• Title/Summary/Keyword: 제거회전력

Search Result 59, Processing Time 0.031 seconds

A Study on Titanium Miniscrew as Orthodontic Anchorage : An experimental investigation in dogs (성견에서 교정적 고정원으로서의 티타늄 미니스크류에 대한 연구)

  • Yoon, Byung-Soo;Choi, Byung-Ho;Lee, Won-You;Kim, Kyoung-Nam;Shim, Hyung-Bo;Park, Jin-Hyung
    • The korean journal of orthodontics
    • /
    • v.31 no.5 s.88
    • /
    • pp.517-523
    • /
    • 2001
  • Titanium miniscrews we being used increasingly as an anchorage for tooth movement, because they ate easy to place and to remove, increase the number of sites available, give minimum strain to patients regarding surgical procedures, and offer uneventful healing alter removal. The use of titanium miniscrews as an orthodontic anchorage has been reported in clinical case reports, but clinicians have experienced screw loosening when using such screws.' To our knowledge, there are no published reports evaluating the stability of miniscrews. Information about the length of miniscrews used in relation to the location is of some importance, as stability will vary depending on bone duality The purpose of this study was to evaluate a variety of Lengths of miniscrews (dimeter: 2mm) which were inserted in maxilla or mandible and to demonstrate in a dog model which miniscrew provides fundamental stability in the jaws. 10 mm long miniscrews in the maxilla and 8mm long: miniscrews in the mandible showed no clinical mobility and retained their position throughout an 8 weeks force (200g) application. The mucosal condition around the screws was healthy in cases in which miniserews were inserted in the alveolar bone between the roots and the head of the screws emerged into the attached gingiva. When the force application was terminated, radiographic analysis revealed neither rent resorption not periodontal pathology around the miniscrews that remained stable during the entire treatment period. This study suggests that if titanium miniscrews with adequate length are properly used depending on the location, they provide sufficient stability for orthodontic anchorage.

  • PDF

Effect of cutting flute length and shape on insertion and removal torque of orthodontic mini-implants (교점용 미니 임플랜트의 cutting flute의 길이 및 형태에 따른 식립 및 제거 토크의 비교)

  • Yun, Soon-Dong;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.39 no.2
    • /
    • pp.95-104
    • /
    • 2009
  • Objective: The purpose of this study was to evaluate the effect of length and shape of cutting flute on mechanical properties of orthodontic mini-implants. Methods: Three types of mini-implants with different flute patterns (Type A with 2.6 mm long flute, Type B with 3.9 mm long and straight flute, Type C with 3.9 mm long and helical flute) were inserted into the biomechanical test blocks (Sawbones Inc., USA) with 2 mm and 4 mm cortical bone thicknesses to test insertion and removal torque. Results: In 4 mm cortical bone thickness, Type C mini-implants showed highest maximum insertion torque, then Type A and Type B in order. Type C also showed shortest total insertion time and highest maximum removal torque, but Type A and B didn't showed statistically significant difference in insertion time and removal torque. In 2 mm cortical bone thickness, there were no significant difference in total insertion time and maximum removal torque in three types of mini-implants, but maximum insertion torque of Type A was higher than two other Types of mini-implants. Conclusions: Consideration about length and shape of cutting flute of mini-implant is also required when the placement site has thick cortical bone.

Development of a Rotation Swab Pig Method for Cleaning Water Pipes (상수관의 세척을 위한 회전식 스왑피그 공법 개발)

  • Kicheol Lee;Jaeho Kim;Kisung Kim;Jeongjun Park
    • Journal of the Korean Geosynthetics Society
    • /
    • v.23 no.2
    • /
    • pp.63-75
    • /
    • 2024
  • Drinking water is an essential element to ensure the basic human right to live, and the quality of clean water must always be ensured. However, domestic water facilities, which were installed intensively in the early 2000s, are deteriorating. The accidents such as discoloration of water such as chromaticity and turbidity as well as leakage of substances frequently occur. However, since it is virtually impossible to replace all water pipes, the detailed standards for maintenance of water pipe network facilities established in 2021 require water pipe cleaning. The swab pig method, one of the water pipe cleaning methods, is a method of physically removing substances in pipes and is evaluated as having the highest cleaning efficiency. However, Swab is highly likely to be damaged or deformed during the cleaning process, and may even be lost. Therefore, in this study, the material of the pig was changed to a material with high compressibility, and it was made as close as possible to the inner wall of the water pipe. And, to maximize cleaning efficiency, a rotation swab pig with a rotation blade was developed. In addition, high-strength wire and winding equipment were additionally developed to eliminate the possibility of loss and to determine the location of the pig. The inlet and outlet are connected with wires, and after verifying the performance of each detailed technology, the technology was applied on a test bed with a 30m section. As a result of the application, the performance of the technology was verified by measuring the process time and evaluating applicability.

