Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy (전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가)

  • Choi, Woo Keun;Chun, Jun Chul;Ju, Sang Gyu;Min, Byung Jun;Park, Su Yeon;Nam, Hee Rim;Hong, Chae-Seon;Kim, MinKyu;Koo, Bum Yong;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.64-71
    • /
    • 2016
  • We develop a manufacture procedure for the production of a patient specific customized bolus (PSCB) using a 3D printer (3DP). The dosimetric accuracy of the 3D-PSCB is evaluated for electron beam therapy. In order to cover the required planning target volume (PTV), we select the proper electron beam energy and the field size through initial dose calculation using a treatment planning system. The PSCB is delineated based on the initial dose distribution. The dose calculation is repeated after applying the PSCB. We iteratively fine-tune the PSCB shape until the plan quality is sufficient to meet the required clinical criteria. Then the contour data of the PSCB is transferred to an in-house conversion software through the DICOMRT protocol. This contour data is converted into the 3DP data format, STereoLithography data format and then printed using a 3DP. Two virtual patients, having concave and convex shapes, were generated with a virtual PTV and an organ at risk (OAR). Then, two corresponding electron treatment plans with and without a PSCB were generated to evaluate the dosimetric effect of the PSCB. The dosimetric characteristics and dose volume histograms for the PTV and OAR are compared in both plans. Film dosimetry is performed to verify the dosimetric accuracy of the 3D-PSCB. The calculated planar dose distribution is compared to that measured using film dosimetry taken from the beam central axis. We compare the percent depth dose curve and gamma analysis (the dose difference is 3%, and the distance to agreement is 3 mm) results. No significant difference in the PTV dose is observed in the plan with the PSCB compared to that without the PSCB. The maximum, minimum, and mean doses of the OAR in the plan with the PSCB were significantly reduced by 9.7%, 36.6%, and 28.3%, respectively, compared to those in the plan without the PSCB. By applying the PSCB, the OAR volumes receiving 90% and 80% of the prescribed dose were reduced from $14.40cm^3$ to $0.1cm^3$ and from $42.6cm^3$ to $3.7cm^3$, respectively, in comparison to that without using the PSCB. The gamma pass rates of the concave and convex plans were 95% and 98%, respectively. A new procedure of the fabrication of a PSCB is developed using a 3DP. We confirm the usefulness and dosimetric accuracy of the 3D-PSCB for the clinical use. Thus, rapidly advancing 3DP technology is able to ease and expand clinical implementation of the PSCB.

Effect of the Angle of Ventricular Septal Wall on Left Anterior Oblique View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 심실중격 각도에 따른 좌전사위상 변화에 대한 연구)

  • You, Yeon Wook;Lee, Chung Wun;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae;Bang, Ji-In;Lee, Soo Jin;Kim, Tae-Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.13-19
    • /
    • 2016
  • Purpose In order to calculate the left ventricular ejection fraction (LVEF) accurately, it is important to acquire the best septal view of left ventricle in the multi-gated cardiac blood pool scan (GBP). This study aims to acquire the best septal view by measuring angle of ventricular septal wall (${\theta}$) using enhanced CT scan and compare with conventional method using left anterior oblique (LAO) 45 view. Materials and Methods From March to July in 2015, we analyzed the 253 patients who underwent both enhanced chest CT and GBP scan in the department of nuclear medicine at National Cancer Center. Angle (${\theta}$) between ventricular septum and imaginary midline was measured in transverse image of enhanced chest CT scan, and the patients whose difference between the angle of ${\theta}$ and 45 degree was more than 10 degrees were included. GBP scan was acquired using both LAO 45 and LAO ${\theta}$ views, and LVEFs measured by automated and manual region of interest (Auto-ROI and Manual-ROI) modes respectively were analyzed. Results $Mean{\pm}SD$ of ${\theta}$ on total 253 patients was $37.0{\pm}8.5^{\circ}$. Among them, the patients whose difference between 45 and ${\theta}$ degrees were more than ${\pm}10$ degrees were 88 patients ($29.3{\pm}6.1^{\circ}$). In Auto-ROI mode, there was statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=62.0{\pm}6.6%$ vs. LVEF ${\theta}=64.0{\pm}5.6%$; P = 0.001). In Manual-ROI mode, there was also statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=66.7{\pm}7.2%$ vs. LVEF ${\theta}=69.0{\pm}6.4%$; P < 0.001). Intraclass correlation coefficients of both methods were more than 95%. In case of comparison between Auto-ROI and Manual ROI of each LAO 45 and LAO ${\theta}$, there was no significant difference statistically. Conclusion We could measure the angle of ventricular septal wall accurately by using transverse image of enhanced chest CT and applied to LAO acquisition in the GBP scan. It might be the alternative method to acquire the best septal view of LAO effectively. We could notify significant difference between conventional LAO 45 and LAO ${\theta}$ view.

