• Title/Summary/Keyword: 제체 보강재

Search Result 13, Processing Time 0.02 seconds

Assessment of Ground Improvement Achieved using the Cement Grouting by Vibration Method (CGVM 공법을 이용한 지반개량 효과 검증)

  • Kim, Jong-Tae;Choi, Young-Jun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.26 no.4
    • /
    • pp.497-503
    • /
    • 2016
  • The cement grouting by vibration method (CGVM), a new construction technology developed in Korea, aims to efficiently reinforce a target ground area by injecting vibrated grout into it. The present study applies the CGVM to test sites and verifies its effect. Standard penetration tests (SPTs), field permeability tests, and geophysical surveys were conducted in two study areas, and the results were compared between before and after CGVM application. The SPT conducted before and after the CGVM application showed that the N value was increased by 33.57% point to 60.90% point. The field permeability test showed that the permeability coefficient decreased. These results indicate that CGVM may increase imperviousness and improve reservoir system stability. In addition, a resistivity survey found no low-resistivity zone, unlike before the CGVM application, thereby indicating the excellent grouting effect of the CGVM.

Properties of Grout Material for Seawall Using Slags from Steel Making Industry (철강산업부산물을 사용한 방조제용 그라우트 재료 및 그 특성)

  • Ha-Seog, Kim;Kee-Seok, Kim;Bong-Hyun, Baek;Sim-Hoon, Yook
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.4
    • /
    • pp.523-530
    • /
    • 2022
  • The problem in the construction of seawall reinforcing the seawall where there is seawater flow is the outflow of materials. Gravity-type pouring of concrete is difficult to fill the voids smoothly, and the cement of concrete that has not hardened is likely to be dispersed in seawater. This phenomenon not only reduces the reliability of quality after concrete hardening, but can also adversely affect the surrounding environment. Therefore, there is a need for a gel-like injection material that can be injected, In this study, the initial strength and durability improvement effect of seawater immersion were evaluated by using electrofurnace reduction slag and blast furnace slag with acute properties. As a result of the experiment, it was possible to prepare a gel-like injection material having flowability through reaction with silica-based chemical liquid. The flowability of the gel is 105~143 mm depending on the formulation, and the on-site simulation test can fill the voids without external leakage, confirming its on-site applicability.

Potential Hazard Classification of Aged Cored Fill Dams (노후 코어형 필댐의 잠재 위해성 유형 분류)

  • Park, DongSoon;Oh, Je-Heon
    • The Journal of Engineering Geology
    • /
    • v.26 no.2
    • /
    • pp.207-221
    • /
    • 2016
  • As greater numbers of fill dams and reservoirs become old, the risks of damage or embankment collapse increases. However, few studies have considered the deterioration and hazard classification of the internal core layers of fill dams. This study reports the results of geotechnical investigations of 13 earth-cored fill dams in Korea, based on no-water borehole drilling, Standard Penetration Test, and 2D and 3D electrical resistivity surveys along with in situ and laboratory testing. High-capacity no-water boring minimized core layer disturbance while providing continuous core sample recovery. The results allow the classification of potential hazards related to the existing core layers based on both visual inspection of the recovered samples and the results of engineering surveys and tests. Four types of potential hazard are classified: locally fluidized core with a high water content, rapid water inflow to a borehole, cores with granular materials, and relatively low stiffness of core. Among these, the locally fluidized core is the most critical hazard that requires remedial action because it is related to the potential internal flow path and internal erosion. The other three hazard types are of medium importance and require careful monitoring and regular inspection. Of note, there was no correlation between age and core deterioration. The results are expected to aid the safe management and potential upgrading of aging cored fill dams.