Measuring Intracellular Mycobacterial Killing Using a Human Whole Blood Assay (인체 전혈 모델을 이용한 세포내 결핵균 살균력에 관한 연구)

  • Cheon, Seon-Hee;Song, Ho-Yeon;Lee, Eun-Hee;Oh, Hee-Jung;Kang, In-Sook;Cho, Ji-Yoon;Hong, Young-Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.5
    • /
    • pp.497-509
    • /
    • 2002
  • Background : The mechanisms through which cellular activation results in intracellular mycobacterial killing is only partially understood. However, in vitro studies of human immunity to Mycobacterium tuberculosis have been largely modeled on the work reported by Crowle, which is complicated by several factors. The whole blood culture is simple and allows the simultaneous analysis of the relationship between bacterial killing and the effect of effector cells and humoral factors. In this study, we attempted to determine the extent to which M. tuberculosis is killed in a human whole blood culture and to explore the role of the host and microbial factor in this process. Methods : The PPD positive subject were compared to the umbilical cord blood and patients with tuberculosis, diabetes and lung cancer. The culture is performed using heparinized whole blood diluted with a culture medium and infected with a low number of M. avium or M. tuberculosis $H_{37}Ra$ for 4 days by rotating the culture in a $37^{\circ}C$, 5% $CO_2$ incubator. In some experiments, methlprednisolone- or pentoxifyline were used to inhibit the immune response. To assess the role of the T-cell subsets, CD4+, CD8+ T-cells or both were removed from the blood using magnetic beads. The ${\Delta}$ log killing ratio was defined using a CFU assay as the difference in the log number of viable organisms in the completed culture compared to the inoculum. Results : 1. A trend was noted toward the improved killing of mycobacteria in PPD+ subjects comparing to the umbilical cord blood but there was no specific difference in the patients with tuberculosis, diabetes and lung cancer. 2. Methylprednisolone and pentoxifyline adversely affected the killing in the PPD+ subjects umbilical cord blood and patients with tuberculosis. 3. The deletion of CD4+ or CD8+ T-lymphocytes adversely affected the killing of M. avium and M. tuberculosis $H_{37}Ra$ by PPD+ subjects. Deletion of both cell types had an additive effect, particularly in M. tuberculosis $H_{37}Ra$. 4. A significantly improved mycobacterial killing was noted after chemotherapy in patients with tuberculosis and the ${\Delta}$ logKR continuously decreased in a 3 and 4 days of whole blood culture. Conclusion : The in vitro bactericidal assay by human whole blood culture model was settled using a CFU assay. However, the host immunity to M. tuberculosis was not apparent in the human whole blood culture bactericidal assay, and patients with tuberculosis showed markedly improved bacterial killing after anti-tuberculous chemotherapy compared to before. The simplicity of a whole blood culture facilitates its inclusion in a clinical trial and it may have a potential role as a surrogate marker in a TB vaccine trial.

A Study on the Improvement of Color Detection Performance of Unmanned Salt Collection Vehicles Using an Image Processing Algorithm (이미지 처리 알고리즘을 이용한 무인 천일염 포집장치의 색상 검출 성능 향상에 관한 연구)

  • Kim, Seon-Deok;Ahn, Byong-Won;Park, Kyung-Min
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.6
    • /
    • pp.1054-1062
    • /
    • 2022
  • The population of Korea's solar salt-producing regions is rapidly aging, resulting in a decrease in the number of productive workers. In solar salt production, salt collection is the most labor-intensive operation because existing salt collection vehicles require human operators. Therefore, we intend to develop an unmanned solar salt collection vehicle to reduce manpower requirements. The unmanned solar salt collection vehicle is designed to identify the salt collection status and location in the salt plate via color detection, the color detection performance is a crucial consideration. Therefore, an image processing algorithm was developed to improve color detection performance. The algorithm generates an around-view image by using resizing, rotation, and perspective transformation of the input image, set the RoI to transform only the corresponding area to the HSV color model, and detects the color area through an AND operation. The detected color area was expanded and noise removed using morphological operations, and the area of the detection region was calculated using contour and image moment. The calculated area is compared with the set area to determine the location case of the collection vehicle within the salt plate. The performance was evaluated by comparing the calculated area of the final detected color to which the algorithm was applied and the area of the detected color in each step of the algorithm. It was confirmed that the color detection performance is improved by at least 25-99% for salt detection, at least 44-68% for red color, and an average of 7% for blue and an average of 15% for green. The proposed approach is well-suited to the operation of unmanned solar salt collection vehicles.