  • PDF

GET Imaging Evaluation of Patients with Esophageal Cancer (식도암 환자의 GET 영상 평가)

  • Moon, Jong Wun;Lee, Chung Wun;Seo, Young Deok;Yun, Sang Hyeok;Kim, Yong Keun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.31-36
    • /
    • 2013
  • Purpose: Measure gastric emptying time (GET: Gastric Emptying Time) is a non-invasive and quantitative evaluation methods, mainly by endoscopic or radiological examination confirmed no mechanical obstruction in patients with symptoms of congestion is checked. Such tests are not common gastric emptying time measured esophageal cancer patients (who underwent esophagectomy) patients after surgery for gastric emptying time was measured test. And the period of time for more than one year after the gastric emptying time measurement was performed. By comparing the two kinds of tests in the chest cavity after surgery as the evaluation of gastrointestinal function tests evaluate the usefulness of GET, and will evaluate the characteristics of the image. Materials and Methods: 93 patients who underwent esophagectomy with gastric emptying time measurement of subject tests immediately after surgery and after 1 year or longer were twice. Preparation of the patient before the test is more than 12 hours of overnight fasting is important, in addition to the medicine or to stop smoking, and diabetes insulin injections should be early in the morning is ideal to test. Generally labeled with $^{99m}Tc-DTPA$ resin which is used to make steamed egg, seaweed and fermented milk with a high viscosity after eating, three hours in the standing position was measured. Evaluation of gastric emptying curves on the way intragastric radioactivity level by 50% the time (half-time [T1/2]) was calculated, based on the half-life was divided into three steps: over 180 minutes was defined as delayed gastric emptying, within 180minutes was defined as intermediate gastric emptying and when all the radioisotopes were dumped into the jejunum as soon as swallowed, was defined as rapid gastric emptying. Results: Gastric emptying time of a typical images stomach of antrum and fundus additional images appear stronger over time move on to the small intestine. but esophageal cancer who underwent esophagectomy side of the thoracic cavity showed a strong image. Immediately after surgery, the half-time (T1/2) of rapid gastric emptying appeared to 12.9%, intermediate gastric emptying appeared to 52.7%, delay gastric emptying appeared to 34.4%. After more than a year the results of the half-life after surgery, 67% of rapid gastric emptying to intermediate gastric emptying was changed, 69% of delay gastric emptying to intermediate gastric emptying changed. Intermediate gastric emptying worse in patients rapid gastric emptying and the delay gastric emptying is 24% in the case. Conclusion: Esophagectomy for esophageal cancer who underwent half-time measurement test (T1/2) rapid gastric emptying and delay gastric emptying are the result of the comparison over time, changes were observed intermediate gastric emptying. Mainly seeing of gastric emptying time measurement in the esophagus instead of thoracic cavity to check the evaluation of gastrointestinal function can be useful even means. And segmentation criteria and narrow time interval of checking if more accurate information and analysis of the clinical diagnosis and evaluation seems to be done.

