• Title/Summary/Keyword: 조사선량율

Search Result 509, Processing Time 0.02 seconds

High Energy Photon Beam Modeling Using Transport Theory for Calculation of Absorbed Dose Distribution (흡수 선량 분포의 수송방정식을 이용한 10 MV X-선의 모델)

  • Choi, Dong-Rak;Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.115-120
    • /
    • 1992
  • A mathematical model is presented for the calculation of the depth absorbed dose in water Phantom irradiated by high energy Photon beam (10MV X-ray), based on transport theory. The parameters of this model are obtained from the experimental values which were simulated by non-linear regression process method. The calculated absorbed dose distribution is extended to 3-D by using trial function from beam profile field sizes, SSD and depth in water phantom irradiated by high energy Photon beam. The calculated values using this model are in good agreement with the measured values.

  • PDF

Effects of Water Soaking and Gamma Irradiation on Storage Quality of Chestnuts (수침 및 감마선 처리가 밤의 저장특성에 미치는 영향)

  • 권중호;이정은;이새봄;정헌식;최종욱
    • Food Science and Preservation
    • /
    • v.8 no.1
    • /
    • pp.9-15
    • /
    • 2001
  • The effects of water soaking and gamma irradiation on the storage quality of chestnuts (Castanea crenata) were investigated. Chestnuts weirs soaked in water for 48 hrs at room temperature, irradiated at 0, 0.15, 0.25 and 0.35 kGy of $\^$60/Co gamma ray, and then stored at 0$\^{C}$ and 95$\pm$2% RH for 9 months. Spouting was observed at the end of storage only in chestnuts that were soaked and irradiated at below 0.25 kGy. Rotting was found from the early stage of storage in all pre-treatment conditions, but the rotting rate of soaked chestnuts was higher twice than unsoaked ones after 9 months of storage. Weight loss was lower in soaked than unseated samples regardless of irradiation dose. Loss of flesh firmness was appreciably retarded as irradiation dose increased. Total sugar content decreased slowly in irradiated samples at the later periods of storage. Gamma irradiation resulted in the decrease of vitamin C content immediately after treatment, but retarded its loss rate during storage. Soluble tannin content was not affected by gamma irradiation at scout inhibition doses.

  • PDF

Comparison between the Calculated and Measured Doses in the Rectum during High Dose Rate Brachytherapy for Uterine Cervical Carcinomas (자궁암의 고선량율 근접 방사선치료시 전산화 치료계획 시스템과 in vivo dosimetry system 을 이용하여 측정한 직장 선량 비교)

  • Chung, Eun-Ji;Lee, Sang-Hoon
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.396-404
    • /
    • 2002
  • Purpose : Many papers support a correlation between rectal complications and rectal doses in uterine cervical cancer patients treated with radical radiotherapy. In vivo dosimetry in the rectum following the ICRU report 38 contributes to the quality assurance in HDR brachytherapy, especially in minimizing side effects. This study compares the rectal doses calculated in the radiation treatment planning system to that measured with a silicon diode the in vivo dosimetry system. Methods : Nine patients, with a uterine cervical carcinoma, treated with Iridium-192 high dose rate brachytherapy between June 2001 and Feb. 2002, were retrospectively analysed. Six to eight-fractions of high dose rate (HDR)-intracavitary radiotherapy (ICR) were delivered two times per week, with a total dose of $28\~32\;Gy$ to point A. In 44 applications, to the 9 patients, the measured rectal doses were analyzed and compared with the calculated rectal doses using the radiation treatment planning system. Using graphic approximation methods, in conjunction with localization radiographs, the expected dose values at the detector points of an intrarectal semiconductor dosimeter, were calculated. Results : There were significant differences between the calculated rectal doses, based on the simulation radiographs, and the calculated rectal doses, based on the radiographs in each fraction of the HDR ICR. Also, there were significant differences between the calculated and measured rectal doses based on the in-vivo diode dosimetry system. The rectal reference point on the anteroposterior line drawn through the lower end of the uterine sources, according to ICRU 38 report, received the maximum rectal doses in only 2 out of the nine patients $(22.2\%)$. Conclusion : In HDR ICR planning for conical cancer, optimization of the dose to the rectum by the computer-assisted planning system, using radiographs in simulation, is improper. This study showed that in vivo rectal dosimetry, using a diode detector during the HDR ICR, could have a useful role in quality control for HDR brachytherapy in cervical carcinomas. The importance of individual dosimeters for each HDR ICR is clear. In some departments that do not have the in vivo dosimetry system, the radiation oncologist has to find, from lateral fluoroscopic findings, the location of the rectal marker before each fractionated HDR brachytherapy, which is a necessary and important step of HDR brachytherapy for cervical cancer.

