• Title/Summary/Keyword: 조명계통

Search Result 460, Processing Time 0.029 seconds

A Tuning Method for the Power System Stabilizer of a Large Thermal Power Plant and Its Application to Real Power System : Part I-Selection of Parameters by Off-line Simulation (대형 화력발전기 전력계통 안정화장치의 정수선정 기법과 실계통 적용 : PART I-오프라인 해석을 통한 PSS 정수 선정)

  • Shin, Jeong-Hoon;Lee, Jae-Gul;Nam, Su-Chul;Choy, Young-Do;Kim, Tae-Kyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.191-200
    • /
    • 2009
  • This paper, which consists of two parts, dealt with the parameter tuning of the power system stabilizer for a 612[MVA] thermal power plant in KEPCO system and its validation in field test. In Part 1 of the paper, the selection of parameters such as lead-lag time constants for phase compensation, system gain was optimized by using linear & eigenvalue analyses and they were verified through the time-domain transient stability analysis. In part 2, the performance of PSS was finally verified by the generator's on-line field test. Through the comparisons of simulation results and measured data before and after tuning of the PSS, the models of generator and its controllers including AVR, Governor and PSS used in the simulation are validated and confirmed.

Effects of HTS Cable Applied to the Voltage Stability Limited Power System (전압 안정도 제약계통에 대한 고온초전도 케이블 적용효과)

  • Lee, Geun-Joon;Hwang, Si-Dol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.169-173
    • /
    • 2004
  • This paper presents the basic application idea of superconductor cable for voltage stability limited power system. In bulk power system, the transfer capability of transmission line is often limited by the voltage stability, and superconductor cable could be one of the countermeasure to enhance heat transfer limit as well as voltage stability limit. Steady state voltage stability approach by P-V curve is used to calculate the maximum transfer capability of initial system and superconductor applied system. IEEE-14 bus system is used to demonstrate its applicability.

Research about movement character of PV Inverter by distribution line impedance (선로임피던스에 의한 태양광 인버터의 동작특성에 관한 연구)

  • Jeong, Jum-Soo;Yoon, Ki-Kab
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.305-309
    • /
    • 2009
  • This paper operate with variable line impedance equipment consist of resister and reactor, when connect to 3phase induce motor present solve problem appear grid interconnection before/after about voltage transient of pv inverter through test and analysis solve problem.

  • PDF

Active and Reactive Power Control of the Battery Energy Storage System interconnected with Power Distribution System (배전계통에 연계된 전지전력저장시스템의 유.무효전력 제어)

  • 김재철;문선호;최준호;김응상
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.127-133
    • /
    • 1999
  • Ths paper deals with the active and reactive power control of Battery Energy Storage System (BESS) during its interconnection operation to power distribution system When an interconnection operation of BESS to power distribution system, it is well suited for peak load shaving and distribution voltage compensation by controlling the real and reactive power. Equivalent mxiel of the distribution system and the BESS is derived and power flow equations are presented to control the real and reactive power of BESS. In this paper, to control the active and reactive power of BESS, $P-\delta$ and Q-V control method and ntJIrerical description is presented. To verify the proposed control method, using PSCAD/EMTDC program simulates the active and reactive power control of BESS.f BESS.

  • PDF

Current Limiting Characteristics due to Location of Superconducting Fault Current Limiter in Power Distribution System (모의 배전계통에 초전도한류기 도입위치에 따른 전류제한 특성)

  • You, Il-Kyoung;Kim, Jin-Seok;Kim, Myoung-Hoo;Lim, Sung-Hun;Moon, Jong-Fil;Kim, Jae-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.97-100
    • /
    • 2009
  • 배전계통에서 전력수요의 증가와 분산전원의 증가로 대용량 변압기의 적용이 불가피하게 되었다. 하지만, 대용량 변압기로 교체할 경우 배전계통에 고장발생시 고장전류의 크기가 증가되어 기존에 설치된 차단기 및 보호기기의 차단용량 초과로 인해 교체에 따른 경제적 비용 상승이 우려된다. 따라서, 대용량 변압기의 교체시 고장전류 증가 문제를 해결하기 위한 방안 중 하나로 초전도한류기를 설치하는 방안을 검토하고 있다. 초전도 한류기는 평상시에 초전도 상태인 영 저항이므로 전력손실이 발생하지 않으며, 고장 발생시 치로 인한 신속한 저항 발생으로 고장전류를 빠르게 감지 및 제한함으로써 기존에 설치된 차단기의 차단 용량이하로 감소시켜 줄뿐만 아니라 계통의 안정도를 향상시킬 수 있다. 그러나, 초전도한류기는 도입위치에 따라 ��치 발생시 초전도한류기의 저항 크기가 다르게 되며, 고장전류 제한효과 및 보호협조를 고려한 적정의 한류기 저항 설정이 필요하다. 이에 대한 선행연구로서, 본 논문에서는 모의 배전계통에 초전도한류기를 적용하였을 경우 도입위치에 따라 전류제한, 모선 전압강하, 초전도한류기의 전력부담을 실험을 통하여 비교 분석하였다. 분석을 통해 초전도한류기를 피더에 설치하였을 경우 전류제한 효과, 모선 전압강하 보상효과는 가장 우수하였으나 가장 많은 전력부담을 갖는 것을 확인할 수 있었다.

