• Title/Summary/Keyword: 제어 및 감시장치

Search Result 170, Processing Time 0.028 seconds

Study on WAMAC System Architecture Design, Including PMU Data Verification System (PMU Data 검증시스템을 포함한 WAMAC 시스템 설계에 관한 연구)

  • Cho, Jun-Hee;Choi, Mi-Hwa;Lee, Myeong-Woo;Kim, Sang-Tae;Woo, Doug-Je
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.1 no.3
    • /
    • pp.181-186
    • /
    • 2012
  • PMU based power grid monitoring and control system, WAMAC (Wide Area Monitoring And Control) system is required system design for accurate power data without error and loss through a system-wide. In the paper, we propose system design that measured data from PMU transmitted without loss to PDC and DSM server. and we propose a method to verify the real-time "data has been transmitted accurately". Verification system has been designed to reflect the WAMAC system. Therefore the WAMAC can enhance the reliability of the analysis of the data, and it can monitor lossless real-time trend data.

Development of Intelligent Outlets for Real-Time Small Power Monitoring and Remote Control (실시간 소전력 감시 및 원격제어용 지능형 콘센트 개발)

  • Kyung-Jin Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.2
    • /
    • pp.169-174
    • /
    • 2023
  • Currently, overall power usage is also increasing as power demand such as homes, offices, and factories increases. The increase in power use also raised interest in standby power as a change in awareness of energy saving appeared. Home and office devices are consuming power even in standby conditions. Accordingly, there is a growing need to reduce standby power, and it aims to have standby power of 1W or less. An intelligent outlet uses a near-field wireless network to connect to a home network and cut or reduce standby power of a lamp or appliance connected to an outlet. This research aims to develop a monitoring system and an intelligent outlet that can remotely monitor the amount of electricity used in a lighting lamp or a home appliance connected to an outlet using a short-range wireless network (Zigbee). Also, The intelligent outlet and monitoring system developed makes it possible for a user to easily cut off standby power by using a portable device. Intelligent outlets will not only reduce standby power but also be applicable to fire prevention systems. Devices that cut off standby power include intelligent outlets and standby power cutoff switches, so they will prevent short circuits and fires.

Reliability improvement in distribution network operation by applying Off-line type DAS calculation Program (배전자동화기반 오프라인 기술계산 프로그램도입으로 계통운영 신뢰도 제고)

  • Kim, Ju-Seong;Yi, Seu-Muk;Seo, Dong-Kwen
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.142-144
    • /
    • 2008
  • 한국전력공사(이하 한전)에서는 배전계통의 최적운영을 위하여 계통운영에 필요한 기술을 발굴하여 축적하는데 많은 노력을 기울여 왔으며, 계통운영의 핵심 툴인 배전자동화 시스템을 통하여 관련기술을 축적해오고 있다. 우리나라처럼 배전자동화 시스템을 전력회사에서 자체적으로 개발하여 활용하는 사례는 전 세계적으로 유일하며, 이를 기반으로 해외 전력시장에 배전자동화 시스템을 수출하기 위하여 활발한 활동을 지속적으로 추진되고 있다. 배전자동화 시스템을 이용하면 원격으로 현장에 있는 배전자동화기기를 감시, 제어, 조작, 정정이 가능한 기본기능이 구현가능하고, 각종 계통운영에 필요한 기술계산, 즉 전압강하계산, 보호협조검토, 표준조작지시서(SOP)의 생성, 상시개방점 위치조정으로 손실최소화, 분산전원 연계계통 기술검토의 자동처리가 가능해진다. 기술계산프로그램은 최초 개발 당시인 2002년에는 배전자동화시스템 주장치가 설치된 장소인 온라인 상태에서만 사용이 가능하여 사용상 제약을 가지고 있었으나, 이를 개선하고자 2006년 10월 배전자동화기반 오프라인형 기술계산프로그램을 개발하였고 이를 지속적으로 업그레이드를 추진하여 활용해오고 있다. 배전자동화기반 오프라인형 기술계산프로그램은 배전자동화주장치에서 데이터를 추출하여 배전자동화주장치가 아닌 일반PC나 노트북에서도 배전자동화시스템에 내장된 배전계통 정보 즉, 선로길이 및 전력선 제원 등을 직접 이용하므로 각종 기술계산을 신속하고 정확하게 수행하는 것이 가능하게 되었다. 따라서 이를 지속적으로 활용하고 성능개선을 추진하여 배전계통 운영시 신뢰도 제고에 크게 기여할 것으로 기대되고 있다.

