LFC Considering the Changing Rate of Governor Speed (조속기 입력의 변화율을 고려한 최적주파수 제어)

  • 박영문;유찬수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.3
    • /
    • pp.100-105
    • /
    • 1984
  • The optimal Load-Frequency Control law is presented with the performance criterion which includes the changing rate of governor speed. The authors propose two controllers. One is a dynamic controller using the method of state augmentation and the other is a constant gain controller with use of the trace function lemma by Kleinman. For a more practical realization, a reduced-order Luenberger observer is applied in order to identify unmeasurable states and power demand. The control schemees presented here are tested through the model developed by Elgerd, and the usefulness is demonstrated.

  • PDF

A Study on the Trouble of Turbine EHC System by Chloride (염소성분에 의한 터빈 EHC계통 손상에 관한 연구)

  • Kim, Seung Min;Yang, Cheon Gyu;Yoon, Gi Nam;Jung, Jae Won;Shin, Yeul Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.366-372
    • /
    • 2000
  • In a power plant, it is generally accepted that a turbine governor system is necessary to control amount of steam supply toward the turbine system. There are many kinds of trouble at this governor system, which is recognized one of the most sensitive systems in the power plant. Especially we have experienced the internal leakage of motorization oil of servo valve. In the study, we investigated the mechanism of an internal leakage such as erosion by foreign materials and corrosion by chemical reaction between chloric healed oil and motorization oil. A precautionary measures is also performed to help the field service engineers.

  • PDF

自動化의 重要性

  • 손명환
    • Journal of the KSME
    • /
    • v.20 no.2
    • /
    • pp.81-83
    • /
    • 1980
  • 자동화라는 것은 1788년에 유명한 James Watt의 증기기관에 있어서 조속기에서 처음으로 찾아볼 수 있다고 하며, 그후도 각종기기에서 부분적인 자동제어화된 예를 볼 수가 있다. 그러나, 현대 적이고 본질적인 자동화는 1914년에 Ford 자동차직립공장에서 흐름적립선을 설치하여 다량생산 방식의 근대산업을 개발하여 생산과정을 진정한 의미로 기계화하고 설인간화하였는데 있다고 하며 현대적감독의 자동화라는 말도 1946년에 출현한 transfer machine에 대하여 사용한 것이 처음이라고 한다 여하간 모든 산업에 있어서의 자동화는 현대산업발전의 촉진제로서 역할을 하여 획기적인 변혁을 가져왔고 경제발전의 원동력으로서의 자리를 굳혔을 뿐 아니라 설안간화, 성 력화의 단계를 넘어서 무인화의 영역에 도전하기에 이르렀다. 자동화 무인화의 영역에 도전하 기에 이르렀다. 자동화의 기술은 초기의 기계적방법을 거쳐서 유압식, 전기전자식으로 발전하였 으며, 현대과학기술의 정화인 전산기와 결합되어 종합과학기술로 발전하였고 앞으로 더욱 가속 화될 것이 기대된다.

  • PDF

50kW Diesel Generator Modeling and Stand-alone Mode Analysis (50kW 디젤발전기 모델링 및 독립운전모드 해석)

  • Lee, Taejin;Jo, Jongmin;Shin, Changhoon;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.147-148
    • /
    • 2015
  • 본 논문에서는 50kW 디젤발전기를 MATLAB/SIMULINK를 이용해 모델링 하였으며, 독립운전을 통해 배터리에 전력을 공급하는 시스템을 시뮬레이션 하였다. 독립운전에서의 디젤발전기 제어기는 주파수를 제어하는 조속기와 전압을 제어하는 여자기로 구성되어 있으며, 액추에이터와 디젤엔진 등은 응답 속도를 고려한 시정수를 갖는 시지연 함수로써 모델링하였다. 디젤발전기에서 CVCF 제어를 통해 BESS(Battery Energy Storage System)에 전력을 공급할 때, 디젤발전기와 BESS 측의 전압 특성을 분석하였다.

  • PDF

Modeling of DFIG based Variable-Speed Pumped Storage Hydro (DFIG 기반의 가변속 양수발전 시스템 모델링)

  • Liu, Zhenqian;An, Hyunsung;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.15-17
    • /
    • 2018
  • 본 논문은 DFIG기반의 가변속 양수발전소의 조속기, 터빈-수압관(penstock), 발전기/컨버터 및 시스템 제어기를 모델링하였으며, 발전기/컨버터 모델은 하나의 전류원과 임피던스로 등가화 되었다. 최적 운전 조건을 위한 터빈의 속도와 게이트 위치 지령치는 시스템 제어기를 통해서 얻을 수 있으며, 계통 전력의 지령치를 통해서 발전기/컨버터 모델의 전류 지령치를 만들며. 터빈 회전속도와 게이트 위치는 DFIG의 속도와 지령 속도의 비교를 통해 출력된다. 시뮬레이션 모델링을 통해 전력의 지령치 변화에 따라 계통의 전력과 터빈의 응답성을 확인하였다.

