim enhancement on early phase scan and more strong, central enhancement on late phase IV bolus CT, which reflects abundant fibroblastic components of the tumor. We report two cases of pathologically confirmed desmoid tumor performed IV bolus CT.

  • PDF

A Parametric Imaging Technique for Characterizing Focal Liver Lesions in Contrast-Enhanced Ultrasound (간 병변 분석을 위한 조영증강 초음파 데이터의 영상화기법)

  • Park, So-Jeong;Sung, Myung-Chul;Lee, Seung-Kang;Kim, Ho-Joon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.11a
    • /
    • pp.369-372
    • /
    • 2012
  • 조영증강 의료 초음파 영상에서 조영제의 확산효과에 대한 분석은 간질환과 연관된 각종 병변을 검출하고 분석하는 과정에서 매우 유용한 정보를 제공한다. 본 연구에서는 초음파 영상에서 조영제의 확산 패턴을 분석하고 이를 영상화하는 방법을 제안한다. 이 과정에서 부수적으로 호흡에 의한 흔들림 현상을 보정하고 노이즈의 영향을 극복할 수 있는 방법론을 고찰한다. 호흡주기에 따른 모멘텀 요소를 고려한 ROI 추적 기법은 측정과정에서의 흔들림과 노이즈에 의한 오류를 최소화 할 수 있게 한다. 조영제의 확산 단계에 따라 서로 다른 노이즈 비율을 고려하여 동적 가중치를 할당하는 방법으로써 흔들림을 보정하였으며, 조영제의 전이 시간과 패턴을 분석하고 그 특성을 분류함으로써 간 병변 분석을 위한 효과적인 영상화기법을 구현하였다. 또한 생성된 영상에서 노이즈를 제거하고 영상을 개선하는 방법으로서 MRF 기반의 최적화 알고리즘을 적용하는 영상 개선 기법을 제시한다.

Improvement of Patient Safety and Inspection Satisfaction by Developing Pretreatment Process System with the Patients Who Reserved CT Enhance Examination (CT 조영검사 예약환자의 전처치 프로세스 시스템 개발을 통한 환자안전 및 검사 만족도 향상)

  • Beom, Hyinam;Han, Jaebok;Song, Jongnam;Kim, Wook;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.29-37
    • /
    • 2016
  • This study aims to improve the satisfaction level of the patient who undergoes CT contrast examination by developing and applying pretreatment process system, which not only can reduce the side effects caused by the test but also can help carry out the test smoothly. The subjects were 214 patients who booked CT contrast examination from January 2014 to February 2014 but could not carry out their test on schedule. We analyzed the reasons for the delay and conducted follow-up survey on them. We analyzed the usefulness of pretreatment process system by contemplating and developing pretreatment process system and applying it to the patients for whom follow-up survey was conducted from January 2015 to February 2015. The number of outpatients who came to the hospital form January to February 2014 was 2,846 and the number of patients who could not undergo the test was 214, accounting for 7.52% of the total. The specific reason for the delay includes 214 cases of unknown creatinine 98 with 120 minutes of average delay time, 40 cases of creatinine over 1.3(19%) with 30minutes of average delay time, 34 cases of past contrast media side effect 6% with 40 minutes of average delay time and 25 cases of lack of pretreatment such as fasting, etc. 11% with 120minutes of average delay time. The number of CT scan has been increasing ever since the development of CT and the frequency of using the contrast media is expected to increase. If we can employ pretreatment process system in order to effectively control the side effect of contrast media and help the CT contrast examination to be smoothly conducted on schedule, I'm sure we could improve the quality of our medical service and increase our patients' satisfaction who come to our CT scan room.

A Comparison Study of Signal Intensity of Gadolinium Contrast Media on Fast Spin echo and Ultra Short Time Echo Pulse Sequence at 3T MRI-Phantom Study (3T 자기공명영상 Fast Spin Echo (FSE)와 Ultra Short Time Echo (UTE) 펄스 시퀀스에서 가돌리늄 조영제 희석농도와 신호강도 비교 -팬텀 연구)

  • Lee, Suk-Jun;Yu, Seung-Man
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.253-259
    • /
    • 2015
  • The information of contrast media concentration on target organ is very important to get reduce the side effect and high contrast imaging. We investigated alternation of signal intensity as a function of the modality of Gd-based contrast media on spin echo and ultra short time echo (UTE) of T1 effective pulse sequence at 3T MRI unit. Gadoxetic acid, which is a MRI T1 contrast medium, was used to manufacture an agarose phantom diluted in various molarities, and sterile water and agarose 2% were used as the buffer solution for the dilution. The gold standard T1 calculation was based on coronal single section imaging of the phantom mid-point with 2D Inversion recovery spine-echo pulse sequence MR imaging for testing of phantom accuracy. The 1-2mmol/L and 7mmol/L was shown the maximum signal intensity on spin echo and UTE respectively. We confirm the difference of contrast media concentration which was shown the maximum signal intensity depending on the T1 effective pulse sequence.

Development and Implementation of a Critical Pathway for Prevention of Adverse Reactions to Contrast Media for Computed Tomography (CT 조영제의 부작용 예방을 위한 표준진료지침서의 개발과 적용)

  • Jang, Keun-Jo;Kim, Myeong-Goo;Yoo, Beong-Gyu;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.39-46
    • /
    • 2007
  • The purpose of this study is to develop a critical pathway (CP) for the prevention of adverse reactions to contrast media for computed tomography. The CP was developed and implemented by a multidisciplinary group in Seoul National University Hospital. The CP was applied to CT patients. Patients who underwent CT scanning were included in the CP group from March in 2004. The satisfaction of the patients with CP was compared with non-CP groups. We also investigated the degree of satisfaction among the radiological technologists and nurses. The degree of patient satisfaction with the care process increased patient information(24%), prevention of adverse reactions to contrast media(19%), pre-cognitive effect of adverse reactions to contrast media(39%) and information degree of adverse reactions to contrast media(19%). This CP program can be used as one of the patient care tools for reducing the adverse reactions to contrast media and increasing the efficiency of care process in CT examination settings.

  • PDF