• Title/Summary/Keyword: 조속기

Search Result 125, Processing Time 0.028 seconds

Speed Control of a Diesel Engine by Means of the Model Matching Method (모델 맷칭법에 의한 디젤기관의 속도제어)

  • 유희환;하주식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.3
    • /
    • pp.131-137
    • /
    • 1996
  • The existing digital governors are in the beginning stage. Placing the focus on the marine site, most of the digital governors developed are still using the simple PID algorithm. But, the performance of a diesel engine is widely changed according to the parameters of the PID controller. So, this article describes a new method to adjust the parameters of the PID controller in a marine digital governor. In this paper, the diesel engine is considered as a nonoscillatory second order system. A new method to adjust the parameters of the PID controller for speed control of a diesel engine is proposed by means of the model matching method. Also, the simulations by numerical methods are carried out in cases of the exact understanding or out of the parameters of a diesel engine respectively. And this paper confirms that the proposed new method here is superior to Ziegler & Nichols's method through the comparisons and analysis of the characteristics of indicial responses.

  • PDF

A Simulation for Analysis of Stability of Gas Turbine Governor using PSS/E (가스터빈 조속기의 안정도 해석을 위한 PSS/E 모의 실험)

  • 최인규
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1999.10a
    • /
    • pp.267-271
    • /
    • 1999
  • 연료를 작동 유체의 내부 또는 외부에서 연소시켜서 발생된 고온 고압의 가스를 터빈에 공급하여 회전력을 발생시키는 원동기를 가스터빈이라 하며, 가스터빈을 이용한 발전기와 달리 기동 및 정지 시간이 대단히 짧고, 부하 변화에 대한 속응성이 뛰어나기 때문에 전력계통 운영상 양수 발전기나 수력 발전기와 더불어 첨두 부하용으로 주로 사용된다. 본 고에서는 전력 계통에 병렬 운전 중인 가스터빈 발전기의 부하가 탈락되어 입력 에너지가 과잉으로 되었을 때, 제어 시스템의 중요한 파라미터인 연료량과 가스터빈 속도 및 배기가스의 온도가 비상 정지 수준에 도달하지 않고 안전하게 운전될 수 있는지의 여부, 즉 안정성을 판별하기 위하여 수행한 모의 시험에 대하여 기술하였다. 또, 부하가 탈락되지 않고 입력되는 연료량이 크게 변동하는 경우, 즉 큰 부하 변동을 모의 시험한 내용에 대하여 기술하였다.

  • PDF

The Conditions and Circuits for Synchronous Generator Parallel Operation (동기발전기의 계통병입 운전 조건과 실제 회로구성)

  • Kim, Jong-An;Jung, Chang-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2060-2062
    • /
    • 2001
  • 전기를 에너지원으로 사용하는 각 종 부하는 가정, 공장 및 상가 등에 널리 분산되어 있고, 여기에 전기를 생산 공급하는 발전기도 지역적으로 분산되어 병렬운전이 되고 있다. 새로운 발전기가 병렬운전에 참여하기 위해서는 기존 운전되고 있는 전력계통과의 전압, 주파수, 상회전, 위상이 일치하여야 한다. 만약 이들 조건이 갖추어지지 않은 상태에서 임의 병렬 접속을 시도하게 되면 해당 발전기는 물론 전체 계통에 충격과 손상을 초래할 수 있다. 양측의 전압과 주파수 비교는 상용 계측기를 사용하여 비교적 쉽게 할 수 있느나, 상회전 방향과 위상차의 판별에는 세심한 주의가 필요하다. 최근의 발전기에는 병렬 운전 조건을 자동으로 조정, 확인을 하는 장치를 채용하고 있으며 구체적인 회로구성과 동작원리를 여기에서 살펴보았다. 병렬 접속이 이루어진 후 발전기 별 전력 분담과, 계통 주파수 변동에 따라 자동으로 발전기 출력 제어가 이루어지는 기능이 터빈 조속기 측에 설정되어 사용된다.

  • PDF

일본에서의 변압기의 현황과 장래에 대하여

  • 고교연부
    • 전기의세계
    • /
    • v.26 no.5
    • /
    • pp.18-27
    • /
    • 1977
  • 1952년 초고압 276kV계통이 운전된 이래 약 20년, 이 사이에 전력수요의 증가는 현저하였고, 설치된 변압기의 용량도 증대일로에 있었다. 1973년 5월에는 일본에서 최초의 500kV 방총선이 운전을 개시하고, 신기술의 결집에 의한 500kV변압기의 제작도 백석이하에 이르렀다. 그러나 동년말의 석유파동이래, 전기수요의 신장은 저조하게 되고, 변압기의 생산저하는 현저하여 변압기업계는 대단한 위기에 처하게 되었다. 금후, 기술의 향상은 물론, 일본경제의 조속한 회복과 성장을 기대하며, 안정성장하에 대처함이 중대한 과제이다. 이하, 주로 전력용변압기를 중심으로 특수양상의 기기 및 Reacto등을 약간 곁드리면서 변압기의 현상과 장래에 대하여 언급하기로 한다.