  • PDF

Clinical Presentation of the Patients with Non-traumatic Chest Pain in Emergency Department (응급의료센터에 내원한 비외상성 흉통환자의 임상 양상)

  • Chung, Jun-Young;Lee, Sam-Beom;Do, Byung-Soo;Park, Jong-Seon;Shin, Dong-Gu;Kim, Young-Jo
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.283-295
    • /
    • 1999
  • Background: Patients with acute non-traumatic chest pain are among the most challenging patients for care by emergency physicians, so the correct diagnosis and triage of patients with chest pain in the emergency department(ED) becomes important. To avoid discharging patients with acute myocardial infarction(AMI) without medical care, most emergency physicians attempt to admit almost all patients with acute chest pain and order many laboratory tests for the patients. But in practice, many patients with non-cardiac pain can be discharged with simple tests and treatment. These patients occupy expensive intensive care beds, substantially increasing financial cost and time of stay at ED for the diagnosis and treatment of myocardial ischemia and AMI. Despite vigorous efforts to identify patients with ischemic heart disease, approximately 2% to 5% of patients presented to the ED with AMI and chest pain are inadvertently discharged. If the cause for the chest pain is known, rapid and accurate diagnosis can be implemented, preventing wastes in time and money and inadvertent discharge. Methods and Results: The medical records of 488 patients from Jan. 1 to Dec. 31, 1997 were reviewed. There were 320(angina pectoris 140, AMI 128) cases of cardiac diseases, and 168(atypical chest pain 56, pneumothorax 47) cases of non-cardiac diseases. The number of associated symptoms were $1.1{\pm}0.9$ in non-cardiac diseases, $1.4{\pm}1.1$ in cardiac diseases and $1.7{\pm}1.1$ in AMI(p<0.05). In laboratory finding the sensitivity of electrocardiography(EKG) was 96.1%, while the sensitivity of myoglobin test ranked 45.1%. Admission rate was 71.6% in for cardiac diseases and 50.6% for non-cardiac diseases(p<0.01). Mortality rate was 8.8% in all cases, 13.8% in cardiac diseases, 0.6% in non-cardiac diseases, and 28.1% especially in AMI. Conclusion: In conclusion, all emergency physicians should have thorough knowledge of the clinical characteristics of the diseases which cause non-traumatic chest pain, because a patient with any of these life-threatening diseases would require immediate treatment. Detailed history on the patient should be taken and physical examination performed. Then, the most simple diagnostic approach should be used to make an early diagnosis and to provide treatment.

  • PDF

The Precision Test Based on States of Bone Mineral Density (골밀도 상태에 따른 검사자의 재현성 평가)

