• 제목/요약/키워드: 조명계통

검색결과 460건 처리시간 0.018초

계통연계 인버터의 인덕터 최적화 기법을 통한 LCL 필터 설계 (Design of LCL Filter through Inductor Optimization Method in Grid-Connected Inverter)

  • 장재하;김경화
    • 조명전기설비학회논문지
    • /
    • 제28권11호
    • /
    • pp.58-67
    • /
    • 2014
  • A grid-connected inverter used for renewable energy resources produces harmonic components in the switching frequency. To effectively reduce switching harmonic components, several types of filter are generally used in the output stage of the grid-connected inverter. Many research works on LCL filter design have been done to maintain the performance with low cost. However, it is not easy to make the filter design be economical and optimal due to the varying characteristic of magnetic core and redundancy design by experience. In this paper, a design method for a LCL filter is presented through the inductor optimization scheme in view of the size and cost when the inductor is manufactured using the magnetic core. The effectiveness is verified through tests using a 3kW grid-connected inverter by simulations and experiments.

가공(架空)전력선을 모의(模擬)한 공기 갭에서 교류 및 직류 섬락특성에 미치는 연소화염의 영향 (The Influence of Combustion Flame on AC and DC Flashover Characteristics in the Air-Gaps Simulated Overhead Power Lines)

  • 김인식
    • 조명전기설비학회논문지
    • /
    • 제24권5호
    • /
    • pp.152-159
    • /
    • 2010
  • 가공전력선이 통과하는 지역에서 발생된 연소화염은 계통 섬락사고의 원인이 되고 있다. 본 논문에서는 연소화염에 의한 전력선의 절연내력 저하특성과 화염의 형상변화를 알아보기 위해, 직류 및 교류 전압 인가시 전력선을 모의한 대기압 공기 갭에 대한 섬락특성과 화염의 소화특성을 조사하였다. 실험 결과, 화염에 의한 섬락현상은 비교적 작은 갭에서 발생되었으며, 수평배치형 침대침 갭에서 교류 섬락전압의 상대값은 평균 37.3[%]인 것으로 나타나 화염이 없는 경우에 비해 크게 저하하였다. 갭 길이가 증가함에 따라 전극간 섬락이 발생되기 전에 침전극로부터 발생된 코로나풍에 의해 화염은 소화되는 현상이 나타났다.

IEC 61850 기반의 IED 통합 엔지니어링 툴 개발 (Development of IEC 61850 based Integration Engineering Tool for Intelligent Electronic Device)

  • 한정열;안용호;장병태;송인준;김용학
    • 조명전기설비학회논문지
    • /
    • 제24권8호
    • /
    • pp.101-108
    • /
    • 2010
  • IEC 61850 기반의 변전소자동화 시스템을 구축하기 위해서는 실계통 변전소에서 엔지니어링이 가능한 IED 공통의 엔지니어링 툴 개발이 요구된다. 따라서 본 연구에서는 해외 선진사가 지원하는 시스템 및 SCL 구성 툴과 같이 IED 상호간의 통신분석 및 운영관리에 요구되는 IED 통합 엔지니어링 툴을 개발하고자 한다. 본 연구에서 개발된 IED 통합 엔지니어링 툴은 IEC 61850에서 규정하는 XML 기반의 언어로 작성된 ICD, SCL 및CID 파일을 생성, 편집 및 저장할 수 있는 프로그램이다. 특히 IEC 61850 기반으로 국내에서 개발된 IED에 대한 엔지니어링 작업 등 모든 IED에 적용이 가능한 범용적인 툴로써, IED에 대한 신뢰성 검증과 사용자 중심의 편리함과 효율성을 제공할 수 있다는 장점을 갖고 있다.

변전소 상태변수 추정에 관한 연구 (A Study on the State Estimation for Distribution Substations)

  • 이흥재;박성민;이경섭
    • 조명전기설비학회논문지
    • /
    • 제17권3호
    • /
    • pp.103-109
    • /
    • 2003
  • 전력계통의 자동화에 있어 측정되는 데이터의 정확성은 기본적으로 확립되어야 할 요건이다. 측정된 데이터는 통신 장애나 기기 자체의 오동작으로 인해 오차를 포함할 수 있으며, 이러한 오차는 상태추정에 의해 줄어들 수 있으나, 잘못 측정된 일부 값에 의해 상태추정의 전반적인 신뢰도가 저하될 수 있다. 본 논문에서는 가중최소 상태추정과 카이스퀘어 이론에 근거한 잘못 측정된 데이터의 검출 알고리즘이 제안되었으며, 이를 국내 154kV 변전소에 적용하였다. C 언어와 비쥬얼 베이직을 사용하여 GUI 환경의 시뮬레이터를 개발하였으며, 다른 운용 시스템과의 연계를 고려하여 TCP/IP 프로토콜을 탑재하였다.

지식공학에 의한 전선 착설 예측 및 대책 결정 기법 (Knowledge Engineering Method Ie Estimation of Snow Accretion on Power lines and Decision of Deicing Countermeasures)

  • 최규형
    • 조명전기설비학회논문지
    • /
    • 제17권3호
    • /
    • pp.95-102
    • /
    • 2003
  • 전선착설로 인한 전력설비에의 피해를 방지하기 위하여, 전선착설을 예측하고 적절한 전선착설 방지대책을 제시하는 것은, 전선착설로 인한 피해 발생의 가능성과 전력계통의 안정적 운영의 양 측면을 동시에 고려하여야 하기 때문에 고도한 판단과 결단이 필요한 문제로써, 지식공학적 수법을 적용하는 것이 매우 효과적인 분야이다. 이에 따라, 전선착설의 예측과 방지대책 수립에 관련된 경험적 지식을 지식베이스화하여 전문가 시스템을 구축하고, 사례 데이터를 이용한 시뮬레이션을 통하여 제안 기법의 유효성을 확인하였다.