Bolus Effect to Reduce Skin Dose of the Contralateral Breast During Breast Cancer Radiation Therapy (유방암 방사선치료 시 반대편 유방의 피부선량 감소를 위한 볼루스 효과)

  • Won, Young Jin;Kim, Jong Won;Kim, Jung Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.289-295
    • /
    • 2017
  • The aim of this study was to evaluate the dose comparison using Radon phantom with 5 mm and 10 mm tissue equivalent materials, FIF, Wedge(15, 30 angle) and IMRT, to reduce the skin dose of the contralateral breast during breast cancer radiation therapy(Total dose: 50.4Gy). The dose was measured for each treatment plan by attaching to the 8 point of the contralateral breast of the treated region using a optical-stimulated luminance dosimeter(OSLD) as a comparative dose evaluation method. Of the OSLD used in the study, 10 were used with reproducibility within 3%. As a result, the average reduction rates of 5 mm and 10 mm in the FIF treatment plan were 37.23 cGy and 41.77 cGy, respectively, and the average reduction rates in the treatment plan using Wedge $15^{\circ}$ were 70.69 cGy and 87.57 cGy, respectively. The IMRT showed a reduction of 67.37 cGy and 83.17 cGy, respectively. The results of using bolus showed that as the thickness of the bolus increased in all treatments, the dose reduction increased. We concluded that mastectomy as well as general radiotherapy for breast cancer would be very effective for patients who are more likely to be exposed to scattered radiation due to a more demanding or complex treatment plan.

Effect of Low Dose ${\gamma}$ Radiation on the Dormancy and Growth of in vitro Microtuvers of Potato(Solanum Tuberosum L.) (저선량 ${\gamma}$선이 기냐 생산된 감자 소괴경의 휴면과 생에 미치는 효과)

  • Kim, Dong-Hee;Back, Myung-Hwa;Jeon, Jae-Heung;Kim, Jae-Sung
    • Korean Journal of Environmental Biology
    • /
    • v.19 no.4
    • /
    • pp.270-277
    • /
    • 2001
  • To observe the stimulating effect of low dose ${\gamma}$ radiation on the dormancy breaking and growth, microtubers induced in vitro of two potato (Solanum tuberosum L. cv. Dejima and cv. Superior) cultivars with different storage duration were irradiated with ${\gamma}$ radiation at the dose of $0.5{\sim}30$ Gy. Sprouting rate, growth and tuber yield of ‘Dejima’ microtuber were increased by ${\gamma}$ radiation in the range of $2{\sim}16$ Gy. In the microtuber of ‘Superior’, the sprouting rate was promoted by 2 Gy and 4 Gy irradiation, and the growth and tuber yield by 0.5 Gy and 4 Gy irradiation. There were not that much difference in chlorophyll content of potato plantlet by the low dose ${\gamma}$ irradiation. These results suggested that low dose ${\gamma}$ radiation stimulated the dormancy breaking and potato growth.

  • PDF

A Study on the Variation of Transmission Factors, Output Factors and Percent Depth Doses by Wedge Filters for 4~10 MV X-Ray Beams (4~10 MV X-선의 쐐기 (wedge) 필터의 투과율과 출력계수, 선축상 선량분포의 변화에 관한 연구)