  • PDF

Intrusion Detection Methodology for SCADA system environment based on traffic self-similarity property (트래픽 자기 유사성(Self-similarity)에 기반한 SCADA 시스템 환경에서의 침입탐지방법론)

  • Koh, Pauline;Choi, Hwa-Jae;Kim, Se-Ryoung;Kwon, Hyuk-Min;Kim, Huy-Kang
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.22 no.2
    • /
    • pp.267-281
    • /
    • 2012
  • SCADA system is a computer system that monitors and controls the national infrastructure or industrial process including transportation facilities, water treatment and distribution, electrical power transmission and distribution, and gas pipelines. The SCADA system has been operated in a closed network, but it changes to open network as information and communication technology is developed rapidly. As the way of connecting with outside user extends, the possibility of exploitation of vulnerability of SCADA system gets high. The methodology to protect the possible huge damage caused by malicious user should be developed. In this paper, we proposed anomaly detection based intrusion detection methodology by estimating self-similarity of SCADA system.

A Study on Energy Savings of a DC-based Variable Speed Power Generation System (직류기반 가변속 발전 시스템을 이용한 에너지 절감에 관한 연구)

  • Kido Park;Gilltae Roh;Kyunghwa Kim;Changjae Moon;Jongsu Kim
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.6
    • /
    • pp.666-671
    • /
    • 2023
  • As international environmental regulations on ship emissions are gradually strengthened, interest in electric propulsion and hybrid propulsion ships is increasing, and various solutions are being developed and applied to these ships, especially stabilization of the power system and system efficiency. The direct current distribution system is being applied as a way to increase the power. In addition, verification and testing of safety and performance of marine DC distribution systems is required. As a result of establishing a DC distribution test bed, verifying the performance of the DC distribution (variable speed power generation) system, and analyzing fuel consumption, this study applied a variable speed power generation system that is applied to DC power distribution for ships, and converted the power output from the generator into a rectifier. A system was developed to convert direct current power to connect to the system and monitor and control these devices. Through tests using this DC distribution system, the maximum voltage was 751.5V and the minimum voltage was 731.4V, and the voltage fluctuation rate was 2.7%, confirming that the voltage is stably supplied within 3%, and a variable speed power generation system was installed according to load fluctuations. When applied, it was confirmed through testing that fuel consumption could be reduced by more than 20% depending on the section compared to the existing constant speed power generation system.

Memory-Free Skin-Detection Algorithm and Implementation of Hardware Design for Small-Sized Display Device (소형 DISPLAY 장치를 위한 비 메모리 피부 검출 알고리즘 및 HARDWARE 구현)

  • Im, Jeong-Uk;Song, Jin-Gun;Ha, Joo-Young;Kang, Bong-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.8
    • /
    • pp.1456-1464
    • /
    • 2007
  • The research of skin-tone detection has been conducting continuously to enlarge the importance in security, surveillance and administration of the information and 'Password Control System' for using face and skin recognition in airports, harbors and general companies. As well as tile rapid diffusion of the application range in image communications and an electron transaction using wide range of communication network, the importance of the accurate detection of skin color has been augmenting recently. In this paper, it will set up the boundaries of skin colors using the information of Cb and Cr in YCbCr color model of human skin color which is from hundreds compiled portrait images for each race, and suggest a efficient yet simple structure about the skin detection which has been followed by whether the comprehension of the boundaries of skin or not with adaptive skin-range set. With the possibility of the 1D Processes which does not use any memory, it is able to be applied to relatively small-sized hardware and system such as mobile apparatuses. To add the selective mode, it is not only available the improvement of tie skin detection, but also showing the correspondent results about previous face recognition technologies using complicated algorithm.

Self-Organizing Middleware Platform Based on Overlay Network for Real-Time Transmission of Mobile Patients Vital Signal Stream (이동 환자 생체신호의 실시간 전달을 위한 오버레이 네트워크 기반 자율군집형 미들웨어 플랫폼)

  • Kang, Ho-Young;Jeong, Seol-Young;Ahn, Cheol-Soo;Park, Yu-Jin;Kang, Soon-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.7
    • /
    • pp.630-642
    • /
    • 2013
  • To transmit vital signal stream of mobile patients remotely, it requires mobility of patient and watcher, sensing function of patient's abnormal symptom and self-organizing service binding of related computing resources. In the existing relative researches, the vital signal stream is transmitted as a centralized approach which exposure the single point of failure itself and incur data traffic to central server although it is localized service. Self-organizing middleware platform based on heterogenous overlay network is a middleware platform which can transmit real-time data from sensor device(including vital signal measure devices) to Smartphone, TV, PC and external system through overlay network applied self-organizing mechanism. It can transmit and save vital signal stream from sensor device autonomically without arbitration of management server and several receiving devices can simultaneously receive and display through interaction of nodes in real-time.