  • Yoo, Jae-Sook;Kim, Eun-Hye;Kim, Ho-Seong;Shin, Sang-Ki;Cho, Si-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.67-72
    • /
    • 2009
  • Purpose: ISCD (International Society for Clinical Densitometry) requests that users perform mandatory Precision test to raise their quality even though there is no recommendation about patient selection for the test. Thus, we investigated the effect on precision test by measuring reproducibility of 3 bone density groups (normal, osteopenia, osteoporosis). Materials and Methods: 4 users performed precision test with 420 patients (age: $57.8{\pm}9.02$) for BMD in Asan Medical Center (JAN-2008 ~ JUN-2008). In first group (A), 4 users selected 30 patient respectively regardless of bone density condition and measured 2 part (L-spine, femur) in twice. In second group (B), 4 users measured bone density of 10 patients respectively in the same manner of first group (A) users but dividing patient into 3 stages (normal, osteopenia, osteoporosis). In third group (C), 2 users measured 30 patients respectively in the same manner of first group (A) users considering bone density condition. We used GE Lunar Prodigy Advance (Encore. V11.4) and analyzed the result by comparing %CV to LSC using precision tool from ISCD. Check back was done using SPSS. Results: In group A, the %CV calculated by 4 users (a, b, c, d) were 1.16, 1.01, 1.19, 0.65 g/$cm^2$ in L-spine and 0.69, 0.58, 0.97, 0.47 g/$cm^2$ in femur. In group B, the %CV calculated by 4 users (a, b, c, d) were 1.01, 1.19, 0.83, 1.37 g/$cm^2$ in L-spine and 1.03, 0.54, 0.69, 0.58 g/$cm^2$ in femur. When comparing results (group A, B), we found no considerable differences. In group C, the user_1's %CV of normal, osteopenia and osteoporosis were 1.26, 0.94, 0.94 g/$cm^2$ in L-spine and 0.94, 0.79, 1.01 g/$cm^2$ in femur. And the user_2's %CV were 0.97, 0.83, 0.72 g/$cm^2$ L-spine and 0.65, 0.65, 1.05 g/$cm^2$ in femur. When analyzing the result, we figured out that the difference of reproducibility was almost not found but the differences of two users' several result values have effect on total reproducibility. Conclusions: Precision test is a important factor of bone density follow up. When Machine and user's reproducibility is getting better, it’s useful in clinics because of low range of deviation. Users have to check machine's reproducibility before the test and keep the same mind doing BMD test for patient. In precision test, the difference of measured value is usually found for ROI change caused by patient position. In case of osteoporosis patient, there is difficult to make initial ROI accurately more than normal and osteopenia patient due to lack of bone recognition even though ROI is made automatically by computer software. However, initial ROI is very important and users have to make coherent ROI because we use ROI Copy function in a follow up. In this study, we performed precision test considering bone density condition and found LSC value was stayed within 3%. There was no considerable difference. Thus, patient selection could be done regardless of bone density condition.

  • PDF

The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media (PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향)

  • Ahn, Sha-Ron;Park, Hoon-Hee;Park, Min-Soo;Lee, Seung-Jae;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. $^{18}F$- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients' weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.

  • PDF

The Evaluation of Predose Counts in the GFR Test Using $^{99m}Tc$-DTPA ($^{99m}Tc$-DTPA를 이용한 사구체 여과율 측정에서 주사 전선량계수치의 평가)

  • Yeon, Joon-Ho;Lee, Hyuk;Chi, Yong-Ki;Kim, Soo-Yung;Lee, Kyoo-Bok;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.94-100
    • /
    • 2010
  • Purpose: We can evaluate function of kidney by Glomerular Filtration Rate (GFR) test using $^{99m}Tc$-DTPA which is simple. This test is influenced by several parameter such as net syringe count, kidney depth, corrected kidney count, acquisition time and characters of gamma camera. In this study, we evaluated predose count according to matrix size in the GFR test using $^{99m}Tc$-DTPA. Materials and Methods: Gamma camera of Infinia in GE was used, and LEGP collimator, three types of matrix size ($64{\times}64$, $128{\times}128$, $256{\times}256$) and 1.0 of zoom factor were applied. We increased radioactivity concentration from 222 (6), 296 (8), 370 (10), 444 (12) up to 518 MBq (14 mCi) respectively and acquired images according to matrix size at 30 cm distance from detector. Lastly, we evaluated these values and then substituted them for GFR formula. Results: In $64{\times}64$, $128{\times}128$ and $256{\times}256$ of matrix size, counts per second was 26.8, 34.5, 41.5, 49.1 and 55.3 kcps, 25.3, 33.4, 41.0, 48.4 and 54.3 kcps and 25.5, 33.7, 40.8, 48.1 and 54.7 kcps respectively. Total counts for 5 second were 134, 172, 208, 245 and 276 kcounts from $64{\times}64$, 127, 172, 205, 242, 271 kcounts from $128{\times}128$, and 137, 168, 204, 240 and 273 kcounts from $256{\times}256$, and total counts for 60 seconds were 1,503, 1,866, 2,093, 2,280, 2,321 kcounts, 1,511, 1,994, 2,453, 2,890 and 3,244 kcounts, and 1,524, 2,011, 2,439, 2,869 and 3,268 kcounts respectively. It is different from 0 to 30.02 % of percentage difference in $64{\times}64$ of matrix size. But in $128{\times}128$ and $256{\times}256$, it is showed 0.60 and 0.69 % of maximum value each. GFR of percentage difference in $64{\times}64$ represented 6.77% of 222 MBq (6 mCi), 42.89 % of 518 MBq (14 mCi) at 60 seconds respectively. However it is represented 0.60 and 0.63 % each in $128{\times}128$ and $256{\times}256$. Conclusion: There was no big difference in total counts of percentage difference and GFR values acquiring from $128{\times}128$ and $256{\times}256$ of matrix size. But in $64{\times}64$ of matrix size when the total count exceeded 1,500 kcounts, the overflow phenomenon was appeared differently according to predose radioactivity of concentration and acquisition time. Therefore, we must optimize matrix size and net syringe count considering the total count of predose to get accurate GFR results.