  • 강위생
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.3-17
    • /
    • 1997
  • Because a wedged beam consists of attenuated primary photons and scattered radiations from wedge, the spectrum of the wedged beam does not coincide with that of an open beam with same geometry. The aims of current report are to get exact information about whether effects of 15-60$^{\circ}$ wedge for 4 -10 MV photon beams should be considered for dose calculation or not, and to suggest a reference condition for measurement of wedge transmission factor. Percent depth dose of both open and wedged fields with angles of 15, 30, 45, 60$^{\circ}$ for beams of 4 MV(Clinac 4/100, Varian), two 6 MV(Clinac 6/100 and Clinac 2100C, Varian), 10 MV(Clinac 2100C, Varian) X-rays were measured to 30cm deep in water using ionization chambers. Hardening factors of photon beams were calculated with measured PDDs. Both field size factors and transmission factors of wedge filters were measured at d$_{max}$ in water. Beam hardening factors of wedged fields of 4 and 6 MV X-ray were larger than 1 for all wedge angles, field sizes and depths deeper than d$_{max}$ Beam hardening factors for wedge angles 15, 30, 45, 60$^{\circ}$ for 10$\times$10cm were respectively 1.010, 1.014, 1.023 and 1.034 for 4MV X-ray, 1.005, 1.008, 1.019, and 1.024 for 6MV X-ray of Clinac 6/100, 1.011, 1.021, 1.032, 1.036 for 6MV X-ray of Clinac 2100C, and 1.008, 1.012, 1.012 and 1.012 for 10MV X-ray. Beam hardening factors of 10MV X-ray were 1 within 1.2% difference for all wedge angles, depths and field sizes. It was made clear that for 6MV X-rays, the beam hardening factor depends on treatment machine. The relationship of the factor and depth was linear. Field size factor at d$_{max}$ was independent of wedge angle except for the field of 15$\times$15cm. and maximum difference of the field size factors for the field size was 1.4% for 4MV X-ray. When the wedge factor is determined, dependence of the factor on field size is negligible at d$_{max}$ but should be considered at deeper depth. Calculating dose distribution or MU, the beam hardening factor should be applied for 4~6MV X-ray beams, but might not be considered for 10MV beam. When wedge transmission factor was determined at d$_{max}$ or in air, field size factors for open field are also applicable to wedged fields, but otherwise, field size factor for each wedge or wedge factor depending on field size should be applied.

  • PDF

4-Dimensional Imaging and Planning (4차원 영상 및 치료계획)

  • Jo, Byeong-Cheol;Park, Hui-Cheol;Kim, Su-San;O, Do-Hun;Bae, Hun-Sik
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.11-15
    • /
    • 2005
  • 입체조형 및 세기조절 방사선치료가 보편화되어 가고 있는 현 시점에서, 치료율을 높이기 위해 종양처방선량은 증가시키는 반면 부작용은 최소화하고자 하는 요구가 증가하고 있다. 셋업오차 및 체내운동(internal motion)은 이러한 요구를 충족시키는데 대한 한계로 작용하고 있다. 4차원방사선치료(4-dimensional radiation therapy)는 체내운동을 최소화시키거나 또는 움직임을 추적하여 방사선치료를 시행함으로써 “종양선량최대화/정상조직선량최소화”라는 고정밀방사선치료의 요구에 부응할 수 있는 치료기술로 기대를 모으고 있다. 체내운동은 호흡에 의한 움직임과 같이 단기적으로 발생되는 조사분할내(intra-fraction)와 종양의 수축, 체중 변화 등과 같이 장기적으로 발생하는 조사분할간(inter-fraction)움직임으로 구분되는데, 본 연제에서는 주로 조사분할내 움직임, 즉 호흡에 의한 움직임에 대처하는 4차원방사선치료를 위한 동적영상 획득 및 방사선치료계획과정에 초점을 맞추어 소개하고자 한다.

  • PDF

Cancinoma of Uterine Cervix Treated wvith High Dose Rate Intracavitary Irradiation : 1 Patterns of Failure (자궁경부암의 고선량율 강내치료후 실패양상에 대한 고찰)

  • Kim Ok Bae;Choi Tee Jin;Kim Jin Hee;Lee Ho Jun;Kim Yung Ae;Suh Young Wook;Lee Tae Sung;Cha Soon Do
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.369-376
    • /
    • 1993
  • 226 patients with carcinoma of the uterine cervix treated with curative radiation therapy at the Department of Therapeutic Radiology, Dongsan hospital, Keimyung university, School of medicine, from July,1988 to May,1991 were evaluated. The patients with all stages of the disease were included in this study. The maximum and mean follow up durations were 60 and 43 months. The radiation therapy consisted of external irradiation to the whole pelvis (2700~4500 cGy) and boost parametrial doses (for a total of 4500~6300 cGy)with midline shild $(4{\times}10\;cm),$ and combined with intracavitary irradiation (5700~7500 cGy to point A). The distribution of patients according to the stage was as follows: stage IB 37 $(16.4\%),$ stage IIA 91 $(40.3\%),$ stage IIB 58 $(25.7\%),$ stage III 32 $(13.8\%),$ stage IV 8 $(3.5\%).$ The overall failure rate was $23.9\%$ (54 patients). The failure rate increased as a function of stage from $13.5\%$ in stage IB to $15.4\%$ in stage IIA, $25.9\%$ in stage IIB, $46.9\%$ in stage III, and $62.5\%$ in stage UV. The pelvic failure alone were 32 patients and 11 patients were as a components of other failure, and remaining 11 patients had distant metastasis only. Among the 43 patients of locoregional failure,28 patients were not controlled initially and in other words nearly half of total failures were due to residual tumor. The mean medial paracervical (point A) doses were 6700 cGy in stage IIB,7200 cGy in stage IIA,7450 cGy in stage IIB,7600 cGy in stage III and 8100 cGy in stage IV. The medial paracervical doses showed some correlation with tumor control rate in early stage of disease (stage Ib, IIA), but there were higher central failure rate in advanced stage in spite of higher paracervical doses. In advanced stage, failure were not reduced by simple increment of paracervical doses. To improve a locoregional control rate in advanced stages, it is necessary to give additional treatment such as concomitant chemoradiation.