Effect Analysis of Classical Line TI-21 type Audio Frequency Track Circuit from KTX Sancheon Return Current Harmonics (KTX산천 귀선전류고조파가 일반선 TI-21형 AF궤도회로에 미치는 영향분석)

  • Choi, Jae Sik;Kim, Hie Sik;Park, Ju Hun;Kim, Bun Gon
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.1
    • /
    • pp.38-45
    • /
    • 2016
  • The power transformation system of High Speed rolling stocks like KTX-Sancheon has shown excellent control capacities in the areas of riding comfortability, switching efficiency, safety and energy consumption due to technical developments in power-electronics, high speed & large scale integrated semiconductors and microprocessors. However, harmonics from IGBT, a high speed switching device used in the Convertor & Invertor equipment of rolling stocks have given rise to various problems in transformer substations, signaling systems, data transmission systems and facility monitoring systems. Especially, TI21 non-insulated track circuits have malfunctioned due to the influence of returning current harmonics which were generated at around of integer times of the number of power transformation equipment in the frequency domain. This paper, measures and analyzes various schemes to analyze the traveling path of the returning current harmonics generated due to the relationship between the rolling stocks and track circuits on site. Ultimately, theseschemes will be used to design high speed rolling stocks, AF track circuits and a common grounding network.

Long-term Climate Change Research Facility for Trees: CO2-Enriched Open Top Chamber System (수목의 장기 기후변화 연구시설: CO2 폭로용 상부 개방형 온실)

  • Lee, Jae-Cheon;Kim, Du-Hyun;Kim, Gil-Nam;Kim, Pan-Gi;Han, Sim-Hee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.14 no.1
    • /
    • pp.19-27
    • /
    • 2012
  • The open-top chamber (OTC) system is designed for long term studies on the climate change impact on the major tree species and their community in Korea. In Korea Forest Research Institute (KFRI), the modified OTC system has been operating since September 2009. The OTC facility consists of six decagon chambers (10 meters in diameter by 7 meters high) with controlled gas concentration. In each chamber, a series of vertical vent pipes are installed to disperse carbon dioxide or normal air into the center of the chamber. The OTC is equipped with remote controlled computer system in order to maintain a stable and elevated concentration of carbon dioxide in the chamber throughout the experimental period. The experiment consisted of 4 treatments: two elevated $CO_2$ levels ($1.4{\times}$ and $1.8{\times}$ ambient $CO_2$) and two controls (inside and outdoors of the OTC). Average operational rate was the lowest (94.2%) in June 2010 but increased to 98% in July 2010 and was 100% during January to December 2011. In 2010~2011, $CO_2$ concentrations inside the OTCs reached the target programmed values, and have been maintained stable in 2011. In 2011, $CO_2$ concentrations of 106%, 100% and 94% of target values has been recorded in control OTC, $1.4{\times}$ $CO_2$-enriched OTC and $1.8{\times}$ $CO_2$-enriched OTC, respectively. With all OTC chambers, the difference between outside and inside temperatures was the highest ($1.2{\sim}2.0^{\circ}C$) at 10 am to 2 pm. Temperature difference between six OTC chambers was not detected. The relative humidity inside and outside the chambers was the same, with minor variations (0~1%). The system required the highest amount of $CO_2$ for operation in June, and consumed 11.33 and 17.04 ton in June 2010 and 2011, respectively.

A Case Study on the Effective Liquid Manure Treatment System in Pig Farms (양돈농가의 돈분뇨 액비화 처리 우수사례 실태조사)

  • Kim, Soo-Ryang;Jeon, Sang-Joon;Hong, In-Gi;Kim, Dong-Kyun;Lee, Myung-Gyu
    • Journal of Animal Environmental Science
    • /
    • v.18 no.2
    • /
    • pp.99-110
    • /
    • 2012
  • The purpose of the study is to collect basis data for to establish standard administrative processes of liquid fertilizer treatment. From this survey we could make out the key point of each step through a case of effective liquid manure treatment system in pig house. It is divided into six step; 1. piggery slurry management step, 2. Solid-liquid separation step, 3. liquid fertilizer treatment (aeration) step, 4. liquid fertilizer treatment (microorganism, recirculation and internal return) step, 5. liquid fertilizer treatment (completion) step, 6. land application step. From now on, standardization process of liquid manure treatment technologies need to be develop based on the six steps process.