현장시험에 의한 중성선 고조파 전류 측정, 모델링 및 수동필터 적용에 관한 연구 (A Study on the Measurements, Moldeling, and Passive Filter Application of Neutral Hormonic Currents by Field Tests)

  • 김경철;강윤모;이일무
    • 조명전기설비학회논문지
    • /
    • 제17권1호
    • /
    • pp.103-111
    • /
    • 2003
  • 교육용 건물에는 개인용 컴퓨터와 같은 비선형 부하가 증가하여, 중성선에는 많은 고조파 전류가 흐른다. 3상 4선식 배전 계통을 채용하는 중성선에 과다한 고조파 전류가 흐르면 중성선 도체 과열과 보호 시스템의 오동작등 많은 고조파 장해를 일으킨다. 본 논문에서는 현장에서 실측한 고조파 전류와 전압으로 고조파 해석용 3상 등가회로를 구성하였다. 실측한 값과 MATLAB으로 시뮬레이션한 값을 수치와 그래프로 비교 검토 하였다. 또한 중성선 고조파 전류 저감 대책으로 동조 수동 필터를 사례연구 시스템에 적용하여 고조파 저감 효과도 알아 보았다.

농형 유도발전기의 계통 연계시 전압 변동 및 전력 흐름 분석 (Analysis for Voltage Fluctuation and Power Flow at the Grid-Connected Time of Squirrel-Cage Induction Generator)

  • 김종겸
    • 조명전기설비학회논문지
    • /
    • 제28권6호
    • /
    • pp.45-51
    • /
    • 2014
  • Synchronous generators and induction generators are mainly used in hydroelectric power generation. Synchronous generator is mainly applied to large hydroelectric plants but induction generator is applied to the small hydro power plants. Stability of induction generator is slightly less than the synchronous generator. However, induction generator has many advantages rather than a synchronous generator in terms of price and maintenance. So Induction generator is used primarily in small hydroelectric power station less than 1,000kW recently. Squirrel cage induction generator generates a high inrush current at the grid-connection. This high inrush current causes a voltage drop on the grid. In order to reduce the voltage drop and to analyze the power flow, the analysis for operating characteristics of the induction generator should be reviewed in advance. In this study, we analyzed the voltage drop and power flow analysis when a 1500kW induction generator is connected to the grid. The voltage drop is slightly higher than the acceptable range of distributed power supply voltage and the power flow of the generator is performed well.

고속열차 부하의 고조파 및 플리커 측정에 관한 연구 (A Study on the Harmonics and Flickers Measurement of High Speed Electric Train Loads)

  • 김경철;김유준
    • 조명전기설비학회논문지
    • /
    • 제21권2호
    • /
    • pp.71-77
    • /
    • 2007
  • 고속열차는 전력계통에 전압 변통을 일으키며 시간에 따라 변하는 비선형 부하이다. 시간에 따라 변하는 부하를 해결하기 위해 쓰이는 가장 보편적인 방법은 누적확률을 사용하는 것이다. 플리커는 전압 변동의 크기에 따라 램프의 방출 변화에 의한 인간의 지각 효과로 정의된다. 본 논문에서는 고속열차 부하의 고조파 및 플리커 측정을 심도있게 분석한다. 그리고 측정 결과는 국제 기준인 IEC 61000-3-6과 IEC 61000-3-7에 의해 평가하고자 한다.

열적용량과 전압안정도를 고려한 ATC 계산 방법에 관한 연구 (The ATC Calculation Method with Thermal Constraints and Voltage Stability Constraints)

  • 김재현
    • 조명전기설비학회논문지
    • /
    • 제21권2호
    • /
    • pp.86-93
    • /
    • 2007
  • 본 논문은 가용송전용량(ATC)를 계산하기 위한 두 가지 빠른 계산 기법을 제안한다. 이 방법들은 선로의 열적용량한계(Thermal ATC)와 전압 안정도한계(Voltage ATC)를 제약조건으로 ATC를 계산한다. 먼저 선로의 열적용량을 고려한 방법에서는 모선의 전력 변화에 대한 선로의 조류 감도인 PTDF와 n-1 상정사고를 고려한 LODF를 이용하였으며, 전압안정도를 고려한 방법에서는 2모선 등가 시스템을 이용하여 최대 전력을 구하는 방법을 이용하였다. 제안된 방법은 IEEE 30모선 계통에 적용하였으며 그 결과를 다른 방법과 비교하여 제안된 방법의 타당성을 입증하였다.

TN-C-S계통에서 PEN도체 단선이 인체안전에 미치는 영향 (Personnel Safety Related to Disconnection of PEN Conductor in TN-C-S System)

  • 김정철;이규선;이복희
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.58-64
    • /
    • 2012
  • In electric power supply systems, an earthing system determines the electric potential of the conductors related to that of the Earth's surface. The choice of earthing system has implications for the safety of the power supply systems. There are considerably different regulations for earthing (grounding) systems in each country. A protective earth(PE) conductor ensures that all exposed conductive surfaces are at the same electric potential as the earth surface. This paper deals with that when PEN conductor of TN-C-S system is disconnected, dangerous touch voltage causes personnel body to be harmed and human being's property to be damaged seriously. For this reason, this paper explains how serious problems can occur when the fault current flows. As a consequence, we can understand how we can design earthing system properly to ensure the personnel safety against earth faults. The result shows the way that TN-C-S system can be applied safely in Korea.