Aerodynamic Characteristics of an Insect-type Flapping Wings (곤충 모방 플래핑 날개의 공력 특성)

  • Han, Jong-Seob;Chang, Jo-Won;Choi, Hae-Cheon;Kang, In-Mo;Kim, Sun-Tae
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.311-314
    • /
    • 2007
  • Aerodynamic characteristics of an insect-type flapping wings were carried out to obtain the design parameters of Micro Hovering Air Vehicle. A pair of wing model was scaled up about 200 times and applied two pairs of 4-bar linkage mechanism to mimic the wing motion of a fruit fly(Drosophila). To verify the Weis-Fogh mechanism, a pair of wings revolved on the 'Delayed Rotation'. Lift and drag were measured in conditions of the Reynolds number based on wing tip velocity of about 1,200 and the maximum angle of attack of 40$40^{\circ}$. Inertia forces of a wing model were also measured by using a 99.98% vacuum chamber and subtracted on measured data in air. In the present study, high lift effect of Weis-Fogh mechanism was appeared in the middle of upstroke motion.

  • PDF

Self-Starting Characteristics of Blades for Vertical Axis Wind turbine (수직축 풍력발전용 날개의 기동력특성)

  • Kim, Sung-Hoon;Kim, Young-Ik;Lee, Joon-Min
    • Journal of Energy Engineering
    • /
    • v.29 no.1
    • /
    • pp.34-43
    • /
    • 2020
  • A study has been done for self-starting torque of vertical axis wind turbine blade. It is especially concentrated to evaluate the torque coefficient before starting rotation. Two different aerofoils(AMI903 and AMI904) are proposed to benchmark the possible best blade(supercritical airfoil) for self-starting performance. Torque coefficients in the tangential direction of rotation are given with respect to the angle of attack in terms of drag coefficient and lift coefficient. Torque coefficient shows that the effect of Reynolds number is minimal. The thicker blade(AMI904) between two different proposed airfoils has bigger torque coefficient, which is attributed to lower lift coefficient and higher drag coefficient.

REMOVAL TORQUE AND BONE FORMATION OF ORTHODONTIC MINISCREW IMPLANT (교정용 미니스크류 임플랜트의 제거회전력 및 골형성에 관한 연굴)

  • Yun, Young-Kuk;Ryu, Jae-Jun;Suh, Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.492-505
    • /
    • 2007
  • Statement of problem: An orthodontic miniscrew implant has been used as a skeletal anchorage for orthodontic treatment. However, any relation among the influence of the cortical bone, morphologic differences of orthodontic miniscrew implants and new bone formation hasn't been made clear yet. Purpose: The purpose of this study was to evaluate whether the orthodontic miniscrew implant could work as an intraoral skeletal anchorage immediately and stably for orthodontic treatment after insertion of it. Material and methods: Two types of orthodontic miniscrew implants were used in this experiment; tapered type and straight type. One hundred and sixty eight orthodontic miniscrew implants were inserted into the tibiae of 21 rabbits and sacrificed on 3, 7, 11, 14, 21 and 28days later after insertion of them to study removal torque values and histologic and histomorphometric analyses. Results: The results were as follows. 1. The removal torque values of the tapered type were higher than those of the straight type in all groups(p<0.05). 2. There wasn't any distinguishing differences between the tapered type and the straight type about the new bone formation percentage. 3. The removal torque values for both the tapered type and the straight type were gradually decreased at early stages of the test but started to increase at the 7 days group of the straight type and the 11 days group of the tapered type. 4. New bone formation percentage was increased gradually for both the tapered and the straight types as time passed(p<0.05). 5. It was found that the tapered type showed lower values in the cortical bone about both the maximum equilibratory stress distribution and the maximum principal stress distribution than the straight type in linear finite elements analysis. Conclusion: According to the research, the removal torque values were decreased at 7 days group of the tapered type and 11 days group of the straight type after the insertion of the orthodontic miniscrew implants in tibiae of rabbits. Considering the human bone activity, it is better to apply the orthodontic force $3{\sim}4$ weeks later than to apply it immediately after the insertion of orthodontic miniscrew implants. Considering that general orthodontic force is about $250{\sim}500$ grams, the tapered type can be worked as a stable skeletal anchor age in an orthodontic treatment even if the orthodontic force is applied on it immediately after the insertion of it.

