• Title/Summary/Keyword: 제거수술

Search Result 821, Processing Time 0.023 seconds

Artifacts and Troubleshooting in Intraoperative Neurophysiological Monitoring (수술중신경계감시검사에서 발생하는 인공산물의 종류와 해결 방법)

  • Lim, Sung Hyuk;Kim, Kap Kyu;Jang, Min Hwan;Kim, Ki Eob;Park, Sang-Ku
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.1
    • /
    • pp.122-130
    • /
    • 2021
  • The types of artifacts that are observed in intraoperative neurophysiological monitoring (INM) is truly diverse. The removal of artifacts that interfere with the examination is essential. In addition, improving the quality of the examination by removing artifacts is a reflection of the competency of the examiner and is also the best way to ensure patient safety. However, if knowledge of the equipment or anesthesia in the operating room is insufficient due to lack of experience, artifacts cannot be removed even with a method appropriate to the situation. If artifacts are not separated and removed, the reading of the examination results in confusion in the operation process. This can be a fatal problem in neurosurgery that requires rapid and sophisticated procedures. In this paper, the causes of artifacts that occur during surgery are classified into electrical factors, non-electrical factors, and other factors, and a method and examination method for removing artifacts according to the specific situation is mentioned. Although the operating room environment is a very critical place to simultaneously consider various scenarios, we hope that a stable and optimal INM will play a role by knowing the types and causes of various artifacts and how to tackle them.

Left Ventricular Pseudoaneurysm after Surgery for Infective Endocarditis with Annular Abscess - A case report - (판막륜 농양을 동반한 감염성 심내막염 수술 후 발생한 좌심실 가성류 - 치험 1예 -)

  • 황호영;김기봉
    • Journal of Chest Surgery
    • /
    • v.36 no.4
    • /
    • pp.273-276
    • /
    • 2003
  • We report a surgical case of 39-year-old male with a pseudoaneurysm of the left ventricle. Four years ago, the patient underwent aortic and mitral valve replacements with mechanical valves and abscess removal for infective endocarditis with annular abscess. Recent echocardiography demonstrated a communication between left ventricle and abscess pocket, and the size of pocket increased further at the follow-up echocardiography. The patient underwent patch closure of the defect between left ventricle and pseudoaneurysm located at the aortomitral fibrous continuity, under the cardiopulmonary bypass and cardioplegia. The postoperative course was uneventful and the patient was discharged on the 9th postoperative day.

Results of Arthroscopic-assisted Minimally Invasive Removal of a Lateral Periarticular Plate used for the Treatment of AO Type-C Distal Femoral Fractures (AO C-형 원위 대퇴골 골절의 치료로 삽입된 관외측 금속판의 절경 보조하 최소 침습적 제거의 결과)

  • Kim, Young-Mo;Lee, June-Kyu;Yang, Jae-Hoon;Kim, Bo-Kun;Lee, Won-Gu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Purpose: To evaluate the usefulness of minimally invasive arthroscopy-assisted plate removal of a laterally inserted periarticular distal femur plate used for the treatment of AO type-C distal femur fractures. Materials and Methods: From October 2002 to November 2005, we evaluated 17 patients whose plates were removed through minimally invasive arthroscopy-assisted plate-removal technique and 15 patients who got their plates removed through conventional method without using arthroscopy, 32 patients in total. All these patients included in this study initially underwent open reduction and internal fixation of the distal femoral fractures with a lateral plate, and complained of continued pain over the lateral femoral condyle after the fracture fixation. The average age was 42.6 (ranges: 20~66) and initial fracture types included 16 cases of C1, 11 cases of C2, and 5 cases of C3 following AO/ASIF classification guidelines. Measured outcomes included: associated intra-articular pathologies, time needed to return to activities of daily living, patients' overall satisfaction, complications following the removal of hardware, and pain before and 6 months after the operation. Results: The distal-most end of the plate was placed in the knee joint in all cases and damage of the lateral articular capsule was found in 23 cases. Continuous wound discharge after surgery was found in one case who underwent arthroscopy-assisted plate removal, and it was treated by irrigation and re-suture. Average time needed to return to activities of daily living was 7 days in arthroscopy assisted group and 7.6 days in conventionally removed group. Fourteen patients (82.4%) who underwent arthroscopyassisted plate-removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 4.9 to 1.9, six months after the plate removal. Thirteen patients(86.7%) who underwent conventional plate removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 5.2 to 2.5, six months after the operation. Conclusion: Through minimally invasive arthroscopic-assisted plate removal, intrarticular pathology of the knee joint was able to be simultaneously identified and treated at the time of hardware removal. Damage of lateral capsule of the knee joint caused by the inserted plate for the treatment of type C distal femoral fracture was very frequently found and following the plate removal, patients experienced an improvement in pain score. We therefore recommend routine lateral distal femoral plate removal if the bony union is attained in such cases as type C distal femoral fractures whose distal most end of the plates are located in the joint.

  • PDF

Pseudoaneurysms of Peripheral Arteries - A Report of 6 Cases- (말초동맥에 발생한 가성동맥류의 외과적 치료 -치험 6례-)

  • 류완준;조창욱
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.927-930
    • /
    • 1996
  • We experienced six cases of pseudoaneurysm of the peripheral artery which occurred after stab wound or after diagnostic and operative procedures. Among 6 cases, 4 cases of pseudoaneurysm were developed in the femoral arteries, and others were the subclavian and the axillary artery. Two of 6 cases were combined with previous arterio enous fistula. Doppler imaging and angiogram were performed for the dignosis and an operation. Operative procedures were resection of the aneurysm, ligation of the involved arteries and reconstruction of the artery with the autogenous saphenous vein or the cephalic vein graft. Each operations were successfully performed without any disability.