  • PDF

Immunostimulntory Effects of Immu-Forte at 3 Months Post-Treatment in Mice (면역기능증강성 동암 바이오스 신물질에 대한 3개월간의 마우스 투여후의 면역학적 및 혈액학적 변화)

  • Jung Ji-Youn;Ahn Nam-Shik;Park Joon-Suk;Jo Eun-Hye;Hwang Jae-Woong;Lee Seoung-Hun;Park Jung-Ran;Kim Sun-Jung;Lee Yong-Geon;Jeong Yun-Hyeok;Chung Ji-Hye;Lee Soo-Jin;Lee Sang-Bum
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.2
    • /
    • pp.118-122
    • /
    • 2005
  • Immu-Forte (Dong-Ahm Bio's. Corp., Korea) was evaluated fir its effectiveness as a nonspecific immunostimulator in mice. The effects of Immu-Forte were determined by analysis of cytokines using ELISh and phenotype of leukocyte subpopulations using monoclonal antibodies specific to mouse leukocyte differentiation antigens and flow cytometry. CD4 T cells, CD8 T cells, macrophages, IL-12 and IFN-r in Immu-Forte EX-treated middle dose group increased in 3 months posttreatment and were significantly higher (p<0.05) than that of control at 3 months posttreatment. All T cells, all B cells, macrophages, IL-2, IL-4 and IL-12 in Immu-Forte EX-treated low dose uoup increased in 3 months posttreatment and were significantly higher (p<0.05) than that of control at 3 months posttreatment. In the Immu-Forte soy-treated group, CD4 T cells, IL-2, IL-4 and IL-12 were significantly higher in high dose-treated group, and CD 4 T cell, macrophages, IL-2, IL-4 and IL-12 were significantly higher in middle dose-treated group, and all T cell, IL-2, IL-4 and IL-12 were significantly higher in low dose-treated group. In the Itnmu-Forte A-treated group, macrophages, m cells and IL-12 in high dose-treated group and all T cells, macrophages, NK cells, IL-2, IL-4 and IL-12 in middle dose-treated group and NK cells in low dose-treated group were significantly higher (p<0.05) than that of control at 3 months posttreatment. In the Immu-Forte F-treated Group, all B cells, IL-4 and IL-12 in high dose-treated group and all T cells, aBl B cells, CD 4 T cells, CD8 T cells, macrophage, IL-2, IL-4, IL-12 and IFN-r in middle dose-treated group and NK cells and IL-12 in low dose-treated group were significantly higher (p<0.05) than that of control at 3 months posttreatment. In conclusion, the study has demonstrated that Immu-Forte had an immunostimulatory effect on mice through proliferation and activation of mouse immune cells.

