• Title/Summary/Keyword: 조명 균질도

Search Result 12, Processing Time 0.019 seconds

Development and Evaluation of an Indirect Illumination for Tongue Image Acquisition (설 영상 획득을 위한 간접 조명 구현 및 평가)

  • Jung, Chang Jin;Kim, Keun Ho;Jang, Jun-Su;Jeon, Young Ju
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.11
    • /
    • pp.221-228
    • /
    • 2014
  • The color and shape of the tongue reflect the physiological and clinico-pathological condition of the body. Recently, various tongue image acquisition devices have been developed for accurate diagnosis based on quantitative and objective tongue features. Since a color information is essential for tongue diagnosis, the performance of an illuminator is very important for the tongue image acquisition device. In this study, we developed an indirect illumination, which is possible to improve a homogeneity of light intensities on the tongue surface, and evaluated its performances. In order to realize the indirect illumination (II), a semi-ellipsoidal solid structure (SESS) for the light reflex was located in the system, and two high-brightness white LEDs were placed for illuminating the areas under frontal camera in the SESS. The tongue surface was illuminated by reflected light from the SESS. The light homogeneity induced by three different illuminations including the II was evaluated by calculating coefficient of variation (CV) of illuminance of five regions. The II showed less than 0.01 of CV and the direct illumination (DI) and the direct illumination with a light diffusion plate (DILDP) showed 0.16 and 0.13, respectively. The reflexed pixel ratios of tongue phantom images show 5.76%, 4.22%, 1.79% for the DI, the DILDP and the II, respectively. The homogeneity of a tongue phantom was evaluated by calculating CV of mean pixel values of six different tongue regions, and showed less than 0.06 in the II. If the II technique apply to tongue diagnosis system, it is expected to improve diagnostic accuracy in clinic.

Capacitively Coupled Radio Frequency Discharge System for Excitation of Gas Laser (기체레이저의 여기를 위한 용량결합고주파(ccrf) 방전시스템)

  • Choi, Sang-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.19-26
    • /
    • 2006
  • The ccrf-discharge has in comparison with the hollow-cathode discharge and DC-discharge some advantages: Simple design of the tube and homogeneous plasma. The ccrf-discharge was researched with the goal, to use on the excitation of the gas laser. In this work a rf-exciting system was planned and developed. With it a homogeneous discharge was produced in the cw operation. To supply the rf-power with the frequency 13.56[MHz] effectively in the discharge, laser tube were used with inner diameter of 5[mm] and the specially developed rf-electrodes. A matching circuit was composed also. Thereby the impedance of the discharge tube was adjusted to the 50[$\Omega$] output resistance of the rf-source.

A Study on the Magnetic Fields Measurement of Radio-Frequency Induction Coupled Plasma (고주파 유도 결합 플라즈마의 자기장 계측에 관한 연구)

  • 하장호;전용우;전재일;김기채;박원주;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.52-54
    • /
    • 1997
  • 고주파 유도결합 플라즈마(RFICP)에서 루우프법에 의해 자기장특성을 계측하였다. 자기장 계측은 플라즈마의 거시적 변화를 시간적으로 접근하며, 반도체 프로세스의 관건인 균일하고, 고집적인 분포를 얼마나 교란, 응집하는가를 검증하고, 밀도와의 관계를 비교, 분석하여 방적의 최적화를 규명할 수 있을 것이다. 작은 루우프 안테나($\Phi$:외경 7.5mm)는 RF 자기장의 크기와 방향을 결정하기 위해 방전속에 삽입된다. 자기장의 세기는 전형적으로 입력파워 50 - 500 [W]에 대해 0.1에서 2.5 G 사이로 변화하였다. 사용가스는 아르곤가스(99.9% 고순도)를 사용하였으며, 동작압력은 20 [mTorr] 에서 15 [sccm]까지하였다. 반경방향의 공간분포에서는 아스펙트비(aspect ratio : R/L)를 2로 하여 자기장 분포를 계측하였다. 자기장은 입력파워의존성에 대해서 200 [W]까지 상승하고, 300[W]에서 안정성을 지속한다. 압력에 대한 의존성은 300[W]에서 60 [mTorr]이상 일 때는 플라즈마의 균질한 압력상태를 벗어남을 보인다. 아르곤 가스유량에 대해서는 무거운 중성기체입자가 자기장의 영향을 거의 받지 않기 때문에 일정한 경향이 나타났다. 반경방향의 공간분포 측정에서는 자기장은 RFICP의 대구경 특성에 맞게 전체적으로 일정한 분포를 이루고 있음을 확인하였다. 이러한 결과로부터 고주파유도결합 플라즈마에서의 동작생성, 유지기구등의 파악에 도움이 될 것이다.