  • PDF

Microsurgical Anatomy in Transoral Odontoidectomy (경구강 치상돌기제거술의 수술해부학)

  • Park, Kwan;Lee, Sang Koo;Cho, Tae Goo;Nam, Do-Hyun;Lee, Jung-Il;Kim, Jong-Soo;Hong, Seung-Chyul;Shin, Hyung-Jin;Eoh, Whan;Kim, Jong-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.3
    • /
    • pp.309-316
    • /
    • 2000
  • Objective :The transoral approach allows direct view of the ventral craniovertebral junction and provides useful management of the various lesions of this area. We present a step by step guide to the performance of the transoral excision of the odontoid process in the cadaveric model. Methods : Ten cadaver heads were used in fixed or unfixed state. We describe the relevant surgical anatomy in the cadaveric dissection and surgical technique of transoral transpharyngeal odontoidectomy. Results : The surgical procedure of transoral odontoidectomy was categorized by six steps;soft palate, posterior pharyngeal wall, muscular structures, osseous structures, odontoid process and ligaments, cruciate ligament and dura. Conclusion : With anatomical knowledge of these regions neurosurgeons can deal with wide variety of lesions in the ventral craniovertebral junction.

  • PDF

Arthroscopic Retrieval Analysis for Intra-articular Foreign Body of the Knee Joint (슬관절내 이물질에 대한 관절경적 제거술식의 분석)

  • Lee, Byung-Ill;Choi, Hyung-Suk;Jo, Joo-Hyoung;Kwon, Sai-Won
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.211-216
    • /
    • 2008
  • Purpose: The frequency of foreign body in the knee joint is not as high, but it sometimes required wide or multiple arthrotomy in order to remove, which can baffle the surgeon in some ways. Our study is to evaluate for effectiveness of arthroscopic retrieval for intra-articular foreign body in the knee joint. Materials and Methods: The 22 patients(16 males, 6 females) had received arthroscopic foreign body retrieval in the knee joint from March 1983 to September 2006. The causes of foreign bodies of the knee joint were 7 of trauma (31.9%) related cases, 13 of surgery related cases (59.0%), 2 found during follow up after operation (8.1%) in pathologies of foreign body. Results: There were 15 of metal showed the most percentage (68.1%), 7 of non-metal (31.9%) in types of foreign bodies, and others included bullet, suture material, pencil lead, broken wire etc. All cases were used by arthroscopic techniques. All foreign bodies were removed easily and were showed no complication such as postoperative joint stiffness. Conclusion: Arthroscopic foreign body retrieval in the knee joint is effective surgery in terms of easy access to foreign body and less postoperative complication.

  • PDF

Surgical Treatment of Varicose Vein - TIPP(Transilluminated Powered Phlebectomy) - (정맥류 환자의 수술적 치료 -광투시 전도형 정맥적출요법-)

  • 이교준;김해균;정은규;강두영
    • Journal of Chest Surgery
    • /
    • v.35 no.2
    • /
    • pp.144-148
    • /
    • 2002
  • The present study was done to determine the efficacy and safety of varicose vein removal using a minimally invasive, powered vein-extracting device with cutaneous transillumination and tumescent anesthesia techniques and then compared this to a retrospective group of conventional phlebectomy operations. There were 133 limbs in 104 patients(72 women, 32 men) treated with the use of the vein extractor aided by transcutaneous illumination. The hydrodissection was performed with Trivex™ Irrigated illuminator(Smith & Nephe $w^{ R}$) system using normal saline after the 2~3mm sized skin incision. Varicose clusters were extracted by the use of TriveTM esector(Smith & Nephe $w^{ R}$) system under transillumination. After the varisoce vein extraction, the operation area was compressed with surgical pad for bleeding control. The complication rate was 3.84% The mean number of incisions was 3.24 and mean operative time per limb was 65.9 minutes. The mean hospitalization was 1.86 days. The varicose vein extraction using transilluminated powered phlebectomy(TIPP) is a safe, efficacious and cosmetically satisfactory method. The procedure decreases the operating time and the number of incisions required to remove varicose clusters. Further evaluation and long term follow up will be necessary to determine the recurrence rate and long termcomplications.to determine the recurrence rate and long termcomplications.

Multimodal Treatment of Pleuropulmonary Blastoma -Two case report- (흉막폐아세포종(Pleuropulmonary Blastoma) -치험 2예 보고-)

  • 박준석;한정호;구홍회;김진국
    • Journal of Chest Surgery
    • /
    • v.36 no.8
    • /
    • pp.614-618
    • /
    • 2003
  • Pleuropulmonary blastoma (PPB) is a rare intrathoracic neoplasm, found solely in childhood. The usual symptoms are dyspnea, chest discomfort, recurrent respiratory infections, fever, dry cough, and chest pain. The progress of PPB is usually aggressive and its progress is generally poor. Lymphatic spread to the hilar and mediastinal nodes can occur Distant metastasis is found in brain, bones, and intra-abdominal organs. Surgical resection is the treatment of choice. When the disease Is too extensive for surgical resection, neoadjuvant chemotherapy can be used. We report 2 cases of pleuropulrnonary blastoma in children successfully treated with multimodal therapy.