  • PDF

Design of Robust Fuzzy Controller for Load-Frequency Control of Power Systems Using Intelligent Digital Redesign Technique (지능형 디지털 재설계 기법을 이용한 전력 계통의 부하 주파수 제어를 위한 강인한 퍼지 제어기 설계)

  • Joo, Young-Hoon;Jeo, Sang-Won;Kwon, Oh-Sin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.10 no.4
    • /
    • pp.357-367
    • /
    • 2000
  • A new robust load-frequency control methodology is proposed for nonlinear power systems with valve position limits of the governor in the presence of parametric uncertaines. The TSK fuzzy model is adopted and formulated for fuzzy modeling of the nonlinear power system. A sufficient condition of the robust stabilitry is presented in the sense of lyapunov for the TSK model with parametric uncertainties. The intekkigent digital redesign technique for the uncertain power systems is also studied. The effectiveness of the robust digital fuzzy controller disign mothod is demonstrated through a numerical simulation.

  • PDF

Passivity-based Control Approach of Exciter and Governor Systems for Synchronous Electric Generators (Passivity 기반 동기 발전기의 여자기 및 조속기 시스템의 제어 기법)

  • Cho, Hyun Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.4
    • /
    • pp.561-568
    • /
    • 2018
  • Passivity theory is significantly applied to analyze stability of nonlinear dynamic systems and construct its stable control systems. This paper presents a passivity based control design approach for exciters and governors which are employed to regulate the terminal voltage and the rotor velocity of synchronous generator systems in industry fields. We consider the IEEE type 1 exciter and the gas turbine (GT) governor models respectively in this paper. We first carry out a passivity analysis for exciter and governor control systems, which are numerically obtained from its mathematical models. And then its control parameters are selected to assure passivity conditions in a design procedure. Lastly, we investigate numerical simulations to demonstrate reliability of the proposed control approach against large-scale generators with parameter changes.

A Study on the Hydraulic Turbine Governor using Automatic Tuning Fuzzy Controller (자동 동조 퍼지 제어기를 이용한 수력 발전소 조속기 연구)

  • Lee, Seon-Geun;Lee, Won-Yong;Shin, Dong-Ryul;Kwon, Oh-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.265-268
    • /
    • 1992
  • The control performances of a fuzzy controller depend on its control rules, I/O membership functions, and scaling factors. Scaling factors are very important to adjust control parameters to the process which is to be controlled. For tuning the sealing factors, trial and error method is used in conventional fuzzy controller, which is very difficult and time consuming. This paper proposes a tuning method of scaling factors based on the concept of tuning rules for the conventional Pl controller parameters. The proposed automatic tuning fuzzy controller was evaluated by computer simulations. Good results have been obtained for the small hydro power plant.

  • PDF

A Comparative Study of Gas Turbine Models for the Enhancement of Power System Stability (전력계통 과도안정도 향상을 위한 가스터빈 모델링 비교 연구)

  • Kim, Dong-Joon;Lee, Joon-Joo;Moon, Young-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.229-230
    • /
    • 2015
  • 본 논문은 전력계통 과도안정도 해석에서 많이 쓰이고 있는 가스터빈 모델인 GAST 모델과 GAST2A 모델에 대해서 과도안정도 관점에서 모의 비교한다. 두 가스터빈 모델은 1기 무한모선으로 계통을 구성하여 정상상태에서 조속기 10% 스텝응동 특성을 모의하여 서로 응동특성이 같도록 모델정수를 튜닝하였다. 그리고 발전단에 150 ms 3상 단락사고를 발생시켜 과도상태 특성을 비교하였다. 3상 단락사고인 경우 배기가스 온도제한이 없는 정상 출력상태인 경우와 온도제한 제어특성이 활성화 되는 출력인 경우를 상정하여 비교 분석하였다.

  • PDF

Modeling of Variable-Speed Pumped Storage Hydro (가변속 양수발전 시스템 모델링)

  • Liu, Zhenqian;An, Hyunsung;Song, Wooseok;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.350-351
    • /
    • 2018
  • 본 논문은 가변속 양수발전 시스템의 모델링 및 양수발전용 전력변환장치 제어 구조를 분석하고 모델링하였다. 기존 양수발전 시스템은 동기 발전기를 사용하였지만 신재생 에너지원의 출력 변동 및 부하 변동에 따른 주파수의 변화에 빠른 대응을 위한 가변속 양수발전 시스템을 채용하여 계통 전력과 전압, 주파수 등을 보상한다. 양수 발전소의 터빈, 게이트, 조속기 등을 분석하여 모델링하였으며, Doubly fed induction generator를 위한 back-to-back 전력 변환 장치를 발전 및 양수 모드에 사용하기 위해 벡터제어, 속도제어, 유효-무효 전력 제어기 등을 모델링 하였다.

  • PDF