  • PDF

TEM Sample Preparation of Heterogeneous Materials by Tripod Polishing and Their Microstructures (Tripod Polishing을 이용한 불균질 재료의 TEM 시편준비 방법과 미세조직 관찰)

  • Kim, Yeon-Wook;Cho, Myung-Ju
    • Applied Microscopy
    • /
    • v.34 no.2
    • /
    • pp.95-102
    • /
    • 2004
  • The TEM samples prepared by ion milling have the advantage that thin area can be obtained from almost any materials. However, it has the disadvantage that the amount of thin area can often be quite limited. For the cross-sectioned samples and grossly heterogeneous materials, the thickness of less than $0.1{\mu}m$ can be achieved by mechanical grinding and polishing (tripod polisher) and then the TEM samples may be ion-milled for final thinning or cleaning. These approaches were described in this paper. Examples of TEM observations were taken from cross-section samples of thin films on silicon and sapphire, from diffusion layers between $Mo_5Si_3\;and\;Mo_2B$, and from rapidly solidified 304 stainless steel powders embedded in electroplated copper.

Visualization and Electrical Response of Electroconvective Vortices on the Surface of Homo/Heterogeneous Ion Exchange Membranes (이온교환막의 균질/비균질 표면 형상에 따른 전기 와류 가시화 및 전기적 특성 분석)

  • Myeonghyeon Cho;Jinwoong Choi;Bumjoo Kim
    • Korean Journal of Materials Research
    • /
    • v.33 no.1
    • /
    • pp.21-28
    • /
    • 2023
  • The electromembrane process, which has advantages such as scalability, sustainability, and eco-friendliness, is used in renewable energy fields such as fuel cells and reverse electrodialysis power generation. Most of the research to visualize the internal flow in the electromembrane process has mainly been conducted on heterogeneous ion exchange membranes, because of the non-uniform swelling characteristics of the homogeneous membrane. In this study, we successfully visualize the electro-convective vortices near the Nafion homogeneous membrane in PDMS-based microfluidic devices. To reinforce the mechanical rigidity and minimize the non-uniform swelling characteristics of the homogeneous membrane, a newly developed swelling supporter was additionally adapted to the Nafion membrane. Thus, a clear image of electroconvective vortices near the Nafion membrane could be obtained and visualized. As a result, we observed that the heterogeneous membrane has relatively stronger electroconvective vortices compared to the Nafion homogeneous membranes. Regarding electrical response, the Nafion membrane has a higher limiting current and less overlimiting current compared to the heterogeneous membrane. Based on our visualization, it is assumed that the heterogeneous membrane has more activated electroconvective vortices, which lower electrical resistance in the overlimiting current regime. We anticipate that this work can contribute to the fundamental understanding of the ion transport characteristics depending on the homogeneity of ion exchange membranes.

Electrical Resistivity-Measurements for the Detection of Fracture Zones in the Woraksan Granitic-Bodies (월악산화강암체의 파쇄대규명을 위한 전기비저항탐사)

  • 김지수;권일룡
    • The Journal of Engineering Geology
    • /
    • v.7 no.2
    • /
    • pp.113-126
    • /
    • 1997
  • Electrical resistivity methods of dipole - dipole array profiling and Schiumberger array sounding were tested on a segment of the Woraksan granitic batholith for the research into the imaging of irregular attitudes of fracture zones in the crystaaline rock in terms of processing and interpretation schemes. By the dipole - dipole array method, inhomogeneities such as small scale of fracture zones were properly delineated down at some depth even within hard rock environment. Fracture zones were interpreted to be at the boundaries between the high amplitude zone and very low amplitude zone in the resistivity plot and they were also successfully outlined in two - dimensional layer and pseudo - three - dimensional volume constructed by the incorporation of vertical sounding data. The surface location of the fracture zones was correlated by the zero - crossing point in the VLF(very low frequency) electromagnetic data. Pseudo - three - dimensional attitudes of fracture zones were efficiently illuminated by optimum projection angle. The mean of bulk resistivity for the Woraksan granite and the near fracture zones is estimated to be approximately of 4,000 ohm - m which is much higher than the value of 700 ohm - m for the Rwachunri limesilicate environment. This difference is due to both the rock type, i.e., biotite granite vs limesilicate, and the occurrence of secondary openings of fold and fault associated with the intrusion of granite. In this study statistical analyses on the resistivity color plot were performed in terms of three representative statistical moments, i.e., standard deviation, skewness, and kurtosis. The fracture zones in the standard deviation plot were characterized by the higher value, compared to the value of homogeneous portion. The upper boundary of the high resistivity zone was also successfully delineated in the skewness and kurtosis plots.