  • PDF

Development of the Robust Speed Controller for Marine Medium Speed Diesel Engines (선박용 중속 디젤 기관의 로바스트 속도제어기 개발)

  • 정병건;양주호;김창화
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.27-35
    • /
    • 1996
  • The ship's propulsion efficiency depends upon a combibation of engine and propeller. The propeller has better efficiency as the engine has lower rotational speed. This situation led the engine manufacures to design the engine that has lower speed, longer stroke and a small number of cylinders. With this new trends the conventional mechanical-hydrualic governors for engine speed control have been replaced by digital speed controllers which adopted the PID control or the optimal control algorithm. But these control algorithms have not enough robustness to suppress the variations of the delay-time and the parameter perturbation especially in low speed engine. In this study we consider the perturbations of the engine parameters as the modeling uncetainties and design a robust speed controller for marine medium speed diesel engine by means of $ extit{H}_{infty}$control theory having the central solution. By comparing the results of the robust speed controller with those of mechanical governor and PID controller, the validity of the robust speed controller under parameter variations is confirmed. The speed control of the experimental diesel engine of carried out using actuator which is composed of PWM signal generator and D.C servo motor.

  • PDF

Development of the Robust Speed Controller for Marine Medium Speed Diesel Engines (선박용 중속 디젤 기관의 로바스트 속도제어기 개발)

  • Jung, B.G.;Yang, J.H.;Kim, C.H.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.349-349
    • /
    • 1996
  • The ship's propulsion efficiency depends upon a combibation of engine and propeller. The propeller has better efficiency as the engine has lower rotational speed. This situation led the engine manufacures to design the engine that has lower speed, longer stroke and a small number of cylinders. With this new trends the conventional mechanical-hydrualic governors for engine speed control have been replaced by digital speed controllers which adopted the PID control or the optimal control algorithm. But these control algorithms have not enough robustness to suppress the variations of the delay-time and the parameter perturbation especially in low speed engine. In this study we consider the perturbations of the engine parameters as the modeling uncetainties and design a robust speed controller for marine medium speed diesel engine by means of $ extit{H}_{infty}$control theory having the central solution. By comparing the results of the robust speed controller with those of mechanical governor and PID controller, the validity of the robust speed controller under parameter variations is confirmed. The speed control of the experimental diesel engine of carried out using actuator which is composed of PWM signal generator and D.C servo motor.

1969년도 전국도서관대회(제8회)

  • Korean Library Association
    • KLA journal
    • /
    • v.10 no.8
    • /
    • pp.2-6
    • /
    • 1969
  • 안으로는 전국 각종 도서관의 당면문재와 진로를 연구 협의하고,밖으로는 우리 도서관계와 학계의 단결된 힘을 과시하며, 나아가서 도서관 사업의 중요성을 관계 요로와 국민에게 인식시킴으로써, 각종 도서관의 조속한 보급을 기함은 물론 봉사의 효율을 증진시켜서 민족문화의 향상과 발전에 이바지하고자 이 대회를 개최한다.

  • PDF

Optimal Governor Response Power Flow with Nonlinear Interior Point Method (비선형 내점법을 이용한 최적 조속기 응동 조류계산)

  • Kim, Tae-Gyun;Lee, Byong-Joon;Song, Hwa-Chang;Cha, Jun-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1527-1534
    • /
    • 2007
  • This paper proposes a new concept of optimal governor-response power flow (OGPF) to obtain an optimal set of control parameters when the systems are in mid-term conditions after disturbances, ignoring the system dynamics. The idea of GOPF simply comes from the attempt to find an optimal solution of the governor-response power flow (GPF), which is a pre-exiting tool that is used to get power flow solutions that would exist several seconds after an event is applied. GPF incorporates the simplified model of governors in the systems into the power flow equations. This paper explains the concept of OGPF and depicts the OGPF formulation and application of a nonlinear interior point method as the solution technique. Also, this paper includes an example with New England 39-bus test system to illustrate the effectiveness of GOPF.

The Analysis about Trouble of GOVERNOR (속도 및 제어시스템의 부조화에 따른 조속기 에러 원인 분석)

  • Ok, Yeon-Ho;Oh, Sueg-Young;Kim, Ki-Won;Byun, Ill-Hwan;Go, Young-Hwan;Im, Seung-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.252-253
    • /
    • 2011
  • Many errors are broken out when hydro power plants are operating connected to electric power system. To minimize ripple effects of accidents, a hydro power plant is separated by a circuit breaker consisting of each protection equipments. In this paper, I will analyze a cause of abnormal events of emergency stop and therefore I take measures and suggest solutions for similar cases.

  • PDF

Model Parameter Determination of Industrial Co-generator Model Parameters through Filed Measurement (현장 계측을 통한 산업용 열병합 발전설비 모델 파라미터 결정)

  • Kim, Hak-Man
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.159-165
    • /
    • 2007
  • This paper presents a method for the derivation of model parameters of a co-generation system using data measured through on-site generator characteristic testing and validates its model parameters. Dynamic models such as generator, excitation system, and turbine/governor are mainly dealt in this paper. For the purpose of validation of derived model parameters, the measured results are compared with simulation results. The comparisons between measured results and simulation results show good match.