  • PDF

A Study on the Simulation Model of PV Generation System for its Application to Real Power System (계통 연계형 태양광 발전 시스템의 실계통 적용을 위한 시뮬레이션 모델에 관한 연구)

  • Lee, Kye-Byung;Son, Kwang-Myung;Jeon, In-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.70-78
    • /
    • 2008
  • This paper deals with the simulation modeling of PV generation system for its application to utility distribution network PSCAD/EMIDC simulation model is developed for use in studying the effect of the PV generation to the distribution system. Simulation results show that the addition of the PV system improves the voltage profile of the area by decreasing the power flow from the utility substation. Case studies also show that power quality at the load side is also improved via voltage compensation at the load bus.

A Study on Long-term Maximum power Demand Forescasting Using Exponential Smoothing (지수평활에 의한 장기 최대전력 수요 예측에 관한 연구)

  • 고희석;이태기
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.3
    • /
    • pp.43-49
    • /
    • 1992
  • Forecasting of electric power demand has been a basic element for electric power system operation and system development, and it's accuracy has very strong influence on reliability and economical efficience of power supply. So, in this paper, long―term maximum electric power demand has been forecasted by using the triple exponential smoothing method initiated R.G.Brown. It has been regarded this method as high accuracy and operational convenience. The smoothing function is a liner combination of all past observations and the weight given to previous observations decreases geometrically with age.

  • PDF

Voltage Compensation Analysis in Distribution System by EMTP (EMTP를 이용한 수변전계통의 전압보상설비효과 분석기법)

  • 설용태;권혁일
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.5
    • /
    • pp.101-107
    • /
    • 1996
  • This paper proposed the voltage compensation analysis method in distribution system by EMTP. SVC (Static Var Compensator) of the thyristor controlled reactor type is used for compensation system. EMTP(E1ectr-o Magnetic Transient Program) model of SVC is proposed to analysis the voltage improvement characteristics at the high voltage system bus. It is composed with three parts ; rms detector, voltage regulator and gate pulse generator. The control signal of TCR is determined by rms value which was measured in system. As the result of EMTP simulation, all of the SVC characteristics like TCR current, firing pulse and bus voltage is very reliable. This method could be used to analysis the planning and the operation of compensation system in the large scale factory.

  • PDF

Analysis of Transient Characteristic in the Railway High Voltage Distribution Lines Using PSCAD/EMTDC at Method of Protection for One Line Ground Fault (PSCAD/EMTDC를 이용한 철도 고압 배전계통의 과도특성 해석 및 1선 지락사고에 대한 보호방안)

  • Park, Kye-In;Chang, Sang-Hoon;Choi, Chang-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.51-56
    • /
    • 2008
  • High quality power supplying of high voltage distribution lines electric railway system is the important function, high voltage distribution system is complicated witch is compose with distribution line, circuit break, protection facilities and so on. Among this components, role of substation is most important for elevation of reliability in electric power system. Therefore, the enhanced reliability considering the preventive inspection, repair work replacement is necessary. This paper proposes protection method in railway high voltage distribution lines. we model distribution system using PSCAD/EMTDC(Power System Computer Aided Design/Electro Magnetic Transients DC Analysis Program) and extract various fault data. In conclusion this methods can protection of ground fault.

A Stduy on Model Development of Boiler Combustion System on Coal Fired Power Plant (석탄화력발전소 보일러 연소계통의 모델개발에 관한 연구)

  • Moon, Chae-Joo;Kim, Yong-Gu;Chung, Hwan-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.65-73
    • /
    • 2004
  • The bolier systems of coal fired power plants are large, non-linear systems with numerous interactions between its component parts. In the analysis of such complex systems, dynamic simulation is recognized as a powerful method of keeping track of the myriad of interactions. The boiler system consists of air/gas system and water/steam system. Due to recent reinforcement of environmental regulation on pollutant discharge and requirements of design validation on properites of boiler, the commercial programs are used for the analysis of boiler system. This paper addressed to the development of model using MMS(Modular Modeling System) developed by EPRI(Electric Power Research Institute) as the simulation tool. The developed model using MMS is tested for the design and local data on boiler combustion system of korea standard coal fired power plant boiler. The simulation results show that the developed model well reproduces responses of the combustion system with less than ${\pm}$5% error under steady state and transient state conditions. The developed model for analysis of the combustion system in this paper is general and applicable to any type of coal fired power plant.