  • PDF

Analyses of Hazard Voltages According to the Buried Depth of Small-sized Model Grounding Electrode (축소형 모델 접지전극의 매설깊이에 따른 위험전압의 분석)

  • Paek, Young-Hwan;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.56-61
    • /
    • 2009
  • This paper presents the ground surface potential profiles and hazard voltages around the metallic structure connected to a small-sized model ground electrode. Because it is very difficult to draw valid conclusions concerning a general grounding problem from actual field data, scale model tests can be used to determine the touch and stop voltages and surface potential profiles around ground electrode. In this work, a hemispherical vessel with a diameter of 1,100[mm] was employed to simulate uniform soil. As a result, the ground surface potential around the ground electrode was significantly raised In particular the ground surface potential at the just upper point of ground rod was higher than other points. When the buried depth of ground rod is increased, the ground surface potential and step voltage were lowered but the touch voltage was elevated.

Evaluations of Dangerous Voltages around Grounding Electrode using Small-sized Model (축소모델을 이용한 접지전극 주변의 위험전압 평가)

  • Baek, Young-Hwan;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.83-88
    • /
    • 2010
  • In this paper, to propose a valid method solving a problem relevant to grounding from actual field data, the experimental results relevant to touch and step voltages and surface potential profiles measured around the real-sized and small-sized grounding electrode models were described. The ground surface potential profiles and dangerous voltages around the concrete pedestals employed in street facilities such as street lamps, traffic signal lamp and controllers as a case study were measured and discussed. The hemispherical cell with a diameter of 1,160[mm] was employed to simulate uniform soil. As a result, the results measured with the small-sized model were in reasonably agreement with the data obtained from the real-sized installation. It was found that the small-sized model test could be employed as a useful means evaluating the dangerous voltages around grounding electrodes installed at the inaccessible areas such as mountains, underground, underwater, and so on.

LED Beam Shaping and Fabrication of Optical Components for LED-Based Fingerprint Imager (LED 빔조형에 의한 초소형 이미징 장치의 제조 기술)

  • Joo, Jae-Young;Song, Sang-Bin;Park, Sun-Sub;Lee, Sun-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.10
    • /
    • pp.1189-1193
    • /
    • 2012
  • The Miniaturized Fingerprint Imager (MFI) is a slim optical mouse that can be used as an input device for application to wireless portable personnel communication devices such as smartphones. In this study, we have fabricated key optical components of an MFI, including the illumination optical components and imaging lens. An LED beam-shaping lens consisting of an aspheric lens and a Fresnel facet was successfully machined using a diamond turning machine (DTM). A customized V-shaped groove for beam path banding was fabricated by the bulk micromachining of silicon that was coated with aluminum using the shadow effect in thermal evaporation. The imaging lens and arrayed multilevel Fresnel lenses were fabricated by electron beam lithography and FAB etching, respectively. The proposed optical components are extremely compact and have high optical efficiency; therefore, they are applicable to ultraslim optical systems.

Dispersion of ZrO2 by Coprecipitation in Al2O3/ZrO2Ceramics (Al2O3/ZrO2요업체에서 공침에 의한 ZrO2입자의 분산)

  • Cho, Myung-Je;Choi, Jung-Lim;Park, Jung-Kwon;Hwang, Kyu-Hong;Lee, Jong-Kook
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.7
    • /
    • pp.704-709
    • /
    • 2002
  • To improve the mechanical properties of $Al_2$O$_3$/ZrO$_2$composites, the homogeneous dispersion of ultra low size ZrO$_2$ particles in $Al_2$O$_3$ceramics have been controlled by coprecipitation method. In case of mechanical mixing of ZrO$_2$ powders with $Al_2$O$_3$, homogeneous dispersion and controlling the ZrO$_2$ size were relatively difficult due to high sintering temperature. So nanosized Zr hydroxide was coprecipitated from ZrOCl$_2$/Y(NO$_3$)$_3$ solution with commercial sub-micron sized $\alpha$-alumina (Sumitomo : AES-11(0.4 ${\mu}{\textrm}{m}$)) and high purity ultra low sized $\alpha$-alumina (Taimei Chemical (0.22 ${\mu}{\textrm}{m}$)) for low temperature sintering. By this partial coprecipitation method, relatively low sized ZrO$_2$ dispersion in $Al_2$O$_3$/ZrO$_2$ composites was achieved at 150$0^{\circ}C$-1$600^{\circ}C$ of sintering temperature range and their mechanical properties were measured.