Comparative study of removal torque of 3 different hydroxyapatite coated implants in the femur of rabbits (가토의 대퇴골에 식립한 3종류의 수산화인회석 코팅 임플란트에 대한 제거회전력 비교 연구)

  • Kim, Sang-Soo;Lee, Ju-Hyung;Yu, Seok-Hyun;Lee, Hyung-Ju;Moon, Jee-Won;Park, In-Sook;Sohn, Dong-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.1
    • /
    • pp.49-53
    • /
    • 2011
  • Introduction: This study compared the strength of osseointegration as determined by the resistance to reverse torque rotation of three different hydroxyapatite coated implants in the rabbit femur model. Materials and Methods: Three hydroxyapatite coated implants (HAPTITE), Tapered Screw-Vent (TSV) and BioTite-H - were used. A total of 40 implants were placed in the femur of 20 adult male rabbits. The animals were divided into two groups. In group A (n=10); one HAPTITE was placed into each right femur and one TSV was placed into each left femur. In group B (n=10); one HAPTITE was placed into each right femur and one BioTite-H was placed into each left femur. Five rabbits of each group were sacrificed at 4 and 8 weeks. The implants were removed by reverse torque rotation using a digital torque-measuring device. A total of 40 implants in 20 rabbits were used for the removal torque measurements. Results: In the Group A, 4 weeks after implant placement, the mean removal torque for the HAPTITE and TSV was $70.7{\pm}31.6$ N cm and $28.9{\pm}15.1$ N cm, respectively. Eight weeks after implant placement, the mean removal torque for the HAPTITE and TSV was $87.9{\pm}26.2$ N cm and $54.9{\pm}22.4$ N cm, respectively. In the Group B, 4 weeks after implant placement, the mean removal torque for the HAPTITE and BioTite-H was $58.0{\pm}29.6$ N cm and $37.7{\pm}14.1$ N cm, respectively. Eight weeks after implant placement, the mean removal torque for the HAPTITE and BioTite-H was $91.4{\pm}47.1$ N cm and $30.8{\pm}9.8$ N cm. HAPTITE showed a higher removal torque than the other implants. Conclusion: These results suggest that HAPTITE increases the strength of osseointegration significantly as determined by the resistance to reverse torque rotation.

A Study on the Deposition of Chitosan for Enhancing the Adsorption Ability of Activated Carbon (활성탄의 흡착력 향상을 위한 키토산 첨착에 관한 연구)

  • Ju, Han-Shin;Kim, Byung-Hoon;Jung, Sang-Chul;Ra, Deog-Gwan;Chung, Min-Chul;Ahn, Ho-Geun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.203-210
    • /
    • 2000
  • The preparative methods of a chitosan-deposited activated carbon and its characteristics were studied by using three kinds of chitosan with different degree of deacetylation and average molecular weight. The procedure was consisted of the dissolution of chitosan into acid solution, impregnation of activated carbon, agitation, evaporation, and drying. When the chitosan-dissolved acid and its concentration, amounts of chitosan deposited, and agitation conditions were changed, the specific surface area, deposition state on surface, and stability were investigated, and amounts of Cr(VI) adsorbed was measured. In the preparation process, it was proper to agitate the chitosan-dissolved acetic acid solution at room temperature for 1hr. In the deposition of chitosan with low molecular weight, the specific surface area of activated carbon was greatly decreased even at low chitosan loading, but in the case of high molecular weight it was not nearly changed to 10wt% loading. It was known that chitosan was uniformly and physically deposited on activated carbon. The chitosan-deposited activated carbon was stable into the solution over about pH 6. The removal of Cr(VI) was remarkably enhanced by adding the adsorption function of chitosan to the surface of activated carbon with about 5wt% chitosan. It may be therefore used as an adsorbent for removing the pollutants in air and wastewater.

  • PDF