The Content of Minerals and Vitamins in Commercial Beverages and Liquid Teas (유통음료 및 액상차 중의 비타민과 미네랄 함량)

  • Shin, Young;Kim, Sung-Dan;Kim, Bog-Soon;Yun, Eun-Sun;Chang, Min-Su;Jung, Sun-Ok;Lee, Yong-Cheol;Kim, Jung-Hun;Chae, Young-Zoo
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.4
    • /
    • pp.322-329
    • /
    • 2011
  • This study was done to analyze the contents of minerals and vitamins to compare the measured values of minerals, vitamins with labeled values of them in food labeling and to investigate the ratio of measured values to labeled values in 437 specimen with minerals and vitamins - fortified commercial beverages and liquid teas. Content of calcium and sodium in samples after microwave digestion was analyzed with an ICP-OES (Inductively Coupled Plasma Optical Emission Spectrometer) and vitamins were determined using by HPLC (High Performance Liquid Chromatography). The measured values of calcium were ranged 80.3~142.6% of the labeled values in 21 samples composed calcium - fortified commercial beverages and liquid teas. In case of sodium, measured values were investigated 33.9~48.5% of the labeled values in 21 sports beverages. The measured values of vitamin C, vitamin $B_2$ and niacin were ranged 99.7~2003.6, 81.1~336.7, 90.7~393.2% of the labeled values in vitamins - fortified commercial beverages and liquid teas, 57, 12, 11 samples. To support achievement of the accurate nutrition label, there must be program and initiatives for better understanding and guidances on food labelling and nutrition for food manufacture.

Peak Expiratory Flow in Normal Healthy Korean Subjects Measured by Mini-Wright Peak Flow Meter (Mini-Wright Peak Flow Meter로 측정한 한국 성인의 최고호기유량의 정상치)

  • Kim, Young-Sam;Ahn, Ae-Ran;Kim, Se-Kyu;Chang, Joon;Ahn, Chul-Min;Oh, Jai-Joon;Kim, Sung-Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.3
    • /
    • pp.320-333
    • /
    • 2001
  • Background : Peak expiratory flow (PEF) provides a simple, quantitative, and reproducible measure of the existence and severity of airflow obstructions. Peak flow meters are designed to monitor the condition asthma patients. There are many reports showing the normal predicted value of PEF in other countries. Studies on healthy Korean adults have been performed in a relatively small sample number and a lower limit for the normal value was not reported. Therefore, an attempt to provide normal predictive PEF value with a lower limit was made. Method : The PEF(Mini-Wright Peak Flow Meter) measurements and spirometry were done in 233 men and 631 women without history of respiratory disease. All subjects were non-smokers with no respiratory symptoms. The normal predictive value and its lower limit were developed by multiple regression analysis. The result was compared with regression equations in other reports. Results : The regression equation for the normal PEF predictive value(L/min) is $25.117+4.587{\times}$Age(year)-$0.064{\times}Age^2+2.931{\times}$Height(cm) in men($R^2=025$), and 146.942-$0.011{\times}Age^2+1.795{\times}$Height(cm)+$0.836{\times}$Weight(kg) in women($R^2=0.21$). The regression equation for the lower limit of this value (L/min) is $25.117+4.587{\times}$Age(year)-$0.064{\times}Age^2+1.936{\times}$Height(cm) in men, and $146.942-0.011{\times}Age^2+1.232{\times}$Height(cm)+$0.481{\times}$Weight(kg) in women. The residuals were normally distributed. The PEF in Korean males was sililar to those reported in British and Japanese subjects. The PEF in Korean females was similar to that in British subjects, but higher than the PEF in Japanese subjects. The lower limit of normal value was 71% of normal predictive PEF value in men and 76% in women. Conclusion : The normal predictive PEF value and its lower limit was measured from 233 male and 631 female asymptomatic, lifelong non-smoking participants. The normal predictive value was different from those of other studies on Korean subjects. Therefore, further studies are required.

  • PDF