  • PDF

Effects of X-ray Irradiation on the Survival Rate and Weight of the Rhinoceros Beetle Larvae (X선 이 장수풍뎅이 유충의 체중과 생존율에 미치는 영향)

  • Lee, Won-Jeong;Lim, Dong-Hwan;Park, Jeong-Soon;Sim, Yeung-Eun;Jeong, Yoo-Jin;Kim, Jeong Ho;Yoo, Se Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.271-277
    • /
    • 2020
  • The Purpose of this study was to examine the survival rate and weight of rhinoceros beetle larvae by irradiating X-rays which are most commonly used in diagnosing and treating for diseases. Subjectts and Methods: In early April 2019, the rhinoceros beetle larvae 41 were classified into two groups as control group (11 larvae) and irradiated group (10 Gy, 20 Gy, 30 Gy, each 10 larvae). The irradiated group was exposed by 6 MV X-ray using linear accelerators (Clinac IS, VERIAN, USA) at the University Hospital in Daejeon (Source-surface distance 96 cm, field size 18 × 10 cm, dose rate 600 MU/min), after environmental adaptation for 3 days (temperature 20.6℃, humidity 64.3%). The survival rate and weight were measured weekly after irradiating X-ray. All statistical analyses were performed using the SPSS ver. 22.0 (Chicago, IL, USA). The weight was analysed by Independent T-test, by cross-sectional analysis for survival rates between control and X-ray irradiated groups. Also, the correlation between dose and weight was analyzed by Spearman test. In 3-week after irradiating X-ray, weight was significant difference between control group and irradiated group (10 Gy or 20 Gy, p < 0.05; and 30 Gy, p < 0.01) with increasing weight in all experimental groups. In 14-week, weight was increased in the control group, but decreased in irradiated group. weight was significant difference between control group and irradiated group. The survival rate in 3-week was decreased rapidly in all experimental group except 10 Gy, to 4-week in irradiated group. The control group had no change in survival rate 54.5% from 3-week to 14-week. From the 3-week, it showed lower survival rate with increasing radiation dose in irradiated group. In 19-week, survival rate of control group and 10 Gy was 45.4% and 30.0% respectively, all died in 20 Gy and 30 Gy. Weight was significantly negative correlated with radiation dose as longer time after irradiating X-ray. The weight and survival rate of rhino beetle larvae is affected by irradiating X-rays, weight and survival rate decreased more in higher dose.

A Study on the Food Consumption Rates for Off-site Radiological Dose Assessment around Korean Nuclear Power Plants (국내 원자력발전소 주변 주민의 방사선량 평가를 위한 음식물 섭취율 설정 연구)

  • Lee, Gab-Bock;Chung, Yang-Geun
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.4
    • /
    • pp.183-196
    • /
    • 2008
  • The internal dose by food consumption mostly accounts for radiological dose of public around nuclear power plants (NPPs). But, food consumption rates applied to off-site dose calculation in Korea which are the result of field investigation around Kori NPP by the KAERI (Korea Atomic Energy Research Institute) in 1988, are not able to reflect the latest dietary characteristics of Korean. The food consumption rates to be used for radiological dose assessment in Korea are based on the maximum individual of US NRC (Nuclear Regulatory Commssion) Regulatory Guide 1.109. However, the representative individual of the critical group is considered in the recent ICRP (International Commission on Radiological Protection) recommendation and European nations' practice. Therefore, the study on the re-establishment of the food consumption rates for individual around nuclear power plant sites in Korea was carried out to reflect on the recent change of the Korean dietary characteristics and to apply the representative individual of critical group to domestic regulations. The Ministry of Health and Welfare Affairs has investigated the food and nutrition of nations every 3 years based on the Law of National Health Improvement. The statistical data such as mean, standard deviation, various percentile values about food consumption rates to be used for the representative individual of the critical group were analyzed by using the raw data of the national food consumption survey in $2001{\sim}2002$. Also, the food consumption rates for maximum individual are re-estimated.